Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
J Periodontol ; 2024 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-38881046

RESUMO

BACKGROUND: Implant surface decontamination is a critical step in peri-implantitis treatment. The aim of this study was to assess the effect chemotherapeutic agents have on reosseointegration after treatment on ligature-inducted peri-implantitis. METHODS: Six male canines had 36 implants placed and ligatures were placed around them for 28 weeks to establish peri-implantitis. The peri-implant defects were randomly treated by 1 of 3 methods: 0.12% chlorhexidine (CHX test group), 1.5% sodium hypochlorite (NaOCl test group), or saline (Control group). Sites treated with NaOCl and CHX were grafted with autogenous bone, and all sites then either received a collagen membrane or not. Histology sections were obtained at 6 months postsurgery to assess percentage of reosseointegration. RESULTS: Thirty-five implants were analyzed (CHX: 13; NaOCl: 14; Control:8). NaOCl-treated sites demonstrated reosseointegration with direct bone-to-implant-contact on the previously contaminated surfaces (42% mean reosseointegration), which was significantly higher than Controls (p < 0.05). Correspondingly, clinical improvement was noted with a significant reduction in probing depth from 5.50 ± 1.24 mm at baseline to 4.46 ± 1.70 mm at 6-months postsurgery (p = 0.006). CHX-treated sites demonstrated a nonsignificant reosseointegration of 26% (p > 0.05); however, in the majority of cases, the new bone growth was at a distance from the implant surface without contact. Probing depths did not improve in the CHX group. The use of membrane did not influence reosseointegration or probing depths (all p > 0.05). CONCLUSION: Titanium implants with peri-implantitis have the capacity to reosseointegrate following regenerative surgery. However, treatment response is contingent upon the chemotherapeutic agent selection. Additional chemical treatment with 1.5% NaOCl lead to the most favorable results in terms of changes in defect depth and percentage of reosseointegration as compared to CHX, which may hinder reosseointegration.

2.
J Clin Periodontol ; 51(2): 196-208, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38088448

RESUMO

AIM: To reveal the cellular composition and molecular environment of the periodontal and peri-implant inflammatory infiltrates through a single-cell sequencing technique, which may explain the pathological difference between these two diseases. A special focus was placed on the phenotypes and potential roles of neutrophils and fibroblasts in peri-implant/periodontal tissue immunity. MATERIALS AND METHODS: High-throughput single-cell transcriptomic profiling of peri-implant tissues from patients with peri-implantitis as well as periodontal tissues from patients with periodontitis and healthy donors was performed. Immunofluorescence analysis was carried out to further validate the identified cell subtypes and their involvement in peri-implantitis and periodontitis. RESULTS: Based on our single-cell resolution analysis, a quantified proportional increase of neutrophil (Neu) subtypes was shown in peri-implantitis. Among these, a predominance of Neutro_CXCR2 was revealed. We also found the involvement of inflammation-promoting fibroblasts as well as a predominance of CXCL8+ fibroblast-CXCR2+ neutrophil interaction in peri-implantitis. CONCLUSIONS: Our study indicated that the predominance of CXCL8+ fibroblast-CXCR2+ neutrophil interaction might underline the enhanced host response in peri-implantitis compared with periodontitis. This information offers a molecular basis by which fibroblast and neutrophil subtypes might be diagnostically and therapeutically targeted in peri-implantitis.


Assuntos
Implantes Dentários , Peri-Implantite , Periodontite , Humanos , Neutrófilos , Inflamação , Periodontite/patologia , Fibroblastos
3.
Clin Oral Implants Res ; 34(1): 1-12, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36245267

RESUMO

OBJECTIVES: Simplification and standardization of interventions are critical challenges to improving performance in implant dentistry. This study aimed to systematically identify and schematically present the evidence base of the implant dentistry surgical interventions for the anterior maxilla as a basis for further development and standardization. METHODS: Electronic searches were conducted in PubMed, Embase and Cochrane CENTRAL. Primary clinical studies reporting surgical interventions in the anterior maxilla, with a sample size of at least ten patients, were included. Bibliometric information and study details were extracted. Descriptive analysis and a mind map approach were used to describe the documentation of different surgical interventions. RESULTS: Two hundred and seventy-two studies reporting on 9001 patients were included. Within the past two decades, the number of literatures on implant placement in the anterior maxilla has increased dramatically (7 studies before 2005, 151 studies after 2016). Overall, the evidence map identified six primary operations and 33 variations. For hopeless tooth extraction, immediate implant placement was the most frequently reported (141 studies, 4670 patients); flapless implant placement with hard tissue augmentation and immediate provisionalization was the most commonly reported variation (33 studies, 987 patients). Type 3/4 implant placement (62 studies, 1902 patients) and implant site augmentation (33 studies, 788 patients) were frequently reported for missing teeth. Geographical differences were observed, with type 2 placement studies almost exclusively from Europe. CONCLUSIONS: Research on immediate implant placement was the most reported surgical intervention in the anterior maxilla. Hard tissue augmentation was frequently reported simultaneously with or before implant placement. Immediate provisionalization was mainly used for type 1 implant placement. The finding that six primary operations with 33 variations have been reported indicates the need for additional research to simplify and consolidate the surgical approach.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Carga Imediata em Implante Dentário , Humanos , Implantação Dentária Endóssea , Maxila/cirurgia , Estética Dentária
4.
Clin Implant Dent Relat Res ; 25(1): 3-10, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36373737

RESUMO

OBJECTIVES: To evaluate the clinical, radiographic, and esthetic outcomes of immediate implant placement with buccal bone dehiscence in the anterior maxilla. METHODS: In this case series, implants were inserted immediately after tooth extraction in sockets with buccal bone dehiscence. Guided bone regeneration (GBR) with a papilla preservation flap and simultaneous connective tissue grafting (CTG) was used. The following outcome variables were measured: mid-facial mucosal recession, probing depth, bleeding on probing, Pink Esthetic Score (PES), marginal bone loss, and thickness of buccal bone plate (TBP). RESULTS: 12 patients were recruited. Stable mid-facial mucosal level (-0.03 ± 0.17 mm) and excellent soft-tissue esthetic outcomes (PES, 9.17 ± 0.72) were achieved at 1 year. The TBP at platform level was 2.01 ± 0.31 mm at 1-year follow up with a resorption rate of 28.90% ± 15.14%. CONCLUSIONS: Immediate implant placement using GBR performed with a papilla preservation approach and simultaneous CTG is a feasible treatment procedure in compromised extraction sockets in the anterior region. Favorable esthetic outcomes and buccal bone thickness were obtained. Further studies were needed to evaluate the long-term tissue alteration.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Carga Imediata em Implante Dentário , Humanos , Resultado do Tratamento , Maxila/diagnóstico por imagem , Maxila/cirurgia , Estética Dentária
5.
J Prosthet Dent ; 130(2): 212-218, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34776266

RESUMO

STATEMENT OF PROBLEM: Clinical studies on the accuracy of the photogrammetric imaging technique for complete arch implant-supported fixed dental prostheses are lacking. PURPOSE: The purpose of this clinical study was to evaluate the accuracy (trueness) of photogrammetric imaging for complete arch implant-supported prostheses by comparing photogrammetric imaging with verified conventional splinted impressions. MATERIAL AND METHODS: Completely edentulous arches with at least 4 implants were included. Both photogrammetric imaging and conventional splinted impressions were performed in each jaw. The conventional casts were verified and scanned by using a laboratory scanner as the control. The distances and angulations between different implants (interimplant distances and interimplant angulations) were measured in all photogrammetric and conventional standard tessellation language (STL) files by using a reverse-engineering software program. The distance deviations between the photogrammetric and conventional impressions of the same participant were calculated as the primary outcome, and the angular deviations were obtained as the secondary outcome with descriptive analyses. The comparison between distance deviations and the clinically acceptable level of deviations (150 µm) was conducted by using the 1-sample t test. The effect of interimplant distances, interimplant angulations, and jaw (maxilla or mandible) on deviations was analyzed by using the Spearman correlation analysis, Kruskal-Wallis test, or Student t test, depending on the type of data (α=0.05 for all tests). RESULTS: Fourteen edentulous jaws were included. The overall distance deviation of photogrammetric imaging was 70 ±57 µm, significantly lower than the clinically acceptable level of misfit (150 µm; P<.001). The overall angular deviation was 0.432 ±0.348 degrees. The distance deviations were correlated with interimplant distances with a correlation coefficient (r) of 0.371 (P=.002). Interimplant angulation was not correlated with distance or angular deviations (P=.914, P=.914). Jaw was not correlated with distance or angular deviations either (P=.190, P=.209). CONCLUSIONS: The accuracy (trueness) of photogrammetric imaging of complete arch implant-supported prostheses was within a clinically acceptable range of errors. Distance deviations increased with greater interimplant distances. Interimplant angulations and jaw (maxilla or mandible) had no significant effect on the accuracy of photogrammetric imaging.


Assuntos
Implantes Dentários , Arcada Edêntula , Humanos , Técnica de Moldagem Odontológica , Modelos Dentários , Arcada Edêntula/diagnóstico por imagem , Fotogrametria , Desenho Assistido por Computador , Imageamento Tridimensional/métodos , Arco Dental/diagnóstico por imagem , Arco Dental/cirurgia
6.
Clin Oral Implants Res ; 33(12): 1245-1253, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36203410

RESUMO

BACKGROUND: The aim of this study was to compare the 3-year clinical outcomes of narrow-diameter implants (NDI) with standard-diameter implants (SDI) in conjunction with lateral bone augmentation in atrophic posterior jaws. MATERIALS AND METHODS: Fifty patients were included and randomly assigned into two groups: Patients in Group 1 received NDI (Ø3.5 mm); patients in Group 2 received SDI (Ø4.3 mm) with simultaneous lateral bone augmentation. Implant survival rates, complications, crestal bone loss, peri-implant conditions, treatment cost, and patient satisfaction were compared. RESULTS: Three patients dropped out the follow-up. No implant loss was observed. The difference in technical complication rates between the two groups was 3.8% (95% CI: -13.7% to 21.3%). No significant differences in crestal bone loss were found between two groups at 3-year follow-up (0.55 ± 0.76 vs 0.41 ± 0.41 mm, p = .429). A total of 20.8% (5/24) of NDI were diagnosed with mucositis and 8.3% (2/24) with peri-implantitis. A total of 17.4% (4/23) of SDI showed mucositis and (1/23) 4.3% showed peri-implantitis. The total cumulative cost of treatment per patient in Group 1 (2849.6 USD, 95% CI: 2726.8-2972.4) was significantly lower than that in Group 2 (3581.4 USD, 95% CI, 3460.9-3701.9) over the 3-year follow-up (p < .01). The patient satisfaction rating of operation was significantly higher in Group 1 (85.42 ± 7.41 vs 80.48 ± 7.95, p = .033). DISCUSSION: NDI yielded favorable implant survival, acceptable technical and biological complications, and high patient satisfaction supporting single crowns in the atrophic posterior region after 3-year follow-up. NDI might be a reasonable alternative in horizontally deficient posterior jaws. TRIAL REGISTRATION: Clinicaltrials.gov identifier: ChiCTR1800020426.

7.
Front Nutr ; 9: 930023, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35832045

RESUMO

Background: Loss of masticatory function consequent to tooth loss has been associated with changes in food choices and insufficient nutritional intake. To date, interventions based on dental prostheses alone did not significantly improve nutrient intake. Pilot studies have shown positive impacts of interventions combining implant-supported fixed dental prosthesis with brief dietary advice. The relative contribution and the potential synergy of the components of such interventions need to be determined as it has major public health implications for the community-dwelling aging population that continues to disproportionately suffer from tooth loss and its consequences. Objective: To assess the effect of rehabilitation of masticatory function with fixed implant supported dentures and nutrition education in older subjects with terminal dentition (stage IV periodontitis) or full edentulism. Methods: A 2 × 2 factorial randomized controlled trial with 16-month follow-up of eligible adults (≥60 years) with loss of masticatory function consequent to full arch edentulism or terminal dentition (n = 120) will be conducted to test whether the rehabilitation of masticatory function with fixed implant supported dentures, nutrition education and/or their combination improves intake of fresh fruits and vegetables for aging subjects. The study has been designed to detect changes in fresh fruits and fresh vegetables intake at 4 months using the 24-h dietary recall method. Changes in protein as percentage of total energy, nutritional biomarkers, plasma metabolomics, oral and gut microbiome, quality of life and masticatory function will also be assessed. Discussion: We hypothesize that receiving rehabilitation of masticatory function with fixed implant dentures together with nutrition education is the most effective intervention for improving nutrient intake in aging community-dwelling subjects with extensive tooth loss. The results of this study will assist in designing better treatment regimens, guide medical care for individual subjects, and inform public health and policy. Clinical Trials Registration: NCT05334407.

8.
Clin Oral Implants Res ; 33(7): 713-722, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35509121

RESUMO

AIM: To evaluate the long-term survival of short implants and to investigate the association of the Implant Disease Risk Assessment (IDRA) with the occurrence of biological complications. MATERIAL AND METHODS: This study was designed as a cohort study with a median follow-up of 10.0 years. Patients who had received 6-mm implants were reviewed and assigned into low-, moderate-, and high-risk groups (Group L, M, and H) based on the IDRA tool. The implant survival, biological complications, soft tissue condition, hardware complications, and marginal bone loss (MBL) were evaluated. Kaplan-Meier curves and Cox regression were performed for survival analysis. RESULTS: A hundred and ten patients were included. The overall cumulative survival rate was 90.9% (L:100.0%, M: 93.3%, and H: 80.6%). A higher risk profile was significantly associated with a decreased implant survival (hazard ratio: 4.11, 95% CI: 1.17-14.36, p < .05). Higher risk profile (hazard ratio: 2.63, 95% CI: 1.32-5.25, p < .05) was a potential risk factor for biological complications. At follow-up, significant differences in bleeding index, modified plaque index, and peri-implant probing depth were found among groups (p < .01). No significant difference was found in MBL. CONCLUSION: Acceptable long-term clinical outcomes could be achieved after 10 years for short implants. Despite a statistically nonsignificant difference in MBL, patients with a high-risk profile of IDRA seem to be at greater risk of implant loss and biological complications.


Assuntos
Perda do Osso Alveolar , Implantes Dentários , Perda do Osso Alveolar/etiologia , Estudos de Coortes , Implantes Dentários/efeitos adversos , Índice de Placa Dentária , Seguimentos , Humanos , Medição de Risco , Resultado do Tratamento
9.
J Clin Periodontol ; 49(2): 144-152, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34747036

RESUMO

AIM: Analysis of distribution of p-values of continuous differences between test and controls after randomization provides evidence of unintentional error, non-random sampling, or data fabrication in randomized controlled trials (RCTs). We assessed evidence of highly unusual distributions of baseline characteristics of subjects enrolled in clinical trials in implant dentistry. MATERIALS AND METHODS: RCTs published between 2005 and 2020 were systematically searched in Pubmed, Embase, and Cochrane databases. Baseline patient data were extracted from full text articles by two independent assessors. The hypothesis of non-random sampling was tested by comparing the expected and the observed distribution of the p-values of differences between test and controls after randomization. RESULTS: One-thousand five-hundred and thirty-eight unique RCTs were identified, of which 409 (26.6%) did not report baseline characteristics of the population, and 671 (43.6%) reported data in forms other than mean and standard deviation and could not be used to assess their random sampling. Four-hundred and fifty-eight trials with 1449 baseline variables in the form of mean and standard deviation were assessed. The study observed an over-representation of very small p-values [<.001, 1.38%, 95% confidence interval (CI) 0.85-2.12 compared to the expected 0.10%, 95% CI 0.00-0.26]. No evidence of over-representation of larger p-values was observed. Unusual distributions were present in 2.38% of RCTs and more frequent in non-registered trials, in studies supported by non-industry funding, and in multi-centre RCTs. CONCLUSIONS: The inability to assess random sampling due to insufficient reporting in 26.6% of trials requires attention. In trials reporting suitable baseline data, unusual distributions were uncommon, and no evidence of data fabrication was detected, but there was evidence of non-random sampling. Continued efforts are necessary to ensure high integrity and trust in the evidence base of the field.


Assuntos
Ensaios Clínicos como Assunto , Odontologia , Projetos de Pesquisa , Humanos , Fatores de Risco
10.
Shanghai Kou Qiang Yi Xue ; 31(4): 423-428, 2022 Aug.
Artigo em Chinês | MEDLINE | ID: mdl-36710559

RESUMO

PURPOSE: To compare the clinical efficacy of angulated screw channel abutments and prefabricated titanium abutments on the restoration of single implant crowns in esthetics region. METHODS: The study was a prospective, single center, randomized controlled trial. Patients with the need of restoration of single tooth in esthetics region were included from June 2018 to June 2019. Forty patients were randomly assigned into two groups: screw-retained crowns with angulated screw channel abutments(angulated group, AG) and cemented crowns with prefabricated Ti abutments (cemented group, CG). Clinical and radiological evaluations were performed on the day of final crowns delivery and 6 months later. Implant survival rate, marginal bone loss (MBL), mechanical complications, peri-implant conditions (Probing depth, PD; bleeding on probing, BOP%), pink esthetics score/white esthetics score(PES/WES) and patients' satisfaction were assessed. The data was analyzed with SPSS 19.0 software package. RESULTS: Thirty-six patients (AG: 19, CG: 17) attended the 6-month clinical trial. Implant survival rates were both 100% in two groups. The MBL was (0.21±0.18) mm for AG and (0.38±0.40) mm for CG (P>0.05). The BOP% was significantly higher in AG than that in CG (P=0.04). No significant difference of mechanical complications, PD, PES/WES and patients' satisfaction was found between the two groups(P>0.05). CONCLUSIONS: Based on the present results, both treatment options show acceptable clinical outcomes in the short term. Angulated screw-retained crowns may benefit the peri-implant soft tissue; however, studies with long-term follow-up are needed to verify the results.


Assuntos
Implantes Dentários para Um Único Dente , Humanos , Seguimentos , Estudos Prospectivos , Estética Dentária , Coroas , Resultado do Tratamento , Parafusos Ósseos , Zircônio , Dente Suporte
11.
Front Immunol ; 12: 711337, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34566966

RESUMO

Periodontitis is a highly prevalent chronic inflammatory disease leading to periodontal tissue breakdown and subsequent tooth loss, in which excessive host immune response accounts for most of the tissue damage and disease progression. Despite of the imperative need to develop host modulation therapy, the inflammatory responses and cell population dynamics which are finely tuned by the pathological microenvironment in periodontitis remained unclear. To investigate the local microenvironment of the inflammatory response in periodontitis, 10 periodontitis patients and 10 healthy volunteers were involved in this study. Single-cell transcriptomic profilings of gingival tissues from two patients and two healthy donors were performed. Histology, immunohistochemistry, and flow cytometry analysis were performed to further validate the identified cell subtypes and their involvement in periodontitis. Based on our single-cell resolution analysis, we identified HLA-DR-expressing endothelial cells and CXCL13+ fibroblasts which are highly associated with immune regulation. We also revealed the involvement of the proinflammatory NLRP3+ macrophages in periodontitis. We further showed the increased cell-cell communication between macrophage and T/B cells in the inflammatory periodontal tissues. Our data generated an intriguing catalog of cell types and interaction networks in the human gingiva and identified new inflammation-promoting cell subtypes involved in chronic periodontitis, which will be helpful in advancing host modulation therapy.


Assuntos
Periodontite Crônica/imunologia , Inflamação/etiologia , Análise de Sequência de RNA/métodos , Análise de Célula Única/métodos , Comunicação Celular , Células Endoteliais/imunologia , Fibroblastos/imunologia , Gengiva/imunologia , Humanos
12.
Clin Implant Dent Relat Res ; 23(5): 692-702, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34390601

RESUMO

BACKGROUND: Screw-retained implant crowns are considered more biologically compatible than cemented crowns due to the absence of excess cement. However, traditional screw-retained implant crowns are not viable when the access hole of the screw channel would need to be located in an esthetic area, which would compromise the esthetic outcome of the treatment. PURPOSE: To evaluate the clinical, radiographic, and immunological outcomes of angulated screw-retained and cemented single-implant crowns in the esthetic region. MATERIALS AND METHODS: The study was a single-center, open-label, randomized controlled clinical trial. Eligible patients were randomly placed in two groups: angulated screw-retained group (AG) and cemented group (CG). Implant survival rate, bleeding on probing rate (BOP%), probing depth (PD), modified plaque index (mPI), marginal bone loss (MBL), concentrations of pro-inflammatory cytokines (TNF-α, IL-6) in peri-implant crevicular fluid (PICF), mechanical complications, and pink esthetic score/white esthetic score (PES/WES) were evaluated. RESULTS: Fifty-six patients (AG: 29, CG: 27) attended the 1-year examination. The drop-out rate was 6.67%. No implant failure was found in both groups during the observation period. BOP% was significantly lower in the AG than that in the CG (mean, 21.84% ± 19.97% vs. 37.04% ± 26.28%, p = 0.018). The concentration of TNF-α in PICF was significantly higher in the AG than that in the CG (median, 13.54 vs. 4.62, p = 0.019). No significant difference of PD, mPI, MBL, IL-6, or mechanical complication rates was found between the two groups. Mean scores for PES/WES were 21.71 and 21.64 in the AG and CG, respectively. CONCLUSION: Based on the present results, both treatment options showed acceptable clinical outcomes in the short term. Angulated screw-retained crowns might benefit the peri-implant soft tissue. However, studies with long-term follow-up are needed to confirm whether the higher concentration of TNF-α will compromise the long-term outcomes of treatment.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Parafusos Ósseos , Coroas , Cimentos Dentários , Prótese Dentária Fixada por Implante , Estética Dentária , Humanos
13.
Int J Oral Maxillofac Implants ; 36(3): 442-449, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34115056

RESUMO

PURPOSE: To investigate the effect of implant angulation, non-free-end partial edentulism, and number of scan bodies on the accuracy of digital impressions of multiple implants in partially edentulous arches. MATERIALS AND METHODS: Four reference models of partially edentulous mandibles with implants (RM1, RM2, RM3, and RM4) representing different intraoral situations were each scanned 10 times by an intraoral scanner. Reference scans were obtained by a laboratory scanner. Test scans were compared with reference scans to obtain the distance deviations (Δd) and angular deviations (Δθ) between scan bodies for trueness assessment. Differences among the repeated test scans of each model were measured and recorded as Δdp and Δθp for precision assessment. The Student t test (α = .05) was used to compare Δd, Δθ, Δdp, and Δθp of different reference models, including RM2 vs RM1 (effect of non-free-end partial edentulism), RM3 vs RM1 (effect of implant angulation), and RM4 vs RM1 (effect of number of scan bodies). RESULTS: The implant with 17-degree angulation in RM3 showed significantly lower Δd, Δθ, and Δθp compared with the parallel implant in RM1 (Δd: P = .0382, Δθ: P = .0267, Δθp: P = .0417). The RM2 of non-free-end partial edentulism had lower distance and angular deviations than RM1, but without a significant difference. The number of scan bodies had no significant effect on the Δd, Δθ, Δdp, and Δθp of RM4 and RM1. CONCLUSION: Angulated implants showed better accuracy of digital impressions in partially edentulous arches compared with parallel implants. Non-free-end partial edentulism was attributed to improved accuracy, while the number of scan bodies showed no effect.


Assuntos
Implantes Dentários , Boca Edêntula , Desenho Assistido por Computador , Técnica de Moldagem Odontológica , Humanos , Imageamento Tridimensional , Modelos Dentários
14.
Cell Death Dis ; 12(7): 628, 2021 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-34145224

RESUMO

With an increasing aging society, China is the world's fastest growing markets for oral implants. Compared with traditional oral implants, immediate implants cause marginal bone resorption and increase the failure rate of osseointegration, but the mechanism is still unknown. Therefore, it is important to further study mechanisms of tension stimulus on osteoblasts and osteoclasts at the early stage of osseointegration to promote rapid osseointegration around oral implants. The results showed that exosomes containing circ_0008542 from MC3T3-E1 cells with prolonged tensile stimulation promoted osteoclast differentiation and bone resorption. Circ_0008542 upregulated Tnfrsf11a (RANK) gene expression by acting as a miR-185-5p sponge. Meanwhile, the circ_0008542 1916-1992 bp segment exhibited increased m6A methylation levels. Inhibiting the RNA methyltransferase METTL3 or overexpressing the RNA demethylase ALKBH5 reversed osteoclast differentiation and bone resorption induced by circ_0008542. Injection of circ_0008542 + ALKBH5 into the tail vein of mice reversed the same effects in vivo. Site-directed mutagenesis study demonstrated that 1956 bp on circ_0008542 is the m6A functional site with the abovementioned biological functions. In conclusion, the RNA methylase METTL3 acts on the m6A functional site of 1956 bp in circ_0008542, promoting competitive binding of miRNA-185-5p by circ_0008542, and leading to an increase in the target gene RANK and the initiation of osteoclast bone absorption. In contrast, the RNA demethylase ALKBH5 inhibits the binding of circ_0008542 with miRNA-185-5p to correct the bone resorption process. The potential value of this study provides methods to enhance the resistance of immediate implants through use of exosomes releasing ALKBH5.


Assuntos
Reabsorção Óssea/metabolismo , Comunicação Celular , Diferenciação Celular , Exossomos/metabolismo , Osteoblastos/metabolismo , Osteoclastos/metabolismo , Osteogênese , RNA Circular/metabolismo , Células 3T3 , Homólogo AlkB 5 da RNA Desmetilase/genética , Homólogo AlkB 5 da RNA Desmetilase/metabolismo , Animais , Reabsorção Óssea/genética , Reabsorção Óssea/patologia , Microambiente Celular , Exossomos/transplante , Feminino , Mecanotransdução Celular , Metilação , Metiltransferases/genética , Metiltransferases/metabolismo , Camundongos , Camundongos Endogâmicos BALB C , MicroRNAs/genética , MicroRNAs/metabolismo , Osseointegração , Osteoblastos/transplante , Osteoclastos/patologia , Células RAW 264.7 , RNA Circular/genética , Ratos , Receptor Ativador de Fator Nuclear kappa-B/genética , Receptor Ativador de Fator Nuclear kappa-B/metabolismo , Estresse Mecânico
15.
Int J Oral Implantol (Berl) ; 14(2): 157-179, 2021 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-34006079

RESUMO

PURPOSE: To evaluate the accuracy of full-arch digital implant impressions taken using intraoral scanners and analyse the related variables. MATERIALS AND METHODS: An electronic search of studies on the accuracy of digital implant impressions in fully edentulous arches from 1 January 2012 to 29 February 2020 was conducted in PubMed, EMBASE and the Cochrane Library. Only peer-reviewed experimental or clinical studies written in English were included. Studies assessing the accuracy of restorations, case reports, clinical reports, technical reports and reviews were excluded. The literature screening, article reading and assessment of risk of bias were carried out by two reviewers. The data on the study characteristics, accuracy outcomes and investigated variables were extracted. RESULTS: After removal of duplicates, a total of 166 studies were identified, of which 42 were initially selected for full-text reading and 30 were included in the final analysis (29 in vitro studies and one in vivo study). The trueness of digital implant impressions ranged from 7.6 to 731.7 µm, and the precision ranged from 15.2 to 204.2 µm. Angular deviations were between 0.13 and 10.01 degrees. Considering 100 µm and 0.4 degrees as clinically acceptable levels of deviation, 18 studies reported linear/distance/3D deviations larger than 100 µm and only two studies reported angular deviations below 0.4 degrees. The effect of interimplant distance/length of the arch scanned/scanning sequence/scanning range/implant position (nine studies), implant angulation (ten studies), implant depth (five studies), implant connection (two studies), operator experience (six studies), scan body type (three studies), intraoral scanner type (six studies), scanning strategy (two studies) and modification technique (three studies) was investigated. CONCLUSIONS: Based on the results of the included studies, full-arch digital implant impressions taken using intraoral scanners are not sufficiently accurate for clinical application. Accuracy varies greatly with interimplant distance, scan body type, intraoral scanner type and operator experience, whereas implant angulation, implant connections and implant depth have no effect. The effects of scanning strategy and modification technique need further investigation.


Assuntos
Implantes Dentários , Boca Edêntula , Desenho Assistido por Computador , Técnica de Moldagem Odontológica , Humanos , Modelos Dentários
16.
Int J Implant Dent ; 7(1): 36, 2021 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-33937945

RESUMO

OBJECTIVES: This study aims to evaluate the ability of tantalum-coated titanium to improve human gingival fibroblasts' adhesion, viability, proliferation, migration performance, and the potential molecular mechanisms. MATERIALS AND METHODS: Titanium plates were divided into two groups: (1) no coating (Ti, control), (2) Tantalum-coated titanium (Ta-coated Ti). All samples were characterized by scanning electronic microscopy, surface roughness, and hydrophilicity. Fibroblasts' performance were analyzed by attached cell number at 1 h, 4 h, and 24 h, morphology at 1 h and 4 h, viability at 1 day, 3 days, 5 days, and 7 days, recovery after wounding at 6 h, 12 h, and 24 h. RT-PCR, western blot were applied to detect attachment-related genes' expression and protein synthesis at 4 h and 24 h. Student's t test was used for statistical analysis. RESULTS: Tantalum-coated titanium demonstrates a layer of homogeneously distributed nano-grains with mean diameter of 25.98 (± 14.75) nm. It was found that after tantalum deposition, human gingival fibroblasts (HGFs) adhesion, viability, proliferation, and migration were promoted in comparison to the control group. An upregulated level of Integrin ß1 and FAK signaling was also detected, which might be the underlying mechanism. CONCLUSION: In the present study, adhesion, viability, proliferation, migration of human gingival fibroblasts are promoted on tantalum-coated titanium, upregulated integrin ß1 and FAK might contribute to its superior performance, indicating tantalum coating can be applied in transmucosal part of dental implant. CLINICAL SIGNIFICANCE: Tantalum deposition on titanium surfaces can promote human gingival fibroblast adhesion, accordingly forming a well-organized soft tissue sealing and may contribute to a successful osseointegration.


Assuntos
Tantálio , Titânio , Adesão Celular , Fibroblastos , Humanos , Propriedades de Superfície
17.
J Clin Periodontol ; 48(5): 695-704, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33570787

RESUMO

AIM: To compare the 3-year clinical, radiographic and economic outcomes of short-6-mm implants and longer implants combined with osteotome sinus floor elevation (OSFE) in the posterior maxilla. MATERIAL AND METHODS: This study enrolled 225 patients (225 implants with diameter of 4.1 mm and 4.8 mm) with a posterior maxillary residual bone height (RBH) of 6-8 mm. Patients were randomly divided into three groups: Group 1 (6 mm implants alone), Group 2 (8 mm implants + OSFE) and Group 3 (10 mm implants + OSFE). The following outcomes were recorded at 1 and 3-year examinations: implant survival, probing pocket depth (PPD), bleeding on probing (BOP), modified plaque index (mPI), marginal bone loss (MBL), biological and technical complications, complication-free survival and treatment costs. RESULTS: At the 3-year follow-up, 199 patients (Group 1: 67; Group 2: 62; Group 3: 70) were re-examined. Implant survival rates were 91.80%, 97.08% and 100.00% in groups 1, 2 and 3. Implant survival rate in Group 1 was significantly lower than that in Group 3 (p = 0.029). A multivariate Cox model showed that the short-6-mm implants with wide diameter had a protective effect on implant survival (hazard ratio: 0.59, p = 0.001). No significant differences in BOP%, PPD, mPI, MBL and complication-free survival rate were found among the three groups. The average costs of retreatment were 8.31%, 1.96% and 0.56% of the total costs in groups 1, 2 and 3. The cost to avoid a 1% increase in implant loss associated with 6-mm implants over a 3-year period was 369 CNY (56 USD) using a 10-mm implant with OSFE and 484 CNY (74 USD) using an 8-mm implant with OSFE. CONCLUSION: In the moderately atrophic posterior maxillae, the three treatments showed acceptable clinical, radiographic and economic outcomes with up to 3-year follow-up. 10-mm implants combined with OSFE showed more favourable implant survival and fewer maintenance costs in comparison with short-6-mm implants, which were less expensive.


Assuntos
Perda do Osso Alveolar , Implantes Dentários , Levantamento do Assoalho do Seio Maxilar , Perda do Osso Alveolar/diagnóstico por imagem , Perda do Osso Alveolar/cirurgia , Análise Custo-Benefício , Implantação Dentária Endóssea , Planejamento de Prótese Dentária , Humanos , Maxila/diagnóstico por imagem , Maxila/cirurgia , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
18.
J Clin Periodontol ; 47(12): 1528-1535, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32929768

RESUMO

OBJECTIVE: The aim of the present study was to report 10-year results of osteotome sinus floor elevation (OSFE) without grafting severely atrophic maxilla (residual bone height ≤4 mm). MATERIALS AND METHODS: Patients undergoing OSFE without grafting and implant placement were included for 10-year examinations. Implant survival, complication-free survival, modified bleeding index (mBI), modified plaque index (mPI), pocket probing depth (PPD), peri-implant marginal bone loss (MBL), endo-sinus bone gain (ESBG) and mean cost of recurrence were evaluated. RESULTS: Overall, 23 patients with 35 implants attended 10-year examination. Cemented implant crowns or implant-supported fixed dental prostheses were delivered to the patients. Kaplan-Meier implant survival was 89.2% at implant level and 84.1% at patient level. Complication-free survival was 26.0% at patient level and 37.0% at implant level. The average complication-free survival time was 74.6 months (95% CI: 63.2-86.0 months) at implant level and 69.1 months (95% CI: 54.8-83.4 months) at patient level. The mBI, mPI, PPD, MBL and ESBG at 10-year follow-up were 0.91 ± 0.58, 0.48 ± 0.51, 2.94 ± 0.79 mm, 1.63 ± 0.83 mm and 2.72 ± 0.51 mm, respectively. The cost of managing recurrence was 43.6% of the initial cost of treatment. CONCLUSION: The results of the present study indicate that OSFE without grafting is a reliable treatment option in severely atrophic maxilla. Acceptable survival rate, stable MBL and ESBG could be achieved within 10 years. Low complication-free survival and high costs of recurrence management need to be considered.


Assuntos
Perda do Osso Alveolar , Implantes Dentários , Levantamento do Assoalho do Seio Maxilar , Perda do Osso Alveolar/diagnóstico por imagem , Perda do Osso Alveolar/cirurgia , Implantação Dentária Endóssea , Humanos , Maxila/diagnóstico por imagem , Maxila/cirurgia , Seio Maxilar/cirurgia , Estudos Prospectivos , Resultado do Tratamento
19.
J Clin Periodontol ; 47(8): 1016-1025, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31976567

RESUMO

AIMS: To assess the long-term clinical and radiographic results of implants placed using osteotome sinus floor elevation (OSFE) with or without bone grafting. MATERIALS AND METHODS: Forty-five patients were randomly assigned into two groups: Group 1 (OSFE with deproteinized bovine bone mineral) and Group 2 (OSFE without grafting). The patients were recalled at 1, 3, 5 and 10 years after surgery. The implant survival, endo-sinus bone gain (ESBG), marginal bone loss (MBL), peri-implant bone height (PBH, distance from the most coronal level to the most apical level of bone-to-implant contact), prosthesis survival and hardware complications, and peri-implant soft tissue conditions were assessed. RESULTS: Forty patients attended the 10-year examination. Mean residual bone height was 4.58 ± 1.28 mm. The 10-year cumulative survival rate was 90.7% for Group 1 and 95.0% for Group 2. The PBH was 5.89 ± 1.24 mm for Group 1 and 5.74 ± 1.43 mm for Group 2 at 10 years. The ESBG of both groups remained stable after 3 years. Two-thirds of the implants were free of hardware complications. No significant differences in MBL and peri-implant tissue parameters were found. CONCLUSION: OSFE with or without grafting both yielded predictable clinical outcomes with similar PBH (ClinicalTrials.gov. NCT01619956).


Assuntos
Perda do Osso Alveolar , Implantes Dentários , Levantamento do Assoalho do Seio Maxilar , Perda do Osso Alveolar/diagnóstico por imagem , Perda do Osso Alveolar/cirurgia , Animais , Transplante Ósseo , Bovinos , Implantação Dentária Endóssea , Humanos , Maxila/cirurgia , Seio Maxilar/diagnóstico por imagem , Seio Maxilar/cirurgia , Resultado do Tratamento
20.
Ann Transl Med ; 8(23): 1592, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33437791

RESUMO

BACKGROUND: This study aimed to explore the influence of initial ridge defect morphology on the outcome of guided bone regeneration (GBR) in the anterior maxilla region. METHODS: Cone beam computed tomography (CBCT) examinations of patients who participated in a previous randomized controlled trial were used to assess linear and volumetric changes of bone grafts (LCB and VCB) from immediately (T0) to 6 months (T1) after surgery. The three-dimensional (3D) surface rendering of the initial defect was reconstructed, and morphological variables were defined in mesial-distal, buccal-lingual, and coronal-apical directions. The Spearman correlation, logistic regression model, and receiver operating characteristic (ROC) analyses were used to assess the possible association between initial defect morphological variables and VCB. RESULTS: A total of 62 eligible patients were included in this study. The median value of LCB was less than 20% at different levels, while the corresponding value of VCB was 52.0%. The Spearman correlation analysis showed that the standard deviation of buccal-lingual distance (BLSD) was negatively associated with VCB (r=-0.315, P=0.013), whereas the ratio of maximum coronal-apical/mesial-distal distance (RmCA/mMD) was positively related to VCB (r=0.607, P<0.001). The multivariate regression analysis revealed that the prognosis effect of BLSD (OR: 0.220, 95% CI: 0.074 to 0.655, P=0.0047) and RmCA/mMD (OR: 7.045, 95% CI: 2.361 to 21.024, P=0.0017) remained significant. ROC curve analysis showed that RmCA/mMD could be used to correctly classify VCB in 78.9% patients and BLSD in 71.0% of patients, as classified by the median of VCB. The discrimination value of BLSD and RmCA/mMD revealed the areas under curve (AUC) of 0.71 (95% CI: 0.545 to 0.883) and 0.74 (95% CI: 0.573 to 0.913), respectively. CONCLUSIONS: Within the limitations of this study, the present data confirmed the effect of initial ridge morphology on the GBR outcome in the anterior maxilla region. Specifically, a defect morphology with more BLSD and/or lower RmCA/mMD may significantly decrease the resorption amount of grafted bone.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA