Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Farm Hosp ; 48(3): T129-T132, 2024.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38553258

RESUMO

OBJECTIVE: Skin burns are associated with the presence of metallic components in transdermal drug delivery systems during Magnetic Resonance Imaging, cardioversion or defibrillation procedures. The aim of the study was to review the presence of metallic components in marketed products of transdermal drug delivery systems in Spain. METHOD: For each presentation, the summary of product characteristics was reviewed. If the information was not provided, manufacturers were contacted. RESULTS: We identified 59 marketed products of transdermal drug delivery systems of 12 different active substances. 59.3% of patches contained metallic components or their presence could not be ruled out. Information regarding the need to remove the patch was only included in 8 summaries of product characteristics (13.6%). A table was elaborated and included the following aspects: product, active substance, manufacturer, need to remove the patch before the exposure to magnetic or electric fields and references. CONCLUSION: More than a half of the patches at the time of the study contained metals or their absence could not be confirmed by the manufacturer. However, this information was only included in 13.6% of summaries of product characteristics.


Assuntos
Administração Cutânea , Sistemas de Liberação de Medicamentos , Metais , Humanos , Pele/lesões , Espanha , Queimaduras , Adesivo Transdérmico
2.
Farm Hosp ; 2023 Dec 05.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38057241

RESUMO

OBJECTIVE: Skin burns are associated with the presence of metallic components in transdermal drug delivery systems during Magnetic Resonance Imaging, cardioversion, or defibrillation procedures. The aim of the study was to review the presence of metallic components in marketed products of transdermal drug delivery systems in Spain. METHOD: For each pharmaceutical form, the summary of product characteristics was reviewed. If the information was not provided, manufacturers were contacted. RESULTS: We identified 59 marketed products of transdermal drug delivery systems of 12 different active substances. 59.3% of patches contained metallic components or their presence could not be ruled out. Information regarding the need to remove the patch was only included in 8 summaries of product characteristics (13.6%) A table was elaborated and included the following aspects: product, active substance, manufacturer, need to remove the patch before the exposure to magnetic or electric fields, and references. CONCLUSION: More than a half of the patches at the time of the study contained metals or their absence could not be confirmed by the manufacturer. However, this information was only included in 13.6% of summaries of product characteristics.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA