Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Am J Physiol Heart Circ Physiol ; 279(6): H2641-8, 2000 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11087216

RESUMO

To verify the interaction between coronary pressure (CP) and blood flow (CBF) control, we studied nine candidates for angioplasty of an isolated lesion of the left anterior descending coronary artery [i.e. , percutaneous transluminal coronary angioplasty (PTCA)]. CBF (i.e., flow velocity x coronary cross-sectional area at the Doppler tip) and CP were monitored during washout of 2-5 mCi of (133)Xe after bolus injection into the left main artery before and after PTCA. Xe mean transit time (MTT) was calculated as the area under the time-activity curve, acquired by a gamma camera, divided by the dose obtained from a model fit of the Xe curve in the anterior wall. CBF response to intracoronary adenosine (2 mg) was also assessed. PTCA increased baseline CBF (from 14.5 +/- 9.4 to 20 +/- 8 ml/min, P < 0.01), coronary flow reserve (from 1.52 +/- 0.24 to 2.33 +/- 0.8, P < 0.01), and CP (from 64 +/- 9 to 100 +/- 10 mmHg, P < 0.05). MTT decreased from 89 +/- 32 to 70 +/- 19 s (P < 0.05) after PTCA; however, MTT and CBF changes were not correlated (r = -0.09, not significant). Inasmuch as MTT is the ratio of distribution volume to CBF, MTT x CBF was used as an index of perfused myocardial volume. Volume increased after PTCA from 23 +/- 18 to 56 +/- 30 ml. A direct correlation was observed between the percent increase in distal CP and percent increase in perfused volume (r = 0.91, P < 0.01). Thus low CP was not associated with exhaustion of flow reserve but, rather, with reduction of perfused myocardial volume. These data suggest that, in the presence of a severe coronary stenosis, derecruitment of vascular units occurs that is proportional to the decrease in driving pressure. Residual perfused units maintain a vasomotor tone, thus explaining the paradoxical persistence of coronary reserve.


Assuntos
Angioplastia Coronária com Balão , Pressão Sanguínea/fisiologia , Circulação Coronária/fisiologia , Doença das Coronárias/fisiopatologia , Doença das Coronárias/terapia , Aorta/fisiologia , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/fisiopatologia , Constrição Patológica/terapia , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Ecocardiografia Doppler , Homeostase/fisiologia , Humanos , Microcirculação/fisiologia , Pessoa de Meia-Idade , Músculo Liso Vascular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA