Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Br J Ophthalmol ; 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38408856

RESUMO

BACKGROUND: Intraocular pressure (IOP) monitoring in glaucoma management is evolving with novel devices. We investigated the reproducibility of 24 hour profiles on two consecutive days and after 30 days of self-measurements via telemetric IOP monitoring. METHODS: Seven primary patients with open-angle glaucoma previously implanted with a telemetric IOP sensor in one eye underwent automatic measurements throughout 24 hours on two consecutive days ('day 1' and 'day 2'). Patients wore an antenna adjacent to the study eye connected to a reader device to record IOP every 5 min. Also, self-measurements in six of seven patients were collected for a period of 30 days. Analysis included calculation of hourly averages to correlate time-pairs of day 1 versus day 2 and the self-measurements vers day 2. RESULTS: The number of IOP measurements per patient ranged between 151 and 268 on day 1, 175 and 268 on day 2 and 19 and 1236 during 30 days of self-measurements. IOP time-pairs of automatic measurements on day 1 and day 2 were significantly correlated at the group level (R=0.83, p<0.001) and in four individual patients (1, 2, 6 and 7). IOP time-pairs of self-measurements and day 2 were significantly correlated at the group level (R=0.4, p<0.001) and in four individual patients (2, 5, 6 and 7). CONCLUSIONS: Twenty-four hour automatic measurements of IOP are correlated on consecutive days and, though to a lesser degree, with self-measurements. Therefore a virtual 24-hour IOP curve might be constructed from self-measurements. Both options provide an alternative to frequent in-office IOP measurements.

2.
Indian J Ophthalmol ; 72(4): 533-537, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38099366

RESUMO

PURPOSE: To evaluate the factors affecting corneal deformation amplitude (DA) measured using Corvis ST in eyes with open-angle glaucoma. METHODS: This prospective, longitudinal study included 48 eyes with open-angle glaucoma who required additional intraocular pressure (IOP)-lowering drops. All eyes underwent a complete eye examination at baseline, including a Corvis ST, which was repeated 4-8 weeks after the change in therapy. Factors affecting the corneal biomechanics, namely the DA, were determined using mixed effect models. RESULTS: The mean age of the cohort was 65.0 ± 7.9 years. The mean IOP reduced from 23.4 ± 5.4 mmHg to 17.9 ± 5 mmHg after the change in glaucoma treatment ( P < 0.001). The DA increased from 0.89 ± 0.16 mm to 1.00 ± 0.13 mm after IOP reduction ( P < 0.001). On mixed effect model analysis, IOP (-0.02 ± 0.001, P < 0.001) and corneal pachymetry (-0.0003 ± 0.0001, P = 0.02) affected the change in the DA. CONCLUSION: IOP and corneal pachymetry affect the DA and must be accounted for when using Corvis ST to evaluate corneal biomechanics in glaucoma.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Humanos , Pessoa de Meia-Idade , Idoso , Glaucoma de Ângulo Aberto/diagnóstico , Estudos Prospectivos , Estudos Longitudinais , Córnea , Pressão Intraocular , Tonometria Ocular , Paquimetria Corneana , Fenômenos Biomecânicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA