Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMC Cardiovasc Disord ; 15: 181, 2015 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-26715337

RESUMO

BACKGROUND: Accurate preoperative assessment of the aortic annulus dimension is crucial for successful transcatheter aortic valve implantation (TAVI). In this study we examined the accuracy of a novel method using two-dimensional transesophageal echocardiography (2D-TEE) for measurement of the aortic annulus. METHODS: We evaluated the theoretical impact of the measurement of the annulus diameter and area using the circumcircle of a triangle method on the decision to perform the procedure and choice of the prosthesis size. RESULTS: Sixty-three consecutive patients were scheduled for TAVI. Mean age was 82 ± 4 years, and 25 patients (55.6 %) were female. Mean aortic annulus diameter was 20.3 ± 2.2 mm assessed by TEE on the mid-esophageal long-axis view and 23.9 ± 2.3 mm using CT (p < 0.001). There was a tendency for the TEE derived areas using the new method to be higher (p < 0.001). The TEE measurements were on average 42.33 mm(2) higher than the CT measurements without an evidence of a systematic over- or under-sizing (p = 1.00). Agreement between TEE and CT chosen valve sizes was good overall (kappa = 0.67 and weighted kappa = 0.71). For patients who turned out to have no AR, the two methods agreed in 84.6 % of patients. CONCLUSIONS: CT remanis the gold standard in sizing of the aortic valve annulus. Nevertheless, sizing of the aortic valve annulus using TEE derived area may be helpful. The impact of integration of this method in the algorithm of aortic annulus sizing on the outcome of patients undergoing TAVI should be examined in future studies.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/terapia , Valva Aórtica/diagnóstico por imagem , Bioprótese , Cateterismo Cardíaco/instrumentação , Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Desenho de Prótese , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Valvuloplastia com Balão , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA