RESUMO

BACKGROUND: We aimed to determine the incidence, predictors, clinical characteristics, management, and outcomes of infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: This multicenter registry included 53 patients (mean age, 79±8 years; men, 57%) who suffered IE after TAVI of 7944 patients after a mean follow-up of 1.1±1.2 years (incidence, 0.67%, 0.50% within the first year after TAVI). Mean time from TAVI was 6 months (interquartile range, 1-14 months). Orotracheal intubation (hazard ratio, 3.87; 95% confidence interval, 1.55-9.64; P=0.004) and the self-expandable CoreValve system (hazard ratio, 3.12; 95% confidence interval, 1.37-7.14; P=0.007) were associated with IE (multivariate analysis including 3067 patients with individual data). The most frequent causal microorganisms were coagulase-negative staphylococci (24%), followed by Staphylococcus aureus (21%) and enterococci (21%). Vegetations were present in 77% of patients (transcatheter valve leaflets, 39%; stent frame, 17%; mitral valve, 21%). At least 1 complication of IE occurred in 87% of patients (heart failure in 68%). However, only 11% of patients underwent valve intervention (valve explantation and valve-in-valve procedure in 4 and 2 patients, respectively). The mortality rate in hospital was 47.2% and increased to 66% at the 1-year follow-up. IE complications such as heart failure (P=0.037) and septic shock (P=0.002) were associated with increased in-hospital mortality. CONCLUSIONS: The incidence of IE at 1 year after TAVI was 0.50%, and the risk increased with the use of orotracheal intubation and a self-expandable valve system. Staphylococci and enterococci were the most common agents. Although most patients presented at least 1 complication of IE, valve intervention was performed in a minority of patients, and nearly half of the patients died during the hospitalization period.


Assuntos
Endocardite Bacteriana/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Pós-Operatórias/etiologia , Infecções Relacionadas à Prótese/etiologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Endocardite Bacteriana/mortalidade , Endocardite Bacteriana/cirurgia , Enterococcus , Contaminação de Equipamentos , Feminino , Infecções por Bactérias Gram-Positivas/etiologia , Infecções por Bactérias Gram-Positivas/cirurgia , Insuficiência Cardíaca/etiologia , Mortalidade Hospitalar , Humanos , Incidência , Intubação Intratraqueal/efeitos adversos , Estimativa de Kaplan-Meier , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Modelos de Riscos Proporcionais , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/cirurgia , Sistema de Registros , Estudos Retrospectivos , Risco , Infecções Estafilocócicas/etiologia , Infecções Estafilocócicas/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA