Resultados 1 - 9 de 9
Filtrar
1.
J Chromatogr A ; 1722: 464869, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38604057

RESUMO

Hydrodynamics, efficiency, and loading capacity of two semi-packed columns with different cross sections (NANO 315 µm x 18 µm; CAP 1000 µm x 28 µm) and similar pillar diameter and pillar-pillar distance (respectively 5 µm and 2.5 µm) have been compared in high-pressure gas chromatography. A flow prediction tool has been first designed to determine pressure variations and hold-up time across the chromatographic system taking into account the rectangular geometry of the ducts into the semi-packed columns. Intrinsic values of Height Equivalent to Theoretical Plate were determined for NANO and CAP columns using helium as carrier gas and similar values have been obtained (30 µm) for the two columns. Loading capacity of semi-packed columns were determined for decane at 70 °C using helium, and the highest value was obtained from CAP column (larger cross section and stationary phase content). Finally, significant HETP improvement (down to 15 µm) and peak shape were observed when carbon dioxide was used as carrier gas, suggesting mobile phase adsorption on stationary phase in high pressure conditions.


Assuntos
Hélio , Pressão , Cromatografia Gasosa/métodos , Cromatografia Gasosa/instrumentação , Hélio/química , Hidrodinâmica , Dióxido de Carbono/química , Adsorção
2.
Nanomaterials (Basel) ; 13(16)2023 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-37630900

RESUMO

In this paper, a microconductometric sensor has been designed, based on a chitosan composite including alcohol dehydrogenase-and its cofactor-and gold nanoparticles, and was calibrated by differential measurements in the headspace of aqueous solutions of ethanol. The role of gold nanoparticles (GNPs) was crucial in improving the analytical performance of the ethanol sensor in terms of response time, sensitivity, selectivity, and reproducibility. The response time was reduced to 10 s, compared to 21 s without GNPs. The sensitivity was 416 µS/cm (v/v%)-1 which is 11.3 times higher than without GNPs. The selectivity factor versus methanol was 8.3, three times higher than without GNPs. The relative standard deviation (RSD) obtained with the same sensor was 2%, whereas it was found to be 12% without GNPs. When the air from the operator's mouth was analyzed just after rinsing with an antiseptic mouthwash, the ethanol content was very high (3.5 v/v%). The background level was reached only after rinsing with water.

3.
Talanta ; 257: 124359, 2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-36801761

RESUMO

Nano-gravimetric detector (NGD) has been recently introduced as miniaturized gas chromatography detector. The NGD response is based on an adsorption-desorption mechanism of compounds between the gaseous phase and the NGD porous oxide layer. The NGD response was characterized by hyphenating NGD in-line with FID detector and a chromatographic column. Such method led to the full adsorption-desorption isotherms of several compounds in a single run. Langmuir model was used to describe the experimental isotherms, and the initial slope of the isotherm (Mm.KT) obtained at low gas concentration was used to compare the NGD response for different compounds (good repeatability was demonstrated with a relative standard deviation lower than 3%). The column-NGD-FID hyphenated method was validated using alkane compounds according to the number of carbon atoms in the alkyl chain and to the NGD temperature (all results agreed with thermodynamic relations associated to partition coefficient). Furthermore, relative response factor to alkanes, for ketones, alkylbenzenes, and fatty acid methyl esters have been obtained. These relative response index values led to easier calibration of NGD. The established methodology can be used for any sensor characterization based on adsorption mechanism.

4.
J Chromatogr A ; 1595: 174-179, 2019 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-30799064

RESUMO

Compared to conventionnal bench top instruments, on-line GC analyzers require specific characteristics. On one hand, for some applications operating with a reactor pressure as high as several tens of bars, sample pressure has to be reduced before GC separation, or specific valves and columns have to be designed to perform separation with high carrier gas inlet pressure. On the other hand, informative detectors such as mass spectrometer are valuable but low maintenance detectors are prefered. To fit these two requirements (sampling at high pressure without decompression stage, and informative detector with low maintenance), short monolithic silica capillary column operated with inlet pressure as high as 60 bar has been hyphenated to VUV detector. Injection and column performance have been first investigated. The system has been optimized by adjusting split ratio at high pressure and by tuning two main VUV detector parameters ("average number" linked to data point averaging and make-up gas pressure) to decrease the limit of quantification. The optimization stage led to a set of experimental parameters which is a good compromise between signal-to-noise ratio and chromatographic efficiency. Finally, the hyphenated monolithic column has be used to partially separate a mixture of methane, ethane, carbon monoxide and carbon dioxide within 15 s, and the VUV deconvolution capabilities have been exploited to overcome coelution and finally separate individual signals.


Assuntos
Técnicas de Química Analítica/instrumentação , Técnicas de Química Analítica/métodos , Hidrocarbonetos/isolamento & purificação , Dióxido de Silício/química , Espectrofotometria Ultravioleta , Cromatografia Gasosa , Hidrocarbonetos/química , Pressão , Vácuo
5.
Sensors (Basel) ; 19(1)2019 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-30621159

RESUMO

In this work, an enzymatic sensor, based on a bionanocomposite film consisting of a polyelectrolyte complex (PEC) (Chitosan/kappa-carrageenan) doped with gold nanoparticles (AuNPs) encapsulating glucose oxidase (GOD) deposited on a gold electrode (Au) for glucose sensing, is described. Using the electrocatalytic synergy of AuNPs and GOD as a model of enzyme, the variation of the current (µA) as a function of the log of the glucose concentration (log [glucose]), shows three times higher sensitivity for the modified electrode (283.9) compared to that of the PEC/GOD modified electrode (93.7), with a detection limit of about 5 µM and a linearity range between 10 µM and 7 mM. The response of the PEC/AuNPs/GOD based biosensor also presents good reproducibility, stability, and negligible interfering effects from ascorbic acid, uric acid, urea, and creatinine. The applicability of the PEC/AuNPs/GOD based biosensor was tested in glucose-spiked saliva samples and acceptable recovery rates were obtained.


Assuntos
Técnicas Biossensoriais , Glucose/isolamento & purificação , Nanopartículas Metálicas/química , Nanocompostos/química , Carragenina/química , Quitosana/química , Eletroquímica , Enzimas Imobilizadas/química , Glucose/química , Glucose Oxidase/química , Ouro/química
6.
J Chromatogr A ; 1530: 171-175, 2017 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-29157607

RESUMO

The vacuum ultraviolet detector (VUV) is a very effective tool for chromatogram deconvolution and peak identification, and can also be used for quantification. To avoid quantitative issues in relation to time drift, such as variation of peak area or peak height, the detector response type has to be well defined. Due to the make-up flow and pressure regulation of make-up, the detector response (height of the peak) and peak area appeared to be dependent on experimental conditions such as inlet pressure and make-up pressure. Even if for some experimental conditions, VUV looks like mass-flow sensitive detector, it has been demonstrated that VUV is a concentration sensitive detector.


Assuntos
Cromatografia/instrumentação , Raios Ultravioleta , Vácuo , Peso Molecular , Pressão , Fatores de Tempo
7.
J Chromatogr A ; 1504: 105-111, 2017 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-28495079

RESUMO

80% vinyltrimethoxysilane-based hybrid silica monoliths (80-VTMS), which have been initially developed for separation in reversed-phase liquid chromatography, have been investigated in high pressure gas chromatography separations (carrier gas pressure up to 60bar) and compared to silica monolithic columns. The behavior of both silica and 80-VTMS monolithic columns was investigated using helium, nitrogen and carbon dioxide as carrier gas. The efficiency of 80-VTMS monolithic columns was shown to vary differently than silica monolithic columns according to the temperature and the carrier gas used. Carrier gas nature was a significant parameter on the retention for both silica and vinyl columns in relation to its adsorption onto the stationary phase in such high pressure conditions. The comparison of retention and selectivity between 80-VTMS monoliths and silica was performed under helium using the logarithm of the retention factor according to the number of carbon atoms combined to Kovats indexes. The very good performances of these columns were demonstrated, allowing the separation of 8 compounds in less than 1min.


Assuntos
Cromatografia Gasosa/instrumentação , Dióxido de Silício/química , Adsorção , Porosidade , Pressão , Temperatura
8.
J Chromatogr A ; 1460: 153-9, 2016 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-27432790

RESUMO

In order to analyze light hydrocarbons mixtures with silica monolithic columns, a conventional gas chromatograph was modified to work with carrier gas pressure as high as 60bar. To understand hydrodynamic flow and retention with short columns (less than 30cm), special attention was required due to the temperature difference between the oven area and the FID detector which contain a significant length of the column. Efficiency and selectivity using various carrier gases (helium, nitrogen and carbon dioxide) at different inlet pressure for different oven temperature were studied. Carrier gas nature was a very significant parameter: on one side, linked to adsorption mechanism for gases like nitrogen and carbon dioxide onto the stationary phase modifying retention and selectivity, on the other side in relation to the minimum theoretical plate height which was as low as 15µm (66 000 platem(-1)) using carbon dioxide as carrier gas. The chromatographic system was then used to separate methane, ethane, ethylene, acetylene, propane, cyclopropane, and butane in less than 30s.


Assuntos
Cromatografia Gasosa , Dióxido de Silício/química , Gases/química , Hidrocarbonetos/química , Hidrodinâmica , Pressão
9.
Carbohydr Polym ; 150: 159-65, 2016 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-27312625

RESUMO

Low methoxyl pectin is known to gel with divalent cations (e.g. Ca(2+), Zn(2+)). In this study, a new way of pectin gelation in the presence of an active pharmaceutical ingredient, chlorhexidine (CX), was highlighted. Thus chlorhexidine interactions with pectin were investigated and compared with the well-known pectin/Ca(2+) binding model. Gelation mechanisms were studied by several physico-chemical methods such as zeta potential, viscosity, size measurements and binding isotherm was determined by Proton Nuclear Magnetic Resonance Spectroscopy ((1)H NMR). The binding process exhibited similar first two steps for both divalent ions: a stoichiometric monocomplexation of the polymer followed by a dimerization step. However, stronger interactions were observed between pectin and chlorhexidine. Moreover, the dimerization step occurred under stoichiometric conditions with chlorhexidine whereas non-stoichiometric conditions were involved with calcium ions. In the case of chlorhexidine, an additional intermolecular binding occurred in a third step.


Assuntos
Fenômenos Químicos , Clorexidina/química , Pectinas/química , Cálcio/química , Géis , Soluções , Viscosidade