Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 104
Filtrar
1.
Lancet ; 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38795719

RESUMO

BACKGROUND: Transcatheter aortic valve implantation is an established, guideline-endorsed treatment for severe aortic stenosis. Precise sizing of the balloon-expandable Myval transcatheter heart valve (THV) series with the aortic annulus is facilitated by increasing its diameter in 1·5 mm increments, compared with the usual 3 mm increments in valve size. The LANDMARK trial aimed to show non-inferiority of the Myval THV series compared with the contemporary THVs Sapien Series (Edwards Lifesciences, Irvine, CA, USA) or Evolut Series (Medtronic, Minneapolis, MN, USA). METHODS: In this prospective, multinational, randomised, open-label, non-inferiority trial across 31 hospitals in 16 countries (Germany, France, Sweden, the Netherlands, Italy, Spain, New Zealand, Portugal, Greece, Hungary, Poland, Slovakia, Slovenia, Croatia, Estonia, and Brazil), 768 participants with severe symptomatic native aortic stenosis were randomly assigned (1:1) to the Myval THV or a contemporary THV. Eligibility was primarily decided by the heart team in accordance with 2021 European Society of Cardiology guidelines. As per the criteria of the third Valve Academic Research Consortium, the primary endpoint at 30 days was a composite of all-cause mortality, all stroke, bleeding (types 3 and 4), acute kidney injury (stages 2-4), major vascular complications, moderate or severe prosthetic valve regurgitation, and conduction system disturbances resulting in a permanent pacemaker implantation. Non-inferiority of the study device was tested in the intention-to-treat population using a non-inferiority margin of 10·44% and assuming an event rate of 26·10%. This trial is registered with ClinicalTrials.gov, NCT04275726, and EudraCT, 2020-000137-40, and is closed to new participants. FINDINGS: Between Jan 6, 2021, and Dec 5, 2023, 768 participants with severe symptomatic native aortic stenosis were randomly assigned, 384 to the Myval THV and 384 to a contemporary THV. 369 (48%) participants had their sex recorded as female, and 399 (52%) as male. The mean age of participants was 80·0 years (SD 5·7) for those treated with the Myval THV and 80·4 years (5·4) for those treated with a contemporary THV. Median Society of Thoracic Surgeons scores were the same in both groups (Myval 2·6% [IQR 1·7-4·0] vs contemporary 2·6% [1·7-4·0]). The primary endpoint showed non-inferiority of the Myval (25%) compared with contemporary THV (27%), with a risk difference of -2·3% (one-sided upper 95% CI 3·8, pnon-inferiority<0·0001). No significant difference was seen in individual components of the primary composite endpoint. INTERPRETATION: In individuals with severe symptomatic native aortic stenosis, the Myval THV met its primary endpoint at 30 days. FUNDING: Meril Life Sciences.

2.
JACC Cardiovasc Interv ; 17(11): 1311-1321, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38795093

RESUMO

BACKGROUND: Left atrial appendage occlusion (LAAO) provides mechanical cardioembolic protection for atrial fibrillation (AF) patients who cannot use oral anticoagulation therapy (OAT). Patients with a thrombotic event despite OAT are at high risk for recurrence and may also benefit from LAAO. OBJECTIVES: This study sought to investigate the efficacy of LAAO in AF patients with a thrombotic event on OAT compared to: 1) LAAO in AF patients with a contraindication for OAT; and 2) historical data. METHODS: The international LAAO after stroke despite oral anticoagulation (STR-OAC LAAO) collaboration included patients who underwent LAAO because of thrombotic events on OAT. This cohort underwent propensity score matching and was compared to the EWOLUTION (Evaluating Real-Life Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology) registry, which represents patients who underwent LAAO because of OAT contraindications. The primary outcome was ischemic stroke. Event rates were compared between cohorts and with historical data without OAT, yielding relative risk reductions based on risk scores. RESULTS: Analysis of 438 matched pairs revealed no significant difference in the ischemic stroke rate between the STR-OAC LAAO and EWOLUTION cohorts (2.5% vs 1.9%; HR: 1.37; 95% CI: 0.72-2.61). STR-OAC LAAO patients exhibited a higher thromboembolic risk (HR: 1.71; 95% CI: 1.04-2.83) but lower bleeding risk (HR: 0.39; 95% CI: 0.18-0.88) compared to EWOLUTION patients. The mortality rate was slightly higher in EWOLUTION (4.3% vs 6.9%; log-rank P = 0.028). Relative risk reductions for ischemic stroke were 70% and 78% in STR-OAC LAAO and EWOLUTION, respectively, compared to historical data without OAT. CONCLUSIONS: LAAO in patients with a thrombotic event on OAT demonstrated comparable stroke rates to the OAT contraindicated population in EWOLUTION. The thromboembolic event rate was higher and the bleeding rate lower, reflecting the intrinsically different risk profile of both populations. Until randomized trials are available, LAAO may be considered in patients with an ischemic event on OAT.


Assuntos
Anticoagulantes , Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Contraindicações de Medicamentos , AVC Isquêmico , Sistema de Registros , Humanos , Apêndice Atrial/fisiopatologia , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/complicações , Fibrilação Atrial/mortalidade , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/terapia , Feminino , Masculino , Anticoagulantes/efeitos adversos , Anticoagulantes/administração & dosagem , Idoso , Fatores de Risco , Medição de Risco , Idoso de 80 Anos ou mais , Fatores de Tempo , Administração Oral , AVC Isquêmico/prevenção & controle , AVC Isquêmico/mortalidade , AVC Isquêmico/diagnóstico , AVC Isquêmico/etiologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Falha de Tratamento , Hemorragia/induzido quimicamente , Recidiva , Pessoa de Meia-Idade , Estudos Retrospectivos , Europa (Continente)
3.
Clin Res Cardiol ; 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38619575

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) serves a growing range of patients with severe aortic stenosis (AS). TAVI has evolved to a streamlined procedure minimizing length of hospital stay. AIMS: To evaluate the safety and efficacy of an early discharge (ED) strategy after TAVI. METHODS: We performed an international, multi-center, prospective observational single-arm study in AS patients undergoing TAVI with the ACURATE valve platform. Eligibility for ED was assessed prior to TAVI and based on prespecified selection criteria. Discharge ≤ 48 h was defined as ED. Primary Valve Academic Research Consortium (VARC)-3-defined 30-day safety and efficacy composite endpoints were landmarked at 48 h and compared between ED and non-ED groups. RESULTS: A total of 252 patients were included. The median age was 82 [25th-75th percentile, 78-85] years and the median Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) score was 2.2% [25th-75th percentile, 1.6-3.3]. ED and non-ED were achieved in 173 (69%) and 79 (31%) patients respectively. Monitoring for conduction disturbances was the principal reason for non-ED (33%). Overall, at 30 days, all-cause mortality was 1%, new permanent pacemaker rate was 4%, and valve- or procedure-related rehospitalization was 4%. There was no difference in the primary safety and efficacy endpoint between the ED and non-ED cohorts (OR 0.84 [25th-75th percentile, 0.31-2.26], p = 0.73, and OR 0.97 [25th-75th percentile, 0.46-2.06], p = 0.94). The need for rehospitalization was similarly low for ED and non-ED groups. CONCLUSION: Early discharge after TAVI with the ACURATE valve is safe and feasible in selected patients. Rhythm monitoring and extended clinical observation protracted hospital stay.

4.
Am Heart J ; 269: 158-166, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38163616

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established treatment option for patients with severe aortic valve stenosis, but is still associated with relatively high rates of pacemaker implantation and paravalvular regurgitation. Routine preoperative computed tomography (CT) combined with patient-specific computer modelling can predict the interaction between the TAVI device and the patient's unique anatomy, allowing physicians to assess the risk for paravalvular regurgitation and conduction disorders in advance to the procedure. The aim of this trial is to assess potential improvement in the procedural outcome of TAVI by applying CT-based patient-specific computer simulations in patients with suitable anatomy for TAVI. METHODS: The GUIDE-TAVI trial is an international multicenter randomized controlled trial including patients accepted for TAVI by the Heart Team. Patients enrolled in the study will be randomized into 2 arms of each 227 patients. In patients randomized to the use of FEops HEARTGuide (FHG), patient-specific computer simulation with FHG is performed in addition to routine preoperative CT imaging and results of the FHG are available to the operator(s) prior to the scheduled intervention. In patients randomized to no use of FHG, only routine preoperative CT imaging is performed. The primary objective is to evaluate whether the use of FHG will reduce the incidence of mild to severe PVR, according to the Valve Academic Research Consortium 3. Secondary endpoints include the incidence of new conduction disorders requiring permanent pacemaker implantation, the difference between preoperative and final selected valve size, the difference between target and final implantation depth, change of preoperative decision, failure to implant valve, early safety composite endpoint and quality of life. CONCLUSIONS: The GUIDE-TAVI trial is the first multicenter randomized controlled trial to evaluate the value of 3-dimensional computer simulations in addition to standard preprocedural planning in TAVI procedures.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Simulação por Computador , Qualidade de Vida , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Tomografia Computadorizada por Raios X/efeitos adversos , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos
5.
EuroIntervention ; 19(9): 766-771, 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-37605804

RESUMO

About one-third of patients undergoing transcatheter aortic valve implantation (TAVI) use oral anticoagulants (OAC), mainly due to atrial fibrillation. General guidelines advise interrupting OAC in patients with a high risk of bleeding undergoing interventions. However, preliminary observational data suggest that the continuation of OAC during TAVI is safe and may reduce the risk of periprocedural thromboembolic events. The Periprocedural Continuation Versus Interruption of Oral Anticoagulant Drugs During Transcatheter Aortic Valve Implantation (POPular PAUSE TAVI) is a multicentre, randomised clinical trial with open-label treatment and blinded endpoint assessment. Patients are randomised 1:1 to periprocedural continuation versus interruption of OAC and are stratified for vitamin K antagonist or direct oral anticoagulant use. The primary endpoint is a composite of cardiovascular mortality, all stroke, myocardial infarction, major vascular complications and type 2-4 bleeding within 30 days after TAVI, according to the Valve Academic Research Consortium-3 criteria. Secondary endpoints include separate individual and composite outcomes, quality of life and cost-effectiveness. Since continuation of OAC is associated with the ancillary benefit that it simplifies periprocedural management, the primary outcome is first analysed for non-inferiority; if non-inferiority is proven, superiority will be tested. Recruitment started in November 2020, and the trial will continue until a total of 858 patients have been included and followed for 90 days. In summary, POPular PAUSE TAVI is the first randomised clinical trial to assess the safety and efficacy of periprocedural continuation versus interruption of OAC in patients undergoing TAVI.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Qualidade de Vida , Anticoagulantes/uso terapêutico , Hemorragia , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
6.
Heart Rhythm O2 ; 4(5): 298-308, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37323993

RESUMO

Background: Percutaneous left atrial appendage occlusion (LAAO) is an alternative to anticoagulation in the prevention of stroke in patients with nonvalvular atrial fibrillation, especially in patients with a contraindication for oral anticoagulation therapy (OAT). Objective: The study sought to obtain long-term patient outcomes after successful LAAO in everyday clinical practice. Methods: In this single-center registry spanning over 10 years, data of all consecutive patients that underwent percutaneous LAAO were collected. Observed thromboembolic and major bleeding event rates after successful LAAO during follow-up were compared with expected event rates based on CHA2DS2-VASc (congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age 65-74 years, sex category) and HAS-BLED (hypertension, abnormal renal or liver function, stroke, bleeding, labile international normalized ratio, elderly, drugs or alcohol) scores. Furthermore, anticoagulation and antiplatelet use during follow-up was evaluated. Results: Of 230 patients scheduled for LAAO (38% women, 69.5 ± 8.2 years of age, CHA2DS2-VASc score 3.9 ± 1.6, HAS-BLED score 2.9 ± 1.0), 218 patients had a successful implantation (95%) with a follow-up duration of 5.2 ± 3.1 years. The procedure was combined with catheter ablation in 52% of the patients. Fifty thromboembolic complications (24 ischemic stroke, 26 transient ischemic attack) were observed during follow-up in 40 (18%) of 218 patients. Ischemic strokes occurred with a rate of 2.1 per 100 patient-years, accounting for a 66% relative risk reduction compared with the CHA2DS2-VASc predicted event rate. Device-related thrombus was observed in 5 (2%) patients. Sixty-five nonprocedural major bleeding complications occurred in 24 (11%) of 218 patients with a rate of 5.7 per 100-patient years, which is comparable to estimated HAS-BLED-bleeding rates under OAT use. At end of follow-up 71% of all patients were on single antiplatelet or no antiplatelet or anticoagulation treatment, while 29% were on OAT. Conclusion: Thromboembolic event rates during long-term follow-up after successful LAAO remained consistently lower than expected supporting the efficacy of LAAO.

7.
JACC Cardiovasc Interv ; 15(11): 1140-1149, 2022 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-35680194

RESUMO

BACKGROUND: The work-up for transcatheter aortic valve replacement (TAVR) currently uses computed tomography to evaluate the annulus diameter and peripheral vascular access plus invasive coronary angiography (ICA) to assess significant coronary artery disease (CAD). ICA might partially be redundant with the use of coronary computed tomography angiography (CCTA). Prior studies found an improvement of the diagnostic accuracy of CCTA with the use of computed tomography-derived fractional flow reserve (CT-FFR). OBJECTIVES: The aim of this study was to assess the diagnostic performance of CT-FFR for the diagnosis of CAD in the work-up for TAVR. METHODS: Consecutive patients with severe symptomatic aortic valve stenosis who underwent TAVR work-up between 2015 and 2019 were included in this retrospective cross-sectional study. All patients underwent CCTA and ICA within 3 months, and the diagnostic performance of both CCTA and CT-FFR was assessed using ICA as the reference. RESULTS: Seventy-six of the 338 patients included in the analysis had ≥1 significant coronary stenosis on ICA. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy per patient were 76.9%, 64.5%, 34.0%, 92.1%, and 66.9% for CCTA and 84.6%, 88.3%, 63.2%, 96.0%, and 87.6% for CT-FFR. The area under the receiver-operating characteristic curve was significantly different between CCTA and CT-FFR (0.84 vs 0.90, P = 0.02). A CT-FFR-guided approach could avoid ICA in 57.1% versus 43.6% of patients using CCTA. CONCLUSIONS: CT-FFR significantly improves the diagnostic accuracy of CCTA without additional testing and increases the proportion of patients in whom ICA could have been safely avoided. It has the potential to be integrated in the current clinical work-up for TAVR for diagnosing stable CAD requiring treatment.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Substituição da Valva Aórtica Transcateter , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Estudos Transversais , Humanos , Valor Preditivo dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
Cardiovasc Revasc Med ; 44: 71-77, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35739011

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is now an established treatment strategy for elderly patients with symptomatic aortic stenosis (AS) across the entire operative risk spectrum. Streamlined TAVR protocols along with reduced procedure time and expedited ambulation promote early hospital discharge. Selection of patients suitable for safe early discharge after TAVR might improve healthcare efficiency. STUDY DESIGN: The POLESTAR trial is an international, multi-center, prospective, observational study which aims to evaluate the safety of early discharge in selected patients who undergo TAVR with the supra-annular functioning self-expanding ACURATE Neo transcatheter heart valve (THV). A total of 250 patients will be included based on a set of baseline criteria indicating potential early discharge (within 48 h post-TAVR). Primary study endpoints include Valve Academic Research Consortium (VARC)-3 defined safety at 30 days and VARC-3 defined efficacy at 30 days and 1 year. Endpoints will be compared between early discharge and non-early discharge cohorts with a distinct landmark analysis at 48 h post-TAVR. Secondary endpoints include quality of life assessed using EQ5D-5L and Kansas City Cardiomyopathy Questionnaire (KCCQ) questionnaires and resource costs compared between discharge groups. SUMMARY: The POLESTAR trial prospectively evaluates safety and feasibility of an early discharge protocol for TAVR using the ACURATE Neo THV.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Qualidade de Vida , Estudos Prospectivos , Alta do Paciente , Desenho de Prótese , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Risco
11.
Sci Rep ; 11(1): 6425, 2021 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-33742077

RESUMO

Invasive fractional flow reserve (FFR) adoption remains low mainly due to procedural and operator related factors as well as costs. Alternatively, quantitative flow ratio (QFR) achieves a high accuracy mainly outside the intermediate zone without the need for hyperaemia and wire-use. We aimed to determine the diagnostic performance of QFR and to evaluate a QFR-FFR hybrid strategy in which FFR is measured only in the intermediate zone. This retrospective study included 289 consecutive patients who underwent invasive coronary angiography and FFR. QFR was calculated for all vessels in which FFR was measured. The QFR-FFR hybrid approach was modelled using the intermediate zone of 0.77-0.87 in which FFR-measurements are recommended. The sensitivity, specificity, and accuracy on a per vessel-based analysis were 84.6%, 86.3% and 85.6% for QFR and 88.0%, 92.9% and 90.3% for the QFR-FFR hybrid approach. The diagnostic accuracy of QFR-FFR hybrid strategy with invasive FFR measurement was 93.4% and resulted in a 56.7% reduction in the need for FFR. QFR has a good correlation and agreement with invasive FFR. A hybrid QFR-FFR approach could extend the use of QFR and reduces the proportion of invasive FFR-measurements needed while improving accuracy.


Assuntos
Tomada de Decisão Clínica/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Imageamento Tridimensional/métodos , Idoso , Velocidade do Fluxo Sanguíneo , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Confiabilidade dos Dados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Índice de Gravidade de Doença
13.
Front Cardiovasc Med ; 7: 531843, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33330637

RESUMO

Mitral regurgitation is one of the most prevalent valvulopathies worldwide, and its surgical treatment is not feasible in all cases. The elderly and frail with several comorbidities and left ventricular dysfunction are often managed conservatively. Percutaneous treatment (repair or replacement) of the mitral valve has emerged as a potential option for those patients who are at a high risk for surgery. Mitral valve repair with the Mitraclip device proved both increased safety and mortality reduction in patients with severe mitral regurgitation. On the other hand, in the last decade, percutaneous mitral replacement opened new frontiers in the field of cardiac structural interventions. There are few mitral devices; some are in the early phase of development and some are waiting for CE mark of approval. The evolution of these devices was more complicated compared to the aortic technology due to the native mitral valve's complexity and access. This review aims to provide an overview of the current devices, their specific features, and their potential complications.

14.
Circulation ; 142(19): 1799-1807, 2020 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-32862716

RESUMO

BACKGROUND: Approximately 15% of saphenous vein grafts (SVGs) occlude during the first year after coronary artery bypass graft surgery (CABG) despite aspirin use. The POPular CABG trial (The Effect of Ticagrelor on Saphenous Vein Graft Patency in Patients Undergoing Coronary Artery Bypass Grafting Surgery) investigated whether ticagrelor added to standard aspirin improves SVG patency at 1 year after CABG. METHODS: In this investigator-initiated, randomized, double-blind, placebo-controlled, multicenter trial, patients with ≥1 SVGs were randomly assigned (1:1) after CABG to ticagrelor or placebo added to standard aspirin (80 mg or 100 mg). The primary outcome was SVG occlusion at 1 year, assessed with coronary computed tomography angiography, in all patients that had primary outcome imaging available. A generalized estimating equation model was used to perform the primary analysis per SVG. The secondary outcome was 1-year SVG failure, which was a composite of SVG occlusion, SVG revascularization, myocardial infarction in myocardial territory supplied by a SVG, or sudden death. RESULTS: Among 499 randomly assigned patients, the mean age was 67.9±8.3 years, 87.1% were male, the indication for CABG was acute coronary syndrome in 31.3%, and 95.2% of procedures used cardiopulmonary bypass. Primary outcome imaging was available in 220 patients in the ticagrelor group and 223 patients in the placebo group. The SVG occlusion rate in the ticagrelor group was 10.5% (51 of 484 SVGs) versus 9.1% in the placebo group (43 of 470 SVGs), odds ratio, 1.29 [95% CI, 0.73-2.30]; P=0.38. SVG failure occurred in 35 (14.2%) patients in the ticagrelor group versus 29 (11.6%) patients in the placebo group (odds ratio, 1.22 [95% CI, 0.72-2.05]). CONCLUSIONS: In this randomized, placebo-controlled trial, the addition of ticagrelor to standard aspirin did not reduce SVG occlusion at 1 year after CABG. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02352402.


Assuntos
Síndrome Coronariana Aguda , Aspirina/administração & dosagem , Angiografia Coronária , Ponte de Artéria Coronária , Oclusão de Enxerto Vascular , Veia Safena/fisiopatologia , Ticagrelor/administração & dosagem , Grau de Desobstrução Vascular/efeitos dos fármacos , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/fisiopatologia , Síndrome Coronariana Aguda/cirurgia , Idoso , Aspirina/efeitos adversos , Método Duplo-Cego , Feminino , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Oclusão de Enxerto Vascular/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Ticagrelor/efeitos adversos
15.
N Engl J Med ; 383(15): 1447-1457, 2020 10 08.
Artigo em Inglês | MEDLINE | ID: mdl-32865376

RESUMO

BACKGROUND: The effect of single as compared with dual antiplatelet treatment on bleeding and thromboembolic events after transcatheter aortic-valve implantation (TAVI) in patients who do not have an indication for long-term anticoagulation has not been well studied. METHODS: In a randomized, controlled trial, we assigned a subgroup of patients who were undergoing TAVI and did not have an indication for long-term anticoagulation, in a 1:1 ratio, to receive aspirin alone or aspirin plus clopidogrel for 3 months. The two primary outcomes were all bleeding (including minor, major, and life-threatening or disabling bleeding) and non-procedure-related bleeding over a period of 12 months. Most bleeding at the TAVI puncture site was counted as non-procedure-related. The two secondary outcomes were a composite of death from cardiovascular causes, non-procedure-related bleeding, stroke, or myocardial infarction (secondary composite 1) and a composite of death from cardiovascular causes, ischemic stroke, or myocardial infarction (secondary composite 2) at 1 year, with both outcomes tested sequentially for noninferiority (noninferiority margin, 7.5 percentage points) and superiority. RESULTS: A total of 331 patients were assigned to receive aspirin alone and 334 were assigned to receive aspirin plus clopidogrel. A bleeding event occurred in 50 patients (15.1%) receiving aspirin alone and in 89 (26.6%) receiving aspirin plus clopidogrel (risk ratio, 0.57; 95% confidence interval [CI], 0.42 to 0.77; P = 0.001). Non-procedure-related bleeding occurred in 50 patients (15.1%) and 83 patients (24.9%), respectively (risk ratio, 0.61; 95% CI, 0.44 to 0.83; P = 0.005). A secondary composite 1 event occurred in 76 patients (23.0%) receiving aspirin alone and in 104 (31.1%) receiving aspirin plus clopidogrel (difference, -8.2 percentage points; 95% CI for noninferiority, -14.9 to -1.5; P<0.001; risk ratio, 0.74; 95% CI for superiority, 0.57 to 0.95; P = 0.04). A secondary composite 2 event occurred in 32 patients (9.7%) and 33 patients (9.9%), respectively (difference, -0.2 percentage points; 95% CI for noninferiority, -4.7 to 4.3; P = 0.004; risk ratio, 0.98; 95% CI for superiority, 0.62 to 1.55; P = 0.93). A total of 44 patients (13.3%) and 32 (9.6%), respectively, received oral anticoagulation during the trial. CONCLUSIONS: Among patients undergoing TAVI who did not have an indication for oral anticoagulation, the incidence of bleeding and the composite of bleeding or thromboembolic events at 1 year were significantly less frequent with aspirin than with aspirin plus clopidogrel administered for 3 months. (Funded by the Netherlands Organization for Health Research and Development; POPular TAVI EU Clinical Trials Register number, 2013-003125-28; ClinicalTrials.gov number, NCT02247128.).


Assuntos
Aspirina/uso terapêutico , Clopidogrel/uso terapêutico , Hemorragia/induzido quimicamente , Inibidores da Agregação Plaquetária/uso terapêutico , Trombose/prevenção & controle , Substituição da Valva Aórtica Transcateter , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Aspirina/efeitos adversos , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/mortalidade , Clopidogrel/efeitos adversos , Quimioterapia Combinada , Feminino , Hemorragia/epidemiologia , Humanos , Incidência , Masculino , Inibidores da Agregação Plaquetária/efeitos adversos , Período Pós-Operatório , Trombose/epidemiologia
16.
Curr Cardiol Rep ; 22(9): 80, 2020 07 09.
Artigo em Inglês | MEDLINE | ID: mdl-32648007

RESUMO

PURPOSE OF REVIEW: The TAVR procedure is a well-established therapy for patients with severe aortic stenosis at intermediate/high risk for surgery and a potential treatment for low-risk patients. It is much less invasive with short hospital stays and presents similar results compared with SAVR. Different "minimalist approach strategies" were proposed in order to obtain this performance. In these settings, transesophageal echocardiography (TEE) became less relevant for the TAVR procedure. The present review provides an update regarding the safety of TAVR without intraprocedural TEE. RECENT FINDINGS: Transthoracic echocardiography and fluoroscopy are the primary imaging tools during TAVR. Several studies proved that TAVR under local anesthesia without TEE is as safe as that performed under TEE guidance. However, not all patients have a proper window for TTE, and particular cases with complex anatomy can benefit from TEE support during the intervention. Intraprocedural TEE no longer plays a crucial role in the TAVR procedure, but in some instances, it remains of great help to detect and avoid complications.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Ecocardiografia Transesofagiana , Humanos , Resultado do Tratamento
17.
Expert Rev Med Devices ; 17(7): 615-626, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32543911

RESUMO

INTRODUCTION: Atrial fibrillation (AF) is associated with an increased risk of stroke. Stroke prevention with oral anticoagulation (OAC) is recommended in AF patients at increased risk of stroke. The left atrial appendage (LAA) is the main source of thrombus formation in AF patients. The WATCHMAN percutaneous LAA closure (LAAC) device may serve as an alternative to OAC overcoming disadvantages including the risk of (major) bleeding. AREAS COVERED: This review will focus on LAAC with the Watchman device for stroke prevention in AF patients. Current status, available literature, clinical safety and efficacy will be summarized. Furthermore, the future perspectives of Watchman will be discussed. EXPERT OPINION: LAAC with Watchman appears a promising, safe, and effective alternative to OAC. Ongoing and future studies to consolidate the position of Watchman should focus on comparative safety and efficacy of different LAAC devices, patient selection, various post-procedural antithrombotic regimens, head-to-head comparisons with NOAC, better understanding of device-related thrombus, and the role of the LAA in the propagation of non-valvular AF. This research may attribute to a paradigm shift in which LAAC no longer serves as a 'last resort' treatment for AF patients ineligible for OAC but may serve as a second-line or even first-line treatment option for AF patients.


Assuntos
Apêndice Atrial/patologia , Fibrilação Atrial/terapia , Equipamentos e Provisões , Anticoagulantes/efeitos adversos , Fibrilação Atrial/complicações , Análise Custo-Benefício , Equipamentos e Provisões/efeitos adversos , Equipamentos e Provisões/economia , Humanos , Resultado do Tratamento
18.
Thromb Haemost ; 120(7): 1087-1095, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32572864

RESUMO

BACKGROUND: The utility of the PRECISE-DAPT score in predicting short-term major bleeding, either alone, or in comparison with the CRUSADE and ACUITY scores, has not been investigated. This analysis compared the predictive performances of the three bleeding scores in stratifying the risk of 30-day major bleeding postpercutaneous coronary intervention in patients with dual-antiplatelet therapy. METHODS: In this post hoc subanalysis of the GLOBAL LEADERS trial, the primary safety objective (bleeding according to the Bleeding Academic Research Consortium [BARC] criteria [type 3 or 5]) was assessed at 30 days according to the three scores in the overall population, and in patients with acute (ACS) and chronic coronary syndrome (CCS). RESULTS: In a total of 15,968 patients, we calculated all three scores in 14,709 (92.1%). Irrespective of clinical presentation, the PRECISE-DAPT (c-statistics: 0.648, 0.653, and 0.641, respectively), CRUSADE (c-statistics: 0.641, 0.639, and 0.644, respectively), and ACUITY (c-statistics: 0.633, 0.638, and 0.623, respectively) scores were no significant between-score differences in discriminatory performance for BARC 3 or 5 bleeding up to 30 days, and similarly the PRECISE-DAPT score had a comparable discriminative capacity according to the integrated discrimination improvement when compared with the other scores. In ACS, the CRUSADE score had a poor calibration ability (Hosmer-Lemeshow goodness-of-fit [GOF] chi-square = 15.561, p = 0.049), whereas in CCS, the PRECISE-DAPT score had poor calibration (GOF chi-square = 15.758, p = 0.046). CONCLUSION: The PRECISE-DAPT score might be clinically useful in the overall population and ACS patients for the prediction of short-term major bleeding considering its discriminative and calibration abilities.


Assuntos
Síndrome Coronariana Aguda/terapia , Doença da Artéria Coronariana/terapia , Técnicas de Apoio para a Decisão , Terapia Antiplaquetária Dupla/efeitos adversos , Hemorragia/induzido quimicamente , Intervenção Coronária Percutânea/efeitos adversos , Idoso , Doença Crônica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
19.
BMC Health Serv Res ; 20(1): 232, 2020 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-32192477

RESUMO

BACKGROUND: Measuring and improving outcomes is a central element of value-based health care. However, selecting improvement interventions based on outcome measures is complex and tools to support the selection process are lacking. The goal was to present strategies for the systematic identification and selection of improvement interventions applied to the case of aortic valve disease and to combine various methods of process and outcome assessment into one integrated approach for quality improvement. METHODS: For this case study a concept-driven mixed-method approach was applied for the identification of improvement intervention clusters including: (1) benchmarking outcomes, (2) data exploration, (3) care delivery process analysis, and (4) monitoring of ongoing improvements. The main outcome measures were long-term survival and 30-day mortality. For the selection of an improvement intervention, the causal relations between the potential improvement interventions and outcome measures were quantified followed by a team selection based on consensus from a multidisciplinary team of professionals. RESULTS: The study resulted in a toolbox: the Intervention Selection Toolbox (IST). The toolbox comprises two phases: (a) identifying potential for improvement, and (b) selecting an effective intervention from the four clusters expected to lead to the desired improvement in outcomes. The improvements identified for the case of aortic valve disease with impact on long-term survival in the context of the studied hospital in 2015 include: anticoagulation policy, increased attention to nutritional status of patients and determining frailty of patients before the treatment decision. CONCLUSIONS: Identifying potential for improvement and carefully selecting improvement interventions based on (clinical) outcome data demands a multifaceted approach. Our toolbox integrates both care delivery process analyses and outcome analyses. The toolbox is recommended for use in hospital care for the selection of high-impact improvement interventions.


Assuntos
Atenção à Saúde/normas , Cardiopatias Congênitas , Doenças das Valvas Cardíacas , Melhoria de Qualidade , Resultado do Tratamento , Valva Aórtica/fisiopatologia , Benchmarking , Doença da Válvula Aórtica Bicúspide , Serviços de Saúde , Cardiopatias Congênitas/mortalidade , Doenças das Valvas Cardíacas/mortalidade , Hospitais , Humanos , Avaliação de Resultados em Cuidados de Saúde
20.
N Engl J Med ; 382(18): 1696-1707, 2020 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-32223116

RESUMO

BACKGROUND: The roles of anticoagulation alone or with an antiplatelet agent after transcatheter aortic-valve implantation (TAVI) have not been well studied. METHODS: We performed a randomized trial of clopidogrel in patients undergoing TAVI who were receiving oral anticoagulation for appropriate indications. Patients were assigned before TAVI in a 1:1 ratio not to receive clopidogrel or to receive clopidogrel for 3 months. The two primary outcomes were all bleeding and non-procedure-related bleeding over a period of 12 months. Procedure-related bleeding was defined as Bleeding Academic Research Consortium type 4 severe bleeding, and therefore most bleeding at the puncture site was counted as non-procedure-related. The two secondary outcomes were a composite of death from cardiovascular causes, non-procedure-related bleeding, stroke, or myocardial infarction at 12 months (secondary composite 1) and a composite of death from cardiovascular causes, ischemic stroke, or myocardial infarction (secondary composite 2), both tested for noninferiority (noninferiority margin, 7.5 percentage points) and superiority. RESULTS: Bleeding occurred in 34 of the 157 patients (21.7%) receiving oral anticoagulation alone and in 54 of the 156 (34.6%) receiving oral anticoagulation plus clopidogrel (risk ratio, 0.63; 95% confidence interval [CI], 0.43 to 0.90; P = 0.01); most bleeding events were at the TAVI access site. Non-procedure-related bleeding occurred in 34 patients (21.7%) and in 53 (34.0%), respectively (risk ratio, 0.64; 95% CI, 0.44 to 0.92; P = 0.02). Most bleeding occurred in the first month and was minor. A secondary composite 1 event occurred in 49 patients (31.2%) receiving oral anticoagulation alone and in 71 (45.5%) receiving oral anticoagulation plus clopidogrel (difference, -14.3 percentage points; 95% CI for noninferiority, -25.0 to -3.6; risk ratio, 0.69; 95% CI for superiority, 0.51 to 0.92). A secondary composite 2 event occurred in 21 patients (13.4%) and in 27 (17.3%), respectively (difference, -3.9 percentage points; 95% CI for noninferiority, -11.9 to 4.0; risk ratio, 0.77; 95% CI for superiority, 0.46 to 1.31). CONCLUSIONS: In patients undergoing TAVI who were receiving oral anticoagulation, the incidence of serious bleeding over a period of 1 month or 1 year was lower with oral anticoagulation alone than with oral anticoagulation plus clopidogrel. (Funded by the Netherlands Organization for Health Research and Development; POPular TAVI EU Clinical Trials Register number, 2013-003125-28; ClinicalTrials.gov number, NCT02247128.).


Assuntos
Anticoagulantes/uso terapêutico , Clopidogrel/uso terapêutico , Hemorragia/induzido quimicamente , Inibidores da Agregação Plaquetária/uso terapêutico , Substituição da Valva Aórtica Transcateter , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/mortalidade , Clopidogrel/efeitos adversos , Quimioterapia Combinada , Hemorragia/epidemiologia , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Inibidores da Agregação Plaquetária/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA