Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 244
Filtrar
1.
Urology ; 2024 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-39293672

RESUMO

Lyndon Baines Johnson, the 36th president of the United States, was troubled with kidney stones for most of his adult life. Three times during his political career, he required either endoscopic or open surgical removal of stones. This review will highlight the symptomatic presentation of his stones, his nephrolithiasis' effect on his political career, and the methods used and reasoning for treating his nephrolithiasis.

2.
J Urol ; 212(4): 588-589, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39254127
3.
World J Urol ; 42(1): 329, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38753120

RESUMO

PURPOSE: To define a peak force of insertion (PFOI) threshold for ureteral damage during ureteral access sheath (UAS) placement on an experimental ureteral orifice model. METHODS: A specially designed water tank using 2 laparoscopic 5 mm ports and 2 different size (10 Fr and 8 Fr) sealing cap adaptors (SCA) as ureteral orifices was used to perform the test. A 10-12 Fr UAS was fixed to a load cell and the force of insertion (FOI) was continuously recorded with a digital force gauge.13 experts in the field of endourology who participated performed 3 UAS insertions. The FOI was recorded initially with 10 Fr followed by 8 Fr SCA. On the final insertion, the orifice was obstructed, leaving a 5 cm length to insert the UAS. The experts were asked to "Stop at the point they anticipate ureteral damage, and they would not proceed in real life". RESULTS: Using 10 Fr SCA the PFOI was 2.12 ± 0.58 Newton (N) (range:1.48-3.48) while 8 Fr SCA showed a PFOI 5.76 ± 0.96 N (range:4.05-7.35). Six of the experts, said they would stop proceeding when they reached above 5.1 N. Three experts had PFOI < 5.1 N and the other 4 stated they would go with PFOIs of 5.88, 6.16, 6.69 and 7.35 N when using SCA of 8 Fr.The highest load they would stop proceeding had a PFOI of 6.09 ± 1.87 N (range: 2.53-10.74). CONCLUSION: The PFOI threshold for ureteral damage inserting UAS of the experts is variable. Although FOI is a subjective perception, experience suggests that ureteral injury may occur at an average of 6.05 N perceived by surgeons' tactile feedback. In-vivo measurement of UAS PFOI may confirm a threshold.


Assuntos
Ureter , Ureter/lesões , Humanos , Procedimentos Cirúrgicos Urológicos/métodos , Cirurgiões
4.
BJU Int ; 133(2): 223-230, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37942684

RESUMO

OBJECTIVES: To explore the optimal laser settings and treatment strategies for thulium fibre laser (TFL) lithotripsy, namely, those with the highest treatment efficiency, lowest thermal injury risk, and shortest procedure time. MATERIALS AND METHODS: An in vitro kidney model was used to assess the efficacy of TFL lithotripsy in the upper calyx. Stone ablation experiments were performed on BegoStone phantoms at different combinations of pulse energy (EP ) and frequency (F) to determine the optimal settings. Temperature changes and thermal injury risks were monitored using embedded thermocouples. Experiments were also performed on calcium oxalate monohydrate (COM) stones to validate the optimal settings. RESULTS: High EP /low F settings demonstrated superior treatment efficiency compared to low EP /high F settings using the same power. Specifically, 0.8 J/12 Hz was the optimal setting, resulting in a twofold increase in treatment efficiency, a 39% reduction in energy expenditure per unit of ablated stone mass, a 35% reduction in residual fragments, and a 36% reduction in total procedure time compared to the 0.2 J/50 Hz setting for COM stones. Thermal injury risk assessment indicated that 10 W power settings with high EP /low F combinations remained below the threshold for tissue injury, while higher power settings (>10 W) consistently exceeded the safety threshold. CONCLUSIONS: Our findings suggest that high EP /low F settings, such as 0.8 J/12 Hz, are optimal for TFL lithotripsy in the treatment of COM stones. These settings demonstrated significantly improved treatment efficiency with reduced residual fragments compared to conventional settings while keeping the thermal dose below the injury threshold. This study highlights the importance of using the high EP /low F combination with low power settings, which maximizes treatment efficiency and minimizes potential thermal injury. Further studies are warranted to determine the optimal settings for TFL for treating kidney stones with different compositions.


Assuntos
Cálculos Renais , Lasers de Estado Sólido , Litotripsia a Laser , Humanos , Túlio , Litotripsia a Laser/efeitos adversos , Litotripsia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Cálculos Renais/terapia , Rim
5.
Urolithiasis ; 51(1): 124, 2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37917225

RESUMO

To investigate stone ablation characteristics of thulium fiber laser (TFL), BegoStone phantoms were spot-treated in water at various fiber tip-to-stone standoff distances (SDs, 0.5 ~ 2 mm) over a broad range of pulse energy (Ep, 0.2 ~ 2 J), frequency (F, 5 ~ 150 Hz), and power (P, 10 ~ 30 W) settings. In general, the ablation speed (mm3/s) in BegoStone decreased with SD and increased with Ep, reaching a peak around 0.8 ~ 1.0 J. Additional experiments with calcium phosphate (CaP), uric acid (UA), and calcium oxalate monohydrate (COM) stones were conducted under two distinctly different settings: 0.2 J/100 Hz and 0.8 J/12 Hz. The concomitant bubble dynamics, spark generation and pressure transients were analyzed. Higher ablation speeds were consistently produced at 0.8 J/12 Hz than at 0.2 J/100 Hz, with CaP stones most difficult yet COM and UA stones easier to ablate. Charring was mostly observed in CaP stones at 0.2 J/100 Hz, accompanied by strong spark-generation, explosive combustion, and diminished pressure transients, but not at 0.8 J/12 Hz. By treating stones in parallel fiber orientation and leveraging the proximity effect of a ureteroscope, the contribution of bubble collapse to stone ablation was found to be substantial (16% ~ 59%) at 0.8 J/12 Hz, but not at 0.2 J/100 Hz. Overall, TFL ablation efficiency is significantly better at high Ep/low F setting, attributable to increased cavitation damage with less char formation.


Assuntos
Terapia a Laser , Lasers de Estado Sólido , Litotripsia a Laser , Cálculos Urinários , Humanos , Cálculos Urinários/cirurgia , Túlio , Litotripsia a Laser/efeitos adversos , Oxalato de Cálcio
6.
J Endourol ; 37(8): 914-920, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37300481

RESUMO

Objective: Low energy and high frequency settings are used in stone dusting for holmium lasers. Such settings may not be optimal for thulium fiber laser (TFL). With the seemingly endless combination of settings, we aim to provide guidance to the practicing urologists and assess the efficiency of the TFL platform in an automated in vitro "dusting model." Materials/Methods: Three experimental setups were designed to investigate stone dusting produced by an IPG Photonics TLR-50 W TFL system using 200 µm fiber and soft BegoStone phantoms. The most popular 10 and 20 W dusting settings among endourologist familiar with TFL were evaluated. We directly compared short pulse (SP) vs long pulse (LP) mode using various combinations of pulse energy (Ep) and pulse frequency (F). Thereafter, we tested the 10 and 20 W settings and compared them among each other to elucidate the most efficient settings at each power. Treatments were performed under the same total laser energy delivered to the stone at four different standoff distances (SDs) with a clinically relevant scanning speed of either 1 or 2 mm/sec. Ablation volumes were quantified by optical coherence tomography to assess stone dusting efficiency. Fragment size after ablation at different pulse energies was evaluated by sieving and evaluating under a microscope after treatment. Results: Overall, SP provided greater ablation volume when compared with LP. Our dusting efficiency model demonstrated that the maximum stone ablation was achieved at the combination of high energy/low frequency settings (p < 0.005) and at a SD of 0.2 mm. At all tested pulse energies, no stone phantoms were broken into fragments >1 mm. Conclusions: During stone dusting with TFL, SP offers superior ablation to LP settings. Optimal dusting at clinically relevant scanning speeds of 1 and 2 mm/sec occurs at high energy/low frequency settings. Thulium lithotripsy with high Ep does not result in increased fragment size.


Assuntos
Cálculos Renais , Lasers de Estado Sólido , Litotripsia a Laser , Cálculos Urinários , Humanos , Litotripsia a Laser/métodos , Túlio/uso terapêutico , Cálculos Urinários/cirurgia , Cálculos Renais/terapia , Lasers de Estado Sólido/uso terapêutico , Hólmio
8.
World J Mens Health ; 41(3): 631-639, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36047079

RESUMO

PURPOSE: Prostate cancer (PCa) screening can lead to potential over-diagnosis/over-treatment of indolent cancers. There is a need to optimize practices to better risk-stratify patients. We examined initial longitudinal outcomes of mid-life men with an elevated baseline prostate-specific antigen (PSA) following initiation of a novel screening program within a system-wide network. MATERIALS AND METHODS: We assessed our primary care network patients ages 40 to 49 years with a PSA measured following implementation of an electronic health record screening algorithm from 2/2/2017-2/21/2018. The multidisciplinary algorithm was developed taking factors including age, race, family history, and PSA into consideration to provide a personalized approach to urology referral to be used with shared decision-making. Outcomes of men with PSA ≥1.5 ng/mL were evaluated through 7/2021. Statistical analyses identified factors associated with PCa detection. Clinically significant PCa (csPCa) was defined as Gleason Grade Group (GGG) ≥2 or GGG1 with PSA ≥10 ng/mL. RESULTS: The study cohort contained 564 patients, with 330 (58.5%) referred to urology for elevated PSA. Forty-nine (8.7%) underwent biopsy; of these, 20 (40.8%) returned with PCa. Eleven (2.0% of total cohort and 55% of PCa diagnoses) had csPCa. Early referral timing (odds ratio [OR], 4.58) and higher PSA (OR, 1.07) were significantly associated with PCa at biopsy on multivariable analysis (both p<0.05), while other risk factors were not. Referred patients had higher mean PSAs (2.97 vs. 1.98, p=0.001). CONCLUSIONS: Preliminary outcomes following implementation of a multidisciplinary screening algorithm identified PCa in a small, important percentage of men in their forties. These results provide insight into baseline PSA measurement to provide early risk stratification and detection of csPCa in patients with otherwise extended life expectancy. Further follow-up is needed to possibly determine the prognostic significance of such mid-life screening and optimize primary care physician-urologist coordination.

9.
Eur Urol Focus ; 9(3): 513-523, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36435718

RESUMO

Different international associations have proposed their own guidelines on urolithiasis. However, the focus is primarily on an overview of the principles of urolithiasis management rather than step-by-step technical details for the procedure. The International Alliance of Urolithiasis (IAU) is releasing a series of guidelines on the management of urolithiasis. The current guideline on shockwave lithotripsy (SWL) is the third in the IAU guidelines series and provides a clinical framework for urologists and technicians performing SWL. A total of 49 recommendations are summarized and graded, covering the following aspects: indications and contraindications; preoperative patient evaluation; preoperative medication; prestenting; intraoperative analgesia or anesthesia; intraoperative position; stone localization and monitoring; machine and energy settings; intraoperative lithotripsy strategies; auxiliary therapy following SWL; evaluation of stone clearance; complications; and quality of life. The recommendations, tips, and tricks regarding SWL procedures summarized here provide important and necessary guidance for urologists along with technicians performing SWL. PATIENT SUMMARY: For kidney and urinary stones of less than 20 mm in size, shockwave lithotripsy (SWL) is an approach in which the stone is treated with shockwaves applied to the skin, without the need for surgery. Our recommendations on technical aspects of the procedure provide guidance for urologists and technicians performing SWL.


Assuntos
Litotripsia , Cálculos Urinários , Urolitíase , Humanos , Qualidade de Vida , Urolitíase/terapia , Cálculos Urinários/terapia , Rim , Litotripsia/métodos
10.
BJU Int ; 131(2): 153-164, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35733358

RESUMO

OBJECTIVES: To set out the second in a series of guidelines on the treatment of urolithiasis by the International Alliance of Urolithiasis that concerns retrograde intrarenal surgery (RIRS), with the aim of providing a clinical framework for urologists performing RIRS. MATERIALS AND METHODS: After a comprehensive search of RIRS-related literature published between 1 January 1964 and 1 October 2021 from the PubMed database, systematic review and assessment were performed to inform a series of recommendations, which were graded using modified GRADE methodology. Additionally, quality of evidence was classified using a modification of the Oxford Centre for Evidence-Based Medicine Levels of Evidence system. Finally, related comments were provided. RESULTS: A total of 36 recommendations were developed and graded that covered the following topics: indications and contraindications; preoperative imaging; preoperative ureteric stenting; preoperative medications; peri-operative antibiotics; management of antithrombotic therapy; anaesthesia; patient positioning; equipment; lithotripsy; exit strategy; and complications. CONCLUSION: The series of recommendations regarding RIRS, along with the related commentary and supporting documentation, offered here should help provide safe and effective performance of RIRS.


Assuntos
Cálculos Renais , Litotripsia , Ureter , Urolitíase , Humanos , Cálculos Renais/cirurgia , Ureteroscopia/métodos , Urolitíase/cirurgia , Litotripsia/métodos , Resultado do Tratamento
12.
J Endourol ; 36(9): 1161-1167, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35331002

RESUMO

Background: There is a need to reliably render urolithiasis patients completely stone free with minimal morbidity. We report on the initial safety and feasibility with steerable ureteroscopic renal evacuation (SURE) in a prospective study using basket extraction as a comparison. Materials and Methods: A pilot randomized controlled study was conducted comparing SURE with basket extraction postlaser lithotripsy. SURE is performed using the CVAC™ Aspiration System, a steerable catheter (with introducer). The safety and feasibility of steering CVAC throughout the collecting system under fluoroscopy and aspirating stone fragments as it was designed to do were evaluated. Fluoroscopy time, change in hemoglobin, adverse events through 30 days, total and proportion of stone volume removed at 1 day, intraoperative stone removal rate, and stone-free rate (SFR) at 30 days through CT were compared. Results: Seventeen patients were treated (n = 9 SURE, n = 8 Basket). Baseline demographics and stone parameters were not significantly different between groups. One adverse event occurred in each group (self-limiting ileus for SURE and urinary tract infection for Basket). No mucosal injury and no contrast extravasation were observed in either group. The CVAC catheter was steered throughout the collecting system and aspirated fragments. There was no significant difference in fluoroscopy time, procedure time, change in hemoglobin, or stone removal rate between groups. SURE removed more and a greater proportion of stone volume at day 1 vs baskets (202 mm3 vs 91 mm3, p < 0.01 and 84% vs 56%, p = 0.022). SURE achieved 100% SFR at 30 days vs 75% for baskets, although this difference was not statistically significant (p = 0.20). Conclusions: This initial study suggests SURE is safe, feasible, and may be more effective in stone removal postlaser lithotripsy compared to basketing. More development is needed, and larger clinical studies are underway.


Assuntos
Cálculos Ureterais , Urolitíase , Estudos de Viabilidade , Humanos , Estudos Prospectivos , Resultado do Tratamento , Cálculos Ureterais/cirurgia , Ureteroscopia/métodos
13.
J Endourol ; 36(5): 674-683, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34806899

RESUMO

Objective: To investigate the mechanism of stone dusting in Holmium (Ho): YAG laser lithotripsy (LL). Materials and Methods: Cylindrical BegoStone samples (6 × 6 mm, H × D) were treated in water using a clinical Ho:YAG laser lithotripter in dusting mode (0.2-0.4 J with 70-78 µs in pulse duration, 20 Hz) at various fiber tip to stone standoff distances (SD = 0, 0.5, and 1 mm). Stone damage craters were quantified by optical coherence tomography and bubble dynamics were captured by high-speed video imaging. To differentiate the contribution of cavitation vs thermal ablation to stone damage, three additional experiments were performed. First, presoaked wet stones were treated in air to assess stone damage without cavitation. Second, the laser fiber was advanced at various offset distances (OSD = 0.25, 1, 2, 3, and 10 mm) from the tip of a flexible ureteroscope to alter the dynamics of bubble collapse. Third, stones were treated with parallel fiber to minimize photothermal damage while isolating the contribution of cavitation to stone damage. Results: Treatment in water resulted in 2.5- to 90-fold increase in stone damage compared with those produced in air where thermal ablation dominates. With the fiber tip placed at OSD = 0.25 mm, the collapse of the bubble was distracted away from the stone surface by the ureteroscope tip, leading to significantly reduced stone damage compared with treatment without the scope or with scope at large OSD of 3-10 mm. The average crater volume produced by parallel fiber orientation at 0.2 J after 100 pulses, where cavitation is the dominant mechanism of stone damage, was comparable with those produced by using perpendicular fiber orientation within SD = 0.25-1 mm. Conclusion: Cavitation plays a dominant role over photothermal ablation in stone dusting during short pulse Ho:YAG LL when 10 or more pulses are delivered to the same location.


Assuntos
Cálculos , Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Hólmio , Humanos , Lasers de Estado Sólido/uso terapêutico , Litotripsia a Laser/métodos , Água
14.
J Endourol ; 36(1): 13-21, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34235971

RESUMO

Introduction: Office cystoscopy is one of the most frequently performed procedures by a urologist. However, single-use cystoscopes remain quite undeveloped. Ambu® has developed single-use broncoscopes, rhinolaryngoscopes, and duodenoscopes. Recently, they released a single-use cystoscope. In this study, we performed a benchtop and an initial clinical assessment of the Ambu aScope™ (4) Cysto (aS4C) single-use cystoscope. Materials and Methods: Ten new, never-used aS4C single-use cystoscopes were assessed for optical performance, maximal tip flexion, and irrigation flow rate with empty working channel, 365 µm laser fiber, 0.035 in hydrophilic-tipped wire, 1.9F nitinol basket, and a 1.8 mm flexible stent grasper. All cystoscopes were then fully flexed 25 times in each direction, and maximal flexion angles were remeasured with and without instruments. Optical resolution, distortion, and depth of field were measured and compared with our reusable digital flexible cystoscopes. Assessment of clinical use was performed for inpatient bedside procedures using a Likert feedback survey and the NASA Task Load Index. Results: Maximal upward flexion exceeded 200° and 160° for all working instruments in upward and downward flexion. Downward flexion demonstrated different flexion between instrument groups in pre- and postcycling (p < 0.001). There was no clinical difference between the pre- and postcycling flexion. Flow rate decreased with increasing working instrument size (p < 0.001). The Olympus HD cystoscope resolution was superior at 3 and 5 mm distance, but not at other distances. The Ambu scope was superior to the Olympus SD scope at all distances except 3 mm. The aS4C had higher Likert scale survey scores for clinical use. Conclusions: The new Ambu single-use cystoscope demonstrates good flexion across instruments and comparable optics with reusable cystoscopes. In addition, initial inpatient bedside use of the aS4C and Monitor system compares favorably with the Olympus reusable cystoscope. Further testing in clinical scenarios such as hematuria, urothelial carcinoma, and operative endoscopy is warranted.


Assuntos
Carcinoma de Células de Transição , Neoplasias da Bexiga Urinária , Cistoscópios , Cistoscopia/métodos , Desenho de Equipamento , Humanos
15.
J Endourol ; 36(1): 29-37, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34269626

RESUMO

Introduction: Manipulation of Holmium:Yttrium-Aluminum-Garnet laser parameters such as pulse energy (PE), frequency, and duration can impact laser lithotripsy ablation efficiency. In 2017, Lumenis introduced Moses™ Technology, which uses pulse modulation to enhance the delivery of energy from fiber to stone as well as to minimize stone retropulsion. Since the introduction of Moses Technology, other companies have brought additional pulse modulation concepts to market. The purpose of this in vitro study is to compare the pulse characteristics and stone ablation efficiency of Lumenis Moses Technology with Quanta's Vapor Tunnel™. Materials and Methods: Submerged BegoStone phantoms were systematically ablated using either the Lumenis Moses Pulse 120H or the Quanta Litho 100 clinical laser system. Two PEs (0.4 and 1 J), three fiber-stone standoff distances (SDs) (0.5, 1, 2 mm), and all available pulse duration and modulation modes for each laser were tested in combination. Fiber speed was adjusted to scan across the stone surface at either 1 or 10 pulses/mm to form single pulse craters or an ablation trough, respectively. Volumes of single craters and 1 mm trough segments were imaged and quantified using optical coherence tomography. Results: Ablation volumes decreased with decreasing PE and increasing SD. Statistically significant variability was seen between pulse types (PT) at every tested parameter set. Among pulse modulation modes, Moses Distance (MD) was superior at 0.5 mm in all testing and at 2 mm in trough testing. Vapor Tunnel (VT) was superior in 2 mm single crater testing. All modulated pulses performed similarly at 1 mm. Conclusions: In this benchtop model of laser lithotripsy, stone ablation was significantly impacted by PT. MD demonstrated superior or noninferior stone ablation at most tested parameters. VT maintained its efficacy the best as SD increased. Future work should focus on the mechanistic differences of these modes relative to other traditional laser pulse modes.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Alumínio , Hólmio , Humanos , Litotripsia a Laser/métodos , Ítrio
17.
J Endourol ; 35(6): 860-870, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33514285

RESUMO

Purpose: Although cavitation during laser lithotripsy (LL) contributes to the Moses effect, the impact of cavitation on stone damage is less clear. Using different laser settings, we investigate the role of cavitation bubbles in energy delivery and stone damage. Materials and Methods: The role of cavitation in laser energy delivery was characterized by using photodetector measurements synced with high-speed imaging for laser pulses of varying durations. BegoStone samples were treated with the laser fiber oriented perpendicularly in contact with the stone in water or in air to assess the impact of cavitation on crater formation. Crater volume and geometry were quantified by using optical coherence tomography. Further, the role of cavitation in stone damage was elucidated by treatment in water with the fiber oriented parallel to the stone surface and by photoelastic imaging. Results: Longer pulse durations resulted in higher energy delivery but smaller craters. Stones treated in water resulted in greater volume, wider yet shallower craters compared with those treated in air. Stones treated with the parallel fiber showed crater formation after 15 pulses, confirmed by high-speed imaging of the bubble collapse with the resultant stress field captured by photoelastic imaging. Conclusions: Despite improved energy delivery, the longer pulse mode produced smaller crater volume, suggesting additional processes secondary to photothermal ablation are involved in stone damage. Our critical observations of the difference in stone damage treated in water vs in air, combined with the crater formation by parallel fiber, suggest that cavitation is a contributor to stone damage during LL.


Assuntos
Cálculos Renais , Litotripsia a Laser , Litotripsia , Humanos , Cálculos Renais/cirurgia , Litotripsia/efeitos adversos , Litotripsia a Laser/efeitos adversos
18.
J Gen Intern Med ; 36(1): 92-99, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32875501

RESUMO

BACKGROUND: Implementation methods of risk-stratified cancer screening guidance throughout a health care system remains understudied. OBJECTIVE: Conduct a preliminary analysis of the implementation of a risk-stratified prostate cancer screening algorithm in a single health care system. DESIGN: Comparison of men seen pre-implementation (2/1/2016-2/1/2017) vs. post-implementation (2/2/2017-2/21/2018). PARTICIPANTS: Men, aged 40-75 years, without a history of prostate cancer, who were seen by a primary care provider. INTERVENTIONS: The algorithm was integrated into two components in the electronic health record (EHR): in Health Maintenance as a personalized screening reminder and in tailored messages to providers that accompanied prostate-specific antigen (PSA) results. MAIN MEASURES: Primary outcomes: percent of men who met screening algorithm criteria; percent of men with a PSA result. Logistic repeated measures mixed models were used to test for differences in the proportion of individuals that met screening criteria in the pre- and post-implementation periods with age, race, family history, and PSA level included as covariates. KEY RESULTS: During the pre- and post-implementation periods, 49,053 and 49,980 men, respectively, were seen across 26 clinics (20.6% African American). The proportion of men who met screening algorithm criteria increased from 49.3% (pre-implementation) to 68.0% (post-implementation) (p < 0.001); this increase was observed across all races, age groups, and primary care clinics. Importantly, the percent of men who had a PSA did not change: 55.3% pre-implementation, 55.0% post-implementation. The adjusted odds of meeting algorithm-based screening was 6.5-times higher in the post-implementation period than in the pre-implementation period (95% confidence interval, 5.97 to 7.05). CONCLUSIONS: In this preliminary analysis, following implementation of an EHR-based algorithm, we observed a rapid change in practice with an increase in screening in higher-risk groups balanced with a decrease in screening in low-risk groups. Future efforts will evaluate costs and downstream outcomes of this strategy.


Assuntos
Sistemas de Apoio a Decisões Clínicas , Neoplasias da Próstata , Adulto , Idoso , Algoritmos , Detecção Precoce de Câncer , Humanos , Masculino , Programas de Rastreamento , Pessoa de Meia-Idade , Atenção Primária à Saúde , Antígeno Prostático Específico , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/epidemiologia
19.
J Endourol ; 35(6): 755-760, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33207957

RESUMO

Introduction: Single-use flexible ureteroscopes are an increasingly popular alternative to reusable ureteroscopes. In this study, we performed a benchtop examination of the physical and optical properties of the new Dornier Axis™ (Webling, Germany) single-use ureteroscope. Methods: Ten new, never-used Dornier Axis ureteroscopes were assessed for optical performance, maximal tip deflection, and irrigation flow rate with an empty working channel and with insertion of 200 and 365 µm laser fibers, and a 1.9F nitinol basket. All ureteroscopes were then fully deflected 100 times in each direction, and maximal deflection angles were re-measured with and without instruments in the working channel. All measurements were performed in duplicate. In vitro optical testing for resolution, image distortion, and depth of field was performed and compared vs the LithoVue™ (Boston Scientific, Marlborough, MA) single-use ureteroscope. Statistical analyses using paired Wilcoxon rank-sum tests and Kruskal-Wallis multiple-group comparison tests were performed in R. Results: Median maximal deflection angles exceeded 300° in both directions before and after 100 full deflection cycles for all groups except the 365 µm laser fiber group. After 100 deflection cycles, there was no change in the majority of working instruments, except a decrease in upward flexion with an empty channel and 200 µm Moses™ laser fiber, and downward flexion with 200 µm Flexiva™ laser fiber (all <10°). After excluding the 365 µm fiber, there was no difference in multi-group comparison for upward and downward flexion pre- and post-cycling. Median flow rate through an empty channel was 48.0 mL/min, and it decreased significantly with all used instruments (p < 0.001). Compared with the LithoVue, the Axis demonstrated superior resolution at all tested distances and less distortion. Conclusions: The new Dornier Axis single-use ureteroscope demonstrates excellent tip deflection, which remains unchanged after 100 manual flexions in each direction. The Axis also demonstrates superior optical performance compared with the LithoVue in benchtop testing.


Assuntos
Ureteroscópios , Ureteroscopia , Desenho de Equipamento , Alemanha , Humanos , Técnicas In Vitro
20.
J Endourol ; 35(6): 903-907, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-27981862

RESUMO

Introduction: A novel single-use flexible ureteroscope promises the optical characteristics and maneuverability of a reusable fourth-generation flexible ureteroscope. In this study, the LithoVue Single-Use Digital flexible ureteroscope was directly compared with contemporary reusable flexible ureteroscopes, with regard to optics, deflection, and irrigation flow. Methods: Three flexible ureteroscopes such as the LithoVue (Single Use; Boston Scientific), Flex-Xc (Karl Storz, Germany), and Cobra (Richard Wolf, Germany) were assessed in vitro for image resolution, distortion, color representation, grayscale imaging, field of view, and depth of field. Ureteroscope deflection was tested with an empty channel followed by placement of a 200 µm laser fiber and a 1.9F wire basket, a 2.0F nanoelectric pulse lithotripsy (NPL) probe, and a 2.4F NPL probe. Ureteroscope irrigation flow was measured using normal saline at 100 cm, with an empty channel followed by a 200 µm laser fiber, a 1.9F wire basket and a 2.0F NPL probe. Results: The LithoVue showed the largest field of view, with excellent resolution, image distortion, and depth of field. No substantial difference was demonstrated in color reproducibility or in the discernment of grayscales between ureteroscopes. The LithoVue maintained full deflection ability with all instruments in the working channel, although the Flex-Xc and Cobra ureteroscopes showed loss of deflection ranging from 2° to 27°, depending on the instrument placed. With an empty channel, the LithoVue showed an absolute flow rate similar to the Flex-Xc ureteroscope (p = 0.003). It maintained better flow with instruments in the channel than the Flex-Xc ureteroscope. The Cobra ureteroscope has a separate 3.3F instrument channel, keeping flow rates the same with instrument insertion. Conclusion: The LithoVue Single-Use Digital ureteroscope has comparable optical capabilities, deflection, and flow, making it a viable alternative to standard reusable fourth-generation flexible digital and fiberoptic ureteroscopes.


Assuntos
Ureteroscópios , Ureteroscopia , Desenho de Equipamento , Alemanha , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA