Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Assunto principal
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Colloid Interface Sci ; 652(Pt A): 705-717, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-37524621

RESUMO

The development of thin and flexible films that possess both electromagnetic interference (EMI) shielding and thermal management capabilities has always been an intriguing pursuit, but itisnevertheless a crucialproblemtoaddress. Inspired by the deformability of liquid metal (LM) and film forming capacity of MXene, here we present a series of ternary compositing films prepared via cellulose nanofiber (CNF) assisted vacuum filtration technology. Originating from the highly conductive LM/MXene network, the MLMC film presents a maximum EMI shielding effectiness (EMI SE) of 78 dB at a tiny thickness of 45 µm, together with a high specific EMI SE of 3046 dB mm-1. Meanwhile, these compositing films also deliver excellent flexibility and mechanical reliability, showing no obvious decline in EMI shielding performance even after 1000 bending and 500 folding cycles, respectively. Moreover, notable anisotropic thermal conductive property was successfully achieved, allowing for a highly desirable in-plane thermal conductivity of 7.8 W m-1 K-1. This accomplishment also yielded an exceptional electro-thermal conversion capacity, enabling efficient low-voltage (3 V) heating capabilities. These captivating features are expected to greatly drive the widespread adoption of LM-based films in future flexible electronic and wearable technologies.

2.
Ther Adv Respir Dis ; 16: 17534666211070134, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35114864

RESUMO

Increased cough sensitivity is an important mechanism of chronic cough, and the evaluation of cough sensitivity helps understand the mechanism of cough and explore better methods to reduce cough. Evaluation methods may be direct or indirect. Direct methods include mechanical stimulation and chemical stimulation, and indirect methods include laryngeal reflex test, questionnaires, and brain functional magnetic resonance imaging (fMRI). Chemical stimulation is the most common method, while the capsaicin cough challenge test is proven and widely used. In this article, we will compare evaluation methods and explore influencing factors of cough sensitivity.


Assuntos
Tosse , Reflexo , Capsaicina , Tosse/diagnóstico , Tosse/etiologia , Humanos , Reflexo/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA