Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 32(5): 3248-3259, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35001157

RESUMO

OBJECTIVE: To train and to test for prostate zonal segmentation an existing algorithm already trained for whole-gland segmentation. METHODS: The algorithm, combining model-based and deep learning-based approaches, was trained for zonal segmentation using the NCI-ISBI-2013 dataset and 70 T2-weighted datasets acquired at an academic centre. Test datasets were randomly selected among examinations performed at this centre on one of two scanners (General Electric, 1.5 T; Philips, 3 T) not used for training. Automated segmentations were corrected by two independent radiologists. When segmentation was initiated outside the prostate, images were cropped and segmentation repeated. Factors influencing the algorithm's mean Dice similarity coefficient (DSC) and its precision were assessed using beta regression. RESULTS: Eighty-two test datasets were selected; one was excluded. In 13/81 datasets, segmentation started outside the prostate, but zonal segmentation was possible after image cropping. Depending on the radiologist chosen as reference, algorithm's median DSCs were 96.4/97.4%, 91.8/93.0% and 79.9/89.6% for whole-gland, central gland and anterior fibromuscular stroma (AFMS) segmentations, respectively. DSCs comparing radiologists' delineations were 95.8%, 93.6% and 81.7%, respectively. For all segmentation tasks, the scanner used for imaging significantly influenced the mean DSC and its precision, and the mean DSC was significantly lower in cases with initial segmentation outside the prostate. For central gland segmentation, the mean DSC was also significantly lower in larger prostates. The radiologist chosen as reference had no significant impact, except for AFMS segmentation. CONCLUSIONS: The algorithm performance fell within the range of inter-reader variability but remained significantly impacted by the scanner used for imaging. KEY POINTS: • Median Dice similarity coefficients obtained by the algorithm fell within human inter-reader variability for the three segmentation tasks (whole gland, central gland, anterior fibromuscular stroma). • The scanner used for imaging significantly impacted the performance of the automated segmentation for the three segmentation tasks. • The performance of the automated segmentation of the anterior fibromuscular stroma was highly variable across patients and showed also high variability across the two radiologists.


Assuntos
Aprendizado Profundo , Próstata , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Pelve , Próstata/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA