Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Breast ; 50: 11-18, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31958661

RESUMO

BACKGROUND: Patients with breast cancer (BC) show strong interest in complementary and alternative medicine (CAM), particularly for adverse effects of adjuvant endocrine treatment - e.g., with letrozole. Letrozole often induces myalgia/limb pain and arthralgia, with potential noncompliance and treatment termination. This analysis investigated whether CAM before aromatase inhibitor (AI) therapy is associated with pain development and the intensity of AI-induced musculoskeletal syndrome (AIMSS) during the first year of treatment. PATIENTS AND METHODS: The multicenter phase IV PreFace study evaluated letrozole therapy in postmenopausal, hormone receptor-positive patients with early BC. Patients were asked about CAM use before, 6 months after, and 12 months after treatment started. They recorded pain every month for 1 year in a diary including questions about pain and numeric pain rating scales. Data were analyzed for patients who provided pain information for all time points. RESULTS: Of 1396 patients included, 901 (64.5%) had used CAM before AI treatment. Throughout the observation period, patients with CAM before AI treatment had higher pain values, for both myalgia/limb pain and arthralgia, than non-users. Pain increased significantly in both groups over time, with the largest increase during the first 6 months. No significant difference of pain increase was noted regarding CAM use. CONCLUSIONS: CAM use does not prevent or improve the development of AIMSS. Pain intensity was generally greater in the CAM group. Therefore, because of the risk of non-compliance and treatment discontinuation due to the development of higher pain levels, special attention must be paid to patient education and aftercare in these patients.


Assuntos
Inibidores da Aromatase/efeitos adversos , Neoplasias da Mama/tratamento farmacológico , Terapias Complementares , Letrozol/efeitos adversos , Dor Musculoesquelética/induzido quimicamente , Idoso , Artralgia/induzido quimicamente , Feminino , Alemanha/epidemiologia , Humanos , Pessoa de Meia-Idade , Mialgia/induzido quimicamente , Pós-Menopausa
2.
J Viral Hepat ; 25(6): 752-758, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29377436

RESUMO

A steep rise in Hepatitis E diagnoses is currently being observed in Germany and other European countries. The objective of this study was (i) to assess whether this trend mirrors an increase in infection pressure or is caused by increased attention and testing and (ii) estimate individual and population-based Hepatitis E Virus (HEV) seroconversion and seroreversion rates for Germany. We measured anti-HEV IgG prevalence in 10 407 adults participating in two linked, population-representative serosurveys (total n = 12 971) conducted in 1998 and 2010. In this period, we found a moderate but statistically significant decline of overall anti-HEV IgG prevalence from 18.6% to 15.3%. At both time points, seroprevalence increased with age and peaked in persons born between 1935 and 1959 suggesting a past period of increased infection pressure. Paired samples of individuals participating in 1998 and 2010 (n = 2564) revealed respective seroconversion and seroreversion rates of 6.2% and 22.6% among seronegative and seropositive individuals during 12 years, or 5.2 and 2.9 per 1000 inhabitants per year. This corresponds to a total of 417 242 [95%CI: 344 363-495 971] new seroconversions per year in the German population. While anti-HEV seroprevalence has decreased in the last decade, infection pressure and seroincidence remains high in Germany. Continuously rising numbers of Hepatitis E diagnoses in Europe are likely due to an increased awareness of clinicians and indicate that still there is a gap between incident and diagnosed cases. Studies on the true burden of the disease, specific risk factors and sources of autochthonous infections as well as targeted prevention measures are urgently needed.


Assuntos
Vírus da Hepatite E/imunologia , Hepatite E/epidemiologia , Adolescente , Adulto , Idoso , Betacoronavirus 1 , Feminino , Alemanha/epidemiologia , Anticorpos Anti-Hepatite/sangue , Humanos , Imunoglobulina G/sangue , Incidência , Masculino , Pessoa de Meia-Idade , Soroconversão , Estudos Soroepidemiológicos , Adulto Jovem
3.
Ann Oncol ; 29(1): 186-192, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-29045642

RESUMO

Background: Patients' compliance and persistence with endocrine treatment has a significant effect on the prognosis in early breast cancer (EBC). The purpose of this analysis was to identify possible reasons for non-persistence, defined as premature cessation of therapy, on the basis of patient and tumor characteristics in individuals receiving adjuvant treatment with letrozole. Patients and methods: The EvAluate-TM study is a prospective, multicenter, noninterventional study in which treatment with the aromatase inhibitor letrozole was evaluated in postmenopausal women with hormone receptor-positive EBC in the early therapy phase. Treatment persistence was evaluated at two pre-specified study visits after 6 and 12 months. As a measure of early therapy persistence the time from the start to the end of treatment (TTEOT) was analyzed. Cox regression analyses were carried out to identify patient characteristics and tumor characteristics predicting TTEOT. Results: Out of the total population of 3941 patients with EBC, 540 (13.7%) events involving treatment cessation unrelated to disease progression were observed. This was due to drug-related toxicity in the majority of cases (73.5%). Persistence rates were 92.2%, 86.9%, and 86.3% after 6, 12, and 15 months, respectively. The main factors influencing premature treatment discontinuation were older age [hazard ratio (HR) 1.02/year], comorbidities (HR 1.06 per comorbidity), low body mass index, and lower tumor grade (HR 0.85 per grade unit). Conclusion: These results support the view that older, multimorbid patients with low tumor grade and low body mass index are at the greatest risk for treatment discontinuation and might benefit from compliance and support programs.


Assuntos
Neoplasias da Mama/tratamento farmacológico , Letrozol/administração & dosagem , Adesão à Medicação , Idoso , Antineoplásicos/administração & dosagem , Inibidores da Aromatase/administração & dosagem , Neoplasias da Mama/patologia , Neoplasias da Mama/psicologia , Quimioterapia Adjuvante , Feminino , Humanos , Pessoa de Meia-Idade , Pós-Menopausa , Estudos Prospectivos
4.
Geburtshilfe Frauenheilkd ; 77(2): 169-175, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28331239

RESUMO

Introduction The placement of intramammary marker clips has proven to be helpful for tumor localization in patients undergoing neoadjuvant chemotherapy and breast-conserving surgery. The purpose of our study was to investigate the feasibility of using a clip marker system for breast cancer localization and its influence on the imaging assessment of treatment responses after neoadjuvant chemotherapy. Patients and Methods Between March and June 2015, a total of 25 patients (n = 25), with a suspicion of invasive breast cancer with diameters of at least 2 cm (cT2), underwent preoperative sonographically guided core needle biopsy using a single-use breast biopsy system (HistoCore™) and intramammary clip marking using a directly adapted clip system based on the established O-Twist Marker™, before their scheduled preoperative neoadjuvant chemotherapy. Localization of the intramammary marker clip was controlled by sonography and digital breast tomosynthesis. Results Sonography detected no dislocation of intrammammary marker clips in 20 of 25 patients (80 %), while digital breast tomosynthesis showed accurate placement without dislocation in 24 patients (96 %) (p < 0.05). There was no evidence of significant clip migration during preoperative follow-up imaging after neoadjuvant chemotherapy. No complication related to the clip marking was noted and there was no difficulty in evaluating the treatment response to neoadjuvant chemotherapy. Among the breast-conserving surgeries performed, no cases were identified in which intraoperative loss of the marker clip had occurred. Conclusion Our study underscores the importance of intramammary marking clip systems before neoadjuvant chemotherapy. Placement of marker clips is advised to facilitate accurate tumor bed localization. With regard to digital breast tomosynthesis, its development continues to improve the quality of diagnostics and the therapy of breast cancer particularly for small breast cancer tumors or in neoadjuvant chemotherapy setting.

5.
J Viral Hepat ; 24(1): 75-79, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27699946

RESUMO

Hepatitis E virus (HEV) is highly endemic in industrialized countries, but there is a lack of knowledge on individual and overall antibody concentration dynamics. The aim of this study was to characterize longitudinal concentration changes of anti-HEV immunoglobulin G (anti-HEV IgG) by enzyme immunoassay (EIA). In total, 199 serum samples collected from 45 subjects over 18 years were analysed. A wide range of anti-HEV IgG levels was found. Overall, anti-HEV IgG significantly decreased after an observation period of at least 5 years. One negative seroconversion was observed. Four individual profiles suggested single and even multiple HEV reinfections despite pre-existing HEV antibodies.


Assuntos
Anticorpos Anti-Hepatite/sangue , Hepatite E/imunologia , Adulto , Idoso , Feminino , Humanos , Imunoglobulina G/sangue , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Adulto Jovem
6.
Geburtshilfe Frauenheilkd ; 76(1): 59-64, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26855442

RESUMO

Introduction: Stereotactically-guided core needle biopsies (CNB) of breast tumours allow histological examination of the tumour without surgery. Touch imprint cytology (TIC) of CNB promises to be useful in providing same-day diagnosis for counselling purposes and for planning future surgery. Having addressed the issue of accuracy of immediate microscopic evaluation of TIC, we wanted to re-examine the usefulness of this procedure in light of the present health care climate of cost containment by incorporating the surgical 15-year follow-up data and outcome. Patients and Methods: From January until December 1996 we performed TIC in core needle biopsies of 173 breast tumours in 169 patients, consisting of 122 malignant and 51 benign tumours. Histology of core needle biopsies was proven by surgical histology in all malignant and in 5 benign tumours. Surgical breast biopsy was not performed in 46 patients with 46 benign lesions, as the histological result from the core needle biopsy and the result of the TIC were in agreement with the suspected diagnosis from the complementary breast diagnostics. A 15-year follow-up of these patients followed in 2013 and follow-up data was collected from 40 women. Results: In the 15-year follow-up of the 40 benign lesions primarily confirmed using CNB and TIC, a diagnostic sensitivity, specificity, positive and negative predictive value and accuracy of 100 % was found. Conclusion: TIC and stereotactically guided CNB showed excellent long-term follow-up in patients with benign breast lesions. The use of TIC to complement CNB can therefore provide immediate cytological diagnosis of breast lesions.

7.
Geburtshilfe Frauenheilkd ; 75(6): 588-596, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26166840

RESUMO

Introduction: Use of hormone therapy (HT) has declined dramatically in recent years. Some studies have reported that HT use before a diagnosis of breast cancer (BC) may be a prognostic factor in postmenopausal patients. This study aimed to examine the prognostic relevance of HT use before BC diagnosis. Methods: Four BC cohort studies in Germany were pooled, and 4492 postmenopausal patients with HT use data were identified. Patient data and tumor characteristics were compared between users and nonusers, along with overall survival (OS), distant metastasis-free survival (DMFS), and local recurrence-free survival (LRFS). Cox proportional hazards models were stratified by study center and adjusted for age at diagnosis, tumor stage, grading, nodal status, and hormone receptors. Results: Women with HT use before the diagnosis of BC were more likely to have a lower tumor stage, to be estrogen receptor-negative, and to have a lower grading. With regard to prognosis there were effects seen for OS, DMFS and LRFS, specifically in the subgroup of women with a positive hormone receptor. In these subgroups, BC patients had a better prognosis with previous HT use. Conclusions: HT use before a diagnosis of BC is associated with a more favorable prognosis in women with a positive hormone receptor status. It may be recommended that the prognostic factor HT should be documented and analyzed as a confounder for prognosis in studies of postmenopausal hormone-responsive breast cancers.

9.
Geburtshilfe Frauenheilkd ; 75(1): 72-76, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25684789

RESUMO

Introduction: This study aimed to compare the accuracy of sonography versus digital breast tomosynthesis to locate intramammary marker clips placed under ultrasound guidance. Patients and Methods: Fifty patients with suspicion of breast cancer (lesion diameter less than 2 cm [cT1]) had ultrasound-guided core needle biopsy with placement of a marker clip in the center of the tumor. Intramammary marker clips were subsequently located with both sonography and digital breast tomosynthesis. Results: Sonography detected no dislocation of intrammammary marker clips in 42 of 50 patients (84 %); dislocation was reported in 8 patients (16 %) with a maximum dislocation of 7 mm along the x-, y- or z-axis. Digital breast tomosynthesis showed accurate placement without dislocation of the intramammary marker clip in 48 patients (96 %); 2 patients (4 %) had a maximum clip dislocation of 3 mm along the x-, y- or z-axis (p < 0.05). Conclusion: The use of digital breast tomosynthesis could improve the accuracy when locating intramammary marker clips compared to sonography and could, in future, be used to complement or even completely replace sonography.

10.
Geburtshilfe Frauenheilkd ; 74(8): 743-751, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25221342

RESUMO

Aim: Certification of breast centers helps improve the quality of care but requires additional resources, particularly for documentation. There are currently no published data on the actual staff costs and financial resources required for such documentation. The aim of this study was to determine the time and resources required to document a patient with primary breast cancer from diagnosis to the end of follow-up, to establish a database for future strategic decisions. Material and Methods: All diagnostic and therapeutic procedures of patients with primary breast cancer were recorded at the University Breast Center of Franconia. All time points for documentation were evaluated using structured interviews. The times required to document a representative number of patients were determined and combined with the staff costs of the different professional groups, to calculate the financial resources required for documentation. Results: A total of 494 time points for documentation were identified. The study also identified 21 departments and 20 different professional groups involved in the documentation. The majority (54 %) of documentation was done by physicians. 62 % of all documentation involved outpatients. The results of different scenarios for the diagnosis, therapy and follow-up of breast cancer patients in a certified breast center showed that the time required for documentation can be as much as 105 hours, costing € 4135. Conclusion: This analysis shows the substantial staffing and financial costs required for documentation in certified centers. A multi-center study will be carried out to compare the costs for certified breast centers of varying sizes with the costs of non-certified care facilities.

11.
Radiologe ; 54(3): 217-23, 2014 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-24570108

RESUMO

Mammography is the central diagnostic method for clinical diagnostics of breast cancer and the breast cancer screening program. In the clinical routine complementary methods, such as ultrasound, tomosynthesis and optional magnetic resonance imaging (MRI) are already combined for the diagnostic procedure. Future developments will utilize investigative procedures either as a hybrid (combination of several different imaging modalities in one instrument) or as a fusion method (the technical fusion of two or more of these methods) to implement fusion imaging into diagnostic algorithms. For screening there are reasonable hypotheses to aim for studies that individualize the diagnostic process within the screening procedure. Individual breast cancer risk prediction and individualized knowledge about sensitivity and specificity for certain diagnostic methods could be tested. The clinical implementation of these algorithms is not yet in sight.


Assuntos
Neoplasias da Mama/diagnóstico , Detecção Precoce de Câncer/tendências , Previsões , Mamografia/tendências , Imagem Molecular/tendências , Imagem Multimodal/tendências , Técnica de Subtração/tendências , Algoritmos , Feminino , Humanos , Aumento da Imagem/métodos
13.
Geburtshilfe Frauenheilkd ; 74(12): 1137-1143, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25568468

RESUMO

Introduction: The EvaluateTM study (Evaluation of therapy management and patient compliance in postmenopausal hormone receptor-positive breast cancer patients receiving letrozole treatment) is a prospective, non-interventional study for the assessment of therapy management and compliance in the routine care of postmenopausal women with invasive hormone receptor-positive breast cancer receiving letrozole. The parameters for inclusion in the study are presented and discussed here. Material and Methods: Between January 2008 and December 2009 a total of 5045 patients in 310 study centers were recruited to the EvaluateTM study. Inclusion criteria were hormone receptor-positive breast cancer and adjuvant treatment or metastasis. 373 patients were excluded from the analysis for various reasons. Results: A total of 4420 patients receiving adjuvant treatment and 252 patients with metastasis receiving palliative treatment were included in the study. For 4181 patients receiving adjuvant treatment, treatment with the aromatase inhibitor letrozole commenced immediately after surgery (upfront). Two hundred patients had initially received tamoxifen and started aromatase inhibitor treatment with letrozole at 1-5 years after diagnosis (switch), und 39 patients only commenced letrozole treatment 5-10 years after diagnosis (extended endocrine therapy). Patient and tumor characteristics were within expected ranges, as were comorbidities and concurrent medication. Conclusion: The data from the EvaluateTM study will offer a good overview of therapy management in the routine care of postmenopausal women with hormone receptor-positive breast cancer. Planned analyses will look at therapy compliance and patient satisfaction with how information is conveyed and the contents of the conveyed information.

15.
Ultraschall Med ; 35(1): 33-7, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24327473

RESUMO

INTRODUCTION: The potential of sonography in the examination of lung tissue is extremely limited by the air-filled alveoles of the lung. Only in special circumstances like pleural adhesion lesions, atelectasis or pneumonia can lung tissue be visualized by B-mode sonography. Real-time elastography was primarily applied to detect and visualize pulmonary lesions. METHODS AND PATIENTS: 8 patients with a total of 18 histologically proven metastases of the lung were included. All pulmonary lesions were detected by computed tomography. Sonographic examination was performed with a 7.5 MHz linear transducer (Acuson Antares premium edition, Siemens, Erlangen, Germany), including B-mode and real-time elastography (RTE). The mean distance between pleura and the lesions ranged from 0 to 2.5 cm. Two lesions were located in the upper right lobe, eleven lesions in the lower right and five in the lower left lobe. RESULTS: RTE was able to detect and visualize all 18 pulmonary lesions in contrast to B-mode. The size and distance of the lesions from the pleura correlated with the CT findings. CONCLUSION: In contrast to B-mode sonography, RTE is able to detect and visualize peripheral, non-pleural adherent pulmonary lesions.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Leiomiossarcoma/diagnóstico por imagem , Leiomiossarcoma/secundário , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/secundário , Neoplasias Ovarianas/diagnóstico por imagem , Neoplasias Uterinas/diagnóstico por imagem , Idoso , Neoplasias da Mama/patologia , Técnicas de Imagem por Elasticidade/instrumentação , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/instrumentação , Interpretação de Imagem Assistida por Computador/métodos , Leiomiossarcoma/patologia , Pulmão/diagnóstico por imagem , Pulmão/patologia , Neoplasias Pulmonares/patologia , Pessoa de Meia-Idade , Neoplasias Ovarianas/patologia , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Transdutores , Carga Tumoral , Neoplasias Uterinas/patologia
16.
Geburtshilfe Frauenheilkd ; 73(11): 1135-1138, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24771900

RESUMO

Introduction: A newly adapted clip system for intramammary marking during ultrasound-guided core needle biopsy for suspicion of breast cancer is described and evaluated here. Material and Method: Fifty patients with suspicion of breast cancer (cT2) had ultrasound-guided core needle biopsy using a newly adapted clip marker system (HistoCore™ and O-Twist Marker™). Subsequently, ultrasound follow-up and tomosynthesis scans were done to determine the location of the marker clips. Results: No dislocation of the marker clip was detected on ultrasound in 45 of 50 patients (90 %), and 5 patients (10 %) had a maximum dislocation of 5 mm along the x-, y- or z-axis. Tomosynthesis scans demonstrated precise placement without dislocation of the clip markers in 48 patients (96 %); 2 patients (4 %) had a maximum dislocation of 3 mm along the x-, y- or z-axis. Conclusion: The newly developed clip marker system, a combination of a single-use breast biopsy needle and a precise, length-adapted intramammary marker clip, represents a further improvement in oncological therapy. This is of particular importance for patients requiring subsequent neoadjuvant chemotherapy, as in cases with complete tumour remission, there is no target point for preoperative, ultrasound-guided wire marking.

17.
Geburtshilfe Frauenheilkd ; 73(12): 1228-1235, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24771903

RESUMO

Several advancements over the last decade have triggered the developments in the field of breast cancer risk research. One of them is the availability of the human genome sequence along with cheap genotyping possibilities. Another is the globalization of research, which has led to the growth of research collaboration into large international consortia that facilitate the pooling of clinical and genotype data of hundreds of thousands of patients and healthy control individuals. This review concerns with the recent developments in breast cancer risk research and focuses on the discovery of new genetic breast cancer risk factors and their meaning in the context of established non-genetic risk factors. Finally the clinical application is highly dependent on the accuracy of breast cancer risk prediction models, not only for all breast cancer patients, but also for molecular subtypes, preferably for those which are associated with an unfavorable prognosis. Recently risk prediction incorporates all possible risk factors, which include epidemiological risk factors, mammographic density and genetic risk factors.

18.
Geburtshilfe Frauenheilkd ; 73(2): 136-141, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24771910

RESUMO

Aim: Nodal status remains one of the most important prognostic factors in breast cancer. The cellular and molecular reasons for the spread of tumor cells to the lymph nodes are not well understood and there are only few predictors in addition to tumor size and multifocality that give an insight into additional mechanisms of lymphatic spread. Aim of our study was therefore to investigate whether breast characteristics such as mammographic density (MD) add to the predictive value of the presence of lymph node metastases in patients with primary breast cancer. Methods: In this retrospective study we analyzed primary, metastasis-free breast cancer patients from one breast center for whom data on MD and staging information were available. A total of 1831 patients were included into this study. MD was assessed as percentage MD (PMD) using a semiautomated method and two readers for every patient. Multiple logistic regression analyses with nodal status as outcome were used to investigate the predictive value of PMD in addition to age, tumor size, Ki-67, estrogen receptor (ER), progesterone receptor (PR), grading, histology, and multi-focality. Results: Multifocality, tumor size, Ki-67 and grading were relevant predictors for nodal status. Adding PMD to a prediction model which included these factors did not significantly improve the prediction of nodal status (p = 0.24, likelihood ratio test). Conclusion: Nodal status could be predicted quite well with the factors multifocality, tumor size, Ki-67 and grading. PMD does not seem to play a role in the lymphatic spread of tumor cells. It could be concluded that the amount of extracellular matrix and stromal cell content of the breast which is reflected by MD does not influence the probability of malignant breast cells spreading from the primary tumor to the lymph nodes.

19.
Geburtshilfe Frauenheilkd ; 73(5): 422-427, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-24771921

RESUMO

Aim: This prospective clinical study aimed to evaluate whether it would be possible to reduce the rate of re-excisions using CMOS technology, a specimen radiography system (SRS) or digital breast tomosynthesis (DBT) compared to a conventional full field digital mammography (FFDM) system. Material and Method: Between 12/2012 and 2/2013 50 patients were diagnosed with invasive breast cancer (BI-RADS™ 5). After histological verification, all patients underwent breast-conserving therapy with intraoperative imaging using 4 different systems and differing magnifications: 1. Inspiration™ (Siemens, Erlangen, Germany), amorphous selenium, tungsten source, focus 0.1 mm, resolution 85 µm pixel pitch, 8 lp/mm; 2. BioVision™ (Bioptics, Tucson, AZ, USA), CMOS technology, photodiode array, flat panel, tungsten source, focus 0.05, resolution 50 µm pixel pitch, 12 lp/mm; 3. the Trident™ specimen radiography system (SRS) (Hologic, Bedford, MA, USA), amorphous selenium, tungsten source, focus 0.05, resolution 70 µm pixel pitch, 7.1 lp/mm; 4. tomosynthesis (Siemens, Erlangen, Germany), amorphous selenium, tungsten source, focus 0.1 mm, resolution 85 µm pixel pitch, 8 lp/mm, angular range 50 degrees, 25 projections, scan time > 20 s, geometry: uniform scanning, reconstruction: filtered back projection. The 600 radiographs were prospectively shown to 3 radiologists. Results: Of the 50 patients with histologically proven breast cancer (BI-RADS™ 6), 39 patients required no further surgical therapy (re-excision) after breast-conserving surgery. A retrospective analysis (n = 11) showed a significant (p < 0.05) increase of sensitivity with the BioVision™, the Trident™ and tomosynthesis compared to the Inspiration™ at a magnification of 1.0 : 2.0 or 1.0 : 1.0 (tomosynthesis) (2.6, 3.3 or 3.6 %), i.e. re-excision would not have been necessary in 2, 3 or 4 patients, respectively, compared to findings obtained with a standard magnification of 1.0 : 1.0. Conclusion: The sensitivity of the BioVision™, the Trident™ and tomosynthesis was significantly (p < 0.05) higher and the rate of re-excisions was reduced compared to FFDM using a conventional detector at a magnification of 2.0 but without zooming.

20.
Eur J Surg Oncol ; 38(1): 44-51, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22032911

RESUMO

BACKGROUND: Re-operations after breast conserving surgery (BCS) are necessary, when specimen margins are not free of breast cancer cells. This study explored the accuracy of preoperative tumour size assessment and its influence on the rate of re-excisions and mastectomies. METHODS: The study included 1591 patients with invasive breast cancer, who were planned for BCS. Patient, staging and tumor characteristics were evaluated concerning their influence on re-excision and mastectomy rates. Patient and tumor characteristics comprised histopathological tumour size, HER2 status, multifocality, in situ component, grading (G), nodal status and hormone receptor (HR) status. Staging characteristics included deviation from pathological tumour size as measured by clinical examination, sonography and mammography. RESULTS: In 1316 patients (83%) sufficient treatment was possible with one operation. 275 patients (17%) had to undergo at least one further surgery as a result of positive specimen margins. In 138 patients (9%) mastectomy was ultimately necessary. In patients with a positive HER2 status, a larger tumour size, underestimation by ultrasound, an in situ component and multifocality, the risk for a re-operation was about doubled. Tumour size deviation in the mammogram or the clinical tumour size assessment did not have significant influence to the re-excision rates. CONCLUSION: Tumour size and accurate presurgical assessment of the tumour size itself are independent predictors for the need of a second surgery or even a mastectomy in patients for whom a primary BCS was planned.


Assuntos
Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Mamografia , Mastectomia Segmentar , Neoplasia Residual/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais/sangue , Neoplasias da Mama/diagnóstico por imagem , Estudos de Coortes , Feminino , Humanos , Mastectomia Radical Modificada , Pessoa de Meia-Idade , Gradação de Tumores , Estadiamento de Neoplasias , Valor Preditivo dos Testes , Período Pré-Operatório , Reoperação , Medição de Risco , Ultrassonografia Mamária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA