1.
Eur J Cardiothorac Surg ; 39(5): e139-43, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21334912

RESUMO

OBJECTIVE: To measure surrogate markers of coagulation activation as well as of the systemic inflammatory response in patients undergoing primary elective coronary artery bypass grafting (CABG) using either the so-called Smart suction device or a continuous autotransfusion system (C.A.T.S.®). METHODS: Fifty-eight patients being operated with a miniaturized circuit (minimal extracorporeal circuit, MECC) were prospectively randomized to using a so-called Smart suction device or a routine continuous autotransfusion system (C.A.T.S.®) for collection of mediastinal shed blood. The coagulation response was measured by thrombin-antithrombin complex (TAT) and D-dimer. The inflammatory response was measured by Interleukin 6 (IL-6) and complement factor 3a (C3a) at three different time points, before surgery, 2h after surgery, as well as 18 h after surgery. RESULTS: No serious adverse cardiovascular event was observed. Serum levels of TAT significantly differed between both groups 2h after surgery (Smart suction 16.12 ± 13.51 µg l⁻¹ vs C.A.T.S® 9.83 ± 7.81 µg l⁻¹, p = 0.040) and returned to baseline values after 18 h in both groups. Serum levels of D-dimer showed a corresponding pattern with a peak 2h after surgery (Smart suction 1115 ± 1231 ng ml⁻¹ vs C.A.T.S.® 507 ± 604 ng ml⁻¹, p = 0.025). IL-6 levels also significantly differed between both groups 2h after surgery (Smart suction 186 ± 306 pg ml⁻¹ vs C.A.T.S.® 82 ± 71 pg ml⁻¹, p = 0.072). No significant changes in serum levels of C3a over time could be observed. CONCLUSIONS: Despite no differences in the clinical course of patients with either Smart suction or C.A.T.S.® being observed, surrogate markers of coagulation and inflammation seem to be less pronounced in patients where cardiotomy blood is not being directly reinfused. As such, C.A.T.S.® should be preferred in routine CABG, as long as no extensive volume substitution is anticipated.


Assuntos
Coagulação Sanguínea/fisiologia , Ponte de Artéria Coronária/instrumentação , Síndrome de Resposta Inflamatória Sistêmica/etiologia , Idoso , Antitrombina III , Biomarcadores/sangue , Transfusão de Sangue Autóloga , Complemento C3a/metabolismo , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/métodos , Produtos de Degradação da Fibrina e do Fibrinogênio/metabolismo , Humanos , Mediadores da Inflamação/metabolismo , Interleucina-6/sangue , Pessoa de Meia-Idade , Peptídeo Hidrolases/sangue , Estudos Prospectivos , Sucção , Síndrome de Resposta Inflamatória Sistêmica/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA