1.
J Imaging ; 9(6)2023 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-37367460

RESUMO

This work reports on a terahertz tomography technique using constant velocity flying spot scanning as illumination. This technique is essentially based on the combination of a hyperspectral thermoconverter and an infrared camera used as a sensor, a source of terahertz radiation held on a translation scanner, and a vial of hydroalcoholic gel used as a sample and mounted on a rotating stage for the measurement of its absorbance at several angular positions. From the projections made in 2.5 h and expressed in terms of sinograms, the 3D volume of the absorption coefficient of the vial is reconstructed by a back-projection method based on the inverse Radon transform. This result confirms that this technique is usable on samples of complex and nonaxisymmetric shapes; moreover, it allows 3D qualitative chemical information with a possible phase separation in the terahertz spectral range to be obtained in heterogeneous and complex semitransparent media.

2.
Sci Rep ; 12(1): 7814, 2022 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-35551475

RESUMO

Knowledge of material emissivity maps and their true temperatures is of great interest for contactless process monitoring and control with infrared cameras when strong heat transfer and temperature change are involved. This approach is always followed by emissivity or reflections issues. In this work, we describe the development of a contactless infrared imaging technique based on the pyro-reflectometry approach and a specular model of the material reflection in order to overcome emissivities and reflections problems. This approach enables in situ and real-time identification of emissivity fields and autocalibration of the radiative intensity leaving the sample by using a black body equivalent ratio. This is done to obtain the absolute temperature field of any specular material using the infrared wavelength. The presented set up works for both camera and pyrometer regardless of the spectral range. The proposed method is evaluated at room temperature with several heterogeneous samples covering a large range of emissivity values. From these emissivity fields, raw and heterogeneous measured radiative fluxes are transformed into complete absolute temperature fields.

3.
Appl Spectrosc ; 75(4): 462-474, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33119454

RESUMO

In this technical note, we present an advanced thermospectroscopic imager based on a Fourier transform infrared (FT-IR) spectrometer and a thermal camera. This new instrument can image both thermal emission and multispectral absorbance fields in a few seconds at a resolution of 4 cm-1 or less. The setup is made of a commercial FT-IR spectrometer (ThermoFisher Nicolet iS50R) synchronized to an IR camera (indium antimonide and strained layer superlattice) as a detector to record the interferograms in each pixel of the images. A fast Fourier transform algorithm with apodization and Mertz phase correction is applied to the images, and the background is rationed to process the interferograms into the absorbance spectra in each pixel. The setup and image processing are validated using thin polystyrene films; during this processing, more than 1750 spectra per second are recorded. A spectral resolution equivalent to that of commercial FT-IR spectrometers is obtained for absorbance peaks valued less than two. The transient capability of the FT-IR thermospectroscopic imager is illustrated by measuring the heterogeneous thermal and absorbance fields during the phase change of paraffin over a few minutes. The complete mechanism of the thermochemical processes during a polymer solidification is revealed through the thermospectroscopic images, demonstrating the usefulness of such an instrument in studying fast transient thermal and chemical phenomena with an improved spectral resolution.

4.
Appl Spectrosc ; 72(2): 177-187, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28933199

RESUMO

The purpose of this article is to present a new calibration procedure for spectroscopic measurements using an infrared focal plane array (IRFPA) spectrometer on highly opaque middle-wave infrared (MWIR) media. The procedure is based on the properties of the IRFPA camera and especially the integration time (IT), which is the main parameter that can be adjusted to control the sensitivity of the measurements. The goal of the paper is to experimentally validate this dependence with the direct reference intensity light coming out of the IR monochromator in order to predict the spectrum shape and intensity level in a range out of the camera saturation. This method allows determining spectrum used as background for transmittance calculation. It has been applied in the case of measurement of water transmittance, which is a highly opaque medium and whose measurement requires high ITs. The main result is the ability to take an IR spectroscopic imaging measurement through 300 µm of water and the determination of its transmittance with sufficient sensitivity due to the proposed calibration procedure. This procedure allows the possibility of transitory studies in heterogeneous aqueous media.

5.
Appl Opt ; 52(11): 2320-4, 2013 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-23670761

RESUMO

Coupling optical and thermal properties of a terahertz (THz) thermal converter based on the Seebeck effect provides an unsupplied room-temperature measuring device dedicated to THz power metrology. Performance characteristics such as broadband response (0-30 THz), high sensitivity (<25 µW·Hz(-0.5)), and the possibility to develop an internal absolute self-calibration estimated at 9.93 W·V(-1) are reported. Advantages and drawbacks of this THz powermeter are discussed.


Assuntos
Transferência de Energia , Radiometria/instrumentação , Radiometria/normas , Radiação Terahertz , Termografia/instrumentação , Termografia/normas , Calibragem , Desenho de Equipamento , Análise de Falha de Equipamento , Internacionalidade , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Temperatura
6.
Appl Opt ; 51(28): 6738-44, 2012 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-23033089

RESUMO

Three-dimensional terahertz computed tomography has been used to investigate dried human bones such as a lumbar vertebra, a coxal bone, and a skull, with a direct comparison with standard radiography. In spite of lower spatial resolution compared with x-ray, terahertz imaging clearly discerns a compact bone from a spongy one, with strong terahertz absorption as shown by additional terahertz time-domain transmission spectroscopy.


Assuntos
Osso e Ossos/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imagem Terahertz/métodos , Osso e Ossos/anatomia & histologia , Humanos , Vértebras Lombares/anatomia & histologia , Vértebras Lombares/diagnóstico por imagem , Ossos Pélvicos/anatomia & histologia , Ossos Pélvicos/diagnóstico por imagem , Crânio/anatomia & histologia , Crânio/diagnóstico por imagem , Radiação Terahertz , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA