Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Appl Lab Med ; 8(3): 535-550, 2023 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-36533519

RESUMO

BACKGROUND: Abnormal liver function is a common manifestation of human disease and may also occur in approved and investigational medications as drug-induced liver injury (DILI). Capillary blood collection devices may allow for more frequent and convenient measurement outside of the clinic. Validation of such approaches is lacking. METHODS: This prospective, biospecimens collection study evaluated the Tasso+ in patients with abnormal liver tests (NCT05259618). The primary objective was to define the concordance of alanine aminotransferase (ALT) obtained via Tasso+ compared to standard venipuncture. Secondary objectives included measurement of 14 other analytes and patient surveys. At the time of venipuncture, 2 Tasso+ samples were collected: one was centrifuged and shipped, and the other was refrigerated and shipped as whole blood. RESULTS: Thirty-six patients with elevated ALT values were enrolled. In total, 100 venipuncture, 50 Tasso+ centrifuged, and 48 Tasso+ whole blood samples were obtained. Tasso+ centrifuged samples demonstrated concordance correlation coefficients (CCC) of >0.99 for ALT, alkaline phosphatase (ALP), aspartate aminotransferase (AST), and total bilirubin and CCC >0.95 for albumin, chloride, enzymatic creatinine, serum glucose, magnesium, and phosphorus. Tasso+ whole blood showed CCC of >0.99 for AST, bilirubin total, and enzymatic creatinine and CCC >0.95 for ALT, ALP, albumin, magnesium, and phosphorus. Hemolysis was comparable across the 3 sample types, but its impact was reflected in the Tasso+ potassium data. Patient feedback indicated a very favorable patient experience. CONCLUSIONS: The capillary blood collection device, Tasso+, showed substantial to almost perfect concordance to standard venipuncture for measurement of abnormal liver function. Studies are ongoing to validate longitudinal sampling outside of the clinic. Clinicaltrials.gov Registration Number: NCT05259618.


Assuntos
Magnésio , Flebotomia , Humanos , Flebotomia/efeitos adversos , Estudos Prospectivos , Creatinina , Fosfatase Alcalina , Bilirrubina , Fígado , Fósforo , Albuminas
2.
PLoS One ; 16(9): e0255841, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34473717

RESUMO

BACKGROUND: Efforts to minimize COVID-19 exposure during the current SARS-CoV-2 pandemic have led to limitations in access to medical care and testing. The Tasso-SST kit includes all of the components necessary for remote, capillary blood self-collection. In this study, we sought to investigate the accuracy and reliability of the Tasso-SST device as a self-collection device for measurement of SARS-CoV-2 IgG antibodies. METHODS: Capillary blood was obtained via unsupervised and supervised application of the Tasso-SST device, and venous blood was collected by standard venipuncture. Unsupervised self-collected blood samples underwent either extreme summer or winter-simulated shipping conditions prior to testing. Sera obtained by all three methods were tested concurrently using the EuroImmun anti-SARS-CoV-2 S1 IgG assay in a CLIA-certified clinical laboratory. RESULTS: Successful Tasso-SST capillary blood collection by unsupervised and supervised administration was completed by 93.4% and 94.5% of participants, respectively. Sera from 56 participants, 55 with documented (PCR+) COVID-19, and 33 healthy controls were then tested for anti-SARS-CoV-2 IgG antibodies. Compared to venous blood results, Tasso-SST-collected (unstressed) and the summer- and winter-stressed blood samples demonstrated Deming regression slopes of 1.00 (95% CI: 0.99-1.02), 1.00 (95% CI: 0.98-1.01), and 0.99 (95% CI: 0.97-1.01), respectively, with an overall accuracy of 98.9%. CONCLUSIONS: Capillary blood self-collection using the Tasso-SST device had a high success rate. Moreover, excellent concordance was found for anti-SARS-CoV-2 IgG results between Tasso-SST capillary and standard venous blood-derived sera. The Tasso-SST device should enable widespread collection of capillary blood for testing without medical supervision, facilitating epidemiologic studies.


Assuntos
Anticorpos Antivirais/imunologia , Coleta de Amostras Sanguíneas/métodos , Teste para COVID-19/métodos , COVID-19/diagnóstico , Imunoglobulina G/imunologia , SARS-CoV-2/imunologia , Adulto , Idoso , Coleta de Amostras Sanguíneas/instrumentação , COVID-19/epidemiologia , COVID-19/virologia , Teste para COVID-19/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias , Reprodutibilidade dos Testes , SARS-CoV-2/fisiologia , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA