Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Physiol Rep ; 12(12): e16119, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38898580

RESUMO

Arterial occlusion pressure (AOP) is influenced by the characteristics of the cuff used to measure AOP. Doppler ultrasound was used to measure AOP of the brachial and superficial femoral arteries using straight and curved blood flow restriction cuffs in 21 males and 21 females. Vessel diameter and blood flow were evaluated as independent predictors of AOP. Overall, there were no significant differences in AOP when using the straight and curved cuffs in the brachial (129 mmHg vs. 128 mmHg) or superficial femoral artery (202 mmHg vs. 200 mmHg), respectively. Overall, AOP was greater (p < 0.05) in males than in females in the arm (135 mmHg, 123 mmHg) and leg (211 mmHg, 191 mmHg). Brachial (0.376 mm, 0.323 mm) and superficial femoral (0.547 mm, 0.486 mm) arteries were larger (p = 0.016) in males than in females, respectively. Systolic blood pressure (SBP) and arm circumference were predictive of brachial artery AOP, whereas SBP, diastolic blood pressure, thigh circumference, and vessel diameter were predictive of superficial femoral artery AOP. Straight and curved cuffs are efficacious in the measurement of AOP in the arm and leg. Differences in vessel size may contribute to sex differences in AOP but this requires further investigation.


Assuntos
Artéria Braquial , Artéria Femoral , Masculino , Humanos , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiologia , Artéria Braquial/fisiologia , Artéria Braquial/diagnóstico por imagem , Determinação da Pressão Arterial/métodos , Determinação da Pressão Arterial/instrumentação , Adulto , Pessoa de Meia-Idade , Pressão Sanguínea/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Ultrassonografia Doppler/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Idoso
2.
Front Physiol ; 15: 1359119, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38444762

RESUMO

Few formulas have been used in exercise physiology as extensively as the Fick formula, which calculates the rate of oxygen consumption (i.e., V.O2) as the product of cardiac output (Q.) and the difference in oxygen content in arterial and mixed venous blood (Δav¯O2). Unfortunately, the physiology of maximum V.O2 (V.O2MAX) is often misinterpreted due to a lack of appreciation for the limitations represented by the oft-ignored superscript annotations in the Fick formula. The purpose of this perspective is to explain the meaning of the superscript annotations and highlight how such annotations influence proper interpretation of V.O2MAX physiology with the Fick formula. First, we explain the significance of the overdots above V.O2 and Q., which indicate a measure per unit of time. As we will show, the presence of an overdot above Q. and lack of one above Δav¯O2 denotes they are different types of ratios and should be interpreted in the context of one another-not in contrast to each other as is commonplace. Second, we discuss the significance of the overline above the "v¯" in Δav¯O2, which indicates the venous sample is an average of blood that comes from mixed sources. The mixed nature of the venous sample has major implications for interpreting the influence of oxygen diffusion and blood flow heterogeneity on V.O2MAX. Ultimately, we give recommendations and insights for using the Fick formula to calculate V.O2 and interpret V.O2MAX physiology.

3.
J Strength Cond Res ; 38(5): 873-880, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38241480

RESUMO

ABSTRACT: Vehrs, PR, Reynolds, S, Allen, J, Barrett, R, Blazzard, C, Burbank, T, Hart, H, Kasper, N, Lacey, R, Lopez, D, and Fellingham, GW. Measurements of arterial occlusion pressure using hand-held devices. J Strength Cond Res 38(5): 873-880, 2024-Arterial occlusion pressure (AOP) of the brachial artery was measured simultaneously using Doppler ultrasound (US), a hand-held Doppler (HHDOP), and a pulse oximeter (PO) in the dominant (DOM) and nondominant (NDOM) arms of males ( n = 21) and females ( n = 23) using continuous (CONT) and incremental (INCR) cuff inflation protocols. A mixed-model analysis of variance revealed significant ( p < 0.05) overall main effects between AOP measured using a CONT (115.7 ± 10.9) or INCR (115.0 ± 11.5) cuff inflation protocol; between AOP measured using US (116.3 ± 11.2), HHDOP (115.4 ± 11.2), and PO (114.4 ± 11.2); and between males (120.7 ± 10.6) and females (110.5 ± 9.4). The small overall difference (1.81 ± 3.3) between US and PO measures of AOP was significant ( p < 0.05), but the differences between US and HHDOP and between HHDOP and PO measures of AOP were not significant. There were no overall differences in AOP between the DOM and NDOM arms. Trial-to-trial variance in US measurements of AOP was not significant when using either cuff inflation protocol but was significant when using HHDOP and PO and a CONT cuff inflation protocol. Bland-Altman plots revealed reasonable limits of agreement for both HHDOP and PO measures of AOP. The small differences in US, HHDOP, and PO measurements of AOP when using CONT or INCR cuff inflation protocols are of minimal practical importance. The choice of cuff inflation protocol is one of personal preference. Hand-held Doppler of PO can be used to assess AOP before using blood flow restriction during exercise.


Assuntos
Artéria Braquial , Ultrassonografia Doppler , Humanos , Masculino , Feminino , Artéria Braquial/fisiologia , Artéria Braquial/diagnóstico por imagem , Adulto , Adulto Jovem , Oximetria/instrumentação
4.
Front Physiol ; 14: 1239582, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37664423

RESUMO

Objective: Measurement of arterial occlusion pressure (AOP) is essential to the safe and effective use of blood flow restriction during exercise. Use of a Doppler ultrasound (US) is the "gold standard" method to measure AOP. Validation of a handheld Doppler (HHDOP) device to measure AOP could make the measurement of AOP more accessible to practitioners in the field. The purpose of this study was to determine the accuracy of AOP measurements of the brachial and femoral arteries using an HHDOP. Methods: We simultaneously measured AOP using a "gold standard" US and a HHDOP in the dominant and non-dominant arms (15 males; 15 females) and legs (15 males; 15 females). Results: There were no differences in limb circumference or limb volume in the dominant and non-dominant arms and legs between males and females or between the dominant and non-dominant arms and legs of males and females. The differences between US and HHDOP measures of AOP in the dominant and non-dominant arms and legs were either not significant or small (<10 mmHg) and of little practical importance. There were no sex differences in AOP measurements of the femoral artery (p > 0.60). Bland-Altman analysis yielded an average bias (-0.65 mmHg; -2.93 mmHg) and reasonable limits of agreement (±5.56 mmHg; ±5.58 mmHg) between US and HHDOP measures of brachial and femoral artery AOP, respectively. Conclusion: HHDOP yielded acceptable measures of AOP of the brachial and femoral arteries and can be used to measure AOP by practitioners for the safe and effective use of blood flow restriction. Due to the potential differences in AOP between dominant and non-dominant limbs, AOP should be measured in each limb.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA