Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Biomech Eng ; 146(10)2024 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-38652582

RESUMO

Penn State University is developing a pediatric total artificial heart (TAH) as a bridge-to-transplant device that supports infants and small children with single ventricle anomalies or biventricular heart failure to address high waitlist mortality rates for pediatric patients with severe congenital heart disease (CHD). Two issues with mechanical circulatory support devices are thrombus formation and thromboembolic events. This in vitro study characterizes flow within Penn State's pediatric total artificial heart under physiological operating conditions. Particle image velocimetry (PIV) is used to quantify flow within the pump and to calculate wall shear rates (WSRs) along the internal pump surface to identify potential thrombogenic regions. Results show that the diastolic inflow jets produce sufficient wall shear rates to reduce thrombus deposition potential along the inlet side of the left and right pumps. The inlet jet transitions to rotational flow, which promotes wall washing along the apex of the pumps, prevents flow stasis, and aligns flow with the outlet valve prior to systolic ejection. However, inconsistent high wall shear rates near the pump apex cause increased thrombogenic potential. Strong systolic outflow jets produce high wall shear rates near the outlet valve to reduce thrombus deposition risk. The right pump, which has a modified outlet port angle to improve anatomical fit, produces lower wall shear rates and higher thrombus susceptibility potential (TSP) compared to the left pump. In summary, this study provides a fluid dynamic understanding of a new pediatric total artificial heart and indicates thrombus susceptibility is primarily confined to the apex, consistent with similar pulsatile heart pumps.


Assuntos
Coração Artificial , Hidrodinâmica , Humanos , Reologia , Criança , Trombose , Modelos Cardiovasculares
2.
ASAIO J ; 69(12): 1065-1073, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37549654

RESUMO

Congenital heart disease affects approximately 40,000 infants annually in the United States with 25% requiring invasive treatment. Due to limited number of donor hearts and treatment options available for children, pediatric ventricular assist devices (PVADs) are used as a bridge to transplant. The 12cc pneumatic Penn State PVAD is optimized to prevent platelet adhesion and thrombus formation at patient nominal conditions; however, children demonstrate variable blood hematocrit and elevated heart rates. Therefore, with pediatric patients exhibiting greater variability, particle image velocimetry is used to evaluate the PVAD with three non-Newtonian hematocrit blood analogs (20%, 40%, and 60%) and at two beat rates (75 and 120 bpm) to understand the device's performance. The flow fields demonstrate a strong inlet jet that transitions to a solid body rotation during diastole. During systole, the rotation dissipates and reorganizes into an outlet jet. This flow field is consistent across all hematocrits and beat rates but at a higher velocity magnitude during 120 bpm. There are also minor differences in flow field timing and surface washing due to hematocrit. Therefore, despite patient differences in hematocrit or required pumping output, thorough surface washing can be achieved in the PVAD by altering operating conditions, thus reducing platelet adhesion potential.


Assuntos
Transplante de Coração , Coração Auxiliar , Lactente , Criança , Humanos , Hematócrito , Fluxo Pulsátil , Doadores de Tecidos , Velocidade do Fluxo Sanguíneo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA