Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Med ; 13(15)2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39124580

RESUMO

Background/Objectives: The literature reports high complication rates in patients with chronic thromboembolic pulmonary hypertension (CTEPH) who undergo balloon pulmonary angioplasty (BPA), especially in patients with poor pulmonary hemodynamics. Here, we describe the complications of BPA based on the new definitions. Methods: All patients with CTEPH who completed BPA treatment before 15 September 2023 were selected from the CTEPH database. Peri-procedural complications were collected and classified according to the 2023 consensus paper on BPA treatment. Complications were analyzed in subgroups of patients with pulmonary vascular resistance (PVR), ≤ or >6.6 WU, and mean pulmonary artery pressure (mPAP), ≤ or >45 mmHg, at first BPA. Results: In this analysis, 87 patients (63% women; mean age 61.1 ± 14.0 years; 62% on dual PH targeted medical therapy) underwent 426 (mean 4.9 ± 1.6 per patient) BPAs. Only non-severe complications occurred in 14% of BPA treatments and in 47% of the patients; 31% patients had a thoracic complication. The thoracic complications were mild (71%) or moderate (29%). Patients with a PVR > 6.6 WU (n = 8) underwent more BPA treatments (6.6 ± 1.5 versus 4.6 ± 1.5, p = 0.002), had more complications (88% versus 41% of patients, p = 0.020), and had more thoracic complications (17% vs. 7% of BPAs, p = 0.013) than patients with PVR ≤ 6.6 WU. Patients with mPAP > 45 mmHg (n = 13) also had more BPA treatments (6.5 ± 1.7 versus 4.6 ± 1.4, p < 0.001), more complications (77% versus 44% of patients, p = 0.027) and more thoracic complications (14% versus 8% of BPAs, p = 0.039) than patients with mPAP ≤ 45 mmHg. Conclusions: Complications occurred in 14% of BPAs and were mostly mild. Patients with severe pulmonary hemodynamics suffered more (thoracic) complications.

2.
JACC Cardiovasc Interv ; 15(11): 1140-1149, 2022 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-35680194

RESUMO

BACKGROUND: The work-up for transcatheter aortic valve replacement (TAVR) currently uses computed tomography to evaluate the annulus diameter and peripheral vascular access plus invasive coronary angiography (ICA) to assess significant coronary artery disease (CAD). ICA might partially be redundant with the use of coronary computed tomography angiography (CCTA). Prior studies found an improvement of the diagnostic accuracy of CCTA with the use of computed tomography-derived fractional flow reserve (CT-FFR). OBJECTIVES: The aim of this study was to assess the diagnostic performance of CT-FFR for the diagnosis of CAD in the work-up for TAVR. METHODS: Consecutive patients with severe symptomatic aortic valve stenosis who underwent TAVR work-up between 2015 and 2019 were included in this retrospective cross-sectional study. All patients underwent CCTA and ICA within 3 months, and the diagnostic performance of both CCTA and CT-FFR was assessed using ICA as the reference. RESULTS: Seventy-six of the 338 patients included in the analysis had ≥1 significant coronary stenosis on ICA. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy per patient were 76.9%, 64.5%, 34.0%, 92.1%, and 66.9% for CCTA and 84.6%, 88.3%, 63.2%, 96.0%, and 87.6% for CT-FFR. The area under the receiver-operating characteristic curve was significantly different between CCTA and CT-FFR (0.84 vs 0.90, P = 0.02). A CT-FFR-guided approach could avoid ICA in 57.1% versus 43.6% of patients using CCTA. CONCLUSIONS: CT-FFR significantly improves the diagnostic accuracy of CCTA without additional testing and increases the proportion of patients in whom ICA could have been safely avoided. It has the potential to be integrated in the current clinical work-up for TAVR for diagnosing stable CAD requiring treatment.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Substituição da Valva Aórtica Transcateter , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Estudos Transversais , Humanos , Valor Preditivo dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA