Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Langenbecks Arch Surg ; 407(7): 3113-3122, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35906300

RESUMO

INTRODUCTION: SyngoDynaPBVNeuro® is a tool to perform cerebral blood volume (CBV) measurements intraoperatively by functional imaging producing CT-like images. Aim of this prospective study was to analyze the clinical relevance and benefit of CBV measurement with regard to neurological complications like cerebral hyperfusion syndrome (CHS). METHODS: Forty-five patients undergoing endarterectomy (CEA) of the internal carotid artery were included; functional imaging with CBV measurement was performed before and after CEA. To evaluate and analyze CBV, six regions of interest (ROI) were identified for all patients with an additional ROI in patients with symptomatic ICA stenosis and previous stroke. The primary endpoint of the study was a perioperative change in CBV measurements. Secondary outcomes were incidence of stroke, TIA, CHS, and perioperative morbidity and mortality. RESULTS: Thirty-day stroke incidence and thirty-day mortality were 0%. Thirty-day morbidity was 6.7%. Two patients from the asymptomatic group suffered from transient neurological symptoms without signs of intracerebral infarction in CT or MR scan, meeting diagnostic criteria for CHS. In 83.3% of ROIs in these patients, an increase of blood volume was detected. Overall, 26.7% patients suffered from unilateral headache as expression of potential CHS. A total of 69.4% of ROIs in patients with postoperative unilateral headache showed an increase when comparing pre- and postoperative CBV measurements. CONCLUSION: The results show that increased CBV measured by functional imaging is a possible surrogate marker of neurological complications like CHS after CEA. By using intraoperative CBV measurement, the risk of CHS can be estimated early and appropriate therapeutic measures can be applied.


Assuntos
Estenose das Carótidas , Endarterectomia das Carótidas , Acidente Vascular Cerebral , Humanos , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas/efeitos adversos , Cefaleia , Estudos Prospectivos , Síndrome
2.
Eur J Vasc Endovasc Surg ; 54(3): 324-330, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28716447

RESUMO

OBJECTIVE: Retrograde aortic type A dissection (RTAD) is a known complication in patients with aortic type B dissection. The purpose of this computational fluid dynamics (CFD) study was to identify haemodynamic risk factors for the occurrence of RTAD. METHODS: Computed tomographic angiography (CTA) images of 10 patients with type B dissections, who subsequently developed a RTAD, were retrospectively analysed together with patients constituting a control group (n = 10) where no further vascular events after the initial type B dissection occurred. CFD simulations were conducted based on 3D surface models of the aortic lumen derived from CTA datasets. For both groups, pressures, velocity magnitudes and wall shear stress (WSS) were compared at the site of the future RTAD entry tear and the surrounding aortic wall. RESULTS: WSS at the site of the future entry tear was significantly elevated compared with the surrounding wall (15.10 Pa vs. 5.15 Pa, p < .001) and was significantly higher in the RTAD group than in the control group (6.05 Pa, p < .002). Pressures and velocity magnitudes were not significantly elevated at the entry tear (3825.8 Pa, 0.63 m/s) compared with the aortic arch (3549.8 Pa, 0.50 m/s) or control group (3501.7 Pa, 0.62 m/s). CONCLUSIONS: Increased WSS accompanies the occurrence of RTAD. The results merit the design for a prospective study to confirm whether WSS is a risk factor for the occurrence of RTAD.


Assuntos
Aorta/fisiopatologia , Aneurisma Aórtico/fisiopatologia , Dissecção Aórtica/fisiopatologia , Hemodinâmica , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Dissecção Aórtica/diagnóstico por imagem , Aorta/diagnóstico por imagem , Aneurisma Aórtico/diagnóstico por imagem , Aortografia/métodos , Velocidade do Fluxo Sanguíneo , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Hidrodinâmica , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Interpretação de Imagem Radiográfica Assistida por Computador , Fluxo Sanguíneo Regional , Estudos Retrospectivos , Fatores de Risco , Estresse Mecânico
3.
Eur J Vasc Endovasc Surg ; 45(3): 241-7, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23318135

RESUMO

OBJECTIVES: This study aims to test whether inter-observer variability and time of diameter measurements for thoracic endovascular aortic repair (TEVAR) are improved by semiautomatic centerline analysis compared to manual assessment. METHODS: Preoperative computed tomography (CT) angiographies of 30 patients with thoracic aortic disease (mean age 66.8 ± 11.6 years, 23 males) were retrospectively analysed by two blinded experts in vascular radiology. Maximum aortic diameters at three positions relevant to TEVAR were assessed (P1, distal to left common carotid artery; P2, distal to left subclavian artery; and P3, proximal to coeliac trunk) using three measurement techniques: manual axial slices (axial), manual double-oblique multiplanar reformations (MPRs) and semiautomatic centerline analysis. RESULTS: Diameter measurements by both centerline analysis and the axial technique did not significantly differ from MPR (p = 0.17 and p = 0.37). Total deviation index for 0.9 was for P1 2.7 mm (axial), 3.7 mm (MPR), 1.8 mm (centerline); for P2 2.0 mm (axial), 3.6 mm (MPR), 1.8 mm (centerline); and for P3 3.0 mm (axial), 3.5 mm (MPR), 2.5 mm (centerline). Measurement time using centerline analysis was significantly shorter than for assessment by MPR. CONCLUSIONS: Centerline analysis provides the least variable and fast diameter measurements in TEVAR patients with the same accuracy as the current reference standard MPR.


Assuntos
Angiografia/métodos , Aorta Torácica/diagnóstico por imagem , Precisão da Medição Dimensional , Imageamento Tridimensional/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Aorta Torácica/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
4.
AJNR Am J Neuroradiol ; 33(11): 2151-7, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22595902

RESUMO

BACKGROUND AND PURPOSE: Brain tumors affecting language-relevant areas may influence language lateralization. The purpose of this study was to systematically investigate language lateralization in brain tumor patients using clinical language fMRI, comparing the results with a group of healthy volunteers. MATERIALS AND METHODS: Fifty-seven strictly right-handed patients with left-hemispheric-space intracranial masses (mainly neoplastic) affecting either the Broca area (n = 19) or Wernicke area (n = 38) were prospectively enrolled in this study. Fourteen healthy volunteers served as a control group. Standardized clinical language fMRI, using visually triggered sentence- and word-generation paradigms, was performed on a 1.5T MR scanner. Semiautomated analyses of all functional data were conducted on an individual basis using BrainVoyager. A regional lateralization index was calculated for Broca and Wernicke areas separately versus their corresponding right-hemisphere homologs. RESULTS: In masses affecting the Broca area, a significant decrease in the lateralization index was found when performing word generation (P = .0017), whereas when applying sentence generation, the decrease did not reach statistical significance (P = .851). Masses affecting the Wernicke area induced a significant decrease of the lateralization index when performing sentence generation (P = .0007), whereas when applying word generation, the decrease was not statistically significant (P = .310). CONCLUSIONS: Clinical language fMRI was feasible for patients with brain tumors and provided relevant presurgical information by localizing essential language areas and determining language dominance. A significant effect of the brain masses on language lateralization was observed, with a shift toward the contralesional, nondominant hemisphere. This may reflect compensatory mechanisms of the brain to maintain communicative abilities.


Assuntos
Mapeamento Encefálico/métodos , Neoplasias Encefálicas/fisiopatologia , Encéfalo/fisiopatologia , Idioma , Imageamento por Ressonância Magnética/métodos , Rede Nervosa/fisiopatologia , Adulto , Encéfalo/patologia , Mapeamento Encefálico/normas , Neoplasias Encefálicas/patologia , Feminino , Lateralidade Funcional , Humanos , Imageamento por Ressonância Magnética/normas , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Vasa ; 40(4): 315-9, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21780056

RESUMO

BACKGROUND: Deep venous thrombosis is mainly diagnosed by ultrasound today. In some instances diagnosis is challenging and magnetic resonance angiography could be an attractive alternative. Gadofosveset is a blood pool contrast agent with some favourable properties for this purpose. PATIENTS AND METHODS: We investigated eight patients with proven deep venous thrombosis by Gadofosveset enhanced MR phlebography. We performed a 3D gradient-echo sequence with an overall measurement time of 9 minutes and 6 seconds. One minute after injection of Gadofosveset in a concentration of 0.12 ml/kg body weight images were acquired. Thrombi were visualised by their lack of luminal contrast filling. RESULTS: Thrombi were visualised in all patients. In one patient with extended thrombosis a previously undiagnosed ovarian adenocarcinoma was detected additionally. CONCLUSIONS: Deep venous thromboses in lower extremities can be visualised reliably by performing MR phlebography with blood pool contrast agent Gadofosveset. Visualisation of the complete venous system is feasible. This investigation method may be performed in patients difficult to investigate with ultrasound or may be used for planning interventional procedures.


Assuntos
Meios de Contraste , Gadolínio , Extremidade Inferior/irrigação sanguínea , Angiografia por Ressonância Magnética , Compostos Organometálicos , Pelve/irrigação sanguínea , Flebografia/métodos , Trombose Venosa/diagnóstico , Adenocarcinoma/complicações , Adenocarcinoma/diagnóstico , Adulto , Idoso , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Neoplasias Ovarianas/complicações , Neoplasias Ovarianas/diagnóstico , Valor Preditivo dos Testes , Suíça , Ultrassonografia Doppler Dupla , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/etiologia
6.
Eur J Vasc Endovasc Surg ; 42(3): 324-31, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21570879

RESUMO

OBJECTIVES: The study aimed to test whether reliability and inter-observer variability of preoperative measurements for thoracic endovascular aortic repair (TEVAR) among non-experts are improved by semiautomatic centerline analysis compared with manual assessment. METHODS: Preoperative computed tomography (CT) angiographies of 30 patients with thoracic aortic disease (mean age 66.8 ± 11.6 years, 23 men) were retrospectively analysed in randomised order by one blinded vascular expert (reference standard) and three blinded non-expert readers. Aortic diameters were measured at four positions relevant to TEVAR using three measurement techniques (manual axial slices, manual multiplanar reformations (MPRs) and semiautomatic centerline analysis). Length measurements were performed using centerline analysis. Reliability was calculated as absolute measurement deviation (AMD) from reference standard and inter-observer variability as coefficient of variance (CV) among non-expert readers. RESULTS: For axial, MPR and centerline techniques, mean AMD was 7.3 ± 7.7%, 6.7 ± 4.5% and 4.7 ± 4.8% and mean CV was 5.2 ± 4.2%, 5.8 ± 4.8% and 3.9 ± 5.4%. Both AMD and CV were significantly lower for centerline analysis compared with axial technique (p = 0.001/0.042) and MPR (p = 0.009/0.003). AMD and CV for length measurements by centerline analysis were 3.2 ± 2.8% and 2.6 ± 2.4%, respectively. Centerline analysis was significantly faster than MPR (p < 0.001). CONCLUSIONS: Semiautomatic centerline analysis provides the most reliable and least variable diameter and length measurements among non-experts in candidates for TEVAR.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/cirurgia , Procedimentos Endovasculares/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia , Aorta , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/patologia , Pesos e Medidas Corporais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
7.
Int J Comput Assist Radiol Surg ; 5(4): 335-41, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20467825

RESUMO

PURPOSE: Generation of graspable three-dimensional objects applied for surgical planning, prosthetics and related applications using 3D printing or rapid prototyping is summarized and evaluated. MATERIALS AND METHODS: Graspable 3D objects overcome the limitations of 3D visualizations which can only be displayed on flat screens. 3D objects can be produced based on CT or MRI volumetric medical images. Using dedicated post-processing algorithms, a spatial model can be extracted from image data sets and exported to machine-readable data. That spatial model data is utilized by special printers for generating the final rapid prototype model. RESULTS: Patient-clinician interaction, surgical training, medical research and education may require graspable 3D objects. The limitations of rapid prototyping include cost and complexity, as well as the need for specialized equipment and consumables such as photoresist resins. CONCLUSIONS: Medical application of rapid prototyping is feasible for specialized surgical planning and prosthetics applications and has significant potential for development of new medical applications.


Assuntos
Desenho Assistido por Computador , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Planejamento de Assistência ao Paciente , Desenho de Prótese , Cirurgia Assistida por Computador/métodos , Algoritmos , Humanos , Imageamento por Ressonância Magnética , Modelos Anatômicos , Tomografia Computadorizada por Raios X
8.
Acta Radiol ; 50(8): 909-13, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19639472

RESUMO

Recent advances in flow-sensitive magnetic resonance imaging (MRI) and data analysis allow for comprehensive noninvasive three-dimensional (3D) visualization of complex blood flow. Electrocardiogram (ECG)-gated three-directional (3dir) flow measurements were employed to assess and visualize time-resolved 3D blood flow in the pulmonary arteries (PA) and thoracic aorta. We present findings in a juvenile patient with surgically corrected transposition of the great arteries (d-TGA) and aortic coarctation. For the first time, the complex flow patterns in the PA following d-TGA were visualized. Morphologically, a slight asymmetry of the PA was found, with considerable impact on vascular hemodynamics, resulting in diastolic retrograde flow in the larger vessel and diastolic filling of the smaller PA. Additionally, increased flow to the supraaortic vessels was found due to aortic coarctation.


Assuntos
Imagem Cinética por Ressonância Magnética/métodos , Transposição dos Grandes Vasos/fisiopatologia , Adolescente , Aorta Torácica/fisiopatologia , Velocidade do Fluxo Sanguíneo , Eletrocardiografia , Humanos , Imageamento Tridimensional , Masculino , Artéria Pulmonar/fisiopatologia , Transposição dos Grandes Vasos/cirurgia
9.
J Cardiovasc Surg (Torino) ; 49(4): 429-47, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18665106

RESUMO

Almost 50 years after its introduction intra-arterial digital subtraction angiography (DSA) has been passed as the gold standard for diagnostic imaging of the aorta. Today's performance of multi-detector-row computed tomography angiography (CTA) as well as magnetic resonance imaging (MRI) and magnetic resonance angiography (MRA) offer remarkable improvements in the field of diagnostic cardiovascular imaging. The racy developments not only concerning image acquisition but also image postprocessing offer a multidimensional approach to assess anatomy and pathology of individual patients in a few minutes. Four-dimensional visualization assists us to select the ''adequate'' patient, quantify vascular and adjacent geometries, and select the appropriate device to realize even complex thoracic endovascular aortic reconstructions (TEVAR). There is still a discrepancy between perioperative and intraoperative imaging--but new technologies made also some progress in this field. Lifelong imaging surveillance of TEVAR and bypasses is still a critical component of patient care and requires comparable imaging and postprocessing capabilities as for the preoperative setting. Although is the most commonly used examination for imaging surveillance, MRA, chest x-ray and DSA all have their role in determining complications and their management.


Assuntos
Aorta Torácica/patologia , Aortografia/métodos , Angiografia por Ressonância Magnética , Tomografia Computadorizada por Raios X , Angiografia Digital , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Humanos , Interpretação de Imagem Assistida por Computador , Cuidados Pós-Operatórios , Cuidados Pré-Operatórios , Procedimentos Cirúrgicos Vasculares
10.
Radiologe ; 47(11): 1003-11, 2007 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-17943264

RESUMO

Multiplanar reformation (MPR) is the most relevant tool for patient selection and precise procedural planning and also for analyzing postinterventional complications. Curved MPR is used primarily for semiautomated or completely automated calculation of the centerline of the vascular lumen and to estimate the orthogonal vessel diameter and longitudinal extent. Reproducible and accurate measurement of complex pathologies and courses of vessels extends the range of diagnostic radiology. Contemporary scanner consoles allow automated processing of maximum intensity projections (MIP) and standard MPR and their storage in PACS. To improve patient selection, procedural planning, root-cause analysis postoperatively for assessment of treatment effects and to make better communication of findings to nonradiologists possible, volume rendering techniques (VRT) are a beneficial adjunct to source images. With current algorithms semiautomated segmentation is satisfactory for vessels and bones, but not for low-contrast structures (soft tissues), which still need to be segmented manually. In general, isotropic CT source data are preferable to MR images, which are often anisotropic. In many European countries image postprocessing is still not adequately reimbursed although the doctors making referrals often specifically and emphatically demand 3D visualization and measurements in daily practice.


Assuntos
Doenças da Aorta/diagnóstico , Aortografia/métodos , Processamento de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/cirurgia , Implante de Prótese Vascular , Meios de Contraste , Feminino , Hematoma/diagnóstico , Hematoma/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Masculino , Síndrome de Marfan/diagnóstico por imagem , Sistemas de Informação em Radiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA