Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros

Ano de publicação
Intervalo de ano de publicação
1.
J Mater Sci Mater Med ; 35(1): 52, 2024 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-39177838

RESUMO

Because nickel-titanium (NiTi) alloys have unique functions, such as superelasticity, shape memory, and hysteresis similar to bone in the loading-unloading cycles of their recoverable deformations. They likely offer good bone integration, a low loosening rate, individual customization, and ease of insertion. Due to the poor processability of NITI, traditional methods cannot manufacture NiTi products with complex shapes. Orthopedic NiTi implants need to show an adequate fracture elongation of at least 8%. Additive manufacturing can be used to prepare NiTi implants with complex structures and tunable porosity. However, as previously reported, additively manufactured NiTi alloys could only exhibit a maximum tensile fracture strain of 7%. In new reports, a selective laser melting (SLM)-NiTi alloy has shown greater tensile strain (15.6%). Nevertheless, due to the unique microstructure of additive manufacturing NiTi that differs from traditional NITI, the biocompatibility of SLM-NITI manufactured by this new process requires further evaluation In this study, the effects of the improved NiTi alloy on bone marrow mesenchymal stem cell (BMSC) proliferation, adhesion, and cell viability were investigated via in vitro studies. A commercial Ti-6Al-4V alloy was studied side-by-side for comparison. Like the Ti-6Al-4V alloy, the SLM-NiTi alloy exhibited low cytotoxicity toward BMSCs and similar effect on cell adhesion or cell viability. This study demonstrates that the new SLM-NiTi alloy, which has exhibited improved mechanical properties, also displays excellent biocompatibility. Therefore, this alloy may be a superior implant material in biomedical implantation.


Assuntos
Ligas , Materiais Biocompatíveis , Adesão Celular , Proliferação de Células , Sobrevivência Celular , Teste de Materiais , Células-Tronco Mesenquimais , Níquel , Resistência à Tração , Titânio , Titânio/química , Materiais Biocompatíveis/química , Ligas/química , Células-Tronco Mesenquimais/efeitos dos fármacos , Células-Tronco Mesenquimais/citologia , Níquel/química , Sobrevivência Celular/efeitos dos fármacos , Adesão Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Animais , Lasers , Próteses e Implantes , Estresse Mecânico , Propriedades de Superfície
2.
Acta Biomater ; 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39097125

RESUMO

Macrostructural control of stress distribution and microstructural influence on crack propagation is one of the strategies for obtaining high mechanical properties in stag beetle upper jaws. The maximum bending fracture force of the stag beetle upper jaw is approximately 154, 000 times the weight of the upper jaw. Here, we explore the macro and micro-structural characteristics of two stag beetle upper jaws and reveal the resulting differences in mechanical properties and enhancement mechanisms. At the macroscopic level, the elliptic and triangular cross-sections of the upper jaw of the two species of stag beetles have significant effects on the formation of cracks. The crack generated by the upper jaws with a triangular section grows slowly and deflects easily. At the microscopic level, the upper jaw of the two species is a chitin cross-layered structure, but the difference between the two adjacent fiber layers at 45° and 50° leads to different deflection paths of the cracks on the exoskeleton. The mechanical properties of the upper jaw of the two species of stag beetle were significantly different due to the interaction of macro-structure and micro-structure. In addition, a series of bionic samples with different cross-section geometries and different fiber cross angles were designed, and mechanical tests were carried out according to the macro-structure and micro-structure characteristics of the stag beetle upper jaw. The effects of cross-section geometry and fiber cross angle on the mechanical properties of bionic samples are compared and analyzed. This study provides new ideas for designing and optimizing highly loaded components in engineering. STATEMENT OF SIGNIFICANCE: The upper jaw of the stag beetle is composed of a complex arrangement of chitin and protein fibers, providing both rigidity and flexibility. This structure is designed to withstand various mechanical stresses, including impacts and bending forces, encountered during its burrowing activities and interactions with its environment. The study of the upper jaw of the stag beetle can provide an efficient structural design for engineering components that are subjected to high loads. Understanding the relationship between structure and mechanical properties in the stag beetle upper jaw holds significant implications for biomimetic design and engineering.

3.
Adv Mater ; : e2406432, 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39081104

RESUMO

Highly robust soft strain gauges are rapidly emerging as a promising candidate in the fields of vital signs and machine conditions monitoring. However, it is still a key challenge to achieve high-performance strain sensing in these sensors with mechanical/electrical robustness for long-term usage. The multilayer structural design of sensors enhances sensing performance while the interfacial connection of heterogeneous materials between different layers is weak. Herein, inspired by the efficient perception mechanism of scorpion slit sensilla with tough interface interconnections, the synergy of ultra-high electrical performance and mechanical robustness is successfully achieved via interface design engineering. The developed multilayer soft strain gauge (MSSG) exhibits a strain sensitivity beyond 105, a lower detection limit of 8.3 µm, a frequency resolution within 0.1 Hz, and cyclic stability over 63 000 strain cycles. Also, the tough interface improves the level of heterogeneous integration in the MSSG which allows to endure different stresses. Furthermore, an MSSG-based wireless strain monitoring system is developed that enables applications on different complex dynamic surfaces, including accurate identification of human throat activity and monitoring of rolling bearing conditions.

4.
Biomimetics (Basel) ; 9(7)2024 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-39056868

RESUMO

In this study, based on the principles of bionics, we fabricated a bionic non-smooth concave pit structure on the shoulders of friction stir welding tools and detected the thermal cycling curve, downforce, and torque of the tool in the welding process. We tested the wear loss weight and analyzed the surface morphology of the shoulder surfaces after welding for 200 m. This study found that as the distance between the concave pits decreased and the number of concave pits increased, the maximum downforce, torque, and temperature in the welding process showed a decreasing trend. As the speed increased, no matter how the tool structure changed, the downforce and torque decreased, while the peak thermal cycle temperature increased. The experimental welding results show that the wear loss weight of the non-smooth structure tool significantly reduced. The lowest wear loss weight of the tool with a concave pit interval of 1.125 mm was only 0.1529 g, which is 27% lower than that of the conventional tool. Our observations of the surface morphology of the tool shoulder after welding showed that the amount of aluminum swarf on the tool shoulder of the welding tool gradually declined with the increasing density of the uneven pits. The lowest number of aluminum chips adhered to a welding tool with a pit distance of 1.125 mm. Therefore, friction stir welding tools with biomimetic structures have better wear resistance and adhesion resistance.

5.
Materials (Basel) ; 17(11)2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38893742

RESUMO

High-strength low-alloy steels are widely used, but their traditional heat-treatment process is complex, energy-intensive, and makes it difficult to fully exploit the material's potential. In this paper, the electropulsing processing technology was applied to the quenching and tempering process of ZG25SiMn2CrB steel. Through microstructural characterization and mechanical property testing, the influence of electropulsing on the solid-state phase transition process of annealing steel was systematically studied. The heating process of the specimen with the annealing state (initial state) is the diffusion-type transition. As the discharge time increased, the microstructure gradually transformed from ferrite/pearlitic to slate martensite. Optimal mechanical properties and fine microstructure were achieved after quenching at 500 ms. The steel subjected to rapid tempering with 160 ms electropulsing exhibited good, comprehensive mechanical properties (tensile strength 1609 MPa, yield strength 1401.27 MPa, elongation 11.63%, and hardness 48.68 HRC). These favorable mechanical properties are attributed to the coupled impact of thermal and non-thermal effects induced by high-density pulse current. Specifically, the thermal effect provides the thermodynamic conditions for phase transformation, while the non-thermal effect reduces the nucleation barrier of austenite, which increases the nucleation rate during instantaneous heating, and the following rapid cooling suppresses the growth of austenite grains. Additionally, the fine microstructure prevents the occurrence of temper brittleness.

6.
3D Print Addit Manuf ; 11(2): e801-e811, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38689907

RESUMO

Laser powder bed fusion (LPBF) of complex-structure 316L stainless steel (316L ss) parts has a wide application prospects in aerospace, biomedical, and defense industry fields. However, the surface roughness (Ra) of the LPBF sample is unsatisfactory due to the process characteristics of layer-by-layer selective melting and cumulative forming, which limits its applications in the engineering field. Herein, a gradient voltage electrochemical polishing strategy is proposed based on the characteristics of electrochemical polishing technology, which can polish complex structures. The mechanisms of polishing process parameters and polishing strategy on the surface finish of LPBF parts are investigated. The gradient voltage polishing strategy is extended to complex structures, and the Ra of the inner surfaces of square and round tubes are successfully reduced to about 1 µm. The gradient electrochemical polishing process for surface finish post-treatment of LPBF parts can broaden the engineering applications of complex-structure metal parts.

7.
Front Bioeng Biotechnol ; 12: 1329960, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38665817

RESUMO

The current literature studied the median nerve (MN) at specific locations during joint motions. As only a few particular parts of the nerve are depicted, the relevant information available is limited. This experiment investigated the morphological and biomechanical properties of the MN. The effects of the shoulder and wrist motions on MN were explored as well. Eight young healthy female individuals were tested with two-dimensional ultrasound and shear wave elastography (SWE). The morphological and biomechanical properties were examined in limb position 1, with the wrist at the neutral position, the elbow extended at 180°, and the shoulder abducted at 60°. In addition, the experiment assessed the differences among the wrist, forearm, elbow, and upper arm with Friedman's test and Bonferroni post hoc analysis. Two groups of limb positions were designed to explore the effects of shoulder movements (shoulder abducted at 90° and 120°) and wrist movements (wrist extended at 45° and flexed at 45°) on the thickness and Young's modulus. Differences among the distributions of five limb positions were tested as well. The ICC3, 1 values for thickness and Young's modulus were 0.976 and 0.996, respectively. There were differences among the MN thicknesses of four arm locations in limb position 1, while Young's modulus was higher at the elbow and wrist than at the forearm and upper arm. Compared to limb position 1, only limb position 4 had an effect on MN thickness at the wrist. Both shoulder and wrist motions affected MN Young's modulus, and the stiffness variations at typical locations all showed a downward trend proximally in all. The distributions of MN thickness and Young's modulus showed fold line patterns but differed at the wrist and the pronator teres. The MN in the wrist is more susceptible to limb positions, and Young's modulus is sensitive to nerve changes and is more promising for the early diagnosis of neuropathy.

8.
Artigo em Inglês | MEDLINE | ID: mdl-38683719

RESUMO

To overcome the challenges posed by the complex structure and large parameter requirements of existing classification models, the authors propose an improved extreme learning machine (ELM) classifier for human locomotion intent recognition in this study, resulting in enhanced classification accuracy. The structure of the ELM algorithm is enhanced using the logistic regression (LR) algorithm, significantly reducing the number of hidden layer nodes. Hence, this algorithm can be adopted for real-time human locomotion intent recognition on portable devices with only 234 parameters to store. Additionally, a hybrid grey wolf optimization and slime mould algorithm (GWO-SMA) is proposed to optimize the hidden layer bias of the improved ELM classifier. Numerical results demonstrate that the proposed model successfully recognizes nine daily motion modes including low-, mid-, and fast-speed level ground walking, ramp ascent/descent, sit/stand, and stair ascent/descent. Specifically, it achieves 96.75% accuracy with 5-fold cross-validation while maintaining a real-time prediction time of only 2 ms. These promising findings highlight the potential of onboard real-time recognition of continuous locomotion modes based on our model for the high-level control of powered knee prostheses.


Assuntos
Algoritmos , Amputados , Intenção , Prótese do Joelho , Aprendizado de Máquina , Humanos , Amputados/reabilitação , Masculino , Modelos Logísticos , Locomoção/fisiologia , Caminhada , Fêmur , Reconhecimento Automatizado de Padrão/métodos , Adulto
9.
Nano Lett ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38592087

RESUMO

Electroactive artificial muscles with deformability have attracted widespread interest in the field of soft robotics. However, the design of artificial muscles with low-driven voltage and operational durability remains challenging. Herein, novel biomass porous carbon (BPC) electrodes are proposed. The nanoporous BPC enables the electrode to provide exposed active surfaces for charge transfer and unimpeded channels for ion migration, thus decreasing the driving voltage, enhancing time durability, and maintaining the actuation performances simultaneously. The proposed actuator exhibits a high displacement of 13.6 mm (bending strain of 0.54%) under 0.5 V and long-term durability of 99.3% retention after 550,000 cycles (∼13 days) without breaks. Further, the actuators are integrated to perform soft touch on a smartphone and demonstrated as bioinspired robots, including a bionic butterfly and a crawling robot (moving speed = 0.08 BL s-1). This strategy provides new insight into the design and fabrication of high-performance electroactive soft actuators with great application potential.

11.
Small ; : e2311588, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38497502

RESUMO

The multi-level structure is a strategy to enhance the mechanical properties of dung beetle leg joints. Under external loads, the microstructure facilitates energy dissipation and prevents crack extension. The macrostructure aids in transferring the load to more reliable parts. The connection established by the two hemispheres is present in the dung beetle leg joint. The micron-layered and nanoscale crystal structures further constitute the leg joint with excellent mechanical properties. The maximum compression fracture force is ≈101000 times the weight of the leg. Here, the structural design within the dung beetle leg joints and reveal the resulting mechanical response and enhancement mechanisms is determined. A series of beetle leg joints where the macrostructure and microstructure of the dung beetle leg provide mechanical strength at critical strains while avoiding catastrophic failure by transferring the load from the joint to the exoskeleton of the femur is highlighted. Nanocrystalline structures and fiber layers contribute to crack propagation of the exoskeleton. Based on this, the bionic joint with multi-level structures using resin and conducted a series of tests to verify their effectiveness is prepared. This study provides a new idea for designing and optimizing high-load joints in engineering.

12.
Nano Lett ; 24(10): 3186-3195, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38411393

RESUMO

Multisensory integration enables the simultaneous perception of multiple environmental stimuli while minimizing size and energy consumption. However, conventional multifunctional integration in flexible electronics typically requires large-scale horizontal sensing arrays (such as flexible printed circuit boards), posing decoupling complexities, tensile strain limitation, and spatial constraints. Herein, a fully flexible multimodal sensing system (FMSS) is developed by coupling biomimetic stretchable conductive films (BSCFs) and strain-insensitive communication interfaces using a vertical stacking integration strategy. The FMSS achieves vertical integration without additional adhesives, and it can incorporate individual sensing layers and stretchable interconnects without any essential constraint on their deformations. Accordingly, the temperature and pressure are precisely decoupled simultaneously, and tensile stress can be accurately discerned in different directions. This vertical stacking integration strategy is expected to offer a new approach to significantly streamline the design and fabrication of multimodal sensing systems and enhance their decoupling capabilities.

13.
Small ; 20(30): e2312037, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38409635

RESUMO

The flexible protective coatings and substrates frequently exhibit unstable bonding in industrial applications. For strong interfacial adhesion of heterogeneous materials and long-lasting adhesion of flexible protective coatings even in harsh corrosive environments. Inspired by the interdigitated structures in Phloeodes diabolicus elytra, a straightforward magnetic molding technique is employed to create an interlocking microarray for reinforced heterogeneous assembly. Benefiting from this bio-inspired microarrays, the interlocking polydimethylsiloxane (PDMS) coating recorded a 270% improvement in tensile adhesion and a 520% increase in shear resistance, approaching the tensile limitation of PDMS. The elastic polyurethane-polyamide (PUPI) coating equipped with interlocking structures demonstrated a robust adhesion strength exceeding 10.8 MPa and is nearly unaffected by the corrosion immersion. In sharp contrast, its unmodified counterpart exhibited low initial adhesion and maintain ≈20% of its adhesion strength after 30 d of immersion. PUPI coating integrated with microarrays exhibits superior resistance to corrosion (30 d, |Z|0.01HZ ≈1010 Ω cm2, Rct≈108 Ω cm2), cavitation and long-term adhesion retention. These interlocking designs can also be adapted to curved surfaces by 3D printing and enhances heterogeneous assembly of non-bonded materials like polyvinylidene fluoride (PTFE) and PDMS. This bio-inspired interlocking structures offers a solution for durably bonding incompatible interfaces across varied engineering applications.

14.
Adv Healthc Mater ; 13(10): e2302396, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38180708

RESUMO

Ti6Al4V scaffolds with pore sizes between 300 and 600 µm are deemed suitable for bone tissue engineering. However, a significant proportion of human bone pores are smaller than 300 µm, playing a crucial role in cell proliferation, differentiation, and bone regeneration. Ti6Al4V scaffolds with these small-sized pores are not successfully fabricated, and their cytocompatibility remains unknown. The study presents a novel ink formula specifically tailored for fabricating Ti6Al4V scaffolds featuring precise and unobstructed sub-300 µm structural pores, achieved by investigating the rheological properties and printability of five inks containing 60-77.5 vol% Ti6Al4V powders and bisolvent binders. Ti6Al4V scaffolds with 50-600 µm pores are fabricated via direct ink writing and subjected to in vitro assays with MC3T3-E1 and bone marrow mesenchymal stem cells. The 100 µm pore-sized scaffolds exhibit the highest cell adhesion and proliferation capacity based on live/dead assay, FITC-phalloidin/4',6-diamidino-2-phenylindole staining, and cell count kit 8 assay. The alizarin red staining, real-time quantitative PCR assay, and immunocytochemical staining demonstrate the superior osteogenic differentiation potential of 100 and 200 µm pore-sized scaffolds. The importance of sub-300 µm structrual pores is highlighted, redefining the optimal pore size for Ti6Al4V scaffolds and advancing bone tissue engineering and clinical medicine development.


Assuntos
Ligas , Osteogênese , Alicerces Teciduais , Titânio , Humanos , Alicerces Teciduais/química , Tinta , Engenharia Tecidual , Diferenciação Celular , Proliferação de Células , Porosidade
15.
Small ; 20(20): e2309012, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38178643

RESUMO

The self-healing ability of superhydrophobic surfaces in air has attracted tremendous additions in recent years. Once the superhydrophobic surface is damaged underwater, water seeps into gaps among micro/nano structures. The air film diffuses into water and eventually disappears during immersion without actively replenishing the gas, which results in the impossible of self-healing. Here, an underwater self-healing superhydrophobic coating with the synergetic effect of hydrogen bonds and self-formed bubbles via the spraying method is fabricated. The movement of hydrogen bonds of the prepared polyurethane enables microstructures to reconstruct at room temperature and self-formed bubbles of effervescent materials underwater actively replenish gas before microstructures completely self-healing, achieving the self-healing property of the superhydrophobic coating. Moreover, the hydrophilic effervescent material is sprayed along with unmodified micron-scaled particles because modified nano-scale particles are key factors for the realization of superhydrophobic coating. An underwater stable superhydrophobic surface with pressure resistance (4.9 kPa) is demonstrated. This superhydrophobic coating also shows excellent drag reduction, anti-icing, and anti-corrosion properties. This facile and scalable method offers a new route that an underwater self-healing superhydrophobic coating executes the gas film recovery.

16.
ACS Nano ; 18(3): 2520-2530, 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38197377

RESUMO

Stretchable flexible strain sensors based on conductive elastomers are rapidly emerging as a highly promising candidate for popular wearable flexible electronic and soft-mechanical sensing devices. However, due to the intrinsic limitations of low fidelity and high hysteresis, existing flexible strain sensors are unable to exploit their full application potential. Herein, a design strategy for a successive three-dimensional crack conductive network is proposed to cope with the uncoordinated variation of the output resistance signal arising from the conductive elastomer. The electrical characteristics of the sensor are dominated by the successive crack conductive network through a greater resistance variation and a concise sensing mechanism. As a result, the developed elastomer bionic strain sensors exhibit excellent sensing performance in terms of a smaller overshoot response, a lower hysteresis (∼2.9%), and an ultralow detection limit (0.00179%). What's more, the proposed strategy is universal and applicable to many conductive elastomers with different conductive fillers (including 0-D, 1-D, and 2-D conductive fillers). This approach improves the sensing signal accuracy and reliability of conductive elastomer strain sensors and holds promising potential for various applications in the fields of e-skin and soft robotic systems.

17.
Materials (Basel) ; 17(2)2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38276411

RESUMO

Osseointegration is the basic condition for orthopedic implants to maintain long-term stability. In order to achieve osseointegration, a low elastic modulus is the most important performance indicator. It is difficult for traditional titanium alloys to meet this requirement. A novel ß-titanium alloy (Ti-35Nb-7Zr-5Ta)98Si2 was designed, which had excellent strength (a yield strength of 1296 MPa and a breaking strength 3263 MPa), an extremely low elastic modulus (37 GPa), and did not contain toxic elements. In previous in vitro studies, we confirmed the good biocompatibility of this alloy and similar bioactivity to Ti-6Al-4V, but no in vivo study was performed. In this study, Ti-6Al-4V and (Ti-35Nb-7Zr-5Ta)98Si2 were implanted into rabbit femurs. Imaging evaluation and histological morphology were performed, and the bonding strength and bone contact ratio of the two alloys were measured and compared. The results showed that both alloys remained in their original positions 3 months after implantation, and neither imaging nor histological observations found inflammatory reactions in the surrounding bone. The bone-implant contact ratio and bonding strength of (Ti-35Nb-7Zr-5Ta)98Si2 were significantly higher than those of Ti-6Al-4V. The results confirmed that (Ti-35Nb-7Zr-5Ta)98Si2 has a better osseointegration ability than Ti-6Al-4V and is a promising material for orthopedic implants.

18.
ACS Biomater Sci Eng ; 10(1): 326-337, 2024 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-38147691

RESUMO

As potential degradable biomaterials, magnesium (Mg) alloys have development prospects in the field of orthopedic load-bearing, whereas the clinical application has encountered a bottleneck due to a series of problems caused by its rapid corrosion. In this study, strontium-substituted calcium phosphate (CaP) coatings with different structures were prepared on the surface of the Mg matrix by a simple one-step electrodeposition method at different temperatures, which enhanced the poor corrosion resistance of the Mg matrix. The coated sample prepared at 65 °C reduced the corrosion current density by 3 orders of magnitude and increased the impedance by nearly 2 orders of magnitude compared with bare Mg alloy, thanks to its dense fibrous structure similar to that of natural bones. Although the coating composition varies with different preparation temperatures, CaP, as an inorganic component similar to natural bone, has good cytocompatibility. Doping the right amount of strontium, which is a trace element in human bones, is beneficial to stimulate osteoblast differentiation, inhibit the activity of osteoclasts, and induce the formation of bone tissues. This provides a new option for modifying the Mg alloy with CaP coatings as a base.


Assuntos
Cálcio , Magnésio , Humanos , Cálcio/química , Magnésio/farmacologia , Magnésio/química , Corrosão , Materiais Revestidos Biocompatíveis/farmacologia , Materiais Revestidos Biocompatíveis/química , Temperatura , Galvanoplastia , Ligas/farmacologia , Ligas/química , Estrôncio/farmacologia , Fosfatos de Cálcio/farmacologia , Fosfatos de Cálcio/química
19.
Int J Biol Macromol ; 258(Pt 2): 128876, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38134987

RESUMO

Ultra-high molecular weight polyethylene (UHMWPE) fibers are broadly applied in lightweight and high-strength composite fiber materials. However, the development of UHMWPE fibers is limited by their smooth and chemically inert surfaces. To address the issues, a modified UHMWPE fibers material has been fabricated through the chelation reaction between Cu2+ and chitosan coatings within the surface of fibers after plasma treatment, which is inspired by the hardening mechanism, a crosslinked network between metal ions and proteins/polysaccharides of the tips and edges in arthropod-specific cuticular tools. The coatings improve the surface wettability and interfacial bonding ability, which are beneficial in extending the application range of UHMWPE fibers. More importantly, compared to the unmodified UHMWPE fiber cloths, the tensile property of the modified fiber cloths is increased by 18.89% without damaging the strength, which is infrequent in modified UHMWPE fibers. Furthermore, the interlaminar shear strength and fracture toughness of the modified fibers laminate are increased by 37.72% and 135.90%, respectively. These improvements can be attributed to the synergistic effects between the surface activity and the tiny bumps of the modified UHMWPE fibers. Hence, this work provides a more straightforward and less damaging idea of fiber modification for manufacturing desirable protective and medical materials.


Assuntos
Quitosana , Cobre , Teste de Materiais , Polietilenos/química
20.
Int. j. morphol ; 34(1): 63-70, Mar. 2016. ilus
Artigo em Inglês | LILACS | ID: lil-780476

RESUMO

The morphology of filiform papilla root in the tongue of Chinese yellow cattle were studied by scanning electron microscopy, and several geometric models were established to analyze the possible effects of such structures on lingual mechanical functions. Conical and tongue-like filiform papillae were detected in different locations on the lingual surface, along with six types of root structures. A lingual groove surrounded the papillae in five of these structures. To date, such grooves have not been discussed in studies on bovine lingual morphology, and those distributed on the dorsal surface of the lingual apex can limit the motion ranges of filiform papillae. Two secondary papillae emerged from a groove on the dorsal surface of the lingual apex's caudal half; these papillae can protect a filiform papilla root from damage. The grooves and the flat orientation of such papillae on the dorsal surface of the lingual body can reduce energy expenditure during forage transportation. A lingual rib that can strengthen the filiform papilla root emerged from a groove on the dorsal surface of the rostral half of the lingual body. On the dorsal surface of the lingual body's caudal half, all filiform papillae emerged from a groove to form low lingual walls that can protect the roots from being crushed by forage. High lingual walls were generated on the lateral surface of the lingual apex; these walls enable filiform papillae to adapt to harsh food environments effectively. The root structures on the lingual body's lateral surface were adequately simple and did not exhibit lingual grooves; thus, hydraulic resistance may decrease during mastication. Diverse root structures can optimize the lingual mechanical functions and improve self-protection capability in combination with the appearance and distributions of these papillae. All the aforementioned features may be the result of environmental adaption and cattle evolution.


La morfología de las papilas filiformes ubicadas en la raíz lingual del ganado amarillo chino fue estudiada mediante microscopía electrónica de barrido, estableciendo varios modelos geométricos para analizar los posibles efectos de estas estructuras sobre las funciones mecánicas linguales. Se detectaron papilas filiformes cónicas en diversas localizaciones de la superficie lingual, junto con seis tipos de estructuras en la raíz de la misma. Un surco lingual rodeado de las papilas se observó en cinco de estas estructuras. Hasta la fecha, dichos surcos no se han discutido en los estudios sobre la morfología lingual bovina, y aquellas distribuidas en la superficie dorsal de la cúspide lingual pueden limitar los rangos de movimientos en las papilas filiformes. Dos papilas secundarias surgieron de una ranura en la superficie dorsal de la mitad caudal de la cúspide lingual; estas papilas pueden proteger de los daños a una papila filiforme. Las ranuras y la orientación plana de tales papilas en la superficie dorsal del cuerpo lingual pueden reducir el gasto de energía durante el transporte de forraje. Un nervio lingual que puede fortalecer la raíz y las papilas filiformes se observó en una de las ranuras en la superficie dorsal, de la mitad rostral del cuerpo lingual. En la superficie dorsal de la mitad caudal del cuerpo lingual, todas las papilas filiformes generaron una ranura para formar un tipo de paredes linguales que pueden proteger las raíces. Las paredes linguales altas se generaron en la superficie lateral del ápice lingual; estas paredes permiten que las papilas filiformes se adapten a entornos inhóspitos de alimentos. Las estructuras de la raíz en la superficie lateral del cuerpo lingual fueron simples y no mostraron surcos linguales, lo que puede disminuir la resistencia hidráulica durante la masticación. Diversas estructuras de la raíz pueden optimizar las funciones mecánicas linguales y mejorar la capacidad de autoprotección en combinación con el aspecto y las distribuciones de estas papilas. Todas las características antes mencionadas pueden ser el resultado de la adaptación ambiental y la evolución de ganado.


Assuntos
Animais , Masculino , Feminino , Bovinos/anatomia & histologia , Língua/ultraestrutura , Microscopia Eletrônica de Varredura , Língua/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA