Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
Eur Heart J ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747246

RESUMO

BACKGROUND AND AIMS: Transcatheter aortic valve implantation (TAVI) has become the first choice to treat older patients with severe symptomatic aortic stenosis (AS). This study aimed to compare TAVI with surgery in low-risk patients ≤ 75 years of age, including both tricuspid and bicuspid AS. METHODS: The NOTION-2 trial enrolled and 1:1 randomized low-risk patients aged ≤ 75 years with severe symptomatic AS to TAVI or surgery. The primary endpoint was a composite of all-cause mortality, stroke or rehospitalization (related to the procedure, valve or heart failure) at 12 months. RESULTS: A total of 370 patients were enrolled with a mean age of 71.1 years and a median Society of Thoracic Surgeons risk score of 1.1%. A total of 100 patients had bicuspid AS. The 1-year incidence of the primary endpoint was 10.2% in the TAVI group and 7.1% in the surgery group (absolute risk difference 3.1%; 95% confidence interval [CI], -2.7% to 8.8%; hazard ratio (HR) 1.4, 95% CI: 0.7 to 2.9; p=0.3). Patients with TAVI, when compared to surgery, had lower risk of major bleeding and new-onset atrial fibrillation and higher risk of non-disabling stroke, permanent pacemaker implantation and moderate-or-greater paravalvular regurgitation. The risk of the primary composite endpoint was 8.7% and 8.3% in patients with tricuspid AS (HR 1.0, 95% CI: 0.5 to 2.3) and 14.3% and 3.9% in patients with bicuspid AS (HR 3.8, 95% CI: 0.8 to 18.5) treated with TAVI or surgery, respectively (P for interaction=0.1). CONCLUSIONS: Among low-risk patients aged ≤ 75 years with severe symptomatic AS, the rate of the composite of death, stroke, or rehospitalization at one year was similar between TAVI and surgery. TAVI outcomes in young bicuspid AS patients warrant caution and should be further investigated. (NOTION-2, ClinicalTrials.gov, NCT02825134).

2.
N Engl J Med ; 390(16): 1481-1492, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38587995

RESUMO

BACKGROUND: The benefit of fractional flow reserve (FFR)-guided complete revascularization in patients with ST-segment elevation myocardial infarction (STEMI) and multivessel coronary artery disease remains unclear. METHODS: In this multinational, registry-based, randomized trial, we assigned patients with STEMI or very-high-risk non-STEMI (NSTEMI) and multivessel disease who were undergoing primary percutaneous coronary intervention (PCI) of the culprit lesion to receive either FFR-guided complete revascularization of nonculprit lesions or no further revascularization. The primary outcome was a composite of death from any cause, myocardial infarction, or unplanned revascularization. The two key secondary outcomes were a composite of death from any cause or myocardial infarction and unplanned revascularization. RESULTS: A total of 1542 patients underwent randomization, with 764 assigned to receive FFR-guided complete revascularization and 778 assigned to receive culprit-lesion-only PCI. At a median follow-up of 4.8 years (interquartile range, 4.3 to 5.2), a primary-outcome event had occurred in 145 patients (19.0%) in the complete-revascularization group and in 159 patients (20.4%) in the culprit-lesion-only group (hazard ratio, 0.93; 95% confidence interval [CI], 0.74 to 1.17; P = 0.53). With respect to the secondary outcomes, no apparent between-group differences were observed in the composite of death from any cause or myocardial infarction (hazard ratio, 1.12; 95% CI, 0.87 to 1.44) or unplanned revascularization (hazard ratio, 0.76; 95% CI, 0.56 to 1.04). There were no apparent between-group differences in safety outcomes. CONCLUSIONS: Among patients with STEMI or very-high-risk NSTEMI and multivessel coronary artery disease, FFR-guided complete revascularization was not shown to result in a lower risk of a composite of death from any cause, myocardial infarction, or unplanned revascularization than culprit-lesion-only PCI at 4.8 years. (Funded by the Swedish Research Council and others; FULL REVASC ClinicalTrials.gov number, NCT02862119.).


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Revascularização Miocárdica , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/terapia , Seguimentos , Estimativa de Kaplan-Meier , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/métodos , Sistema de Registros , Infarto do Miocárdio com Supradesnível do Segmento ST/etiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Revascularização Miocárdica/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Reoperação , Europa (Continente) , Australásia
3.
EuroIntervention ; 20(6): e363-e375, 2024 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-38506737

RESUMO

BACKGROUND: There is a lack of comparative data on transcatheter aortic valve implantation (TAVI) in degenerated surgical prostheses (valve-in-valve [ViV]). AIMS: We sought to compare outcomes of using two self-expanding transcatheter heart valve (THV) systems for ViV. METHODS: In this retrospective multicentre registry, we included consecutive patients undergoing transfemoral ViV using either the ACURATE neo/neo2 (ACURATE group) or the Evolut R/PRO/PRO+ (EVOLUT group). The primary outcome measure was technical success according to Valve Academic Research Consortium (VARC)-3. Secondary outcomes were 30-day all-cause mortality, device success (VARC-3), coronary obstruction (CO) requiring intervention, rates of severe prosthesis-patient mismatch (PPM), and aortic regurgitation (AR) ≥moderate. Comparisons were made after 1:1 propensity score matching. RESULTS: The study cohort comprised 835 patients from 20 centres (ACURATE n=251; EVOLUT n=584). In the matched cohort (n=468), technical success (ACURATE 92.7% vs EVOLUT 88.9%; p=0.20) and device success (69.7% vs 73.9%; p=0.36) as well as 30-day mortality (2.8% vs 1.6%; p=0.392) were similar between the two groups. The mean gradients and rates of severe PPM, AR ≥moderate, or CO did not differ between the groups. Technical and device success were higher for the ACURATE platform among patients with a true inner diameter (ID) >19 mm, whereas a true ID ≤19 mm was associated with higher device success - but not technical success - among Evolut recipients. CONCLUSIONS: ViV TAVI using either ACURATE or Evolut THVs showed similar procedural outcomes. However, a true ID >19 mm was associated with higher device success among ACURATE recipients, whereas in patients with a true ID ≤19 mm, device success was higher when using Evolut.


Assuntos
Insuficiência da Valva Aórtica , Bioprótese , Oclusão Coronária , Substituição da Valva Aórtica Transcateter , Humanos , Catéteres , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Valvas Cardíacas , Sistema de Registros , Substituição da Valva Aórtica Transcateter/efeitos adversos
4.
Struct Heart ; 8(2): 100231, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38481713

RESUMO

Background: Transcatheter aortic valve implantation (TAVI) has become a safe procedure. However, complications occur, including uncommon complications such as valve malposition, which requires the implantation of an additional rescue valve (rescue-AV). The aim was to study the occurrence and outcomes of rescue-AV in a nationwide registry. Methods: The Swedish national TAVI registry was used as the primary data source, where all 6706 TAVI procedures from 2016 to 2021 were retrieved. Nontransfemoral access and planned valve-in-valve were excluded. In total, 79 patients were identified as having had a rescue-AV, and additional detailed data were collected for these patients. This dataset was analyzed for any characteristics that could predispose patients to a rescue-AV. The outcome of patients receiving rescue-AV also was studied. Results: Of the 5948 patients in the study, 1.3% had a rescue-AV. There were few differences between patients receiving 1 valve and rescue-AV patients. For patients receiving a rescue-AV, the 30-day mortality was 15.2% compared to 1.6% in the control group. A poor outcome after rescue-AV was often associated with a second complication; for example, stroke, need for emergency surgery, or heart failure. Among the patients with rescue-AV who survived at least 30 days, landmark analyses showed similar survival rates compared to the control group. Conclusions: Among TAVI patients in a nationwide register, rescue-AV occurred in 1.3% of patients. The 30-day mortality in patients receiving rescue-AV was high, but long-term outcome among 30-day survivors was similar to the control group.

5.
JACC Case Rep ; 29(3): 102192, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38361571

RESUMO

Misloading during transcatheter aortic valve replacement (TAVR) is rare but can cause unpredictable valve release if unrecognized. We describe how to identify a misloaded ACURATE neo2 device, and 3 methods to solve this by using a modified technique of valve deployment, ipsilateral extraction, and contralateral valve externalization with extracorporeal valve release.

6.
Int J Cardiol ; 400: 131792, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38244892

RESUMO

BACKGROUND: ACURATE neo2 (Neo2) implantation is performed after systematic Balloon Aortic Valvuloplasty (BAV) in most patients. No reports exist about the feasibility and safety of direct Neo2 transcatheter aortic valve implantation (TAVI) in comparison to the standard practice. AIM: We aimed to identify the patients' baseline anatomical characteristics, procedural, and early post-procedural outcomes in patients treated using Neo2 with and without BAV. METHODOLOGY: This is a retrospective multicentre analysis of 499 patients with severe aortic stenosis who underwent TAVI using Neo2. The comparison was done according to the performance or omission of BAV. Echocardiography and computed tomography were analysed by an independent Core Lab. Propensity score matching (PSM) was performed based on the annular diameter and AV calcium volume, which identified 84 matched pairs. RESULTS: Among the cohort included, 391 (78%) patients received BAV (BAV-yes) and 108 (22%) were not attempted (BAV-no or Direct TAVI). Patients in BAV-no cohort had smaller annular diameter (22.6 vs 23.4 mm; p < 0.001) and lower calcium volume (163 vs 581 mm3; p < 0.001) compared to BAV-yes cohort. In the matched cohort, VARC-3 device technical success was similar (95%) and all other outcome measures were statistically comparable between cohorts. CONCLUSION: Direct TAVI using ACURATEneo2 without pre-TAVI balloon aortic valvuloplasty in patients with mild or less valve calcifications might be feasible and associated with comparable early outcomes compared to patients with similar anatomical features undergoing systematic balloon valvuloplasty.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/métodos , Cálcio , Resultado do Tratamento , Estudos Retrospectivos , Desenho de Prótese
7.
EuroIntervention ; 20(1): 85-94, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37982152

RESUMO

BACKGROUND: Transcatheter aortic valve implantation is an effective treatment for patients with aortic stenosis; however, complications related to paravalvular leakage (PVL) persist, including increased risk of mortality, cardiovascular mortality, and rehospitalisation. AIMS: We sought to evaluate the clinical outcomes and valve performance at 1 year in patients with severe aortic stenosis treated with the ACURATE neo2 valve in a post-market clinical setting. METHODS: Valve Academic Research Consortium-2 safety events were assessed up to 1 year. Independent core laboratories evaluated echocardiographic measures of valve performance and hypoattenuated leaflet thickening (HALT; as measured by four-dimensional computed tomography). RESULTS: The study enrolled 250 patients (64% female; mean age: 81 years; baseline Society of Thoracic Surgeons risk score: 2.9±2.0%); 246 patients were implanted with ACURATE neo2. All-cause mortality was 0.8% at 30 days and 5.1% at 1 year. The 1-year rates for stroke and disabling stroke were 3.0% and 1.3%, respectively. Overall, HALT of >50% leaflet involvement of at least one leaflet was present in 9% of patients at 30 days and in 12% of patients at 1 year. No association was observed between the presence of HALT and 1-year clinical or haemodynamic outcomes. Early haemodynamic improvements were maintained up to 1 year (mean aortic valve gradient: 47.6±14.5 mmHg at baseline, 7.6±3.2 mmHg at 1 year; mean aortic valve area: 0.7±0.2 cm2 at baseline, 1.7±0.4 cm2 at 1 year). At 1 year, 99% of patients had mild or no/trace PVL (<1% had moderate PVL; no patient had severe PVL). CONCLUSIONS: The study outcomes confirm favourable performance and safety up to 1 year in patients treated with ACURATE neo2 in routine clinical practice. (ClinicalTrials.gov: NCT04655248).


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
8.
Front Cardiovasc Med ; 10: 1161779, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37529710

RESUMO

Paravalvular leak (PVL) is a shortcoming that can erode the clinical benefits of transcatheter valve replacement (TAVR) and therefore a readily applicable method (aortography) to quantitate PVL objectively and accurately in the interventional suite is appealing to all operators. The ratio between the areas of the time-density curves in the aorta and left ventricular outflow tract (LVOT-AR) defines the regurgitation fraction (RF). This technique has been validated in a mock circulation; a single injection in diastole was further tested in porcine and ovine models. In the clinical setting, LVOT-AR was compared with trans-thoracic and trans-oesophageal echocardiography and cardiac magnetic resonance imaging. LVOT-AR > 17% discriminates mild from moderate aortic regurgitation on echocardiography and confers a poor prognosis in multiple registries, and justifies balloon post-dilatation. The LVOT-AR differentiates the individual performances of many old and novel devices and is being used in ongoing randomized trials and registries.

9.
J Am Heart Assoc ; 12(15): e029464, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37489732

RESUMO

Background ACURATE neo2 is a transcatheter aortic valve implantation system consisting of a self-expanding bioprosthetic valve with supra-annular leaflet position and featuring innovations to facilitate placement accuracy and reduce paravalvular regurgitation. Methods and Results The goal of the Early neo2 (Early neo2 Registry of the ACURATE neo2 TAVI Prosthesis) was to gather real-life data on safety and efficacy in a European transcatheter aortic valve implantation population treated with ACURATE neo2. Data were collected from 554 consecutive patients treated with ACURATE neo2 at 12 European sites (mean age, 82 years; 66% women; mean European System for Cardiac Operative Risk Evaluation II, 4.5%±3.8%) between September 2020 and March 2021. The composite primary end point was the occurrence of any of the following: postoperative (in-hospital) paravalvular regurgitation grade ≥2, in-hospital acute kidney injury stage 3, postoperative pacemaker implantation, 30-day death, and 30-day stroke. The primary end point occurred in 12.6% of patients. The 30-day rates for all-cause death and all stroke were 1.3% and 2.7%, respectively, and 1.5% of patients exhibited stage 3 acute kidney injury. A total of 34 patients (6.2%) received a postoperative permanent pacemaker. Per core laboratory-adjudicated echocardiographic analysis, mean postoperative aortic valve gradient was 7.6±3.3 mm Hg, and 2.8% of patients exhibited paravalvular regurgitation grade ≥2. Conclusions In this report of postmarket use of the ACURATE neo2 valve in a real-world transcatheter aortic valve implantation population, patients exhibited favorable postoperative hemodynamics and clinical outcomes and a low rate of postoperative pacemaker implantation.


Assuntos
Injúria Renal Aguda , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso de 80 Anos ou mais , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Sistema de Registros , Acidente Vascular Cerebral/epidemiologia
10.
EuroIntervention ; 19(4): e352-e362, 2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37334801

RESUMO

BACKGROUND: TAVI is a widely accepted treatment for patients with severe aortic stenosis (AS). Despite the adoption of diverse therapies, opportunities remain to develop technologies tailored to provide optimal acute and potential long-term benefits, particularly around haemodynamics, flow and durability. AIMS: We aimed to evaluate the safety and feasibility of the DurAVR transcatheter heart valve (THV), a first-in-class biomimetic valve, in the treatment of patients with symptomatic severe AS. METHODS: This was a first-in-human (FIH), prospective, non-randomised, single-arm, single-centre study. Patients with severe, symptomatic AS of any surgical risk and who were eligible for the DurAVR THV prosthesis were recruited; they were assessed at baseline, 30 days, 6 months, and 1 year post-procedure for implant success, haemodynamic performance, and safety. RESULTS: Thirteen patients (73.9±6.4 years old, 77% female) were enrolled. The DurAVR THV was successfully implanted in 100% of cases with no device-related complications. One access site complication, one permanent pacemaker implantation, and one case of moderate aortic regurgitation occurred. Otherwise, no deaths, stroke, bleeding, reinterventions, or myocardial infarction were reported during any of the follow-up visits. Despite a mean annulus size of 22.95±1.09 mm, favourable haemodynamic results were observed at 30 days (effective orifice area [EOA] 2.00±0.17 cm2, and mean pressure gradient [MPG] 9.02±2.68 mmHg) and were sustained at 1 year (EOA 1.96±0.11 cm2, MPG 8.82±1.38 mmHg), resulting in zero patients with any degree of prosthesis-patient mismatch. Additionally, new valve performance measures derived from cardiovascular magnetic resonance displayed restoration of laminar flow, consistent with a predisease state, in conjunction with a mean coaptation length of 8.3±1.7 mm. CONCLUSIONS: Preliminary results from the FIH study with DurAVR THV demonstrate a good safety profile with promising haemodynamic performance sustained at 1 year and restoration of near-normal flow dynamics. Further clinical investigation is warranted to evaluate how DurAVR THV may play a role in addressing the challenge of lifetime management in AS patients.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Estudos de Viabilidade , Biomimética , Resultado do Tratamento , Desenho de Prótese
11.
JACC Case Rep ; 11: 101777, 2023 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-37077443

RESUMO

An 80-year-old man with a supra-annular transcatheter aortic valve (TAV) prosthesis presented with severe transvalvular aortic regurgitation 18 months after the TAV replacement procedure. The authors report the first ever valve-in-valve procedure using BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction) in such a supra-annular TAV prosthesis. Minimal paravalvular leakage, normal coronary artery flow, and easy coronary access were seen postimplantation. (Level of Difficulty: Advanced.).

12.
JACC Cardiovasc Interv ; 16(6): 670-677, 2023 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-36990556

RESUMO

BACKGROUND: Commissural alignment has become an important topic in transcatheter aortic valve replacement (TAVR) because it may improve coronary access, facilitate future valve procedures, and possibly improve valve durability. The efficacy of commissural alignment with ACURATE neo2 has not yet been shown in a large population. OBJECTIVES: The authors sought to determine the feasibility and success of attempting commissural alignment in an unselected TAVR population treated with the ACURATE neo2 prosthetic heart valve. METHODS: A total of 170 consecutive patients underwent TAVR with a dedicated implantation technique to align the TAVR valve to the native valve. Using right-left overlap and 3-cusp views, valve orientation was adjusted by rotation of the unexpanded valve at the level of the aortic root. Effectiveness was assessed postprocedure as the degree of misalignment determined by analyzing fluoroscopic valve orientation to corresponding cusp orientation on preprocedural computed tomography. Safety endpoints included mortality, stroke/transient ischemic attack, and additional complications through 30 days. RESULTS: Of 170 patients, 167 (98.2%) could be analyzed for alignment, and all 170, for safety outcomes. Most patients (97%) had successful alignment (≤ mild misalignment), with 80% with commissural alignment, while the degrees of misalignment were 17% mild, 1.2% moderate, 1.8% severe. CONCLUSIONS: In this large evaluation of a commissural alignment technique, alignment was achieved in nearly all patients without safety concerns or impact to procedure duration. Commissural alignment appears effective and safe across all patients with this novel technique.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Fatores de Risco , Desenho de Prótese , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Tomografia Computadorizada Multidetectores
13.
Int J Cardiol ; 377: 26-32, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36640966

RESUMO

BACKGROUND: Cardiac tamponade caused by temporary right ventricular (RV) pacemaker perforation is a rare but serious complication in transcatheter aortic valve replacement (TAVR). AIMS: To study the incidence of temporary pacemaker related cardiac tamponade in TAVR, and the relation to the type of pacemaker lead used in periprocedural temporary transvenous pacing. METHODS: A single center registry of transfemoral TAVRs in 2014-2020. Main inclusion criterion was peri-operative use of a temporary RV pacing lead. Main exclusion criteria were a preoperatively implanted permanent pacemaker or the exclusive use of left ventricular guidewire pacing. Incident cardiac tamponade was classified as pacemaker lead related, or other. Patients were grouped according to type of temporary RV pacing wire. RESULTS: 810 patients were included (age 80.5 ± 7.3 [mean ± standard deviation], female 319, 39.4%). Of these, 566 (69.9%) received a standard RV temporary pacing wire (RV-TPW), and 244 (30.1%) received temporary RV pacing through a permanent, passive pacemaker lead (RV-TPPL). In total, 18 (2.2%) events of cardiac tamponade occurred, 12 (67%) were pacemaker lead related. All pacemaker lead-related cardiac tamponades occurred in the group who received a standard RV-TPW and none in the group who received RV-TPPL (n = 12 [2.1%] vs. n = 0 [0%], p = 0.022). No difference in cardiac tamponade due to other causes was seen between the groups (p = 0.82). CONCLUSIONS: The use of soft-tip RV-TPPL was associated with a lower risk of pacemaker related cardiac tamponade in TAVR. When perioperative pacing is indicated, temporary RV-TPPL may contribute to a significant reduction of cardiac tamponade in TAVR.


Assuntos
Estenose da Valva Aórtica , Tamponamento Cardíaco , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Tamponamento Cardíaco/diagnóstico , Tamponamento Cardíaco/epidemiologia , Tamponamento Cardíaco/etiologia , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos , Estimulação Cardíaca Artificial , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Valva Aórtica/cirurgia
14.
EuroIntervention ; 2022 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-36440588

RESUMO

BACKGROUND: The next-generation ACURATE neo2 transcatheter aortic valve was designed for simplified implantation and to mitigate the risk of paravalvular leak (PVL) compared to the earlier device. AIMS: To collect clinical outcomes and device performance data, including echocardiography and 4-dimensional computed tomography (4D-CT) data, with the ACURATE neo2 transcatheter heart valve in patients with severe aortic stenosis (AS). METHODS: ACURATE neo2 PMCF is a single-arm, multicentre study of patients with severe AS treated in routine clinical practice. The primary safety endpoint was all-cause mortality at 30-days. The primary imaging endpoint was hypo-attenuated leaflet thickening (HALT), measured by core laboratory-adjudicated 4D-CT at 30 days. Secondary endpoints included VARC safety endpoints, procedural success, and evaluation of valve performance via core laboratory-adjudicated echocardiography. RESULTS: The study enrolled 250 patients at 18 European centres (mean age: 80.8 years; 63.6% female; mean STS score: 2.9±2.0%); 246 (98.4%) were successfully treated with ACURATE neo2. The 30-day rates for mortality and disabling stroke were 0.8% and 0%, respectively. The new permanent pacemaker implantation rate was 6.5%. HALT >50% was present in 9.3% of patients at 30 days. Valve haemodynamics improved from baseline to 30 days (mean aortic valve gradient: from 47.6±14.5 mmHg to 8.6±3.9 mmHg; mean aortic valve area: from 0.7±0.2 cm2 to 1.6±0.4 cm2). At 30 days, PVL was evaluated as none/trace in 79.2% of patients, mild in 18.9%, moderate in 1.9%, and severe in 0%. CONCLUSIONS: The study results support the safety and efficacy of TAVI with ACURATE neo2 in patients in routine clinical practice.

15.
Eur Heart J Case Rep ; 6(11): ytac423, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36405539

RESUMO

Background: Congenitally corrected transposition of the great arteries (ccTGA) is a rare congenital heart anomaly with atrioventricular and ventriculoarterial discordance that is often associated with other cardiac and coronary artery anomalies. Here, we report a case of a patient with ccTGA and non-ST elevation myocardial infarction (NSTEMI) with challenging coronary anatomy that was treated with stress-perfusion cardiac magnetic resonance imaging (spCMR) guided percutaneous coronary intervention (PCI). Case summary: A 46-year-old male smoker with ccTGA, dyslipidaemia, diabetes Type 2 managed with dietary restrictions and a family history of premature myocardial infarction, presented with typical chest pain, elevated cardiac troponin levels and ECG-changes indicative of ischaemia. The patient was diagnosed with NSTEMI and underwent initial urgent coronary angiography (CA) without apparent significant stenosis, although the right coronary artery (RCA) could not be selectively investigated. The patient had coronary anatomy 1R-2LCX according to the Leiden convention, which is the usual anatomy in patients with ccTGA. Despite this, CA was challenging due to the different anatomy compared with individuals with normally positioned great vessels. The patient remained highly symptomatic with chest pain at moderate exertion. To improve identification of the anatomic location and extent of ischaemia, we performed spCMR with adenosine. This revealed a limited septal infarction (likely embolic) in the right ventricle and reversible ischaemia in two inferior right ventricular segments. A second angiography, selectively investigating RCA demonstrated a significant stenosis in the distal RCA that was successfully treated with a drug-eluting stent. Fractional flow reserve (FFR) measurements of the left coronary arteries demonstrated hemodynamically non-significant stenosis. The patient's symptoms resolved, and he remained asymptomatic at one month follow-up. Discussion: This ccTGA patient had multiple risk factors for coronary artery disease and presented with NSTEMI. Diagnosis and treatment were challenging due to complex cardiac anatomy and associated different origins of the coronary arteries. We highlight the importance of careful evaluation of the coronary anatomy and functional testing using for example spCMR and FFR to target the culprit coronary vessel(s) in ccTGA complicated by NSTEMI.

16.
J Clin Med ; 11(20)2022 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-36294424

RESUMO

(1) Background: Hemodynamic assessment of prosthetic heart valves using conventional 2D transthoracic Echocardiography-Doppler (2D-TTE) has limitations. Of those, left ventricular outflow tract (LVOT) area measurement is one of the major limitations of the continuity equation, which assumes a circular LVOT. (2) Methods: This study comprised 258 patients with severe aortic stenosis (AS), who were treated with the ACURATE neo2. The LVOT area and its dependent Doppler-derived parameters, including effective orifice area (EOA) and stroke volume (SV), in addition to their indexed values, were calculated from post-TAVI 2D-TTE. In addition, the 3D-LVOT area from pre-procedural MDCT scans was obtained and used to calculate corrected Doppler-derived parameters. The incidence rates of prosthesis patient mismatch (PPM) were compared between the 2D-TTE and MDCT-based methods (3) Results: The main results show that the 2D-TTE measured LVOT is significantly smaller than 3D-MDCT (350.4 ± 62.04 mm2 vs. 405.22 ± 81.32 mm2) (95% Credible interval (CrI) of differences: -55.15, -36.09), which resulted in smaller EOA (2.25 ± 0.59 vs. 2.58 ± 0.63 cm2) (Beta = -0.642 (95%CrI of differences: -0.85, -0.43), and lower SV (73.88 ± 21.41 vs. 84.47 ± 22.66 mL), (Beta = -7.29 (95% CrI: -14.45, -0.14)), respectively. PPM incidence appears more frequent with 2D-TTE- than 3D-MDCT-corrected measurements (based on the EOAi) 8.52% vs. 2.32%, respectively. In addition, significant differences regarding the EOA among the three valve sizes (S, M and L) were seen only with the MDCT, but not on 2D-TTE. (4) Conclusions: The corrected continuity equation by combining the 3D-LVOT area from MDCT with the TTE Doppler parameters might provide a more accurate assessment of hemodynamic parameters and PPM diagnosis in patients treated with TAVI. The ACURATE neo2 THV has a large EOA and low incidence of PPM using the 3D-corrected LVOT area than on 2D-TTE. These findings need further confirmation on long-term follow-up and in other studies.

17.
Int J Cardiol ; 359: 7-13, 2022 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-35427700

RESUMO

BACKGROUND: Arterial access-site related complications constitute a large proportion of adverse events related to cardiac interventions requiring large-bore devices and have significant implications on morbidity, mortality and hospital cost. AIMS: To evaluate the safety and effectiveness of a novel percutaneous plug-based vascular closure device (VCD) in 1000 consecutive patients undergoing transfemoral transcatheter aortic valve implantation (TAVI). METHODS: A single-center observational study evaluating a plug-based VCD (MANTA, Teleflex/Essential Medical Inc., Malvern, Pennsylvania, USA) in patients undergoing TAVI at the Karolinska University Hospital, Stockholm, Sweden. The primary outcome was VCD-related major vascular complication according to the criteria of the Valve Academic Research Consortium (VARC)-2. RESULTS: From May 2017 to September 2020 a total of 1000 consecutive patients underwent transfemoral TAVI with arterial access-site management using the MANTA VCD. VARC-2 major vascular complications occurred in 42 (4.2%) patients: 17 (1.7%) patients intraoperatively received a covered stent, 17 (1.7%) patients underwent surgical repair during hospital stay, 3 (0.3%) patients underwent vascular surgery after discharge, 3 (0.3%) patients had major bleeding and 2 (0.2%) patients had symptoms of claudication with conservative treatment. No significant differences in major complications were seen between individual interventionists irrespective of experience with the device. A larger sheath outer diameter to femoral artery inner diameter ratio was the only factor associated with a significant increase of VCD-related major vascular complications. CONCLUSION: This largest ever real-world evaluation of MANTA for large-bore arteriotomy closure in transfemoral TAVI patients indicates effective and safe arterial access-site management with low complication rates and short learning curve. CLINICAL TRIAL REGISTRATION: http://www. CLINICALTRIALS: gov. Unique identifier: NCT04392492.


Assuntos
Estenose da Valva Aórtica , Cateterismo Periférico , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Cateterismo Periférico/efeitos adversos , Artéria Femoral/cirurgia , Técnicas Hemostáticas , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Dispositivos de Oclusão Vascular/efeitos adversos
18.
Eur Heart J Qual Care Clin Outcomes ; 8(2): 150-160, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-33831187

RESUMO

AIMS: The aim of this study was to investigate the pattern, causes, and predictors of all new hospitalizations in patients who underwent transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: The nationwide Swedish TAVI registry was merged with other mandatory healthcare registries, which enabled the analysis of all TAVI procedures, new hospital admissions, and death between the years 2008 and 2017. A total of 2821 patients underwent TAVI with a mean of 2.5 hospitalizations during a mean follow-up of 2.2 years. Hospitalizations were associated with worse prognosis. Heart failure (HF) was the most common cause of hospitalization with 19% having at least one hospitalization due to HF causing, 16% of all-cause admissions, and 50% of cardiovascular admissions. Male gender, age >90 years, high Charlson Comorbidity Index, atrial fibrillation, present neurologic disease, severe renal impairment, peripheral vascular disease, New York Heart Association class IV, mild or moderate mean aortic valve gradients, and pulmonary hypertension were associated with an increased risk for all-cause hospitalizations or death. For cardiovascular hospitalization or death, the pattern was similar, with the addition of impaired systolic left ventricular function as a predictor. CONCLUSION: Multiple hospitalizations after TAVI are common and are often caused by HF. Reducing the rate of HF hospitalizations is important to mitigate the burden on the healthcare system due to new hospitalizations after TAVI.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Feminino , Hospitalização , Humanos , Masculino , Prognóstico , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
19.
Struct Heart ; 6(4): 100070, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37288334

RESUMO

Background: Periprocedural stroke during transcatheter aortic valve implantation is a rare but devastating complication. The calcified aortic valve is the most likely source of the emboli in a periprocedural stroke. The total load and distribution of calcium in the leaflets, aortic root, and left ventricular outflow tract varies from patient to patient. Consequently, there could be patterns of calcification that are associated with a higher risk of stroke. This study aimed to explore whether the pattern of calcification in the left ventricular outflow tract, annulus, aortic valve, and ascending aorta can be used to predict a periprocedural stroke. Methods: Among the 3282 consecutive patients who received a transcatheter aortic valve implantation in the native valve in Sweden from 2014 to 2018, we identified 52 who had a periprocedural stroke. From the same cohort, a control group of 52 patients was constructed by propensity score matching. Both groups had one missing cardiac computed tomography, and 51 stroke and 51 control patients were blindly reviewed by an experienced radiologist. Results: The groups were well balanced in terms of demographics and procedural data. Of the 39 metrics created to describe calcium pattern, only one differed between the groups. The length of calcium protruding above the annulus was 10.6 mm (interquartile range 7-13.6) for patients without stroke and 8 mm (interquartile range 3-10) for stroke patients. Conclusions: This study could not find any pattern of calcification that predisposes for a periprocedural stroke.

20.
JACC Case Rep ; 3(17): 1828-1835, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34917963

RESUMO

Transcatheter mitral valve replacement carries a risk of left ventricular outflow tract obstruction associated with mortality. We present a case of left ventricular outflow tract obstruction that resolved spontaneously when chords to the anterior mitral leaflet were found to have ruptured. (Level of Difficulty: Advanced.).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA