Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Crit Rev Anal Chem ; 53(6): 1133-1173, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35001755

RESUMO

Flavonoids are bioactive polyphenolic compounds, widespread in the plant kingdom. Flavonoids possess broad-spectrum pharmacological effects due to their antioxidant, anti-tumor, anti-neoplastic, anti-mutagenic, anti-microbial, anti-inflammatory, anti-allergic, immunomodulatory, and vasodilatory properties. Care must be taken, since excessive consumption of flavonoids may have adverse effects. Therefore, proper identification, quantification and quality evaluations of flavonoids in edible samples are necessary. Electroanalytical approaches have gained much interest for the analysis of redox behavior and quantification of different flavonoids. Compared to various conventional methods, electrochemical techniques for the analysis of flavonoids offer advantages of high sensitivity, selectivity, low cost, simplicity, biocompatibility, easy on-site evaluation, high accuracy, reproducibility, wide linearity of detection, and low detection limits. This review article focuses on the developments in electrochemical sensing of different flavonoids with emphasis on electrode modification strategies to boost the electrocatalytic activity and analytical efficiency.


Assuntos
Antioxidantes , Flavonoides , Flavonoides/análise , Flavonoides/química , Flavonoides/farmacologia , Reprodutibilidade dos Testes , Antioxidantes/análise , Técnicas Eletroquímicas/métodos , Plantas/química
2.
Chemosphere ; 307(Pt 1): 135759, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35870606

RESUMO

Enzymes with their environment-friendly nature and versatility have become highly important 'green tools' with a wide range of applications. Enzyme immobilization has further increased the utility and efficiency of these enzymes by improving their stability, reusability, and recyclability. Biomass-derived matrices when used for enzyme immobilization offer a sustainable solution to environmental pollution and fuel depletion at low costs. Biochar and other biomass-derived carbon materials obtained are suitable for the immobilization of enzymes through different immobilization strategies. Environmental pollution has become an utmost topic of research interest due to an ever-increasing trend being observed in anthropogenic activities. This has widely contributed to the release of various toxic effluents into the environment in their native or metabolized forms. Therefore, more focus is being directed toward the utilization of immobilized enzymes in the bioremediation of water and soil, biofuel production, and other environmental applications. In this review, up-to-date literature concerning the immobilization and potential uses of enzymes immobilized on biomass-derived carbon materials has been presented.


Assuntos
Biocombustíveis , Enzimas Imobilizadas , Biomassa , Carbono , Enzimas Imobilizadas/metabolismo , Solo , Água
3.
Adv Colloid Interface Sci ; 297: 102542, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34655931

RESUMO

Enzymes have been incorporated into a wide variety of fields and industries as they catalyze many biochemical and chemical reactions. The immobilization of enzymes on carbon nanotubes (CNTs) for generating nano biocatalysts with high stability and reusability is gaining great attention among researchers. Functionalized CNTs act as excellent support for effective enzyme immobilization. Depending on the application, the enzymes can be tailored using the various surface functionalization techniques on the CNTs to extricate the desirable characteristics. Aiming at the preparation of efficient, stable, and recyclable nanobiocatalysts, this review provides an overview of the methods developed to immobilize the various enzymes. Various applications of carbon nanotube-based biocatalysts in water purification, bioremediation, biosensors, and biofuel cells have been comprehensively reviewed.

4.
RSC Adv ; 11(60): 37877-37885, 2021 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-35498093

RESUMO

Electrochemically deposited ZnO nanoparticles on a pencil graphite electrode (PGE) coated with graphene generate a noteworthy conductive and selective electrochemical sensing electrode for the estimation of cortisol. Electrochemical techniques such as cyclic voltammetry (CV) analysis and electrochemical impedance spectroscopic (EIS) tests were adopted to analyze and understand the nature of the modified sensor. Surface morphological analysis was done using various spectroscopic and microscopic techniques like X-ray photoelectron spectroscopy (XPS), transmission electron microscopy (TEM), and scanning electron microscopy (SEM). Structural characterization was conducted by X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR). The effect of scan rate, concentration, and cycle numbers was optimized and reported. Differential pulse voltammetric (DPV) analysis reveals that the linear range for the detection of cortisol is 5 × 10-10M - 115 × 10-10 M with a very low-level limit of detection value (0.15 nM). The demonstrated methodology has been excellently functional for the determination of salivary cortisol non-enzymatically at low-level concentration with enhanced selectivity despite the presence of interfering substances.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA