Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Orthop Surg ; 15(6): 1694-1701, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37073103

RESUMO

BACKGROUND: Intradural disc herniation(IDH) caused by trauma is a rare type of disease,which is difficult to diagnose clinically and is easily misdiagnosed. We received a patient with the disease, reported the case to share the process of diagnosis and treatment and put forward our own opinions, so as to increase the probability of correct diagnosis. CASE PRESENTATION: We report the case of a 48-year-old male who fell from a scaffold at a height of 2 m. Later, he developed low back pain, restricted movement, numbness and hyperalgesia of the lower left limb, and decreased left muscle strength. He was diagnosed with IDH. Treatment with posterior decompression and intramedullary decompression with pedicle screw internal fixation was performed. His postoperative course was uneventful, and he underwent regular follow up for 1 year. Good neurologic symptom improvement was achieved. CONCLUSIONS: IDH is rare, and comprehensive consideration and film reading can improve the correct diagnosis rate. Accurate diagnosis and early decompression of laminae and intramedullary decompression can lead to good recovery after neurologic impingement.


Assuntos
Deslocamento do Disco Intervertebral , Dor Lombar , Fusão Vertebral , Masculino , Humanos , Pessoa de Meia-Idade , Deslocamento do Disco Intervertebral/cirurgia , Deslocamento do Disco Intervertebral/complicações , Vértebras Lombares/cirurgia , Fusão Vertebral/efeitos adversos , Dor Lombar/etiologia
2.
Orthop Surg ; 15(5): 1241-1248, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36915232

RESUMO

OBJECTIVE: Although the role of anterior cervical titanium plate system in stabilizing the spine sequence and promoting bone graft fusion has been widely recognized, more and more attention has been paid to the design of the plate itself and the complications caused by it. In order to solve the problems of poor stability of internal fixation, plate displacement and screw looseness, we designed the new PRUNUS spine plate system. Hence, the present study was conducted to describe observe and evaluate the clinical efficacy of a new type of three-leaf reinforced cervical anterior screw plate system (PRUNUS nailing system) developed for anterior cervical surgery. METHODS: A retrospective analysis of 56 patients from June 2018 to October 2019 was used. Twenty-seven patients with cervical spine disease treated with new PRUNUS nail plate internal fixation were selected as the observation group, and 29 patients with cervical spine disease treated with conventional cervical anterior screw fixation were selected as the control group. Postoperative follow-up was performed. Cervical stability, internal fixation position and bone graft fusion were evaluated according to imaging data. The operative time, intraoperative blood loss, cervical Cobb angle, pain visual analogue scale (VAS), and Japanese orthopaedic association (JOA) were compared between the two groups. Spinal function scores and neurological improvement rates were used to evaluate the clinical efficacy of the new PRUNUS spine plate. RESULTS: The patients were followed up for 5-18 months, with an average of 7.33 months. The average operative time of the observation group was 98.4 ± 9.2 min, and the mean intraoperative blood loss was 65.3 ± 10.6 ml, which were significant different from the control group's 109.7 ± 9.4 minutes (P < 0.05), 72.9 ± 15.6 ml (P < 0.05). Comparison between the two groups in postoperative and final follow-up of cervical Cobb angle, JOA score and improvement rate, VAS score and preoperative comparison showed no significant differences (P > 0.05). CONCLUSION: The new PRUNUS spine plate system can be applied to the anterior cervical spine surgery, and its clinical efficacy was similar to the traditional cervical anterior plate. But PRUNUS simplified the operation process, especially suitable for the surgical treatment of anterior cervical revision and osteoporosis patients.


Assuntos
Vértebras Cervicais , Fusão Vertebral , Humanos , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Estudos Retrospectivos , Perda Sanguínea Cirúrgica , Fusão Vertebral/métodos , Resultado do Tratamento
3.
Orthop Surg ; 13(7): 2000-2007, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34523793

RESUMO

OBJECTIVE: To analyze correlations between the selection of microtitanium plates with different specifications for use in a cervical vertebral dome expansion laminoplasty. METHODS: Sixteen patients that underwent the cervical vertebral dome expansion laminoplasty with a cervical spinal stenosis angioplasty procedure for treatment of their cervical spinal cords were recruited at our hospital. From February 2017 to September 2018, medical records confirmed that all patients underwent cervical CT and MRI tests pre- and postsurgery. The anteroposterior diameter of the spinal canal, changes in the cross-sectional area of the spinal canal, and the pre- and postsurgery distance of the cervical spinal cord after applying microtitanium plates with different lengths were measured by Mimics version 17.0 software (Materialise NV, Leuven, Belgium). A statistical regression and correlation analysis of relevant specification parameters of the microtitanium plate was then studied. RESULTS: As the size of the microtitanium plate increased, we found that the cross-sectional area of cervical spinal canal and distance between the descendants of the lamina and the distance of cervical spinal cord concordantly increased, and these data changes linearly. The regression equation associated with sagittal diameter, cross-sectional area, and posterior movement distance of the cervical spinal cord was obtained. CONCLUSION: According to the correlation analysis of imaging data changes, the regression equation was obtained to guide the selection of microtitanium plates with appropriate specifications in a cervical vertebral dome expansion laminoplasty.


Assuntos
Placas Ósseas , Vértebras Cervicais/cirurgia , Desenho de Equipamento , Laminoplastia/instrumentação , Estenose Espinal/cirurgia , Idoso , Vértebras Cervicais/diagnóstico por imagem , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estenose Espinal/diagnóstico por imagem , Titânio , Tomografia Computadorizada por Raios X
4.
Orthop Surg ; 13(7): 1969-1978, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34523808

RESUMO

OBJECTIVE: To evaluate the safety and stability of 3D-printed interbody fusion cages (3D-printed cages) in anterior cervical discectomy and fusion (ACDF) by investigating the mid- and long-term follow-up outcomes. METHODS: In this prospective study, the clinical data of 30 patients with CSM admitted to the Second Hospital of Shanxi Medical University from May 2012 to May 2014 were analyzed. The cohort comprised 18 males and 12 females with an average age of 60.22 ± 3.2 years. All patients were examined by X-ray, CT and MRI before the operation. A total of 30 cases of CSM were treated by ACDF with 3D printed cage implantation. Mid- and long-term follow-ups were performed after the surgery. Clinical efficacy was evaluated by comparing the JOA score, SF-36 score, change in neurological function, cervical curvature index (CCI), vertebral intervertebral height (VIH) and fusion rate before the operation, 6 months after the operation, and at the last follow-up. RESULTS: Two of the 30 patients were lost to follow-up. The remaining patients were followed up for 48-76 (65.23 ± 3.54) months. The patients recovered satisfactorily with a significant clinical effect. The JOA score increased meanfully and the improvement rate was 89.4% at the final follow-up. The SF-36 score increased significantly from pre- to postoperatively. The height of the intervertebral space at the last follow-up was not statistically significantly different from that at 6 months after surgery (P > 0.05), showing that the height of the intervertebral space did not change much and the severity of cage subsidence (CS) decreased. The CCI improved from pre- to postoperatively. The CCI did not change much from the 6-month follow-up to the last follow-up. and the cage rate (CR) was 100% at the 6-month and last follow-ups. No severe complications, such as spinal cord injury, esophageal fistula, cerebrospinal fluid leakage, cervical hematoma or wound infection, occurred in any of the patients. CONCLUSION: The clinical and radiological results show that the application of 3D-printed cages in ACDF can significantly relieve symptoms. Moreover, 3D-printed cages can restore the curvature of the cervical spine, effectively maintain the intervertebral height for a long time, and prevent complications related to postoperative subsidence.


Assuntos
Vértebras Cervicais/cirurgia , Discotomia/métodos , Impressão Tridimensional , Doenças da Medula Espinal/cirurgia , Fusão Vertebral/instrumentação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
5.
Orthop Surg ; 13(5): 1496-1504, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34056862

RESUMO

PURPOSE: To provide imaging evidence of the feasibility and clinical efficacy of a new full lamina back shift spinal canal enlargement technique. METHODS: A retrospective analysis was conducted on 64 patients with multisegment cervical spondylotic myelopathy caused by cervical stenosis. Of these, 32 patients underwent the new full lamina back shift spinal canal enlargement technique (as observation group) and 32 patients underwent single open-door miniature titanium plate internal fixation (as control group). The computed tomography (CT) data of both groups were imported into Mimics 17.0 software to measure the median sagittal diameter and cross-sectional area of the spinal canal. Photoshop CS5 was employed to measure the drift distance of the spinal cord on MR images to perform a comparative study of the imaging parameters from the two groups. RESULTS: The T2-weighted MR images in both groups showed continuous recovery of the cerebrospinal fluid signal in the C3 -C7 range. The enlarged spinal canal cross-sectional area (mm2 ) of each segment after the new full lamina back shift spinal canal enlargement technique was 130.90 ± 20.52 (C3 ), 180.81 ± 18.86 (C4 ), 240.48 ± 35.43 (C5 ), 145.93 ± 36.94 (C6 ), and 153.16 ± 36.28 (C7 ), and the enlarged median sagittal diameter (mm) was 5.31 ± 1.13 (C3 ), 8.8 ± 1.28 (C4 ), 10.28 ± 1.68 (C5 ), 9.46 ± 1.48 (C6 ), and 9.22 ± 1.12 (C7 ). Both parameters were significantly superior to single open-door miniature titanium plate internal fixation (P < 0.05). No significant difference was detected in the drift distance of the spinal cord between the two groups (P > 0.05). CONCLUSION: The new full lamina back shift spinal canal enlargement technique achieved a thorough spinal canal decompression effect on imaging while ensuring a reasonable spinal drift distance and few surgical complications. The clinical curative effect of the new technique was precise.


Assuntos
Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Descompressão Cirúrgica/métodos , Laminoplastia/métodos , Doenças da Medula Espinal/diagnóstico por imagem , Doenças da Medula Espinal/cirurgia , Fusão Vertebral/métodos , Idoso , Diagnóstico por Imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
6.
Orthop Surg ; 12(1): 248-253, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32077255

RESUMO

OBJECTIVE: To observe and evaluate the clinical curative effect of a new type of open-powered cervical spine system developed for anterior cervical surgery. METHODS: A retrospective analysis was performed in our hospital in 2015-2017 of 329 orthopaedic patients treated with cervical anterior decompression, cage or titanium mesh graft fusion, new open-powered nail plate or traditional cervical anterior screw plate. A total of 154 (control group) and 175 (observation group) cases were fixed with conventional cervical- and new open-powered nail plates, respectively. Postoperative follow-up was performed. Cervical stability, internal fixation position, and bone graft fusion were evaluated by imaging. Operative time, intraoperative blood loss, cervical Cobb angle, pain visual analogue scale (VAS) score, and Japanese orthopaedic association (JOA) score were compared between the groups. JOA scoring (spinal cord function) and neurological function improvement rate (IR) were used to assess clinical efficacy. RESULTS: The patients were followed up for 8-36 months with an average of 19.48 months. There was no significant difference in the operation time and intraoperative blood loss between the two groups (P > 0.05). In the control group, the Cobb angles of the cervical spine were 5.13° ± 1.28°, 10.46° ± 1.07°, and 9.72° ± 1.43° before and after the operation. The observation group was followed by the Cobb angle of the cervical spine before and after the operation. They were 4.96° ± 1.39°, 11.67° ± 0.93°, and 11.13° ± 1.19°, respectively; the JOA scores before the operation, 1 week after the operation, and at the last follow-up were (8.07 ± 1.13) points and (13.57 ± 0.82) points, and (14.19 ± 0.96) points, respectively; the IR was 86.52% ± 9.33%. The preoperative, postoperative 1 week, and last follow-up JOA scores in the observation group were (8.37 ± 1.29) points, (14.11 ± 0.93) points, and (14.95 ± 0.78) points respectively. The IR was 88.74% ± 8.16% in the scores; the VAS scores were (5.54 ± 0.89) points, (1.73 ± 0.71) points, and (1.48 ± 0.52) points in the preoperative, postoperative 1 week, and last follow-up in the control group. The VAS scores were (5.81 ± 0.94) points, (1.82 ± 0.61) points, and (1.16 ± 0.49) points before, 1 week, and after the final follow-up. The JOA score and IR, VAS score and preoperative comparison between the two groups were statistically significant (P < 0.05), but there was no statistically significant difference between the two groups (P > 0.05). CONCLUSION: The new open-powered nail anterior cervical plate system can achieve the same clinical effect as the traditional anterior cervical plate fixation in anterior cervical surgery, but it can simplify the operation process, effectively make up for the shortcomings of the traditional anterior cervical plate operation, and obtain satisfactory clinical application effect, which is worthy of clinical promotion.


Assuntos
Placas Ósseas , Parafusos Ósseos , Vértebras Cervicais/cirurgia , Fixação Interna de Fraturas/instrumentação , Fusão Vertebral/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Fixação Interna de Fraturas/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Exame Neurológico , Medição da Dor , Estudos Retrospectivos , Fusão Vertebral/métodos
7.
Orthop Surg ; 12(1): 254-261, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32077263

RESUMO

OBJECTIVE: To develop a new type of open dynamic cervical spine system and study its biomechanical properties. METHODS: Ten fresh goat spine specimens were used in this study. Using high precision digital display grating displacement sensor system, a new type of open dynamic nail plate fixation was compared with Atlantis nail plate fixation in terms of the stability of cervical vertebrae, pull-out strength, and fatigue strength. RESULTS: Biomechanical tests showed: (i) the new type of open dynamic cervical anterior nail plate system has similar three-dimensional stability as the Atlantis nail plate system, and can ensure the stability of anterior cervical fixation surgery; (ii) the fatigue life and fatigue strength of this new open dynamic anterior cervical nail plate and Atlantis nail plate are similar, and can adequately maintain the cervical stability after anterior bone graft fusion, to ensure long-term safety and efficacy of the nail plate system in the body; and (iii) the overall fixed performance of the new type of open dynamic cervical nail system is satisfactory. CONCLUSION: The new type of open dynamic anterior cervical nail plate system has satisfactory biomechanical characteristics and cervical spine stability effect.


Assuntos
Placas Ósseas , Parafusos Ósseos , Vértebras Cervicais/cirurgia , Teste de Materiais , Fusão Vertebral/instrumentação , Animais , Fenômenos Biomecânicos , Desenho de Equipamento , Cabras , Estresse Mecânico
8.
Orthop Surg ; 11(6): 1180-1186, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31823498

RESUMO

OBJECTIVE: To investigate the efficacy and safety of ultrasonic bone curette in treating thoracic spinal stenosis. METHODS: A total of 30 patients of thoracic spinal stenosis who underwent posterior thoracic decompression in the hospital from December 2015 to 2017 were enrolled. Of these, 18 patients (group A) underwent posterior thoracic decompression using ultrasonic bone curette; and 12 patients underwent the treatment using a high-speed drill (group B). The time of laminectomy, amount of intraoperative blood loss, presence or absence of cerebrospinal fluid leakage, and nerve root injury were recorded. All patients underwent X-ray, computed tomography with three-dimensional reconstruction, and magnetic resonance imaging before and after surgery. The Frankel classification and the Japanese Orthopaedic Association (JOA) scores were used to assess the neurological function and neurological recovery in patients. The measured data were statistically processed and analyzed using SPSS21.0 software, and the measurement data were expressed as mean ± SD. RESULTS: In groups A and B, the average time for single-segment laminectomy was 3.3 ± 1.2 min and 6.0 ± 1.8 min and the mean bleeding volume was 105.5 ± 43.3 mL and 177.4 ± 54.7 mL, respectively, with a statistically significant difference between the groups. The difference in JOA scores before and after surgery in groups A and B was statistically significant. No significant difference was found between the groups, in group A, the improvement rate of nerve function at the last follow-up was 71% and in group B, the improvement rate at the last follow-up was 70%. In group A, at last follow-up, two patients had Frankel grade B injury, one had grade C injury, seven had grade D injury, and eight had grade E injury. In group B, at last follow-up, one patient had Frankel grade B injury, one had grade C injury, five had grade D injury, and five had grade E injury. The Frankel classification of both groups A and B significantly improved. Four patients experienced cerebrospinal fluid leakage in group A and five in group B, with no significant difference between the groups. There was no nerve root injury in both groups, and no complications, such as pulmonary infection and urinary tract infection, occurred after operation. CONCLUSIONS: With the use of ultrasonic bone curette in posterior thoracic decompression, the decompression surgery could be completed relatively safely and quickly. It effectively reduced the amount of intraoperative blood loss.


Assuntos
Laminectomia/métodos , Estenose Espinal/cirurgia , Vértebras Torácicas/cirurgia , Procedimentos Cirúrgicos Ultrassônicos/métodos , Idoso , Perda Sanguínea Cirúrgica , Avaliação da Deficiência , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA