Resultados 1 - 20 de 509
Filtrar
1.
J Am Coll Cardiol ; 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38864538

RESUMO

BACKGROUND: The ADVENT randomized trial revealed no significant difference in 1-year freedom from atrial arrhythmias (AA) between thermal (RF/Cryo) and pulsed field ablation (PFA). However, recent studies indicate that the post-ablation AA burden is a better predictor of clinical outcomes than the dichotomous endpoint of 30-second AA recurrence. OBJECTIVES: To determine i) the impact of post-ablation AA burden on outcomes, and ii) the effect of ablation modality on AA burden. METHODS: In ADVENT, symptomatic drug-refractory paroxysmal AF (PAF) patients underwent PFA or thermal ablation. Post-ablation transtelephonic ECG monitor (TTM) recordings were collected weekly or for symptoms, and 72-hour Holters were at 6- and 12-months. AA burden was calculated from percentage AA on Holters and TTMs. Quality-of-life assessments were at baseline and 12-months. RESULTS: From 593 randomized patients (299 PFA, 294 thermal), using aggregate PFA/thermal data, an AA burden exceeding 0.1% was associated with a significantly reduced quality-of-life and an increase in clinical interventions: redo ablation, cardioversion and hospitalization. There were more patients with residual AA burden <0.1% with PFA than thermal ablation (OR 1.5, 95%CI: 1.0, 2.3; p=0.04). Evaluation of outcomes by baseline demographics revealed that patients with prior failed Class I/III AADs had less residual AA burden after PFA compared to thermal ablation (OR 2.5, 95%CI: 1.4, 4.3; p=0.002); patients receiving only Class II/IV AADs pre-ablation had no difference in AA burden between ablation groups. CONCLUSION: Compared to thermal ablation, PFA more often resulted in an AA burden less than the clinically-significant threshold of 0.1% burden.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38869507

RESUMO

BACKGROUND: Autonomic denervation is an ancillary phenomenon during thermal ablation of atrial fibrillation (AF), that may have synergistic effects on symptomatic improvement and long-term freedom from AF. Pulsed field ablation (PFA), a nonthermal ablation modality, was noninferior to thermal ablation in treating AF; however, PFA's relative myocardial selectivity may minimize autonomic effects. OBJECTIVES: This study sought to compare heart rate (HR) and heart rate variability (HRV) metrics as markers of autonomic function after ablation using PFA vs thermal ablation. METHODS: ADVENT (The FARAPULSE ADVENT PIVOTAL Trial PFA System vs SOC Ablation for Paroxysmal Atrial Fibrillation) was a randomized pivotal study comparing PFA (pentaspline catheter) with thermal ablation (radiofrequency [RF] or cryoballoon [CB]) for treating paroxysmal AF. Baseline HR was acquired from a pre-ablation 12-lead electrocardiogram, whereas follow-up HRs, as well as HRV (standard deviation of all normal to normal RR intervals, standard deviation of 5-minute average RR intervals) metrics, were derived from 72-hour Holter monitors at 6 and 12 months. RESULTS: This study included 379 paroxysmal AF patients undergoing PFA (n = 194) or thermal ablation (n = 185; n = 102 RF, n = 83 CB) completing 6- and 12-month Holter monitoring. Compared with PFA, thermal patients had significantly greater increases in HR from baseline to 6 months (ΔHR; 10.1 vs 5.9 beats/min; P = 0.02) and 12 months (ΔHR; 8.8 vs 5.2 beats/min; P = 0.03). This increase in HR at 6 and 12 months was similar between CB and RF (P = 0.94 and 0.83, respectively). HRV, both standard deviation of all normal to normal RR intervals and standard deviation of 5-minute average RR intervals, were significantly lower at both 6 and 12 months after thermal ablation compared with PFA (P < 0.01). CONCLUSIONS: PFA's effect on the autonomic nervous system was attenuated compared with thermal ablation. Whether this affects long-term freedom from AF or symptomatic bradycardia/pauses after AF ablation requires further study.

3.
Heart Rhythm ; 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38823667

RESUMO

BACKGROUND: Atrial fibrillation (AF) ablation carries the risk of silent cerebral event (SCE) and silent cerebral lesion (SCL). Though "silent," these may have long-term clinical implications and are challenging to study as post-procedural MRI is not standard-of-care. OBJECTIVE: The neurological assessment subgroup (NAS) of ADVENT compared cerebral effects of pulsed field ablation (PFA) to standard-of-care thermal ablation. METHODS: The NAS included consecutive randomized PFA and thermal ablation patients who received post-procedural brain MRI 12-48 hours post-ablation. Patients with apparent SCE or SCL findings underwent a modified Rankin Scale (mRS) assessment. MRI images were subsequently reviewed by a blinded Brain Imaging Core Laboratory. RESULTS: In total, 77 patients with paroxysmal AF were enrolled at 6 centers; 71 had analyzable scans (34 PFA; 37 thermal ablation). Through individual center review, 6 PFA and 4 thermal scans were identified as SCE/SCL positive, of which, 3 PFA and 0 thermal SCE/SCL findings were confirmed by a blinded core laboratory. MRI findings revealed one patient with 2-4mm SCEs, one patient with a 3mm SCE, and one patient with 2 SCLs (5.5mm and 11mm). All mRS and NIHSS scores were 0 prior to discharge and at 90-day follow-up. There were only two neurological safety events (1 TIA (PFA) and 1 stroke (thermal) in the ADVENT study, neither of which was part of the NAS. CONCLUSIONS: The ADVENT trial provides the first prospective, randomized data on the cerebral impact of PFA and thermal ablation of AF. Incidence of SCE/SCLs following ablation in the NAS was low.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38842972

RESUMO

BACKGROUND: Electrographic flow (EGF) mapping enables full spatiotemporal reconstruction of organized wavefront propagation to identify extrapulmonary vein sources of atrial fibrillation (AF). OBJECTIVES: FLOW-AF (A Randomized Controlled Study to Evaluate the Reliability of the Ablacon Electrographic FLOW [EGF] Algorithm Technology [Ablamap Software] to Identify AF Sources and Guide Ablation Therapy in Patients With Persistent Atrial Fibrillation) was multicenter, randomized controlled study of EGF mapping to: 1) stratify a nonparoxysmal AF population undergoing redo ablation; 2) guide ablation of these extrapulmonary vein AF sources; and 3) improve AF recurrence outcomes. METHODS: FLOW-AF enrolled persistent atrial fibrillation (PerAF)/long-standing PerAF patients undergoing redo ablation at 4 centers. One-minute EGF maps were recorded from standardized biatrial basket positions. Patients with source activity ≥26.5% were randomized 1:1 to PVI + EGF-guided ablation vs PVI only; patients without sources ≥26.5% threshold were not randomized. Follow-up and electrocardiographic monitoring occurred at 3, 6, and 12 months. RESULTS: We enrolled 85 patients (age 65.6 ± 9.3 years, 37% female, 24% long-standing PerAF). Thirty-four (40%) patients had no sources greater than threshold; at least 1 source greater than threshold was present in 46 (60%) (EGF-guided ablation, n = 22; control group, n = 26). Patients with sources were older (68.2 vs 62.6 years; P = 0.005) with higher CHA2DS2-VASc scores (2.8 vs 1.9; P = 0.001). The freedom from safety events was 97.2%, and 95% of EGF-identified sources were successfully ablated. In randomized patients, AF-free survival at 12 months was 68% for EGF-guided ablation vs 17% for the control group (P = 0.042); freedom from AF/atrial tachycardia/atrial flutter at 12 months was 51% vs 14% (P = 0.103), respectively. CONCLUSIONS: In nonparoxysmal AF patients undergoing redo ablation, EGF mapping identified AF sources in 60% of patients, and could be successfully ablated in 95%. Compared with PVI alone, PVI + source ablation improved AF-free survival by 51% on an absolute basis. (FLOW-AF: A Study to Evaluate the Ablacon Electrographic FLOW EGF Technology [A Randomized Controlled Study to Evaluate the Reliability of the Ablacon Electrographic FLOW (EGF) Algorithm Technology (Ablamap Software) to Identify AF Sources and Guide Ablation Therapy in Patients With Persistent Atrial Fibrillation]; NCT04473963).

5.
Artigo em Inglês | MEDLINE | ID: mdl-38852101

RESUMO

BACKGROUND: Hemolysis-related renal failure has been described after pulmonary vein isolation (PVI) with pulsed-field ablation (PFA). OBJECTIVES: This study sought to compare the potential for hemolysis during PVI with PFA vs radiofrequency ablation (RFA). METHODS: In consecutive patients, PVI was performed with PFA or RFA. Blood samples were drawn at baseline, immediately postablation, and 24 hours postablation. Using flow cytometry, the concentration of red blood cell microparticles (RBCµ) (fragments of damaged erythrocytes) in blood was assessed. Lactate dehydrogenase (LDH), haptoglobin, and indirect bilirubin were measured at baseline and 24 hours. RESULTS: Seventy patients (age: 64.7 ± 10.2 years; 47% women; 36 [51.4%] paroxysmal atrial fibrillation) were enrolled: 47 patients were in the PFA group (22 PVI-only and 36.4 ± 5.5 PFA applications; 25 PVI-plus, 67.3 ± 12.4 pulsed field energy applications), and 23 patients underwent RFA. Compared to baseline, the RBCµ concentration increased ∼12-fold postablation and returned to baseline by 24 hours in the PFA group (median: 70.8 [Q1-Q3: 51.8-102.5] vs 846.6 [Q1-Q3: 639.2-1,215.5] vs 59.3 [Q1-Q3: 42.9-86.5] RBCµ/µL, respectively; P < 0.001); this increase was greater with PVI-plus compared to PVI-only (P = 0.007). There was also a significant, albeit substantially smaller, periprocedural increase in RBCµ with RFA (77.7 [Q1-Q3: 39.2-92.0] vs 149.6 [Q1-Q3: 106.6-180.8] vs 89.0 [Q1-Q3: 61.2-123.4] RBCµ/µL, respectively; P < 0.001). At 24 hours with PFA, the concentration of LDH and indirect bilirubin increased, whereas haptoglobin decreased significantly (all P < 0.001). In contrast, with RFA, there were only smaller changes in LDH and haptoglobin concentrations (P = 0.03) and no change in bilirubin. CONCLUSIONS: PFA was associated with significant periprocedural hemolysis. With a number of 70 PFA lesions, the likelihood of significant renal injury is uncommon.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38845147

RESUMO

INTRODUCTION: Prior studies have indicated that the frequency of premature ventricular complexes (PVC) increases after catheter ablation for atrial fibrillation (AF). However, these studies have primarily focused on patients whose PVC burden increased rather than including the full spectrum of outcomes. METHODS AND RESULTS: We performed a single-center retrospective cohort study of consecutive patients who underwent first-time AF ablation from 1/2018 to 12/2022 for paroxysmal or persistent AF and had both preablation and postablation rhythm monitoring within 6 months of the procedure. Patients were excluded if they had prior AF or PVC ablation or were prescribed a class I or III antiarrhythmic medication. Among 2945 patients who underwent AF ablation during the study period, 130 patients underwent first-time AF ablation and received both pre and post ambulatory monitoring. The median PVC burden before ablation was <1%. Most patients (63%) had no change in PVC burden after AF ablation compared with preablation, and patients who had an increase in PVC burden were offset by those with reductions in PVCs. A paired analysis pre- and post-AF ablation showed no significant change in PVC burden (p = .495). CONCLUSION: Although an elevated PVC burden after AF ablation may be seen clinically, the majority of patients have no change in burden. Studies that suggest an increase in PVC burden after AF ablation may suffer from incomplete sample selection and thus omit the important effect of regression to the mean.

7.
Circ Arrhythm Electrophysiol ; : e012854, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38758741

RESUMO

BACKGROUND: Unlike conventional microsecond pulsed electrical fields that primarily target the cell membranes, nanosecond pulses are thought to primarily electroporate intracellular organelles. We conducted a comprehensive preclinical assessment of catheter-based endocardial nanosecond pulsed field ablation in swine. METHODS: A novel endocardial nanosecond pulsed field ablation system was evaluated in a total of 25 swine. Using either a low-dose (5-second duration) or high-dose (15-second duration) strategy, thoracic veins and discrete atrial and ventricular sites were ablated. Swine survived for <1 (n=1), ≈2 (n=7), ≈7 (n=6), 14 (n=2), or ≈28 (n=9) days, and venous isolation was assessed before euthanize. Safety assessments included evaluation of esophageal effects, phrenic nerve function, and changes in venous caliber. All tissues were subject to careful gross pathological and histopathologic examination. RESULTS: All (100%) veins (13 low-dose, 34 high-dose) were acutely isolated, and all reassessed veins (6 low-dose, 15 high-dose) were durably isolated. All examined vein lesions (10 low-dose, 22 high-dose) were transmural. Vein diameters (n=15) were not significantly changed. Of the animals assessed for phrenic palsy (n=9), 3 (33%) demonstrated only transient palsy. There were no differences between dosing strategies. Thirteen mitral isthmus lesions were analyzed, and all 13 (100%) were transmural (depth, 6.4±0.4 mm). Ventricular lesions were 14.7±4.5 mm wide and 7.1±1.3 mm deep, with high-dose lesions deeper than low-dose (7.9±1.2 versus 6.2±0.8 mm; P=0.007). The esophagus revealed nontransmural adventitial surface lesions in 5 of 5 (100%) animals euthanized early (2 days) post-ablation. In the 10 animals euthanized later (14-28 days), all animals demonstrated significant esophageal healing-8 with complete resolution, and 2 with only trace fibrosis. CONCLUSIONS: A novel, endocardial nanosecond pulsed field ablation system provides acute and durable venous isolation and linear lesions. Transient phrenic injury and nontransmural esophageal lesions can occur with worst-case assessments suggesting limits to pulsed field ablation tissue selectivity and the need for dedicated assessments during clinical studies.

9.
Heart Rhythm ; 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38768840

RESUMO

BACKGROUND: During pulsed field ablation (PFA), electrode-tissue proximity optimizes lesion quality. A novel "single-shot" map-and-ablate spherical multielectrode PFA array catheter that is able to verify electrode-tissue contact was recently studied in a first-in-human trial of atrial fibrillation (AF). OBJECTIVE: The aim of this study was to report lesion durability data, safety, and 12-month effectiveness outcomes. METHODS: The spherical PFA catheter, an all-in-one mapping and ablation system, was used to render anatomy and to deliver biphasic pulses (ungated 1.7 kV pulses; ∼40 seconds/application). Ablation sites included pulmonary veins (PVs) and, in selected patients, posterior wall and mitral isthmus. Follow-up was invasive remapping at ∼3 months, electrocardiograms, Holter monitoring at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy end points were acute PV isolation (PVI), PVI durability, and atrial arrhythmia recurrence. RESULTS: In the 48-patient AF cohort (paroxysmal, 48%; persistent, 52%), lesion sets included PVI (n = 48; 1.2 applications/PV), posterior wall (n = 20; 3.6 applications/posterior wall), and mitral isthmus (n = 11; 2.9 applications/mitral isthmus). Lesions were acutely successful for all 187 of 187 PVs (100%), 20 of 20 posterior walls (100%), and 10 of 11 mitral isthmuses (91%). Pulse delivery time, left atrial catheter dwell time, and procedure time were 61.5 ± 32.8 seconds, 53.9 ± 26.5 minutes, and 87.8 ± 29.8 minutes, respectively. Remapping (43/48 patients [89.5%]) revealed that 158 of 169 PVs (93.5%) were durably isolated. The only complication was a drug-responsive pericarditis. The 1-year Kaplan-Meier estimates of freedom from atrial arrhythmia were 84.2% (paroxysmal AF) and 80.0% (persistent AF). CONCLUSION: The single-shot spherical array PFA catheter can safely achieve durable lesions, translating into good clinical efficacy. GOV IDENTIFIER: NCT05164107.

10.
Nat Med ; 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38760584

RESUMO

Clinical outcomes of catheter ablation for atrial fibrillation (AF) are suboptimal due, in part, to challenges in achieving durable lesions. Although focal point-by-point ablation allows for the creation of any required lesion set, this strategy necessitates the generation of contiguous lesions without gaps. A large-tip catheter, capable of creating wide-footprint ablation lesions, may increase ablation effectiveness and efficiency. In a randomized, single-blind, non-inferiority trial, 420 patients with persistent AF underwent ablation using a large-tip catheter with dual pulsed field and radiofrequency energies versus ablation using a conventional radiofrequency ablation system. The primary composite effectiveness endpoint was evaluated through 1 year and included freedom from acute procedural failure and repeat ablation at any time, plus arrhythmia recurrence, drug initiation or escalation or cardioversion after a 3-month blanking period. The primary safety endpoint was freedom from a composite of serious procedure-related or device-related adverse events. The primary effectiveness endpoint was observed for 73.8% and 65.8% of patients in the investigational and control arms, respectively (P < 0.0001 for non-inferiority). Major procedural or device-related complications occurred in three patients in the investigational arm and in two patients in the control arm (P < 0.0001 for non-inferiority). In a secondary analysis, procedural times were shorter in the investigational arm as compared to the control arm (P < 0.0001). These results demonstrate non-inferior safety and effectiveness of the dual-energy catheter for the treatment of persistent AF. Future large-scale studies are needed to gather real-world evidence on the impact of the focal dual-energy lattice catheter on the broader population of patients with AF. ClinicalTrials.gov identifier: NCT05120193 .

11.
N Engl J Med ; 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38767244

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) is associated with fewer lead-related complications than a transvenous ICD; however, the subcutaneous ICD cannot provide bradycardia and antitachycardia pacing. Whether a modular pacing-defibrillator system comprising a leadless pacemaker in wireless communication with a subcutaneous ICD to provide antitachycardia and bradycardia pacing is safe remains unknown. METHODS: We conducted a multinational, single-group study that enrolled patients at risk for sudden death from ventricular arrhythmias and followed them for 6 months after implantation of a modular pacemaker-defibrillator system. The safety end point was freedom from leadless pacemaker-related major complications, evaluated against a performance goal of 86%. The two primary performance end points were successful communication between the pacemaker and the ICD (performance goal, 88%) and a pacing threshold of up to 2.0 V at a 0.4-msec pulse width (performance goal, 80%). RESULTS: We enrolled 293 patients, 162 of whom were in the 6-month end-point cohort and 151 of whom completed the 6-month follow-up period. The mean age of the patients was 60 years, 16.7% were women, and the mean (±SD) left ventricular ejection fraction was 33.1±12.6%. The percentage of patients who were free from leadless pacemaker-related major complications was 97.5%, which exceeded the prespecified performance goal. Wireless-device communication was successful in 98.8% of communication tests, which exceeded the prespecified goal. Of 151 patients, 147 (97.4%) had pacing thresholds of 2.0 V or less, which exceeded the prespecified goal. The percentage of episodes of arrhythmia that were successfully terminated by antitachycardia pacing was 61.3%, and there were no episodes for which antitachycardia pacing was not delivered owing to communication failure. Of 162 patients, 8 died (4.9%); none of the deaths were deemed to be related to arrhythmias or the implantation procedure. CONCLUSIONS: The leadless pacemaker in wireless communication with a subcutaneous ICD exceeded performance goals for freedom from major complications related to the leadless pacemaker, for communication between the leadless pacemaker and subcutaneous ICD, and for the percentage of patients with a pacing threshold up to 2.0 V at a 0.4-msec pulse width at 6 months. (Funded by Boston Scientific; MODULAR ATP ClinicalTrials.gov NCT04798768.).

12.
Heart Rhythm ; 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38697271

RESUMO

BACKGROUND: The first dual-chamber leadless pacemaker (DC-LP) system consists of 2 separate atrial and ventricular devices that communicate to maintain synchronous atrioventricular pacing and sensing. The initial safety and efficacy were previously reported. OBJECTIVE: The purpose of this study was to evaluate the chronic electrical performance of the DC-LP system. METHODS: Patients meeting standard dual-chamber pacing indications were enrolled and implanted with the DC-LP system (Aveir DR, Abbott), including right atrial and ventricular helix-fixation LPs (atrial leadless pacemaker [ALP], ventricular leadless pacemaker [VLP]). Pacing capture threshold, sensed amplitude, and pacing impedance were collected using the device programmer at prespecified timepoints from 0-6 months postimplant. RESULTS: De novo devices were successfully implanted in 381 patients with complete 6-month data (62% male; age 69 ± 14 years; weight 82 ± 20 kg; 65% sinus nodal dysfunction, 30% atrioventricular block). ALPs were implanted predominantly in the right atrial appendage anterior base and VLPs primarily at the mid-to-apical right ventricular septum. From implant to 1 month, pacing capture thresholds (0.4-ms pulse width) improved in both ALPs (2.4 ± 1.5 V to 0.8 ± 0.8 V; P <.001) and VLPs (0.8 ± 0.6 V to 0.6 ± 0.4 V; P <.001). Sensed amplitudes improved in both ALPs (1.8 ± 1.3 mV to 3.4 ± 1.9 mV; P <.001) and VLPs (8.8 ± 4.0 mV to 11.7 ± 4.2 mV; P <.001). Impedances were stable in ALPs (334 ± 68 Ω to 329 ± 52 Ω; P = .17) and reduced in VLPs (789 ± 351 Ω to 646 ± 190 Ω; P <.001). Electrical measurements remained relatively stable from 1-6 months postimplant. No differences in electrical metrics were observed among ALP or VLP implant locations. CONCLUSION: This first in-human evaluation of the new dual-chamber leadless pacemaker system demonstrated reliable electrical performance throughout the initial 6-month evaluation period.

13.
Heart Rhythm ; 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38752906

RESUMO

BACKGROUND: Rapid technologic development and expansion of procedural expertise have led to widespread proliferation of catheter-based electrophysiology procedures. It is unclear whether these advances come at cost to patient safety. OBJECTIVE: This meta-analysis aimed to assess complication rates after modern electrophysiology procedures during the lifetime of the procedures. METHODS: A comprehensive search was performed to identify relevant data published before May 30, 2023. Studies were included if they met the following inclusion criteria: prospective trials or registries, including comprehensive complications data; and patients undergoing atrial fibrillation ablation, ventricular tachyarrhythmia ablation, leadless cardiac pacemaker implantation, and percutaneous left atrial appendage occlusion. Pooled incidences of procedure-related complications were individually assessed by random effects models to account for heterogeneity. Temporal trends in complications were investigated by clustering trials by publication year (2000-2018 vs 2019-2023). RESULTS: A total of 174 studies (43,914 patients) met criteria for analysis: 126 studies of atrial fibrillation ablation (n = 24,057), 25 studies of ventricular tachyarrhythmia ablation (n = 1781), 21 studies of leadless cardiac pacemaker (n = 8896), and 18 studies of left atrial appendage occlusion (n = 9180). The pooled incidences of serious procedure-related complications (3.49% [2000-2018] vs 3.05% [2019-2023]; P < .001), procedure-related stroke (0.46% vs 0.28%; P = .002), pericardial effusion requiring intervention (1.02% vs 0.83%; P = .037), and procedure-related death (0.15% vs 0.06%; P = .003) significantly decreased over time. However, there was no significant difference in the incidence of vascular complications over time (1.86% vs 1.88%; P = .888). CONCLUSION: Despite an increase in cardiac electrophysiology procedures, procedural safety has improved over time.

14.
Circ Arrhythm Electrophysiol ; 17(6): e012734, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38753535

RESUMO

BACKGROUND: Endocardial catheter-based pulsed field ablation (PFA) of the ventricular myocardium is promising. However, little is known about PFA's ability to target intracavitary structures, epicardium, and ways to achieve transmural lesions across thick ventricular tissue. METHODS: A lattice-tip catheter was used to deliver biphasic monopolar PFA to swine ventricles under general anesthesia, with electroanatomical mapping, fluoroscopy and intracardiac echocardiography guidance. We conducted experiments to assess the feasibility and safety of repetitive monopolar PFA applications to ablate (1) intracavitary papillary muscles and moderator bands, (2) epicardial targets, and (3) bipolar PFA for midmyocardial targets in the interventricular septum and left ventricular free wall. RESULTS: (1) Papillary muscles (n=13) were successfully ablated and then evaluated at 2, 7, and 21 days. Nine lesions with stable contact measured 18.3±2.4 mm long, 15.3±1.5 mm wide, and 5.8±1.0 mm deep at 2 days. Chronic lesions demonstrated preserved chordae without mitral regurgitation. Two targeted moderator bands were transmurally ablated without structural disruption. (2) Transatrial saline/carbon dioxide assisted epicardial access was obtained successfully and epicardial monopolar lesions had a mean length, width, and depth of 30.4±4.2, 23.5±4.1, and 9.1±1.9 mm, respectively. (3) Bipolar PFA lesions were delivered across the septum (n=11) and the left ventricular free wall (n=7). Twelve completed bipolar lesions had a mean length, width, and depth of 29.6±5.5, 21.0±7.3, and 14.3±4.7 mm, respectively. Chronically, these lesions demonstrated uniform fibrotic changes without tissue disruption. Bipolar lesions were significantly deeper than the monopolar epicardial lesions. CONCLUSIONS: This in vivo evaluation demonstrates that PFA can successfully ablate intracavitary structures and create deep epicardial lesions and transmural left ventricular lesions.


Assuntos
Ablação por Cateter , Ventrículos do Coração , Septo Interventricular , Animais , Septo Interventricular/fisiopatologia , Septo Interventricular/diagnóstico por imagem , Septo Interventricular/cirurgia , Ablação por Cateter/métodos , Ablação por Cateter/instrumentação , Suínos , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Estudos de Viabilidade , Músculos Papilares/fisiopatologia , Músculos Papilares/cirurgia , Músculos Papilares/diagnóstico por imagem , Fatores de Tempo , Pericárdio/cirurgia , Pericárdio/fisiopatologia , Cateteres Cardíacos , Ultrassonografia de Intervenção , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Feminino
16.
Circ Arrhythm Electrophysiol ; 17(5): e012667, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38655693

RESUMO

BACKGROUND: We previously presented the safety and early efficacy of the inspIRE study (Study for Treatment of Paroxysmal Atrial Fibrillation [PAF] by Pulsed-field Ablation [PFA] System With Irreversible Electroporation [IRE]). With the study's conclusion, we report the outcomes of the full pivotal study cohort, with an additional analysis of predictors of success. METHODS: InspIRE was a prospective, multicenter, single-arm clinical trial of drug-refractory paroxysmal atrial fibrillation. Pulmonary vein isolation was performed with a variable-loop circular catheter integrated with a 3-dimensional mapping system. Follow-up with 24-hour Holter was at 3, 6, and 12 months, as well as remote rhythm monitoring: weekly from 3 to 5 months, monthly from 6 to 12 months, and for symptoms. The primary effectiveness end point (PEE) was acute pulmonary vein isolation plus freedom from any atrial arrhythmia at 12 months. Additional subanalyses report predictors of PEE success. RESULTS: The patient cohort included 186 patients: aged 59±10 years, female 30%, and CHA2DS2-VASc 1.3±1.2. The previously reported primary adverse event rate was 0%. One serious procedure-related adverse event, urinary retention, was reported. The PEE was achieved in 75.6% (95% CI, 69.5%-81.8%). The clinical success of freedom from symptomatic recurrence was 81.7% (95% CI, 76.1%-87.2%). Simulating a monitoring method used in standard real-world practice (without protocol-driven remote rhythm monitoring), this translates to a freedom from all and symptomatic recurrence of 85.8% (95% CI, 80.8%-90.9%) or 94.0% (95% CI, 90.6%-97.5%), respectively. Multivariate analyses revealed that left ventricular ejection fraction ≥60% (adjusted odds ratio, 0.30) and patients receiving ≥48 PFA applications (adjusted odds ratio, 0.28) were independent predictors of PEE success. Moreover, PEE success was 79.2% in patients who received ≥12 PFA applications per vein compared with 57.1% in patients receiving fewer PFA applications. CONCLUSIONS: The inspIRE study confirms the safety and effectiveness of pulmonary vein isolation using the novel 3-dimensional mapping integrated circular loop catheter. An optimal number of PFA applications (≥48 total or ≥12 per vein) resulted in an improved 1-year success rate of ≈80%. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04524364.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Feminino , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino , Pessoa de Meia-Idade , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Estudos Prospectivos , Idoso , Fatores de Tempo , Frequência Cardíaca , Potenciais de Ação , Eletrocardiografia Ambulatorial/instrumentação , Recidiva , Cateteres Cardíacos , Valor Preditivo dos Testes , Resultado do Tratamento , Imageamento Tridimensional , Fatores de Risco , Desenho de Equipamento , Técnicas Eletrofisiológicas Cardíacas
17.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584468

RESUMO

AIMS: Pulsed field ablation (PFA) has significant advantages over conventional thermal ablation of atrial fibrillation (AF). This first-in-human, single-arm trial to treat paroxysmal AF (PAF) assessed the efficiency, safety, pulmonary vein isolation (PVI) durability and one-year clinical effectiveness of an 8 Fr, large-lattice, conformable single-shot PFA catheter together with a dedicated electroanatomical mapping system. METHODS AND RESULTS: After rendering the PV anatomy, the PFA catheter delivered monopolar, biphasic pulse trains (5-6 s per application; ∼4 applications per PV). Three waveforms were tested: PULSE1, PULSE2, and PULSE3. Follow-up included ECGs, Holters at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy endpoints were acute PVI and post-blanking atrial arrhythmia recurrence, respectively. Invasive remapping was conducted ∼75 days post-ablation. At three centres, PVI was performed by five operators in 85 patients using PULSE1 (n = 30), PULSE2 (n = 20), and PULSE3 (n = 35). Acute PVI was achieved in 100% of PVs using 3.9 ± 1.4 PFA applications per PV. Overall procedure, transpired ablation, PFA catheter dwell and fluoroscopy times were 56.5 ± 21.6, 10.0 ± 6.0, 19.1 ± 9.3, and 5.7 ± 3.9 min, respectively. No pre-defined primary safety events occurred. Upon remapping, PVI durability was 90% and 99% on a per-vein basis for the total and PULSE3 cohort, respectively. The Kaplan-Meier estimate of one-year freedom from atrial arrhythmias was 81.8% (95% CI 70.2-89.2%) for the total, and 100% (95% CI 80.6-100%) for the PULSE3 cohort. CONCLUSION: Pulmonary vein isolation (PVI) utilizing a conformable single-shot PFA catheter to treat PAF was efficient, safe, and effective, with durable lesions demonstrated upon remapping.


Assuntos
Fibrilação Atrial , Cateteres Cardíacos , Ablação por Cateter , Veias Pulmonares , Recidiva , Humanos , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Ablação por Cateter/métodos , Ablação por Cateter/instrumentação , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Desenho de Equipamento , Técnicas Eletrofisiológicas Cardíacas , Fatores de Tempo , Frequência Cardíaca , Potenciais de Ação
18.
J Pharm Bioallied Sci ; 16(Suppl 1): S850-S852, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595389

RESUMO

Background: Open bite is a common orthodontic malocclusion that can have functional and aesthetic implications. Traditional orthodontic treatments have been used to correct open bites, but the effectiveness of Invisalign, a clear aligner therapy, in open bite correction remains a topic of interest. Materials and Methods: A retrospective analysis was conducted on a cohort of 50 patients with open bites who underwent Invisalign treatment. Pre-treatment and post-treatment records, including cephalometric radiographs, dental models, and clinical photographs, were assessed. The open bite was defined as a negative overbite greater than 2 mm. Treatment duration, number of aligners used, and patient compliance were also recorded. Statistical analysis, including paired t-tests and subjective patient feedback, was employed to evaluate the treatment outcomes. Results: The mean pre-treatment open bite was -3.5 mm (SD = 1.2), and the mean treatment duration was 18 months (SD = 2.5). On average, patients received 24 sets of aligners (SD = 4.1) during the treatment. Post-treatment evaluation showed that the mean overbite improved to + 1.5 mm (SD = 0.8), indicating successful open bite correction. The paired t-test revealed a statistically significant difference between pre-treatment and post-treatment open bite measurements (P < 0.001). Patient satisfaction was high, with 90% of participants reporting improved aesthetics and comfort. Conclusion: Invisalign treatment demonstrates effectiveness in correcting open bites, with statistically significant improvements in overbite measurements.

19.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38582974

RESUMO

AIMS: The ultra-low-temperature cryoablation (ULTC) ablation system using -196°C N2 cryogen has been reported to create lesions with freeze duration-dependent depth titratable to over 10 mm with minimum attenuation by scar. Cryocure-VT (NCT04893317) was a first-in-human clinical trial evaluating the safety and efficacy of a novel, purpose-built ULTC catheter in endocardial ablation of scar-dependent ventricular tachycardias (VTs). METHODS AND RESULTS: This prospective, multi-centre study enrolled patients referred for de novo or second ablations of recurrent monomorphic VT of both ischaemic and non-ischaemic aetiologies. Primary safety and efficacy endpoints of the study were freedom from device- or procedure-related major adverse events (MAEs) up to 30 days post-ablation, acute non-inducibility of clinical VTs at the end of the procedure, and freedom from sustained VT or implantable defibrillator intervention at 6 months. Ultra-low-temperature cryoablation was performed in 64 patients (age 67 ± 11 years, 78% ischaemic, ejection fraction = 35 ± 10%) at 9 centres. The primary acute effectiveness endpoint was achieved in 94% (51/54) of patients in whom post-ablation induction was attempted. There were no protocol-defined MAEs; four procedure-related serious adverse events resolved without clinical sequelae. At 6-month follow-up, 38 patients (60.3%) remained VT-free, and freedom from defibrillator shock was 81.0%, with no significant difference between ischaemic and non-ischaemic cohorts. In 47 patients with defibrillator for at least 6 months prior to the ablation, the VT burden was reduced from median of 4, inter-quartile range (IQR, 1-9) to 0, IQR (0-2). CONCLUSION: In this first-in-human multi-centre experience, endocardial ULTC ablation of monomorphic VT appears safe and effective in patients with both ischaemic-cardiomyopathy and non-ischaemic-cardiomyopathy. CLINICAL TRIAL REGISTRATION: NCT04893317.


Assuntos
Cardiomiopatias , Ablação por Cateter , Criocirurgia , Taquicardia Ventricular , Idoso , Humanos , Pessoa de Meia-Idade , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Cardiomiopatias/cirurgia , Ablação por Cateter/efeitos adversos , Cicatriz/complicações , Criocirurgia/efeitos adversos , Estudos Prospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Temperatura , Resultado do Tratamento