Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
J Card Fail ; 30(10): 1302-1318, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39389742

RESUMO

Secondary mitral regurgitation (SMR) is associated with increased mortality and heart failure hospitalizations. The management of heart failure patients with SMR is complex and requires a multidisciplinary Heart Team approach. Guideline-directed medical therapies remain fundamental, yet in a proportion of patients SMR persists. In the past decade, transcatheter edge-to-edge repair (TEER) has been shown to improve survival in patients with SMR who remain symptomatic despite medical therapy. Technical advancements across newer generations of devices, improved imaging, and greater operator expertise have collectively contributed to the increased safety and efficacy of this procedure over time. Various emerging transcatheter mitral valve repair and replacement devices are currently under investigation and may offer superior, complementary or synergistic treatment options in patients ineligible for TEER. This review provides a state-of-the-art overview regarding the diagnosis of SMR, and currently available transcatheter mitral valve interventions and describes a contemporary approach to the management of SMR.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/terapia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Gerenciamento Clínico
3.
Am J Cardiol ; 225: 125-133, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38925261

RESUMO

Low-flow (LF) aortic stenosis (AS) is common among older adults and associated with worse outcomes than AS with normal stroke volume. It is unknown whether left ventricular (LV) remodeling identifies patients with LF AS at higher risk of complications. LV remodeling was evaluated in 463 patients with severe LF AS referred for transcatheter aortic valve replacement (TAVR) and classified as adaptive (normal geometry and concentric remodeling) or maladaptive (concentric and eccentric hypertrophy) using the American Society of Echocardiography gender-specific criteria. Of these, the 390 patients who underwent TAVR were followed for the end points of heart failure (HF) hospitalization and all-cause mortality. The mean patient age was 79 (74.5 to 84) years. LV remodeling was adaptive in 57.4% (62 normal geometry, 162 concentric remodeling) and maladaptive in 42.6% (127 concentric hypertrophy, 39 eccentric hypertrophy). During a median follow-up of 3 years, 45 patients (11.5%) were hospitalized for HF and 73 (18.7%) died. After adjustment for widely used echocardiographic parameters, maladaptive remodeling was independently associated with HF hospitalization and death (adjusted hazard ratio 1.75, confidence interval 1.03 to 3.00). There was no significant difference between men and women in the association of maladaptive LV remodeling with the composite outcome (p = 0.40 for men and p = 0.06 for women). In conclusion, in patients with LF AS, maladaptive LV remodeling before TAVR is independently associated with higher incidences of postprocedural HF rehospitalization and death in both men and women. Assessment of LV remodeling has prognostic value over and above LV ejection fraction and may improve risk stratification for patients with LF AS.


Assuntos
Estenose da Valva Aórtica , Ecocardiografia , Substituição da Valva Aórtica Transcateter , Remodelação Ventricular , Humanos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/complicações , Masculino , Feminino , Remodelação Ventricular/fisiologia , Idoso , Idoso de 80 Anos ou mais , Volume Sistólico/fisiologia , Insuficiência Cardíaca/fisiopatologia , Estudos Retrospectivos , Seguimentos , Hospitalização/estatística & dados numéricos
4.
J Invasive Cardiol ; 36(9)2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38787923
6.
Artigo em Inglês | MEDLINE | ID: mdl-38749898

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has undergone significant advances in recent years, with the development of improved pre-planning tools and devices. These advances have led to a reduction in the rate of paravalvular leak (PVL), a complication that is associated with poor outcomes even when mild. As some centers around the world are moving to solely fluoroscopy-focused implantation, we aimed to describe the clinical impact of intra-procedural transthoracic echocardiography (TTE) during TAVI in a high volume hospital. METHODS: Observational study during a 3-month period. A limited TTE examination was performed immediately after deployment to assess the existence of PVL and grade its severity. Complete TTE was performed a day after the procedure. In case of ≥mild PVL after valve deployment, a decision was made according to the severity of the PVL, patient anatomy and extent of annular calcification to preform balloon post-dilation. If done, an additional limited TTE was performed to assess possible complication and the degree of PVL post dilatation. RESULTS: 115 patient were included in the study. Intra-procedural TTE identified 16 patients (14 %) with at least mild PVL, three of them with moderate (3 %). Post balloon dilatation was performed in 10 patients (9 % of the cohort) with significant improvement in the degree of PVL. CONCLUSION: Intra-procedural TTE immediately after TAVI deployment can accurately identify PVL, allowing operators to perform post balloon dilatation with improvement in early echocardiographic results. Our findings support the routine use of TTE during procedures, without relying solely on fluoroscopy.

8.
Am J Cardiol ; 221: 84-93, 2024 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-38649128

RESUMO

A substantial number of patients may experience systemic inflammatory response syndrome (SIRS) and related adverse events after transcatheter aortic valve implantation and endovascular aortic aneurysm repair. Although a clear etiology has not been established, endothelial disruption and tissue-ischemic response secondary to the foreign material may represent the trigger events. A latency period (0 to 48 hours) may occur between the initial injury and onset of symptoms mirroring an initial local response followed by a systemic response. Clinical presentation can be mild or severe depending on external triggers and characteristics of the patient. Diagnosis is challenging because it simulates an infection, but lack of response to antibiotics, negative cultures are supportive of SIRS. Increased in-hospital stay, readmissions, major cardiovascular events, and reduced durability of the device used are the main complications. Treatment includes non-steroidal anti-inflammatory drugs or corticosteroids. In conclusion, further studies are warranted to fully explore pathophysiologic mechanisms underpinning SIRS and the possibility of enhancing device material immune compatibility to reduce the inflammatory reaction of the host tissue.


Assuntos
Complicações Pós-Operatórias , Síndrome de Resposta Inflamatória Sistêmica , Humanos , Síndrome de Resposta Inflamatória Sistêmica/diagnóstico , Síndrome de Resposta Inflamatória Sistêmica/terapia , Prognóstico , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/terapia , Procedimentos Endovasculares , Substituição da Valva Aórtica Transcateter/efeitos adversos , Anti-Inflamatórios não Esteroides/uso terapêutico
10.
Eur Heart J Cardiovasc Imaging ; 25(2): 267-277, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-37774491

RESUMO

AIMS: In patients with severe aortic stenosis (AS), low-flow low-gradient (LG) is a known predictor of worse outcomes. However, very LG may represent a distinct population with further cardiac dysfunction. It is unknown whether this population benefits from transcatheter aortic valve replacement (TAVR). We aimed to describe the patient characteristics and clinical outcomes of low-flow very LG severe AS. METHODS AND RESULTS: This single-centre study included all patients with low-flow severe AS between 2019 and 2021. Patients were divided into groups with very LG [mean pressure gradient (MPG) ≤ 20 mmHg], LG (20 < MPG < 40 mmHg), and high-gradient (HG) (MPG ≥ 40 mmHg). Composite endpoint of all-cause mortality and heart failure rehospitalization was compared. A total of 662 patients [very LG 130 (20%); LG 339 (51%); HG 193 (29%)] were included. Median follow-up was 12 months. Very LG cohort had a higher prevalence of comorbid conditions with lower left ventricular ejection fraction (45% vs. 57% vs. 60%; P < 0.001). There was a graded increase in the risk of composite endpoint in the lower MPG strata (P < 0.001). Among those who underwent TAVR, very LG was an independent predictor of the composite endpoint (adjusted HR 2.42 [1.29-4.55]). While LG and HG cohorts had decreased risk of composite endpoint after TAVR compared with conservative management, very LG was not associated with risk reduction (adjusted HR 0.69 [0.35-1.34]). CONCLUSION: Low-flow very LG severe AS represents a distinct population with significant comorbidities and worse outcomes. Further studies are needed to evaluate the short- and long-term benefits of TAVR in this population.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Estudos Retrospectivos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Índice de Gravidade de Doença
11.
Int J Cardiovasc Imaging ; 40(1): 81-82, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37983001

RESUMO

Leaflet thrombosis is usually an incidental finding and Cardiac CT is the gold standard for its diagnosis, but the classic features of hypoattenuation leaflet thickening (HALT) and hypoattenuation affecting motion (HAM) can also be seen on echocardiography and more specifically on trans-esophageal echocardiography. We describe a case of transcatheter aortic valve thrombosis where both the diagnosis and treatment were based exclusively on the echocardiographic evaluation, without the need of cardiac CT, with good outcome for the patient.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Valor Preditivo dos Testes , Valva Aórtica/cirurgia , Tomografia Computadorizada por Raios X , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
12.
Biomolecules ; 13(12)2023 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-38136567

RESUMO

Atherosclerosis is a chronic inflammatory disease characterized by lipid and inflammatory cell deposits in the inner layer of large- and medium-sized elastic and muscular arteries. Diabetes mellitus (DM) significantly increases the risk of cardiovascular diseases and the overall and cardiovascular mortality, and it is a pro-atherogenic factor that induces atherosclerosis development and/or accelerates its progression through a multifactorial process. Glucagon-like peptide-1 receptor agonists (GLP-1RAs) are a new class of drugs, belonging to the armamentarium to fight type 2 DM, that have shown robust reductions in atherosclerotic events and all-cause mortality in all studies. Preclinical studies have shown that GLP-1RAs play a role in the immunomodulation of atherosclerosis, affecting multiple pathways involved in plaque development and progression. In this review, we wanted to explore the translational power of such preclinical studies by analyzing the most recent clinical trials investigating the atheroprotective effect of GLP-1RAs.


Assuntos
Aterosclerose , Doenças Cardiovasculares , Diabetes Mellitus Tipo 2 , Inibidores de Hidroximetilglutaril-CoA Redutases , Humanos , Hipoglicemiantes/uso terapêutico , Agonistas do Receptor do Peptídeo 1 Semelhante ao Glucagon , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/metabolismo , Doenças Cardiovasculares/tratamento farmacológico , Aterosclerose/tratamento farmacológico , Receptor do Peptídeo Semelhante ao Glucagon 1/metabolismo
13.
Am J Cardiol ; 208: 6-12, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37806187

RESUMO

Prognostic implications of pulmonary hypertension (PH) in low-flow low-gradient (LG) aortic stenosis (AS) after transcatheter aortic valve replacement (TAVR) remains unexplored. We aimed to investigate the impact of baseline and changes in PH after TAVR. In this single-center retrospective study, we included patients who underwent TAVR for low-flow LG AS. Patients were categorized into 2 groups: baseline pulmonary artery systolic pressure (PASP) <46 mm Hg (no-to-mild PH) and PASP ≥46 mm Hg (moderate-to-severe PH). On the basis of changes in PASP after TAVR, patients were stratified into increased (ΔPASP ≥ + 5 mm Hg), no change (-4 to +4 mm Hg), and decreased (≤ -5 mm Hg) groups. Primary end point was a composite of all-cause mortality and heart failure rehospitalization. In total, 210 patients were included, 148 in the no-to-mild PH group and 62 in the moderate-to-severe PH group. Median follow-up was 13.2 months. The moderate-to-severe PH group was at an increased risk of composite end point (adjusted hazard ratio [HR] 3.5, 95% confidence interval [CI] 1.8 to 6.9), all-cause mortality (HR 2.4, 95% CI 1.1 to 5.6), and heart failure rehospitalization (HR 8.3, 95% CI 2.9 to 23.7). There were no differences in clinical outcomes among those with increased (32%), no change (28%), and decreased (39%) PASP after TAVR. In conclusion, moderate-to-severe PH at baseline is an independent predictor of worse clinical outcomes in patients with low-flow LG AS who undergo TAVR, and this cohort of patients do not seem to derive the benefits of postoperative reduction of PASP.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Hipertensão Pulmonar , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Hipertensão Pulmonar/epidemiologia , Hipertensão Pulmonar/etiologia , Prognóstico , Estudos Retrospectivos , Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Índice de Gravidade de Doença
15.
Int J Mol Sci ; 24(15)2023 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-37569352

RESUMO

A great deal of evidence has revealed an important link between gut microbiota and the heart. In particular, the gut microbiota plays a key role in the onset of cardiovascular (CV) disease, including heart failure (HF). In HF, splanchnic hypoperfusion causes intestinal ischemia resulting in the translocation of bacteria and their metabolites into the blood circulation. Among these metabolites, the most important is Trimethylamine N-Oxide (TMAO), which is responsible, through various mechanisms, for pathological processes in different organs and tissues. In this review, we summarise the complex interaction between gut microbiota and CV disease, particularly with respect to HF, and the possible strategies for influencing its composition and function. Finally, we highlight the potential role of TMAO as a novel prognostic marker and a new therapeutic target for HF.


Assuntos
Doenças Cardiovasculares , Microbioma Gastrointestinal , Insuficiência Cardíaca , Humanos , Metilaminas/metabolismo , Insuficiência Cardíaca/metabolismo
16.
J Cardiovasc Med (Hagerstown) ; 24(9): 676-679, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37409662

RESUMO

AIMS: Conduction abnormalities, requiring a permanent pacemaker (PPM), are the most common electrical complications after transcatheter aortic valve implantation (TAVI). The exact mechanism for conduction system defects is not yet clear. The local inflammatory process and edema are thought to play a role in the development of electrical disorders. Corticosteroids are effective anti-inflammatory and antiedematous agents. We aim to investigate the potential protective effect of corticosteroids on conduction defects after TAVI. METHODS: This is a retrospective study of a single center. We analyzed 96 patients treated with TAVI. Thirty-two patients received oral prednisone 50 mg for 5 days after the procedure. This population was compared with the control group. All patients were followed up after 2 years. RESULTS: Of the 96 patients included, 32 (34%) were exposed to glucocorticoids after TAVI. No differences in age, preexisting right bundle branch block or left bundle branch block, or valve type were seen among patients exposed to glucocorticoids versus those who were unexposed. We observed no significant differences between the two groups in the overall frequency of new PPM implantations during hospitalization (12% vs. 17%, P  = 0.76). The incidence of atrioventricular block (AVB) (STx 9% vs. non-STx 9%, P  = 0.89), right bundle branch block (STx 6% vs. non-STx 11%, P  = 0.71), and left bundle branch block (STx 34% vs. non-STx 31%, P  = 0.9) was not significantly different between the STx and non-STx groups. At 2 years after TAVI, none of the patients had implanted PPM or had severe arrhythmias documented by 24-h Holter ECG or cardiac examination. CONCLUSION: Oral prednisone treatment does not appear to significantly reduce the incidence of AVB requiring acute PPM implantation after TAVI.


Assuntos
Estenose da Valva Aórtica , Bloqueio Atrioventricular , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Bloqueio de Ramo/diagnóstico , Estudos Retrospectivos , Prednisona/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Doença do Sistema de Condução Cardíaco/diagnóstico , Doença do Sistema de Condução Cardíaco/complicações , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/prevenção & controle , Bloqueio Atrioventricular/terapia , Marca-Passo Artificial/efeitos adversos , Corticosteroides , Valva Aórtica/cirurgia , Resultado do Tratamento
17.
J Cardiovasc Dev Dis ; 10(5)2023 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-37233154

RESUMO

Valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) is emerging as an effective treatment for patients with symptomatically failing bioprosthetic valves and a high prohibitive surgical risk; a longer life expectancy has led to a higher demand for these valve reinterventions due to the increased possibilities of outliving the bioprosthetic valve's durability. Coronary obstruction is the most feared complication of valve-in-valve (ViV) TAVR; it is a rare but life-threatening complication and occurs most frequently at the left coronary artery ostium. Accurate pre-procedural planning, mainly based on cardiac computed tomography, is crucial to determining the feasibility of a ViV TAVR and to assessing the anticipated risk of a coronary obstruction and the eventual need for coronary protection measures. Intraprocedurally, the aortic root and a selective coronary angiography are useful for evaluating the anatomic relationship between the aortic valve and coronary ostia; transesophageal echocardiographic real-time monitoring of the coronary flow with a color Doppler and pulsed-wave Doppler is a valuable tool that allows for a determination of real-time coronary patency and the detection of asymptomatic coronary obstructions. Because of the risk of developing a delayed coronary obstruction, the close postprocedural monitoring of patients at a high risk of developing coronary obstructions is advisable. CT simulations of ViV TAVR, 3D printing models, and fusion imaging represent the future directions that may help provide a personalized lifetime strategy and tailored approach for each patient, potentially minimizing complications and improving outcomes.

18.
J Clin Med ; 12(10)2023 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-37240489

RESUMO

Severe tricuspid valve (TV) regurgitation (TR) has been associated with adverse long-term outcomes in several natural history studies, but isolated TV surgery presents high mortality and morbidity rates. Transcatheter tricuspid valve interventions (TTVI) therefore represent a promising field and may currently be considered in patients with severe secondary TR that have a prohibitive surgical risk. Tricuspid transcatheter edge-to-edge repair (T-TEER) represents one of the most frequently used TTVI options. Accurate imaging of the tricuspid valve (TV) apparatus is crucial for T-TEER preprocedural planning, in order to select the right candidates, and is also fundamental for intraprocedural guidance and post-procedural follow-up. Although transesophageal echocardiography represents the main imaging modality, we describe the utility and additional value of other imaging modalities such as cardiac CT and MRI, intracardiac echocardiography, fluoroscopy, and fusion imaging to assist T-TEER. Developments in the field of 3D printing, computational models, and artificial intelligence hold great promise in improving the assessment and management of patients with valvular heart disease.

19.
J Clin Med ; 12(4)2023 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-36836005

RESUMO

Mitral annular calcification (MAC) is a common chronic degenerative process of the mitral valve fibrous support ring. MAC increases the risk of mitral valve dysfunction, all-cause and cardiovascular mortality, and worse outcomes in cardiac interventions. Echocardiography represents the first imaging modality for MAC assessment, but it has low specificity compared to cardiac CT in terms of distinguishing between calcium and dense collagen. Novel three-dimensional transesophageal maximal intensity projection (MIP) mapping allows for the real-time MAC distribution and depth visualization of the cardiac anatomy and represents a useful and promising tool for pre-procedural assessment and intra-procedural guidance of cardiac interventions.

20.
Int J Mol Sci ; 24(2)2023 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-36674633

RESUMO

Coronary heart disease (CHD), one of the leading causes of disability and death worldwide, is a multifactorial disease whose early diagnosis is demanding. Thus, biomarkers predicting the occurrence of this pathology are of great importance from a clinical and therapeutic standpoint. By means of a pilot study on peripheral blood cells (PBMCs) of subjects with no coronary lesions (CTR; n = 2) and patients with stable CAD (CAD; n = 2), we revealed 61 differentially methylated regions (DMRs) (18 promoter regions, 24 genes and 19 CpG islands) and 14.997 differentially methylated single CpG sites (DMCs) in CAD patients. MiRNA-seq results displayed a peculiar miRNAs profile in CAD patients with 18 upregulated and 32 downregulated miRNAs (FC ≥ ±1.5, p ≤ 0.05). An integrated analysis of genome-wide DNA methylation and miRNA-seq results indicated a significant downregulation of hsa-miR-200c-3p (FCCAD = −2.97, p ≤ 0.05) associated to the hypermethylation of two sites (genomic coordinates: chr12:7073122-7073122 and chr12:7072599-7072599) located intragenic to the miR-200c/141 genomic locus (encoding hsa-miR-200c-3p) (p-value = 0.009) in CAD patients. We extended the hsa-miR-200c-3p expression study in a larger cohort (CAD = 72, CTR = 24), confirming its reduced expression level in CAD patients (FCCAD = −2; p = 0.02). However, when we analyzed the methylation status of the two CpG sites in the same cohort, we failed to identify significant differences. A ROC curve analysis showed good performance of hsa-miR-200c-3p expression level (AUC = 0.65; p = 0.02) in distinguishing CAD from CTR. Moreover, we found a significant positive correlation between hsa-miR-200c-3p expression and creatinine clearance (R2 = 0.212, p < 0.005, Pearson r = 0.461) in CAD patients. Finally, a phenotypic correlation performed in the CAD group revealed lower hsa-miR-200c-3p expression levels in CAD patients affected by dyslipidemia (+DLP, n = 58) (p < 0.01). These results indicate hsa-miR-200c-3p as potential epi-biomarker for the diagnosis and clinical progression of CAD and highlight the importance of deeper studies on the expression of this miRNA to understand its functional role in coronary artery disease development.


Assuntos
Doença da Artéria Coronariana , Dislipidemias , MicroRNAs , Humanos , Doença da Artéria Coronariana/genética , Regulação para Baixo/genética , Projetos Piloto , Perfilação da Expressão Gênica/métodos , MicroRNAs/metabolismo , Biomarcadores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA