1.
PLoS One ; 16(9): e0256985, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34473779

RESUMO

This multicenter, open-label study aimed to determine the safety and functional outcome of a high-addition segmented refractive bifocal intraocular lens (IOL) in late inactive age-related macular degeneration (AMD). Twenty eyes of 20 patients were enrolled and followed until 12 months after the intervention. Patients underwent cataract surgery with implantation of a LS-313 MF80 segmented refractive bifocal intraocular lens with a near addition of +8.0 D (Teleon Surgical Vertriebs GmbH, Berlin, Germany). The main outcome measures were distance corrected near visual acuity (DCNVA) and safety as determined by intra- and post-operative complications. Secondary outcomes included distance corrected visual acuity (CDVA), uncorrected distance visual acuity (UDVA), uncorrected near visual acuity (UNVA), the need for magnification to read newspaper, preferred reading distance, speed and performance (logRAD), as well as patient satisfaction. Mean DCNVA improved from 0.95 (±0.19) to 0.74 (±0.35) logMAR, until 6 months after surgery, P<0.05. CDVA improved from 0.70 (±0.23) to 0.59 (±0.30) logMAR, UDVA from 0.94 (±0.25) to 0.69 (±0.34) logMAR, UNVA from 1.08 (±0.19) to 0.87 (±0.43) logMAR. The mean need for magnification decreased from 2.9- to 2.3-fold, preferred reading distance from 23 to 20 cm. No intraoperative complications occurred during any of the surgeries. One patient lost > 2 lines of CDVA between 6 and 12 months, in another case, the study IOL was exchanged for a monofocal one due to dysphotopsia and decreased CDVA. Implantation of a segmented refractive bifocal IOL with +8.0 D addition improves near and distance vision in patients with late AMD and has a satisfactory safety profile.


Assuntos
Extração de Catarata/efeitos adversos , Extração de Catarata/métodos , Implante de Lente Intraocular/efeitos adversos , Implante de Lente Intraocular/métodos , Lentes Intraoculares , Degeneração Macular/cirurgia , Desenho de Prótese , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Degeneração Macular/diagnóstico por imagem , Masculino , Projetos Piloto , Complicações Pós-Operatórias , Leitura , Refração Ocular , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento , Acuidade Visual
2.
J Refract Surg ; 29(3): 187-93, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23446015

RESUMO

PURPOSE: To analyze the refractive outcomes and safety of three-piece silicone toric sulcus-fixated add-on intraocular lenses (IOLs) (HumanOptics/Dr.Schmidt Intraocularlinsen, Erlangen, Germany) in complex clinical cases with high astigmatism such as in cases with previous penetrating keratoplasty. METHODS: Interventional case series of 21 eyes of 20 patients enrolled at two German centers. Functional results including power vector analysis, accuracy of IOL power calculation, rotational stability, and postoperative complications were evaluated from 2 months to 6 years postoperatively. RESULTS: The preoperative subjective cylinder exceeded or was equal to -6.00 diopters (D) in 81% of eyes (range: -2.00 to -17.00 D). The median follow-up period was 7.6 months (range: 57 days to 6 years). The efficacy analysis focused on the 2 to 6 months follow-up visit. Postoperatively, there was a median reduction of astigmatism by 70.59% (subjective cylinder range: 0.00 to -5.00 D), improvement of uncorrected distance visual acuity, and unchanged median corrected distance visual acuity. The attempted spherical equivalent was achieved within ± 0.50 D in 45% and within ± 1.00 D in 65% of cases. Five eyes received secondary surgical alignment of axis. Other complications related to the surgical procedure were mainly transient shortly after implantation, such as intraocular pressure elevation (2 of 21 eyes) or corneal edema (2 of 21 eyes). Persisting changes were seen only in rare cases and included pigment dispersion (1 of 21 eyes) or corneal edema requiring a second keratoplasty within 9 months after surgery (2 of 21 eyes). CONCLUSIONS: Toric add-on IOLs may be useful in reducing high astigmatism and anisometropia and increasing spectacle independence even in complex clinical conditions with high refractive errors.


Assuntos
Astigmatismo/cirurgia , Implante de Lente Intraocular , Lentes Intraoculares , Elastômeros de Silicone , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Ceratoplastia Penetrante , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Desenho de Prótese , Refração Ocular/fisiologia , Estudos Retrospectivos , Resultado do Tratamento , Acuidade Visual/fisiologia