Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Pathogens ; 12(7)2023 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-37513731

RESUMO

Legionella is an opportunistic pathogen with a biphasic life cycle that occasionally infects humans. The aim of the study was to assess the distribution of virulence genes and genetic diversity among L. pneumophila isolated from water supply systems of residential buildings in Latvia. In total, 492 water samples from 200 residential buildings were collected. Identification of Legionella spp. was performed according to ISO 11731, and 58 isolates were subjected to whole-genome sequencing. At least one Legionella-positive sample was found in 112 out of 200 apartment buildings (56.0%). The study revealed extensive sequence-type diversity, where 58 L. pneumophila isolates fell into 36 different sequence types. A total of 420 virulence genes were identified, of which 260 genes were found in all sequenced L. pneumophila isolates. The virulence genes enhC, htpB, omp28, and mip were detected in all isolates, suggesting that adhesion, attachment, and entry into host cells are enabled for all isolates. The relative frequency of virulence genes among L. pneumophila isolates was high. The high prevalence, extensive genetic diversity, and the wide range of virulence genes indicated that the virulence potential of environmental Legionella is high, and proper risk management is of key importance to public health.

2.
Microorganisms ; 11(3)2023 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-36985170

RESUMO

Legionella is one of the most important waterborne pathogens that can lead to both outbreaks and sporadic cases. The majority of travel-associated Legionnaires' disease (TALD) cases are contracted during hotel stays. The aim of this study was to evaluate the prevalence and genetic diversity of Legionella spp. in hotel water supply systems in Latvia. In total, 834 hot water samples were collected from the water systems of 80 hotels in Latvia. At least one Legionella spp. positive sample was detected in 47 out of 80 hotels (58.8%). Overall, 235 out of 834 samples (28.2%) were Legionella spp. positive. The average hot water temperature in Latvian hotels was 49.8 °C. The most predominant L. pneumophila serogroup (SG) was SG3 which was found in 113 (49.8%) positive samples from 27 hotels. For 79 sequenced L. pneumophila isolates, 21 different sequence types (ST) were obtained, including 3 new types-ST2582, ST2579, and ST2580. High Legionella contamination and high genetic diversity were found in the hotel water supply systems in Latvia, which, together with the insufficient hot water temperature, may indicate that the lack of regulation and control measures may promote the proliferation of Legionella.

3.
Transbound Emerg Dis ; 67(6): 2615-2629, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32372476

RESUMO

In 2014, African swine fever (ASF) emerged in Latvia for the first time. The majority of cases appeared in wild boar, but the presence of ASF in these animals constitutes a permanent threat to domestic pig holdings. Recent studies have shown an increase in serologically positive and a decrease in PCR-positive ASF cases in wild boar, possibly indicating a decline of ASF incidence. We aimed to investigate the course of the ASF epidemic in wild boar in Latvia, thus attaining further insights into the ASF epidemiology in this country with the goal of assessing the stage of the epidemic. Latvian ASF surveillance data of wild boar were utilized to estimate the seroprevalence and ASF virus (ASFV) prevalence in the wild boar population. Prevalence estimates were obtained for both the eastern and western part of the country and in addition for the 2014/2015 to 2018/2019 hunting seasons. Moreover, prevalence estimates for three different age classes were calculated. An increase in serologically positive yet PCR-negative wild boar samples from active surveillance was identified over time. When comparing the age groups, wild boar younger than one year displayed the ASFV prevalence to be higher than the seroprevalence, whereas older animals shared higher seroprevalence estimates. These findings support the assumption that only a small proportion of affected animals survive an infection, leading to an accumulation of their numbers over time. As a result, ASF elimination in a country with an infected wild boar population could possibly be achieved, if effective wild boar population management and surveillance is maintained and combined with the detection and removal of wild boar carcasses to reduce the viral load in the environment. In addition, the wild boar population should be kept as small as possible to break the ASFV infection cycle.


Assuntos
Vírus da Febre Suína Africana/isolamento & purificação , Febre Suína Africana/epidemiologia , Epidemias/veterinária , Febre Suína Africana/virologia , Animais , Feminino , Letônia/epidemiologia , Masculino , Prevalência , Estudos Soroepidemiológicos , Sus scrofa , Suínos
4.
Medicina (Kaunas) ; 55(8)2019 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-31443316

RESUMO

Background and Objectives: Legionella is one of the most important water-related pathogens. Inside the water supply systems and the biofilms, Legionella interact with other bacteria and free-living amoeba (FLA). Several amoebas may serve as hosts for bacteria in aquatic systems. This study aimed to investigate the co-occurrence of Legionella spp. and FLA in drinking water supply systems. Materials and Methods: A total of 268 water samples were collected from apartment buildings, hotels, and public buildings. Detection of Legionella spp. was performed in accordance with ISO 11731:2017 standard. Three different polymerase chain reaction (PCR) protocols were used to identify FLA. Results: Occurrence of Legionella varied from an average of 12.5% in cold water samples with the most frequent occurrence observed in hot water, in areas receiving untreated groundwater, where 54.0% of the samples were Legionella positive. The occurrence of FLA was significantly higher. On average, 77.2% of samples contained at least one genus of FLA and, depending on the type of sample, the occurrence of FLA could reach 95%. In the samples collected during the study, Legionella was always isolated along with FLA, no samples containing Legionella in the absence of FLA were observed. Conclusions: The data obtained in our study can help to focus on the extensive distribution, close interaction, and long-term persistence of Legionella and FLA. Lack of Legionella risk management plans and control procedures may promote further spread of Legionella in water supply systems. In addition, the high incidence of Legionella-related FLA suggests that traditional monitoring methods may not be sufficient for Legionella control.


Assuntos
Amoeba/crescimento & desenvolvimento , Água Potável/microbiologia , Monitoramento Ambiental , Legionella/crescimento & desenvolvimento , Microbiologia da Água , Abastecimento de Água
5.
Int J Environ Res Public Health ; 13(1): ijerph13010058, 2015 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-26703696

RESUMO

Continuous environmental exposure of humans to Legionella may induce immune responses and generation of antibodies. The aim of this study was to investigate the seroprevalence of Legionella pneumophila serogroups (SG) 1-6 in the general healthy population and identify the associated host-related and environmental risk factors. L. pneumophila SG 1-6 seroprevalence among a total of 2007 blood samples collected from healthy donors was 4.8%. Seroprevalence was higher in women (5.9%) than men (3.3%) and in areas with a larger number of inhabitants, ranging from 3.5% in rural regions to 6.8% in the capital, Riga. Blood samples from inhabitants of apartment buildings tested positive for L. pneumophila in more cases (5.8%) compared to those from inhabitants of single-family homes (2.7%). Residents of buildings with a municipal hot water supply system were more likely to be seropositive for L. pneumophila (OR = 3.16, 95% CI 1.26-7.91). Previous episodes of fever were additionally identified as a risk factor (OR = 2.42, 95% CI 1.43-4.1). In conclusion, centralized hot water supply, female gender and previous episodes of fever were determined as the main factors associated with L. pneumophila seropositivity in our study population.


Assuntos
Doadores de Sangue/estatística & dados numéricos , Doença dos Legionários/epidemiologia , Adolescente , Adulto , Idoso , Feminino , Humanos , Letônia/epidemiologia , Doença dos Legionários/etiologia , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Estudos Soroepidemiológicos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA