Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 100
Filtrar
1.
Eur Heart J Open ; 4(5): oeae075, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39346895

RESUMO

Aims: Cardiogenic shock (CS) and cardiac arrest (CA) are serious complications in ST-elevation myocardial infarction (STEMI) patients, with lack of long-term data according to their timing of occurrence. This study sought to determine the incidence and relationship between the timing of occurrence and prognostic impact of CS and CA complicating STEMI in the long-term follow-up. Methods and results: We conducted a retrospective analysis of consecutive STEMI patients treated between 2004 and 2017. Patients were divided into four groups based on the occurrence of neither CA nor CS, CA only, CS only, and both CA and CS (CA-CS-, CA+, CS+, and CA+CS+, respectively). Adjusted Cox regression analysis was used to assess the independent association between the CS and CA categories and mortality. A total of 1603 STEMI patients were followed for a median of 3.6 years. CA and CS occurred in the 12.2% and 15.9% of patients, and both impacted long-term mortality [adjusted hazard ratio (HR) = 2.59, 95% confidence interval (CI): 1.53-4.41, P < 0.001; HR = 3.16, 95% CI: 2.21-4.53, P < 0.001, respectively). CA+CS+ occurred in 7.3%, with the strongest association with higher mortality (adjusted HR = 5.36; 95% CI: 3.80-7.55, P < 0.001). Using flexible parametric models with B-splines, the increased mortality was restricted to the first ∼10 months. In addition, overall mortality rates were higher at all timings (all with P < 0.001), except for CA during initial cardiac catheterization (P < 0.183). Conclusion: CS and CA complicating patients presenting with STEMI were associated with higher long-term mortality rate, especially in the first 10 months. Both CS+ and CA+ at any timeframe impacted outcomes, except for CA+ during the initial cardiac catheterization, although this will have to be confirmed in larger future studies, given the relatively small number of patients.

2.
Arq Bras Cardiol ; 121(7): e202400415, 2024 Jul 26.
Artigo em Português, Inglês | MEDLINE | ID: mdl-39082572
3.
Arq Bras Cardiol ; 121(7): e20230622, 2024 Jun.
Artigo em Português, Inglês | MEDLINE | ID: mdl-39082574

RESUMO

BACKGROUND: Robust data on the learning curve (LC) of transcatheter aortic valve replacement (TAVR) are lacking in developing countries. OBJECTIVE: To assess TAVR's LC in Brazil over time. METHODS: We analyzed data from the Brazilian TAVR registry from 2008 to 2023. Patients from each center were numbered chronologically in case sequence numbers (CSNs). LC was performed using restricted cubic splines adjusted for EuroSCORE-II and the use of new-generation prostheses. Also, in-hospital outcomes were compared between groups defined according to the level of experience based on the CSN: 1st to 40th (initial-experience), 41st to 80th (early-experience), 81st to 120th (intermediate-experience), and over 121st (high-experience). Additional analysis was performed grouping hospitals according to the number of cases treated before 2014 (>40 and ≤40 procedures). The level of significance adopted was <0.05. RESULTS: A total of 3,194 patients from 25 centers were included. Mean age and EuroSCORE II were 80.7±8.1 years and 7±7.1, respectively. LC analysis demonstrated a drop in adjusted in-hospital mortality after treating 40 patients. A leveling off of the curve was observed after case #118. In-hospital mortality across the groups was 8.6%, 7.7%, 5.9%, and 3.7% for initial-, early-, intermediate-, and high-experience, respectively (p<0.001). High experience independently predicted lower mortality (OR 0.57, p=0.013 vs. initial experience). Low-volume centers before 2014 showed no significant decrease in the likelihood of death with gained experience, whereas high-volume centers had a continuous improvement after case #10. CONCLUSION: A TAVR LC phenomenon was observed for in-hospital mortality in Brazil. This effect was more pronounced in centers that treated their first 40 cases before 2014 than those that reached this milestone after 2014.


Assuntos
Mortalidade Hospitalar , Curva de Aprendizado , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Brasil/epidemiologia , Feminino , Masculino , Idoso de 80 Anos ou mais , Idoso , Fatores de Tempo , Fatores de Risco , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Resultado do Tratamento , Medição de Risco
4.
Arq. bras. cardiol ; 121(7): e20230622, jun.2024. tab, graf
Artigo em Português | LILACS-Express | LILACS, SESSP-IDPCPROD, SES-SP | ID: biblio-1563934

RESUMO

Resumo Fundamento Dados robustos sobre a curva de aprendizagem (LC) da substituição da válvula aórtica transcateter (TAVR) são escassos nos países em desenvolvimento. Objetivo Avaliar a LC da TAVR no Brasil ao longo do tempo. Métodos Analisamos dados do registro brasileiro de TAVR de 2008 a 2023. Pacientes de cada centro foram numerados cronologicamente em número sequencial de caso (NSC). A LC foi realizada usando um spline cúbico restrito ajustado para o EuroSCORE-II e o uso de próteses de nova geração. Ainda, os desfechos hospitalares foram comparados entre grupos definidos de acordo com o nível de experiência, com base no NSC: 1º ao 40º caso (experiência inicial), 41º ao 80º caso (experiência básica), 81º ao 120º caso (experiência intermediária) e 121º caso em diante (experiência alta). Análises adicionais foram conduzidas de acordo com o número de casos tratados antes de 2014 (>40 e ≤40 procedimentos). O nível de significância adotado foi p <0,05. Resultados Foram incluídos 3194 pacientes de 25 centros. A idade média foi 80,7±8,1 anos e o EuroSCORE II médio foi 7±7,1. A análise da LC demonstrou uma queda na mortalidade hospitalar ajustada após o tratamento de 40 pacientes. Um patamar de nivelamento na curva foi observado após o caso 118. A mortalidade hospitalar entre os grupos foi 8,6%, 7,7%, 5,9%, e 3,7% para experiência inicial, básica, intermediária e alta, respectivamente (p<0,001). A experiência alta foi preditora independente de mortalidade mais baixa (OR 0,57, p=0,013 vs. experiência inicial). Centros com baixo volume de casos antes de 2014 não mostraram uma redução significativa na probabilidade de morte com o ganho de experiência, enquanto centros com alto volume de casos antes de 2014 apresentaram uma melhora contínua após o caso de número 10. Conclusão Observou-se um fenômeno de LC para a mortalidade hospitalar do TAVR no Brasil. Esse efeito foi mais pronunciado em centros que trataram seus 40 primeiros casos antes de 2014 que naqueles que o fizeram após 2014.


Abstract Background Robust data on the learning curve (LC) of transcatheter aortic valve replacement (TAVR) are lacking in developing countries. Objective To assess TAVR's LC in Brazil over time. Methods We analyzed data from the Brazilian TAVR registry from 2008 to 2023. Patients from each center were numbered chronologically in case sequence numbers (CSNs). LC was performed using restricted cubic splines adjusted for EuroSCORE-II and the use of new-generation prostheses. Also, in-hospital outcomes were compared between groups defined according to the level of experience based on the CSN: 1st to 40th (initial-experience), 41st to 80th (early-experience), 81st to 120th (intermediate-experience), and over 121st (high-experience). Additional analysis was performed grouping hospitals according to the number of cases treated before 2014 (>40 and ≤40 procedures). The level of significance adopted was <0.05. Results A total of 3,194 patients from 25 centers were included. Mean age and EuroSCORE II were 80.7±8.1 years and 7±7.1, respectively. LC analysis demonstrated a drop in adjusted in-hospital mortality after treating 40 patients. A leveling off of the curve was observed after case #118. In-hospital mortality across the groups was 8.6%, 7.7%, 5.9%, and 3.7% for initial-, early-, intermediate-, and high-experience, respectively (p<0.001). High experience independently predicted lower mortality (OR 0.57, p=0.013 vs. initial experience). Low-volume centers before 2014 showed no significant decrease in the likelihood of death with gained experience, whereas high-volume centers had a continuous improvement after case #10. Conclusion A TAVR LC phenomenon was observed for in-hospital mortality in Brazil. This effect was more pronounced in centers that treated their first 40 cases before 2014 than those that reached this milestone after 2014.

5.
J Clin Med ; 13(12)2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38930026

RESUMO

Background/Objectives: To date, data regarding the characteristics and management of obstructive, stable coronary artery disease (CAD) encountered in patients undergoing transcatheter aortic valve implantation (TAVI) are sparse. The aim of the study was to analyze granular details, treatment, and outcomes of patients undergoing TAVI with obstructive, stable CAD from real-world practice. Methods: REVASC-TAVI (Management of myocardial REVASCularization in patients undergoing Transcatheter Aortic Valve Implantation with coronary artery disease) is an investigator-initiated, multicenter registry, which collected data from patients undergoing TAVI with obstructive stable CAD found during the pre-TAVI work-up. Results: A total of 2025 patients from 30 centers worldwide with complete follow-up were included in the registry. Most patients had single-vessel CAD (56.1%). An involvement of proximal coronary tracts was detected in 62.5% of cases, with 12.0% of patients having CAD in left main (LM). Most patients received percutaneous coronary intervention (PCI) (n = 1617, 79.9%), especially those with proximal CAD (90.4%). At 2 years, the rates of all-cause death [Kaplan-Meier (KM) estimates 20.1% vs. 18.8%, plog-rank = 0.86] and of the composite of all-cause death, stroke, myocardial infarction, and rehospitalization for heart failure (KM estimates 29.7% vs. 27.5%, plog-rank = 0.82) did not differ between patients undergoing PCI and those who were not. Conclusions: Patients undergoing TAVI with obstructive CAD more commonly had a single-vessel disease and an involvement of proximal coronary tracts. They were commonly treated with PCI, with similar outcomes compared to those treated conservatively.

6.
Int J Cardiol ; 400: 131768, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38211668

RESUMO

BACKGROUND: Transcatheter edge-to-edge repair (TEER) has become an established treatment for primary and secondary mitral regurgitation (PMR and SMR). The objective of this study was to compare the accuracy of different risk scores for predicting 1-year mortality and the composite endpoint of 1-year mortality and/or heart failure (HF) hospitalization after TEER. METHODS: We analyzed data from 206 patients treated for MR at a tertiary European center between 2011 and 2023 and compared the accuracy of different mitral and surgical risk scores: EuroSCORE II, GRASP, MITRALITY, MitraScore, TAPSE/PASP-MitraScore, and STS for predicting 1-year mortality and the composite of 1-year mortality and/or HF hospitalization in PMR and SMR. A subanalysis of SMR-only patients with the addition of COAPT Risk Score and baseline N-Terminal pro-Brain Natriuretic Peptide (NT-proBNP) list was also performed. RESULTS: MITRALITY had the best discriminative ability for 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization, with an area under the curve (AUC) of 0.74 and 0.74, respectively, in a composed group of PMR and SMR. In a SMR-only population, MITRALITY also presented the best AUC for 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization, with values of 0.72 and 0.72, respectively. CONCLUSION: MITRALITY was the best mitral TEER risk model for both 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization in a population of PMR and SMR patients, as well as in SMR patients only. Surgical risk scores, MitraScore, TAPSE/PASP-MitraScore and NT-proBNP alone showed poor predictive values.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Hospitalização , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Fatores de Risco , Resultado do Tratamento
7.
Circulation ; 149(9): 644-655, 2024 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-37883682

RESUMO

BACKGROUND: The optimal treatment in patients with severe aortic stenosis and small aortic annulus (SAA) remains to be determined. This study aimed to compare the hemodynamic and clinical outcomes between transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) in patients with a SAA. METHODS: This prospective multicenter international randomized trial was performed in 15 university hospitals. Participants were 151 patients with severe aortic stenosis and SAA (mean diameter <23 mm) randomized (1:1) to TAVR (n=77) versus SAVR (n=74). The primary outcome was impaired valve hemodynamics (ie, severe prosthesis patient mismatch or moderate-severe aortic regurgitation) at 60 days as evaluated by Doppler echocardiography and analyzed in a central echocardiography core laboratory. Clinical events were secondary outcomes. RESULTS: The mean age of the participants was 75.5±5.1 years, with 140 (93%) women, a median Society of Thoracic Surgeons predicted risk of mortality of 2.50% (interquartile range, 1.67%-3.28%), and a median annulus diameter of 21.1 mm (interquartile range, 20.4-22.0 mm). There were no differences between groups in the rate of severe prosthesis patient mismatch (TAVR, 4 [5.6%]; SAVR, 7 [10.3%]; P=0.30) and moderate-severe aortic regurgitation (none in both groups). No differences were found between groups in mortality rate (TAVR, 1 [1.3%]; SAVR, 1 [1.4%]; P=1.00) and stroke (TAVR, 0; SAVR, 2 [2.7%]; P=0.24) at 30 days. After a median follow-up of 2 (interquartile range, 1-4) years, there were no differences between groups in mortality rate (TAVR, 7 [9.1%]; SAVR, 6 [8.1%]; P=0.89), stroke (TAVR, 3 [3.9%]; SAVR, 3 [4.1%]; P=0.95), and cardiac hospitalization (TAVR, 15 [19.5%]; SAVR, 15 [20.3%]; P=0.80). CONCLUSIONS: In patients with severe aortic stenosis and SAA (women in the majority), there was no evidence of superiority of contemporary TAVR versus SAVR in valve hemodynamic results. After a median follow-up of 2 years, there were no differences in clinical outcomes between groups. These findings suggest that the 2 therapies represent a valid alternative for treating patients with severe aortic stenosis and SAA, and treatment selection should likely be individualized according to baseline characteristics, additional anatomical risk factors, and patient preference. However, the results of this study should be interpreted with caution because of the limited sample size leading to an underpowered study, and need to be confirmed in future larger studies. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03383445.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Estudos Prospectivos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco , Acidente Vascular Cerebral/etiologia
8.
Am J Cardiol ; 214: 8-17, 2024 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-38104756

RESUMO

This study aimed to evaluate the incidence and clinical implications of myocardial injury, as determined by cardiac biomarker increase, in patients who underwent mitral bioprosthesis dysfunction treatment with transcatheter mitral valve replacement (TMVR) versus surgical mitral valve replacement reoperation (SMVR-REDO). Between 2014 and 2023, 310 patients with mitral bioprosthesis failure were included (90 and 220 patients for TMVR and SMVR-REDO, respectively). Multivariable analysis and propensity score matching were performed to adjust for the intergroup differences in baseline characteristics. Creatinine kinase-MB (CK-MB) and cardiac troponin I (cTn) were collected at baseline and 6 to 12, 24, 48, and 72 hours after intervention. The cardiac biomarkers values were evaluated in relation to their reference values. The outcomes were determined according to the Mitral Valve Academic Research Consortium criteria. CK-MB and cTn increased above the reference level in almost all patients after SMVR-REDO and TMVR (100% vs 94%, respectively), with the peak occurring within 6 to 12 hours. SMVR-REDO was associated with a two- to threefold higher increase in cardiac biomarkers. After 30 days, the mortality rates were 13.3% in the TMVR and 16.8% in the SMVR-REDO groups. At a median follow-up of 19 months, the mortality rates were 21.1% in the TMVR and 17.7% in the SMVR-REDO groups. Left ventricular ejection fraction, estimated glomerular filtration rate, CK-MB, and cTn were predictors of mortality. In conclusion, some degree of myocardial injury occurred systematically after the treatment of mitral bioprosthetic degeneration, especially after SMVR, and higher CK-MB and cTn levels were associated with increased cumulative late mortality, regardless of the approach.


Assuntos
Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Valva Mitral/cirurgia , Reoperação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Volume Sistólico , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Resultado do Tratamento , Função Ventricular Esquerda , Doenças das Valvas Cardíacas/cirurgia , Biomarcadores , Cateterismo Cardíaco/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos
9.
Arq Bras Cardiol ; 120(11): e20220496, 2023 Nov.
Artigo em Português, Inglês | MEDLINE | ID: mdl-38126512

RESUMO

BACKGROUND: Central Illustration : Percutaneous Strategies in Structural Heart Diseases: Focus on Chronic Heart Failure Transcatheter devices for monitoring and treating advanced chronic heart failure patients. PA: pulmonary artery; LA: left atrium; AFR: atrial flow regulator; TASS: Transcatheter Atrial Shunt System; VNS: vagus nerve stimulation; BAT: baroreceptor activation therapy; RDN: renal sympathetic denervation; F: approval by the American regulatory agency (FDA); E: approval by the European regulatory agency (CE Mark). BACKGROUND: Innovations in devices during the last decade contributed to enhanced diagnosis and treatment of patients with cardiac insufficiency. These tools progressively adapted to minimally invasive strategies with rapid, widespread use. The present article focuses on actual and future directions of device-related diagnosis and treatment of chronic heart failure.


Assuntos
Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/terapia , Simpatectomia , Átrios do Coração , Rim
10.
J. bras. econ. saúde (Impr.) ; 15(3): 190-199, Dezembro/2023.
Artigo em Inglês, Português | LILACS, ECOS | ID: biblio-1553993

RESUMO

Objective: To generate data on the costs associated with the diagnosis and treatment of obstructive ypertrophic cardiomyopathy (HCM) from the perspective of the private health system in Brazil. Methods: A modified Delphi panel including seven different specialists (three clinical cardiologists with experience in obstructive HCM, two hemodynamicists with experience in septal ablation and two cardiac surgeons with expertise in myectomy), from two Brazilian states (São Paulo and Pernambuco), was conducted between August and November 2022. Two rounds of questions about the use of healthcare resources according to the functional class (NYHA I-IV) and a panel in a virtual platform were conducted to obtain the final consensus. Micro-costing defined costs and unit values were determined based on official price lists. Results: The total diagnosis cost per patient was estimated at BRL 11,486.81. The obstructive HCM management costs analysis showed average annual costs per patient of BRL 17,026.74, BRL 19,401.46, BRL 73,310.07, and BRL 94,885.75 for the functional classes NYHA I, NYHA II, NYHA III, and NYHA IV, respectively. The average costs per patient related to procedures in a year were BRL 12,698.53, BRL 13,462.30, BRL 58,841.67, and BRL 75,595.90 for the functional classes NYHA I, II, III, and IV, respectively. Conclusions: The annual costs of HCM management increased according to the functional class, highlighting the need for safe and effective strategies to improve patient's NYHA functional class while promoting a decrease in the need for invasive therapies.


Objetivo: Gerar dados acerca dos custos associados ao diagnóstico e tratamento da cardiomiopatia hipertrófica (CMH) obstrutiva, sob a perspectiva do sistema de saúde privado no Brasil. Métodos: Um painel Delphi modificado incluindo sete especialistas (três cardiologistas clínicos com experiência em CMH obstrutiva, dois hemodinamicistas com experiência em ablação de septo e dois cirurgiões cardíacos com experiência em miectomia) de dois estados brasileiros (São Paulo e Pernambuco) foi conduzido entre agosto e novembro de 2022. Foram realizadas duas rodadas de perguntas acerca da utilização de recursos de acordo com a classe funcional (NYHA I-IV) e uma reunião virtual para obtenção do consenso final. Os custos foram definidos por meio de microcusteio, e os valores unitários foram definidos com base em listas de preço oficiais. Resultados: O custo total do diagnóstico por paciente foi estimado em R$ 11.486,81. A análise de custos de manejo da CMH obstrutiva mostrou custos médios anuais por paciente de R$ 17.026,74, R$ 19.401,46, R$ 73.310,07 e R$ 94.885,75 para as classes funcionais NYHA I, NYHA II, NYHA III e NYHA IV, respectivamente. Os custos médios por paciente relacionados a procedimentos em um ano foram de R$ 12.698,53, R$ 13.462,30, R$ 58.841,67 e R$ 75.595,90 para as classes NYHA I, II, III e IV, respectivamente. Conclusões: Os custos anuais com o manejo da CMH aumentam de acordo com a classe funcional, destacando a necessidade de estratégias seguras e eficazes capazes de melhorar a classe funcional NYHA do paciente, ao mesmo tempo que promove diminuição da necessidade de terapias invasivas.


Assuntos
Cardiomiopatia Hipertrófica , Técnica Delphi , Custos e Análise de Custo , Saúde Suplementar
11.
Front Cardiovasc Med ; 10: 1228305, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38028447

RESUMO

Background: Periprocedural myocardial injury (PPMI) frequently occurs after transcatheter aortic valve implantation (TAVI), although its impact on long-term mortality is uncertain. Methods: We performed a pooled analysis of Kaplan-Meier-derived individual patient data to compare survival in patients with and without PPMI after TAVI. Flexible parametric models with B-splines and landmark analyses were used to determine PPMI prognostic value. Subgroup analyses for VARC-2, troponin, and creatine kinase-MB (CK-MB)-defined PPMI were also performed. Results: Eighteen observational studies comprising 10,094 subjects were included. PPMI was associated with lower overall survival (OS) after two years (HR = 1.46, 95% CI 1.30-1.65, p < 0.01). This was also observed when restricting the analysis to overall VARC-2-defined PPMI (HR = 1.23, 95% CI 1.07-1.40, p < 0.01). For VARC-2 PPMI criteria and VARC-2 troponin-only, higher mortality was restricted to the first 2 months after TAVI (HR = 1.64, 95% CI 1.31-2.07, p < 0.01; and HR = 1.32, 95% CI 1.05-1.67, p = 0.02, respectively), while for VARC-2 defined CK-MB-only the increase in mortality was confined to the first 30 days (HR = 7.44, 95% CI 4.76-11.66, p < 0.01). Conclusion: PPMI following TAVI was associated with lower overall survival compared with patients without PPMI. PPMI prognostic impact is restricted to the initial months after the procedure. The analyses were consistent for VARC-2 criteria and for both biomarkers, yet CK-MB was a stronger prognostic marker of mortality than troponin.

12.
Am J Cardiol ; 205: 259-268, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37619492

RESUMO

Sacubitril-valsartan is an angiotensin receptor-neprilysin inhibitor (ARNI) associated with a decreased risk of death and hospitalization for selected patients with heart failure (HF). However, its association with improved atherosclerotic cardiovascular disease (ASCVD) events remains unclear. We performed a meta-analysis to evaluate the association of ARNI with ASCVD events in patients with HF. We systematically searched PubMed, Embase, Cochrane, and ClinicalTrials.gov for studies comparing ARNIs with angiotensin-converting enzyme inhibitors (ACEIs) or angiotensin receptor blockers (ARBs) in terms of myocardial infarction, stroke, angina pectoris, peripheral artery disease, and the composite end point in patients with HF. A total of 8 randomized controlled trials were included, with 17,541 patients assigned to either the ARNI (8,764 patients) or ACEi/ARB (8,777 patients) groups. The incidence of composite end point (risk ratio [RR] 1.03, 95% confidence interval [CI] 0.93 to 1.13, p = 0.63), myocardial infarction (RR 1.02, 95% CI 0.81 to 1.30, p = 0.85), angina pectoris (RR 0.96, 95% CI 0.80 to 1.17, p = 0.70), and stroke (RR 0.99, 95% CI 0.85 to 1.16, p = 0.93) were not statistically different between the ARNI and ACEi/ARB groups. However, ARNI was associated with a higher incidence of peripheral artery disease (RR 1.63, 95% CI 1.05 to 2.52, p = 0.03). In conclusion, this meta-analysis found no association between ARNI therapy and improved ASCVD events in patients with HF.


Assuntos
Aterosclerose , Doenças Cardiovasculares , Insuficiência Cardíaca , Infarto do Miocárdio , Doença Arterial Periférica , Acidente Vascular Cerebral , Humanos , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Antagonistas de Receptores de Angiotensina/uso terapêutico , Neprilisina , Doenças Cardiovasculares/epidemiologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Aterosclerose/tratamento farmacológico , Aterosclerose/epidemiologia , Anti-Hipertensivos , Angina Pectoris , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/epidemiologia , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/epidemiologia , Antivirais
13.
Eur Heart J Acute Cardiovasc Care ; 12(11): 755-764, 2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-37450613

RESUMO

AIMS: Chest pain is a major cause of medical evaluation at emergency department (ED) and demands observation to exclude the diagnosis of acute myocardial infarction (AMI). High-sensitivity cardiac troponin assays used as isolated measure and by 0- and 1-h algorithms are accepted as a rule-in/rule-out strategy, but there is a lack of validation in specific populations. METHODS AND RESULTS: The IN-HOspital Program to systematizE Chest Pain Protocol (IN-HOPE study) is a multicentre study that prospectively included patients admitted to the ED due to suspected symptoms of AMI at 16 sites in Brazil. Medical decisions of all patients followed the standard approach of 0 h/3 h protocol, but, in addition, blood samples were also collected at 0 and 1 h and sent to a central laboratory (core lab) to measure high-sensitivity cardiac troponin T (hs-cTnT). To assess the theoretical performance of 0 h/1 h algorithm, troponin < 12 ng/L with a delta < 3 was considered rule-out while a value ≥ 52 or a delta ≥ 5 was considered a rule-in criterion (the remaining were considered as observation group). The main objective of the study was to assess, in a population managed by the 0 h/3 h protocol, the accuracy of 0 h/1 h algorithm overall and in groups with a higher probability of AMI. All patients were followed up for 30 days, and potential events were adjudicated. In addition to the prospective cohort, a retrospective analysis was performed assessing all patients with hs-cTnT measured during the year of 2021 but not included in the prospective cohort, regardless of the indication of the test. A total of 5.497 patients were included (583 in the prospective and 4.914 in the retrospective analysis). The prospective cohort had a mean age of 57.3 (± 14.8) and 45.6% of females with a mean HEART score of 4.0 ± 2.2. By the core lab analysis, 74.4% would be eligible for a rule-out approach (45.3% of them with a HEART score > 3) while 7.3% would fit the rule-in criteria. In this rule-out group, the negative predictive value for index AMI was 100% (99.1-100) overall and regardless of clinical scores. At 30 days, no death or AMI occurred in the rule-out group of both 0/1 and 0/3 h algorithms while 52.4% of the patients in the rule-in group (0 h/1 h) were considered as AMI by adjudication. In the observation group (grey zone) of 0 h/1 h algorithm, GRACE discriminated the risk of these patients better than HEART score. In the retrospective analysis, 1.091 patients had a troponin value of <5 ng/L and there were no cardiovascular deaths at 30 days in this group. Among all 4.914 patients, the 30-day risk of AMI or cardiovascular death increased according to the level of troponin: 0% in the group < 5 ng/L, 0.6% between 5 and 14 ng/L, 2.2% between 14 and 42 ng/L, 6.3% between 42 and 90 ng/L, and 7.7% in the level ≥ 90 ng/L. CONCLUSION: In this large multicentre study, a 0 h/1 h algorithm had the potential to classify as rule-in or rule-out in almost 80% of the patients. The rule-out protocol had high negative predictive value regardless of clinical risk scores. Categories of levels of hs-cTn T also showed good accuracy in discriminating risk of the patients with a very favourable prognosis for cardiovascular death in the group with value < 5 ng/L. CLINICALTRIALS.GOV: NCT04756362.


Assuntos
Infarto do Miocárdio , Troponina T , Feminino , Humanos , Pessoa de Meia-Idade , Algoritmos , Biomarcadores , Dor no Peito/diagnóstico , Dor no Peito/etiologia , Serviço Hospitalar de Emergência , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/epidemiologia , Estudos Prospectivos , Estudos Retrospectivos , Troponina I , Masculino , Adulto , Idoso
14.
EuroIntervention ; 19(7): 589-599, 2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37436190

RESUMO

BACKGROUND: The optimal timing to perform percutaneous coronary interventions (PCI) in transcatheter aortic valve implantation (TAVI) patients remains unknown. AIMS: We sought to compare different PCI timing strategies in TAVI patients. METHODS: The REVASC-TAVI registry is an international registry including patients undergoing TAVI with significant, stable coronary artery disease (CAD) at preprocedural workup. In this analysis, patients scheduled to undergo PCI before, after or concomitantly with TAVI were included. The main endpoints were all-cause death and a composite of all-cause death, stroke, myocardial infarction (MI) or rehospitalisation for congestive heart failure (CHF) at 2 years. Outcomes were adjusted using the inverse probability treatment weighting (IPTW) method. RESULTS: A total of 1,603 patients were included. PCI was performed before, after or concomitantly with TAVI in 65.6% (n=1,052), 9.8% (n=157) or 24.6% (n=394), respectively. At 2 years, all-cause death was significantly lower in patients undergoing PCI after TAVI as compared with PCI before or concomitantly with TAVI (6.8% vs 20.1% vs 20.6%; p<0.001). Likewise, the composite endpoint was significantly lower in patients undergoing PCI after TAVI as compared with PCI before or concomitantly with TAVI (17.4% vs 30.4% vs 30.0%; p=0.003). Results were confirmed at landmark analyses considering events from 0 to 30 days and from 31 to 720 days. CONCLUSIONS: In patients with severe aortic stenosis and stable coronary artery disease scheduled for TAVI, performance of PCI after TAVI seems to be associated with improved 2-year clinical outcomes compared with other revascularisation timing strategies. These results need to be confirmed in randomised clinical trials.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/complicações , Intervenção Coronária Percutânea/métodos , Estenose da Valva Aórtica/terapia , Infarto do Miocárdio/complicações , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
15.
Front Cardiovasc Med ; 10: 1175600, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37388643

RESUMO

Background: Acute kidney injury (AKI) is frequently observed after transcatheter aortic valve implantation (TAVI). Of note, it is associated with a threefold increase in all-cause and cardiac death. We propose a new non-contrast strategy for evaluating and performing the TAVI procedure that can be especially valuable for patients with aortic stenosis (AS) and chronic kidney disease (CKD) to prevent AKI. Methods: Patients with severe symptomatic AS and CKD stage ≥3a were evaluated for TAVI using four non-contrast imaging modalities for procedural planning: transesophageal echocardiogram (TEE), cardiac magnetic resonance, multidetector computed tomography (MDCT), and aortoiliac CO2 angiography. Patients underwent transfemoral (TF) TAVI using the self-expandable Evolut R/Pro, and the procedures were guided by fluoroscopy and TEE. Contrast MDCT and contrast injection at certain checkpoints during the procedure were used in a blinded fashion to guarantee patient safety. Results: A total of 25 patients underwent TF-TAVI with the zero-contrast technique. The mean age was 79.9 ± 6.1 years, 72% in NYHA class III/IV, with a mean STS-PROM of 3.0% ± 1.5%, and creatinine clearance of 49 ± 7 ml/min. The self-expandable Evolut R and Pro were implanted in 80% and 20% of patients, respectively. In 36% of the cases, the transcatheter heart valve (THV) chosen was one size larger than the one by contrast MDCT, but none of these cases presented adverse events. Device success and the combined safety endpoint (at 30 days) both achieved 92%. Pacemaker implantation was needed in 17%. Conclusion: This pilot study demonstrated that the zero-contrast technique for procedural planning and THV implantation was feasible and safe and might become the preferable strategy for a significant population of CKD patients undergoing TAVR. Future studies with a larger number of patients are still needed to confirm such interesting findings.

16.
Front Cardiovasc Med ; 10: 1197408, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37378406

RESUMO

Introduction: Classical low-flow, low-gradient aortic stenosis (LFLG-AS) is an advanced stage of aortic stenosis, which has a poor prognosis with medical treatment and a high operative mortality after surgical aortic valve replacement (SAVR). There is currently a paucity of information regarding the current prognosis of classical LFLG-AS patients undergoing SAVR and the lack of a reliable risk assessment tool for this particular subset of AS patients. The present study aims to assess mortality predictors in a population of classical LFLG-AS patients undergoing SAVR. Methods: This is a prospective study including 41 consecutive classical LFLG-AS patients (aortic valve area ≤1.0 cm2, mean transaortic gradient <40 mmHg, left ventricular ejection fraction <50%). All patients underwent dobutamine stress echocardiography (DSE), 3D echocardiography, and T1 mapping cardiac magnetic resonance (CMR). Patients with pseudo-severe aortic stenosis were excluded. Patients were divided into groups according to the median value of the mean transaortic gradient (≤25 and >25 mmHg). All-cause, intraprocedural, 30-day, and 1-year mortality rates were evaluated. Results: All of the patients had degenerative aortic stenosis, with a median age of 66 (60-73) years; most of the patients were men (83%). The median EuroSCORE II was 2.19% (1.5%-4.78%), and the median STS was 2.19% (1.6%-3.99%). On DSE, 73.2% had flow reserve (FR), i.e., an increase in stroke volume ≥20% during DSE, with no significant differences between groups. On CMR, late gadolinium enhancement mass was lower in the group with mean transaortic gradient >25 mmHg [2.0 (0.0-8.9) g vs. 8.5 (2.3-15.0) g; p = 0.034), and myocardium extracellular volume (ECV) and indexed ECV were similar between groups. The 30-day and 1-year mortality rates were 14.6% and 43.8%, respectively. The median follow-up was 4.1 (0.3-5.1) years. By multivariate analysis adjusted for FR, only the mean transaortic gradient was an independent predictor of mortality (hazard ratio: 0.923, 95% confidence interval: 0.864-0.986, p = 0.019). A mean transaortic gradient ≤25 mmHg was associated with higher all-cause mortality rates (log-rank p = 0.038), while there was no difference in mortality regarding FR status (log-rank p = 0.114). Conclusions: In patients with classical LFLG-AS undergoing SAVR, the mean transaortic gradient was the only independent mortality predictor in patients with LFLG-AS, especially if ≤25 mmHg. The absence of left ventricular FR had no prognostic impact on long-term outcomes.

17.
Arq. bras. cardiol ; 120(11): e20220496, 2023. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1527782

RESUMO

Resumo As inovações em dispositivos ao longo das últimas décadas proporcionaram uma melhora no diagnóstico e tratamento de pacientes com insuficiência cardíaca. Essas novas ferramentas progressivamente adaptaram-se a estratégias minimamente invasivas e as opções percutâneas multiplicaram-se de forma rápida. No presente artigo revisamos as direções atuais e futuras dos dispositivos utilizados como opções adjuvantes para o diagnóstico e tratamento adjuvante na insuficiência cardíaca crônica, o seu desenvolvimento, mecanismos e estudos mais recentes


Abstract Innovations in devices during the last decade contributed to enhanced diagnosis and treatment of patients with cardiac insufficiency. These tools progressively adapted to minimally invasive strategies with rapid, widespread use. The present article focuses on actual and future directions of device-related diagnosis and treatment of chronic heart failure.

20.
J Cardiol Cases ; 26(3): 181-185, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36091613

RESUMO

Patients presenting with aortic stenosis and atrial fibrillation (AF) undergoing transcatheter aortic valve replacement (TAVR) are commonly at increased risk for stroke and bleeding complications. Concomitant left atrial appendage occlusion (LAAO) after TAVR may be an alternative to oral anticoagulation (OAC).Between 2018 and 2022, 7 consecutive patients who were ineligible for OAC underwent simultaneous TAVR and LAAO. The mean age was 84.9 ±â€¯4.9 years. The mean CHA2DS2-VASc, HAS-BLED, and STS predicted risk of mortality scores were 5.9 ±â€¯0.7, 3.9 ±â€¯1.1, and 8.8 ±â€¯3.4%, respectively. The median follow-up time was 23 (1 to 27) months. All procedures achieved technical success and no adverse events were observed during follow-up. This case series shows that concomitant TAVR and LAAO is feasible and safe among patients with severe aortic stenosis and AF who are deemed ineligible for OAC. Learning objectives: Atrial fibrillation is the most common arrhythmia in the transcatheter aortic valve replacement (TAVR) population. In those who experience major or life-threatening bleeding, mortality is doubled. We report a case series of 7 concomitant left atrial appendage occlusions (LAAO) after TAVR in patients ineligible for oral anticoagulation. All procedures achieved technical success and no adverse events were observed. The simultaneous approach with TAVR and LAAO was feasible and safe in this case series.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA