Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
ASAIO J ; 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38776488

RESUMO

Patients undergoing veno-arterial extracorporeal membrane oxygenation (VA-ECMO) typically suffer from cardiogenic pulmonary edema and lung atelectasis, which can exacerbate right ventricular (RV) dysfunction through an increase in lung elastance and RV afterload. Invasive mechanical ventilation settings, and positive end-expiratory pressure (PEEP) in particular, can help to improve RV performance by optimizing lung recruitment and minimizing alveolar overdistention. In this report, we present a VA-ECMO supported patient in whom in vivo RV pressure-volume (PV) loops were measured during a decremental PEEP trial, leading to the identification of an optimum PEEP level from a cardio-respiratory viewpoint. This innovative approach of tailoring mechanical ventilation settings according to cardio-respiratory physiology through in vivo RV PV loops may provide a novel way to optimize hemodynamics and patient outcomes.

2.
Biology (Basel) ; 13(1)2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38275731

RESUMO

Knowing cardiac physiology is essential for health care professionals working in the cardiovascular field. Pressure-volume loops (PVLs) offer a unique understanding of the myocardial working and have become pivotal in complex pathophysiological scenarios, such as profound cardiogenic shock or when mechanical circulatory supports are implemented. This review provides a comprehensive summary of the left and right ventricle physiology, based on the PVL interpretation.

3.
J Intensive Care Med ; 39(5): 420-428, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37926984

RESUMO

Purpose: This study aimed to investigate the effects of inspired oxygen fraction (FiO2) and positive end-expiratory pressure (PEEP) on gas exchange in mechanically ventilated patients with COVID-19. Methods: Two FiO2 (100%, 40%) were tested at 3 decreasing levels of PEEP (15, 10, and 5 cmH2O). At each FiO2 and PEEP, gas exchange, respiratory mechanics, hemodynamics, and the distribution of ventilation and perfusion were assessed with electrical impedance tomography. The impact of FiO2 on the intrapulmonary shunt (delta shunt) was analyzed as the difference between the calculated shunt at FiO2 100% (shunt) and venous admixture at FiO2 40% (venous admixture). Results: Fourteen patients were studied. Decreasing PEEP from 15 to 10 cmH2O did not change shunt (24 [21-28] vs 27 [24-29]%) or venous admixture (18 [15-26] vs 23 [18-34]%) while partial pressure of arterial oxygen (FiO2 100%) was higher at PEEP 15 (262 [198-338] vs 256 [147-315] mmHg; P < .05). Instead when PEEP was decreased from 10 to 5 cmH2O, shunt increased to 36 [30-39]% (P < .05) and venous admixture increased to 33 [30-43]% (P < .05) and partial pressure of arterial oxygen (100%) decreased to 109 [76-177] mmHg (P < .05). At PEEP 15, administration of 100% FiO2 resulted in a shunt greater than venous admixture at 40% FiO2, ((24 [21-28] vs 18 [15-26]%, P = .005), delta shunt 5.5% (2.3-8.8)). Compared to PEEP 10, PEEP of 5 and 15 cmH2O resulted in decreased global and pixel-level compliance. Cardiac output at FiO2 100% resulted higher at PEEP 5 (5.4 [4.4-6.5]) compared to PEEP 10 (4.8 [4.1-5.5], P < .05) and PEEP 15 cmH2O (4.7 [4.5-5.4], P < .05). Conclusion: In this study, PEEP of 15 cmH2O, despite resulting in the highest oxygenation, was associated with overdistension. PEEP of 5 cmH2O was associated with increased shunt and alveolar collapse. Administration of 100% FiO2 was associated with an increase in intrapulmonary shunt in the setting of high PEEP. Trial registration: NCT05132933.


Assuntos
COVID-19 , Pneumopatias , Síndrome do Desconforto Respiratório , Humanos , Respiração Artificial , Síndrome do Desconforto Respiratório/terapia , COVID-19/complicações , COVID-19/terapia , Pulmão/diagnóstico por imagem , Respiração com Pressão Positiva/métodos , Mecânica Respiratória , Oxigênio
5.
Minerva Anestesiol ; 89(9): 773-782, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36951601

RESUMO

BACKGROUND: Extracorporeal carbon dioxide removal (ECCO2R) promotes protective ventilation in patients with acute respiratory failure, but devices with high CO2 extraction capacity are required for clinically relevant impact. This study evaluates three novel low-flow techniques based on dialysate acidification, also combined with renal replacement therapy, and metabolic control. METHODS: Eight swine were connected to a low-flow (350 mL/min) extracorporeal circuit including a dialyzer with a closed-loop dialysate circuit, and two membrane lungs on blood (MLb) and dialysate (MLd), respectively. The following 2-hour steps were performed: 1) MLb-start (MLb ventilated); 2) MLbd-start (MLb and MLd ventilated); 3) HLac (lactic acid infusion before MLd); 4) HCl-NaLac (hydrochloric acid infusion before MLd combined with renal replacement therapy and reinfusion of sodium lactate); 5) HCl-ßHB-NaLac (hydrochloric acid infusion before MLd combined with renal replacement therapy and reinfusion of sodium lactate and sodium 3-hydroxybutyrate). Caloric and fluid inputs, temperature, blood glucose and arterial carbon dioxide pressure were kept constant. RESULTS: The total MLs CO2 removal in HLac (130±25 mL/min), HCl-NaLac (130±21 mL/min) and HCl-ßHB-NaLac (124±18 mL/min) were higher compared with MLbd-start (81±15 mL/min, P<0.05) and MLb-start (55±7 mL/min, P<0.05). Minute ventilation in HLac (4.3±0.9 L/min), HCl-NaLac (3.6±0.8 L/min) and HCl-ßHB-NaLac (3.6±0.8 L/min) were lower compared to MLb-start (6.2±1.1 L/min, P<0.05) and MLbd-start (5.8±2.1 L/min, P<0.05). Arterial pH was 7.40±0.03 at MLb-start and decreased only during HCl-ßHB-NaLac (7.35±0.03, P<0.05). No relevant changes in electrolyte concentrations, hemodynamics and significant adverse events were detected. CONCLUSIONS: The three techniques achieved a significant extracorporeal CO2 removal allowing a relevant reduction in minute ventilation with a sufficient safety profile.


Assuntos
Dióxido de Carbono , Respiração Artificial , Animais , Suínos , Respiração Artificial/métodos , Lactato de Sódio , Ácido Clorídrico , Concentração de Íons de Hidrogênio , Soluções para Diálise
6.
Crit Care Med ; 50(5): e468-e476, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-35044966

RESUMO

OBJECTIVES: Extracorporeal carbon dioxide removal is used to treat patients suffering from acute respiratory failure. However, the procedure is hampered by the high blood flow required to achieve a significant CO2 clearance. We aimed to develop an ultralow blood flow device to effectively remove CO2 combined with continuous renal replacement therapy (CRRT). DESIGN: Preclinical, proof-of-concept study. SETTING: An extracorporeal circuit where 200 mL/min of blood flowed through a hemofilter connected to a closed-loop dialysate circuit. An ion-exchange resin acidified the dialysate upstream, a membrane lung to increase Pco2 and promote CO2 removal. PATIENTS: Six, 38.7 ± 2.0-kg female pigs. INTERVENTIONS: Different levels of acidification were tested (from 0 to 5 mEq/min). Two l/hr of postdilution CRRT were performed continuously. The respiratory rate was modified at each step to maintain arterial Pco2 at 50 mm Hg. MEASUREMENTS AND MAIN RESULTS: Increasing acidification enhanced CO2 removal efficiency of the membrane lung from 30 ± 5 (0 mEq/min) up to 145 ± 8 mL/min (5 mEq/min), with a 483% increase, representing the 73% ± 7% of the total body CO2 production. Minute ventilation decreased accordingly from 6.5 ± 0.7 to 1.7 ± 0.5 L/min. No major side effects occurred, except for transient tachycardia episodes. As expected from the alveolar gas equation, the natural lung Pao2 dropped at increasing acidification steps, given the high dissociation between the oxygenation and CO2 removal capability of the device, thus Pao2 decreased. CONCLUSIONS: This new extracorporeal ion-exchange resin-based multiple-organ support device proved extremely high efficiency in CO2 removal and continuous renal support in a preclinical setting. Further studies are required before clinical implementation.


Assuntos
Terapia de Substituição Renal Contínua , Animais , Dióxido de Carbono , Soluções para Diálise , Feminino , Humanos , Oxigênio , Respiração Artificial/métodos , Suínos
7.
J Exp Biol ; 211(Pt 15): 2442-9, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18626078

RESUMO

Foundresses and workers of Polistes paper wasps show slight morphological and physiological differences. However, after the emergence of the workers, the castes can be readily discriminated by their behaviour: the dominant foundress is the principal egg-layer, whereas workers perform different tasks linked to colony development. Previous studies have demonstrated in this genus that defence of the colony by the workers is more effectively carried out by a collective response elicited by venom volatiles used as alarm pheromones. In the present study, gas chromatography-mass spectrometry analyses of the venom volatiles of foundresses and workers of Polistes dominulus (Christ) show predominantly quantitative differences. Spiroacetals, mainly (E,E)-2,8-dimethyl-1,7-dioxaspiro[5.5]undecane, are significantly higher in the venom volatiles fraction of workers, whereas the amount of N-(3-methylbutyl)acetamide is almost double in foundresses. On the basis of the chemical results, behavioural assays were performed on fifteen field colonies to test the alarm response of the resident wasps to venom extracts from foundresses and workers. Our behavioural results suggest that worker venom has a stronger alarm effect on the colonies than that of the foundresses, which seems unable to elicit the complete alarm response ending with a final attack and sting. The venom volatiles of P. dominulus workers serve mainly to alarm the colony whilst those of foundresses may also be linked to additional functions related to conspecific interactions.


Assuntos
Comportamento Animal/fisiologia , Hierarquia Social , Venenos de Vespas/química , Vespas/fisiologia , Animais , Bioensaio , Análise Discriminante , Feminino , Masculino , Volatilização , Venenos de Vespas/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA