Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Cont Lens Anterior Eye ; : 102185, 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38796331

RESUMO

With over a billion adults worldwide currently affected, presbyopia remains a ubiquitous, global problem. Despite over a century of study, the precise mechanism of ocular accommodation and presbyopia progression remains a topic of debate. Accordingly, this narrative review outlines the lenticular and extralenticular components of accommodation together with the impact of age on the accommodative apparatus, neural control of accommodation, models of accommodation, the impact of presbyopia on retinal image quality, and both historic and contemporary theories of presbyopia.

2.
Ophthalmic Physiol Opt ; 43(5): 947-953, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37184092

RESUMO

PURPOSE: Recent evidence suggests that the ciliary muscle apical fibres are most responsive to accommodative load; however, the structure of the ciliary muscle in individuals with accommodative insufficiency is unknown. This study examined ciliary muscle structure in individuals with accommodative insufficiency (AI). We also determined the response of the ciliary muscle to accommodative/vergence therapy and increasing accommodative demands to investigate the muscle's responsiveness to workload. METHODS: Subjects with AI were enrolled and matched by age and refractive error with subjects enrolled in another ciliary muscle study as controls. Anterior segment optical coherence tomography was used to measure the ciliary muscle thickness (CMT) at rest (0D), maximum thickness (CMTMAX) and over the area from 0.75 mm (CMT0.75) to 3 mm (CMT3) posterior to the scleral spur of the right eye. For those with AI, the ciliary muscle was also measured at increasing levels of accommodative demand (2D, 4D and 6D), both before and after accommodative/vergence therapy. RESULTS: Sixteen subjects with AI (mean age = 17.4 years, SD = 8.0) were matched with 48 controls (mean age = 17.8 years, SD = 8.2). On average, the controls had 52-72 µm thicker ciliary muscles in the apical region at 0D than those with AI (p = 0.03 for both CMTMAX and CMT 0.75). Differences in thickness between the groups in other regions of the muscle were not statistically significant. After 8 weeks of accommodative/vergence therapy, the CMT increased by an average of 22-42 µm (p ≤ 0.04 for all), while AA increased by 7D (p < 0.001). CONCLUSIONS: This study demonstrated significantly thinner apical ciliary muscle thickness in those with AI and that the ciliary muscle can thicken in response to increased workload. This may explain the mechanism for improvement in signs and symptoms with accommodative/vergence therapy.


Assuntos
Presbiopia , Erros de Refração , Humanos , Adolescente , Acomodação Ocular , Corpo Ciliar/diagnóstico por imagem , Corpo Ciliar/fisiologia , Músculo Liso
3.
Eye Contact Lens ; 49(6): 219-223, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37022143

RESUMO

OBJECTIVE: To describe the labeling, packaging practices, and characteristics of compounded 0.01% ophthalmic atropine. METHODS: A convenience sample of parents of children who had previously been prescribed low-concentration atropine for myopia management were randomized to obtain 0.01% atropine ophthalmic solution from one of nine compounding pharmacies. The products were analyzed for various important quality attributes. The main outcomes were labeling practices, concentration of atropine and degradant product tropic acid, pH, osmolarity, viscosity, and excipients in 0.01% atropine samples obtained from nine US compounding pharmacies. RESULTS: Twenty-four samples from nine pharmacies were analyzed. The median bottle size was 10 mL (range 3.5-15 mL), and eight of nine pharmacies used clear plastic bottles. Storage recommendations varied and were evenly split between refrigeration (33%), room temperature (33%), and cool, dark, dry location (33%). Beyond use dates ranged from 7 to 175 days (median, 91 days). Median pH of samples was 7.1 (range, 5.5-7.8). Median measured concentration relative to the prescribed concentration was 93.3% (70.4%-104.1%). One quarter of samples were under the 90% minimum target concentration of 0.01%. CONCLUSIONS: An inconsistent and wide variety of formulation and labeling practices exist for compounding 0.01% atropine prescribed to slow pediatric myopia progression.


Assuntos
Atropina , Miopia , Humanos , Criança , Composição de Medicamentos , Soluções Oftálmicas
4.
Eye Contact Lens ; 49(5): 204-211, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-36877990

RESUMO

OBJECTIVES: There is increasing interest in fitting children with soft contact lenses, in part due to the increase in prescribing of designs to slow the progression of myopia. This literature review summarizes large prospective and retrospective studies that include data on the incidence of microbial keratitis and corneal infiltrative events (CIEs) in children wearing soft contact lenses. METHODS: Peer-reviewed prospective and retrospective studies that report contact lens-related complications in children with at least one year of wear and at least 100 patient years of wear were identified. RESULTS: Seven prospective studies published between 2004 and 2022 were identified representing 3,752 patient years of wear in 1,756 children, nearly all of whom were fitted at age 12 years or younger. Collectively, they report one case of microbial keratitis and 53 CIEs, of which 16 were classified as symptomatic. The overall incidence of microbial keratitis was 2.7 per 10,000 patient years (95% CI: 0.5-15), and the incidence of symptomatic CIEs was 42 per 10,000 patient years (95% CI: 26-69). Two retrospective studies were identified representing 2,545 patient years of wear in 1,025 children, fitted at age 12 years or younger. One study reports two cases of microbial keratitis giving an incidence of 9.4 per 10,000 patient years (95% CI: 0.5-15). CONCLUSIONS: Accurate classification of CIEs is challenging, particularly in retrospective studies. The incidence of microbial keratitis in children wearing soft lenses is no higher than in adults, and the incidence of CIEs seems to be markedly lower.


Assuntos
Lentes de Contato Hidrofílicas , Doenças da Córnea , Ceratite , Adulto , Criança , Humanos , Lentes de Contato Hidrofílicas/efeitos adversos , Doenças da Córnea/etiologia , Incidência , Ceratite/epidemiologia , Ceratite/etiologia , Estudos Prospectivos , Estudos Retrospectivos
5.
Ophthalmic Physiol Opt ; 43(3): 534-543, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36919952

RESUMO

PURPOSE: To evaluate the relative efficacy of peripheral defocus contact lenses (PDCLs) and orthokeratology (OK) in a real-world clinical population, and compare these results with previous randomised controlled clinical trials. METHODS: Records from a university practice were reviewed to identify children who were treated with OK or PDCLs. The analysed sample contained 273 visits from 77 patients. Annualised rates of axial length (AL) progression were calculated and used as the response variable in both linear mixed-effects (LME) and nonlinear regression models. RESULTS: On average, children were 10.7 years of age at baseline (p = 0.14 between treatments), and most patients were female. More Asian children wore OK lenses compared with PDCLs (p < 0.01). At baseline, children had ~3.00 D of myopia and 0.75 D of astigmatism in both treatment groups (p > 0.20 between treatments). LME regression models using only baseline covariates showed no evidence that the annualised change in AL differed between treatments, with or without the inclusion of age, race, sex, baseline AL or spherical equivalent refractive error. Across all possible subsets of models, age at baseline was the best predictor of annualised AL change. There was no statistical difference between parameters of an exponential decay model fitted within treatment using follow-up age as a time-varying predictor, indicating that the rate of annualised change in AL was similar for OK and PDCL. CONCLUSIONS: Retrospective analysis of real-world clinical data found no difference in annualised AL growth between PDCL and OK. Importantly, the AL progression from this clinical setting is consistent with that reported in randomised clinical trials. Therefore, continued research of real-world performance is warranted to understand the safety and efficacy of modern myopia control treatments in the broader population.


Assuntos
Lentes de Contato Hidrofílicas , Miopia , Procedimentos Ortoceratológicos , Criança , Humanos , Feminino , Masculino , Estudos Retrospectivos , Refração Ocular , Procedimentos Ortoceratológicos/métodos , Miopia/terapia , Comprimento Axial do Olho
6.
Optom Vis Sci ; 100(2): 145-150, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36728687

RESUMO

SIGNIFICANCE: The U.S. Food and Drug Administration regulates contact lenses as prescription medical devices and defines daily disposable lenses for single use; however, safety comparisons between daily disposable and reusable lenses rely on the lens-wearing regimen. When inappropriately discerned, studies may erroneously report replacement regimen, resulting in inaccurate risk rates. PURPOSE: This study aimed to explore different measures for defining daily disposable wearers in the context of a clinical study. METHODS: A secondary analysis of data from five multisite fieldings (n = 1059) from the Contact Lens Risk Survey was performed. Descriptive statistics were used to examine self-reported lens replacement, use of lens case, and manufacturer's recommended replacement frequency as defined by the participants' selection of their habitual lenses using a photographic aide. Daily disposable wearers were identified as reporting daily replacement (by self-report and lens identification) and not using a lens case. If there was a discrepancy among these three factors, the lens assignment was assessed as a majority response (two of three) or as missing if conflicting information was reported. RESULTS: The cohort was approximately two-thirds (68.7%) female and ranged from 12 to 33 years of age. A total of 154 participants (14.5%) were classified as daily disposable wearers and 896 (84.6%) as reusable wearers. Congruence was observed among all three daily disposable assignment factors for only 106 wearers (68.8%). The greatest discrepancy among daily disposable wearers was the report of using a lens case (n = 32 [20.8%]). In contrast, reusable lens wearers were more likely to report agreement across all three factors (n = 798 [89.1%], P < .001). CONCLUSIONS: This analysis suggests that the report of not using a lens case is a more conservative surrogate for true single-use lens wear, as one in five may be storing and reusing their daily disposable lenses.


Assuntos
Lentes de Contato Hidrofílicas , Cristalino , Humanos , Feminino , Masculino , Equipamentos Descartáveis , Inquéritos e Questionários
7.
Optom Vis Sci ; 100(1): 9-16, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36705710

RESUMO

SIGNIFICANCE: There are limited treatment options for myopia management of patients with moderate to high astigmatism. This work directly compares toric orthokeratology and soft toric multifocal lenses to show differences in visual acuity and patient satisfaction that could impact clinical care. Toric orthokeratology caused reduced visual acuity but was preferred subjectively for vision and overall. PURPOSE: This study aimed to quantify objective and subjective clinical differences between toric orthokeratology and soft toric multifocal contact lenses in the same cohort of myopic wearers with moderate to high astigmatism. METHODS: Thirty adults with refractive myopia (plano to -5.00 D) and astigmatism (1.25 to 3.50 D) were fitted empirically with both toric orthokeratology and soft toric multifocal contact lenses. Participants wore lenses for 10 days in random order, separated by a 14-day washout period. High-contrast visual acuity, low-contrast visual acuity, and glare logMAR visual acuity were measured. Surveys ascertained subject preference for comfort, vision, handling, and cost. Friedman, Wilcoxon signed rank, and χ2 tests were performed. RESULTS: A subset of participants (n = 17) who achieved good vision with both lens types was analyzed. High-contrast and glare acuity with toric orthokeratology were reduced by one line compared with soft toric multifocal lenses (both 0.00 vs. -0.10, P ≤ .003). Participants preferred toric orthokeratology for vision ( P ≤ .03) but soft toric multifocal lenses for handling ( P ≤ .006). When forced to choose between lens types, participants preferred toric orthokeratology for vision and overall (both P ≤ .007). CONCLUSIONS: Participants who achieved good vision with both lens types preferred toric orthokeratology over soft toric multifocal lenses, despite reduced high-contrast and glare visual acuity. Further research is needed to understand the relationship between visual performance and patient satisfaction.


Assuntos
Astigmatismo , Lentes de Contato Hidrofílicas , Miopia , Adulto , Humanos , Astigmatismo/terapia , Acuidade Visual , Refração Ocular , Miopia/terapia
8.
Ophthalmic Physiol Opt ; 43(1): 25-34, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36169043

RESUMO

PURPOSE: To compare objective and subjective digital near visual performance and comfort in low to moderate astigmatic participants fitted with toric versus spherical equivalent silicone hydrogel daily disposable contact lenses. METHODS: This was a double-masked, randomised, crossover study. Participants aged 18 to 39 years with astigmatism of -0.75 to -1.50 D were recruited and fitted with toric and spherical contact lenses, in random order. Outcomes were measured at baseline and after 1 week of wear with each contact lens type after the follow-up visits. High- and low-contrast near logMAR visual acuity, automated visual acuity, zoom (%), contrast (%), reading distance (cm), critical print size (logMAR) and reading speed were assessed. Participants also completed the validated Near Activity Visual Questionnaire (NAVQ) and Contact Lens Dry Eye Questionnaire 8 (CLDEQ-8) for each correction type. RESULTS: Twenty-three participants completed the study (74% female, average age 24.4 ± 4.2 years). When participants wore toric contact lenses, near high- and low-contrast visual acuity and automated visual acuity improved by 3-4 letters (all p < 0.03) and participants were able to read faster on an iPad (p = 0.02). Participants were also able to read with 8% less contrast on the iPad with toric lenses (p = 0.01). Participants reported better subjective vision on the overall NAVQ (p = 0.001) and better comfort on the CLDEQ-8 (p = 0.02) with toric lenses. Fewer participants reported difficulty with maintaining focus at near, reading small print, reading labels/instructions, reading the computer display/keyboard and reading post/mail with toric correction. CONCLUSIONS: Toric contact lenses improve comfort, subjective and objective visual performance with digital devices and other near tasks compared with the spherical equivalent correction in participants with low to moderate astigmatism.


Assuntos
Lentes de Contato , Feminino , Humanos , Adulto Jovem , Adulto , Masculino , Estudos Cross-Over
9.
Ophthalmic Physiol Opt ; 43(2): 202-211, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36464862

RESUMO

PURPOSE: To use the Health Belief Model (HBM) to understand daily disposable (DD) soft contact lens (SCL) wearers' attitudes and beliefs. METHODS: A convenience sample of DD SCL wearers (18-33 years) was enrolled at two sites. Participants were queried about demographics, SCL wear and HBM constructs. Rasch analysis was used to assess the psychometric properties of the survey instrument and generate scores for each HBM subscale. ANOVA was used to determine relationships among HBM constructs, subject demographics and DD SCL-related health behaviours. RESULTS: One hundred people participated (mean ± SD), age = 24.2 ± 3.9 years, 76% female. Thirty-seven percent reported sleeping in DD SCLs and 25% reported reusing DD SCLs. Self-report of reusing DD SCLs was associated with scores on the benefits: reuse (p = 0.02) and barriers (p = 0.007) subscales, and sleeping in lenses was associated with scores on the susceptibility (p = 0.05), benefits: wear behaviours (p = 0.006) and barriers (p = 0.01) subscales. Rasch analysis showed some subscales demonstrated multidimensionality. CONCLUSIONS: Selected health belief constructs were associated with DD SCL-related behaviours including reusing and overnight wear. Increased understanding of SCL attitudes and beliefs could inform patient education and interventions to decrease risks associated with improper SCL wear.


Assuntos
Lentes de Contato Hidrofílicas , Humanos , Feminino , Adulto Jovem , Adulto , Masculino , Inquéritos e Questionários , Autorrelato , Equipamentos Descartáveis , Atitude , Modelo de Crenças de Saúde
10.
J Proteomics ; 270: 104738, 2023 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-36191803

RESUMO

Contact lens-related ocular surface complications occur more often in teenagers and young adults. The purpose of this study was to determine changes in tear proteome of young patients wearing glasses (GL), orthokeratology lenses (OK), and soft contact lenses (SCL). Twenty-two young subjects (10-26 years of age) who were established GL, OK, and SCL wearers were recruited. Proteomic data were collected using a data-independent acquisition-parallel accumulation serial fragmentation workflow. In total, 3406 protein groups were identified, the highest number of proteins identified in Schirmer strip tears to date. Eight protein groups showed higher abundance, and 11 protein groups showed lower abundance in the SCL group compared to the OK group. In addition, the abundance of 82 proteins significantly differed in children compared to young adult GL wearers, among which 67 proteins were higher, and 15 proteins were lower in children. These 82 proteins were involved in inflammation, immune, and glycoprotein metabolic biological processes. In summary, this work identified over 3000 proteins in Schirmer Strip tears. The results indicated that tear proteomes were altered by orthokeratology and soft contact wear and age, which warrants further larger-scale study on the ocular surface responses of teenagers and young adults separately to contact lens wear. SIGNIFICANCE: In this work, we examined the tear proteomes of young patients wearing glasses, orthokeratology lenses, and soft contact lenses using a data-independent acquisition-parallel accumulation serial fragmentation (diaPASEF) workflow and identified 3406 protein groups in Schirmer strip tears. Nineteen protein groups showed significant abundance changes between orthokeratology and soft contact lens wearers. Moreover, eighty-two protein groups significantly differed in abundance in children and young adult glasses wearers. As a pilot study, this work provides a deep coverage of tear proteome and suggests the need to investigate ocular responses to contact lens wear separately for children and young adults.


Assuntos
Lentes de Contato Hidrofílicas , Oftalmopatias , Adulto Jovem , Adolescente , Criança , Humanos , Proteoma/metabolismo , Proteômica , Projetos Piloto , Lágrimas/metabolismo , Oftalmopatias/metabolismo
11.
Clin Exp Optom ; 106(7): 752-758, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-35977531

RESUMO

CLINICAL RELEVANCE: Tear glucose and insulin are responsible for the health of the ocular surface; thus, it is important for clinicians to detect the tear glucose and insulin using point-of-care methods. AIM: To determine if changes in blood glucose and insulin levels following an oral glucose tolerance test are reflected in the tears and to test the association between gene expression and tear insulin and glucose. METHODS: Twenty healthy young adults were enrolled. Basal tears and peripheral blood samples were collected to assess glucose and insulin using a point-of-care glucometer and ELISA assays in fasted subjects, and 1.5 and 3 h after an oral glucose challenge. Conjunctival impression cytology was collected to determine gene expression of insulin receptor (INSR) and glucose transporters (GLUT1 and GLUT4). Changes were examined using non-parametric one-way ANOVA. Spearman tests were conducted to examine associations between variables. RESULTS: Glucose and insulin levels increased 1.5 h after oral glucose in both blood (P < 0.001) and tears (P < 0.049) and returned to near baseline values after 3 h. There was a positive correlation between glucose levels in the blood and tears (rho = 0.57, P < 0.001), but not between blood and tear insulin levels (P = 0.18). Glucose and insulin levels in tears were correlated (rho = 0.32, P = 0.048). Tear glucose concentration at 1.5 h after oral glucose was associated with INSR expression (rho = 0.49, P = 0.03), and there was a trend with GLUT1 (P = 0.06) but not GLUT4. CONCLUSION: Tear glucose reflected blood glucose levels but this correspondence was not observed for insulin. Further studies are required to determine the role of glucose and insulin on the ocular surface in both health and diabetes.


Assuntos
Glucose , Insulina , Adulto Jovem , Humanos , Insulina/metabolismo , Transportador de Glucose Tipo 1/metabolismo , Teste de Tolerância a Glucose , Glucose/metabolismo , Glicemia/metabolismo , Lágrimas/metabolismo , Túnica Conjuntiva
12.
Eye Contact Lens ; 48(12): 489-492, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36083169

RESUMO

OBJECTIVES: Low-concentration atropine is commonly prescribed to slow myopia progression in children but is not Food and Drug Administration-approved for that indication and is only available in the United States from compounding pharmacies. The purpose of this study was to ascertain its reported compounding and labeling in the United States. METHODS: US compounding pharmacies were identified through a survey of eye doctors, social media, conferences, and web search. Twenty-eight pharmacies were identified and contacted through telephone and asked a standard set of questions about their methods to compound and label low-concentration atropine. RESULTS: Twenty-six pharmacies across 19 states provided responses, with 21 answering all nine items (81%) and a mean of 8.7 of nine responses. The most frequently reported bottle size was 5 mL (interquartile range [IQR]: 3.5-10). For storage, 10 pharmacies (38%) recommended refrigeration and 16 (62%) stated room temperature was sufficient. The median beyond-use date provided was 65 days (IQR: 45-158). For preparation, 12 pharmacies (50%) used commercially available 1% solution, 9 (38%) used powdered atropine, 2 (8%) used both, and 1 (4%) stated their approach was proprietary. For the added excipients, 11 (42%) used artificial tears only, 6 (23%) added 0.9% saline only, 7 (27%) used more than one ingredient, and 2 (8%) were proprietary. Only two pharmacies mentioned adding boric acid and two mentioned "pH-adjusted" saline. CONCLUSIONS: There were a wide variety of formulation methods in the United States, which may affect atropine stability and potency. Similarly, there are a wide variety of storage and beyond-use recommendations. Further research is needed to assess how these variations may affect the efficacy and safety of low-concentration atropine and of myopia control.


Assuntos
Atropina , Miopia , Criança , Humanos , Estados Unidos , Miopia/tratamento farmacológico , United States Food and Drug Administration , Progressão da Doença , Soluções Oftálmicas
13.
Invest Ophthalmol Vis Sci ; 63(8): 10, 2022 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-35819285

RESUMO

Purpose: There has been little research on myopia management options for patients with astigmatism. This study quantified changes in peripheral refraction induced by toric orthokeratology (TOK) and soft toric multifocal (STM) contact lenses. Methods: Thirty adults with refractive error of plano to -5.00 D (sphere) and -1.25 to -3.50 D (cylinder) were enrolled. Cycloplegic autorefraction was measured centrally, ±20 degrees, and ±30 degrees from the line of sight nasally (N) and temporally (T) on the retina. Measurements were made at baseline, after 10 ± 2 days of TOK wear (without lenses on eye), and after 10 ± 2 days of STM wear (with lenses on the eyes) and compared with repeated-measures analysis of variance. Results: Compared to baseline, TOK induced a myopic shift in defocus (M) at all locations (all P < 0.01), but STM only induced a myopic shift at 20 T in both eyes and 30 N/T in the left eye (all P < 0.01). TOK resulted in more myopic defocus than STM at all locations (all P < 0.05) except 20 T in the left eye. TOK induced more J0 astigmatism at all locations (all P < 0.02), except 20 N in the right eye; J0 with STM was different than baseline at 20 N in both eyes and 30 N in the right eye (all P < 0.02). TOK induced more J0 astigmatism than STM at all locations (all P < 0.01), except 20 T in the left eye. Differences in J45 astigmatism, when significant, were clinically small. Conclusions: Greater amounts of peripheral myopic defocus and J0 astigmatism were induced by TOK compared to STM, which may influence efficacy for myopia management.


Assuntos
Astigmatismo , Lentes de Contato Hidrofílicas , Miopia , Adulto , Astigmatismo/terapia , Humanos , Miopia/terapia , Refração Ocular , Retina
14.
Eye Contact Lens ; 48(8): 347-354, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35580482

RESUMO

OBJECTIVES: To determine if targeted education can influence the behaviors and scores of soft contact lens (SCL) wearers via the Contact Lens Risk Survey (CLRS). METHODS: This was a multicenter, prospective, case-control study. Cases were symptomatic red eye SCL wearers (age, 18-39 years), and controls were age , sex, and site matched. Participants completed the CLRS and were provided targeted patient education at three time points: baseline, one, and six months. Change in scores and behaviors were analyzed using the Wilcoxon signed rank test. RESULTS: Forty-one cases and 71 controls were analyzed. The mean risk score (mean±SE) from baseline to follow-up improved (reduced) for all participants (-1.96±0.73; P =0.01), mostly driven by the improvement among cases (-2.55±1.32; P =0.05). Case subjects reported a decrease in frequency of wearing lenses while showering (-0.32±0.07; P <0.0001), discarding lens solution (-0.13±0.06; P =0.03), and rinsing lenses with tap water (-0.19±0.08; P =0.02) after targeted education. CONCLUSIONS: Targeted patient education can influence some behaviors of SCL wearers, especially those who experienced a red eye event. Further study is needed to determine how to improve other risk behaviors and whether these changes are sustained long term.


Assuntos
Lentes de Contato Hidrofílicas , Educação de Pacientes como Assunto , Adolescente , Adulto , Estudos de Casos e Controles , Lentes de Contato Hidrofílicas/efeitos adversos , Humanos , Estudos Prospectivos , Fatores de Risco , Adulto Jovem
15.
Curr Eye Res ; 47(6): 832-842, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35317695

RESUMO

PURPOSE: Contact lens complications occur more often in older teenagers and young adults compared to children. This study explored differences in tear proteomics between children and young adults wearing soft contact lens (SCL), orthokeratology or spectacles for >3 years. METHODS: Twelve children and 12 sex- and correction-matched young adults were enrolled. Tears were collected via Schirmer strips for tear proteomic analysis using mass spectrometry. Proteome Discoverer was used for protein identification. Label-Free Quantitation was generated using Scaffold software; Fisher's Exact tests were used to compare proteins by age and correction groups. Generalized linear models were used to assess differences in overall protein levels by age and correction groups. A secondary analysis of proteins presented in >50% of samples of each group was conducted using the R/Bioconductor limma package. RESULTS: There were 385 proteins present only in young adults while 183 were unique in children. There were 528 unique proteins to SCL, 96 to orthokeratology and 149 to spectacle wearers. Based on Fisher's Exact analyses, 126 proteins were higher in young adults than children (all P < 0.048). Forty-seven protein levels were higher in SCL compared to orthokeratology (all P < 0.01), 33 protein levels were higher in SCL compared to spectacles (all P < 0.01), 15 protein levels were higher in orthokeratology compared to spectacle wearers (all P < 0.01). Based on generalized linear models, young adults had higher overall protein levels than children (P = 0.001), SCL had higher protein levels than spectacle wearers (P < 0.001) but no differences were found between orthokeratology and spectacle wearers (P = 0.79). Based on the secondary analysis, only Antileukoproteinase was higher in the young adult orthokeratology group compared to other groups (P < 0.01). CONCLUSIONS: Tear protein type and abundance differ by age and correction. Further research is needed to understand the effects of contact lens correction in children and young adults on the tear proteome.


Assuntos
Lentes de Contato Hidrofílicas , Oftalmopatias , Adolescente , Criança , Oftalmopatias/metabolismo , Óculos , Humanos , Projetos Piloto , Proteoma/metabolismo , Proteômica , Lágrimas/metabolismo , Adulto Jovem
16.
J Med Libr Assoc ; 110(4): 507-512, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37101922

RESUMO

Background: A growing body of research demonstrates that adapting the popular entertainment activity "escape rooms" for educational purposes as an innovative teaching method can improve the learning experience. Escape rooms promote teamwork, encourage analytical thinking, and improve problem solving. Despite the increasing development and use of escape rooms in health sciences programs and academic libraries, there is little literature on the use of this method in health sciences libraries with health professions students. Case Presentation: Staff at a health sciences library collaborated with faculty to incorporate escape rooms into library instruction in a variety of settings (in-person, hybrid, online) and formats (team, individual) with health professions students from various disciplines (optometry, pharmacy, medicine). The escape rooms described in this paper offered unique experiences for students through active learning. Discussion: Important considerations when planning escape rooms for health sciences library instruction include deciding on team-based or individual design, calculating potential costs in time and money, deciding on an in-person, hybrid, or online format, and determining whether grades should be assigned. Escape rooms can be an effective strategy for library instruction in the health sciences, working in multiple formats to bring game-based learning to a variety of health professions students.


Assuntos
Medicina , Farmácia , Estudantes de Ciências da Saúde , Humanos , Aprendizagem Baseada em Problemas , Ocupações em Saúde
17.
Clin Exp Optom ; 105(5): 494-499, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34315357

RESUMO

CLINICAL RELEVANCE: This study evaluates a commercially available conjunctival hyperaemia grading system, providing validation of an important tool for ocular surface research and clinical trials. BACKGROUND: Bulbar conjunctival hyperaemia is a sign of ocular surface inflammation, and proper measurement is essential to clinical care and trials. The aim of this study was to assess the validity and repeatability of an objective grading system in comparison with subjective grading. METHODS: This study was a retrospective, randomised analysis of 300 bulbar conjunctival images that were collected at an academic institution. The images used were de-identified and collected from the Keratograph K5 and Haag-Streit slitlamp. Six investigators graded the images with either a 0.1 or 0.5 unit scaling using a 0-4 Efron grading scale. Three of the investigators also imported the images into the AOS ® Anterior software and graded them objectively. All measurement techniques were assessed for repeatability and comparability to each other. RESULTS: Mean hyperaemia with the objective system (1.1 ± 0.7) was significantly less than the subjective grading (2.0 ± 0.8) (P < 0.001). Both inter- and intra-subject repeatability of the objective system (0.15) was better than the subjective methods (1.70). CONCLUSION: The results showed excellent repeatability of the AOS ® Anterior objective conjunctival hyperaemia grading software, although they were not found to be interchangeable with subjective scores. This system has value in monitoring levels of hyperaemia in contact lens wearers and patients in clinical care and research trials.


Assuntos
Lentes de Contato , Hiperemia , Túnica Conjuntiva , Humanos , Hiperemia/diagnóstico , Estudos Retrospectivos , Software
18.
Ophthalmic Physiol Opt ; 41(4): 726-735, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34076904

RESUMO

PURPOSE: Spherical orthokeratology and soft multifocal contact lenses are commonly used for myopia control and correction, but have been shown to increase spherical aberration, coma and total higher order root mean square (HORMS) aberrations. There are limited myopia control contact lens options for patients with moderate to high astigmatism. The purpose of this study was to quantify changes in higher order aberrations (HOA) in myopic astigmatic eyes fitted with toric orthokeratology (TOK) and soft toric multifocal (STM) contact lenses. METHODS: Ocular wavefront aberrations were measured in both eyes of 30 adult subjects and are reported through the 6th radial order over a 5 mm, dilated pupil. All eyes met refractive criteria of myopia (-5.00 D to plano) and cylinder (-3.50 to -1.25 D). Three measurements were taken at baseline and after 10 ± 2 days of lens wear (TOK, STM). Sixteen subjects achieved logMAR high contrast visual acuity of 0.30 or better in both eyes and were included in this analysis. Repeated measures analysis of variance and post-hoc paired t-tests were used, as appropriate, with Benjamini-Hochberg correction. RESULTS: Higher order root mean square, spherical aberration (C12), and coma RMS (C7, C8) increased with TOK (0.641 [0.222], 0.409 [0.157], 0.426 [0.187] µm, respectively) and STM (0.481 [0.107], 0.223 [0.139], 0.320 [0.130] µm, respectively) from baseline (all p < 0.001). TOK was elevated compared to STM for HORMS (p = 0.03), spherical aberration (p = 0.001) and coma RMS (p = 0.04). CONCLUSIONS: Toric orthokeratology induced more HORMS, spherical aberration and coma RMS than STM in myopic astigmats; however, both lens types showed an increase in HOA compared to baseline, which placed patients outside the age and pupil size matched normative ranges. While the optical changes that accompany these modalities are helpful for myopia management, the induction of HOAs may have unintended consequences on visual performance.


Assuntos
Astigmatismo , Lentes de Contato Hidrofílicas , Miopia , Adulto , Astigmatismo/terapia , Lentes de Contato Hidrofílicas/efeitos adversos , Córnea , Humanos , Miopia/terapia , Refração Ocular
19.
Eye Contact Lens ; 47(7): 420-425, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-34050085

RESUMO

OBJECTIVES: To estimate the incidence of microbial keratitis in children wearing overnight orthokeratology lenses in Moscow, Russia. METHODS: To estimate the number of children wearing overnight orthokeratology lenses in 2018, 1,368 patient records from 13 Doctors Lens clinics were selected at random and extrapolated to the entire patient base. To identify cases of microbial keratitis, all episodes of infiltrative keratitis from Morozovskaya City Children's Clinical Hospital in 2018 were recorded and adjudicated by three experienced ophthalmologists. Incidence was calculated as the number of cases divided by the estimated number of wearers. RESULTS: There were 23,049 overnight orthokeratology fits between 2010 and 2018. Among the 1,368 records surveyed, 1,078 (79%) were younger than 18 years at initial fitting. Based on a 7% or 10% annual discontinuation rate, the estimated number of children wearing lenses in 2018 was 10,307 or 9,422, respectively. During 2018, there were 139 cases of corneal infiltrative keratitis in children and 45 were adjudicated as microbial keratitis (32%). Of these, 20 cases were associated with contact lens wear (44%): 15 soft lens wearers (33%) and 5 overnight orthokeratology wearers (11%). Based on the 5 cases and assuming a 7% or 10% discontinuation rate, the annual incidence is 4.9 (95% confidence interval[CI]: 2.1-11.4) or 5.3 (95% CI: 2.3-12.4) per 10,000 patient years. CONCLUSION: The incidence of microbial keratitis in children wearing overnight orthokeratology is lower than a previous United States study and similar to rates associated with use of daily wear soft contact lenses.


Assuntos
Lentes de Contato Hidrofílicas , Úlcera da Córnea , Ceratite , Criança , Humanos , Incidência , Ceratite/epidemiologia , Ceratite/etiologia , Fatores de Risco , Estados Unidos
20.
Invest Ophthalmol Vis Sci ; 62(5): 7, 2021 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-33909031

RESUMO

Purpose: The International Myopia Institute (IMI) Yearly Digest highlights new research considered to be of importance since the publication of the first series of IMI white papers. Methods: A literature search was conducted for articles on myopia between 2019 and mid-2020 to inform definitions and classifications, experimental models, genetics, interventions, clinical trials, and clinical management. Conference abstracts from key meetings in the same period were also considered. Results: One thousand articles on myopia have been published between 2019 and mid-2020. Key advances include the use of the definition of premyopia in studies currently under way to test interventions in myopia, new definitions in the field of pathologic myopia, the role of new pharmacologic treatments in experimental models such as intraocular pressure-lowering latanoprost, a large meta-analysis of refractive error identifying 336 new genetic loci, new clinical interventions such as the defocus incorporated multisegment spectacles and combination therapy with low-dose atropine and orthokeratology (OK), normative standards in refractive error, the ethical dilemma of a placebo control group when myopia control treatments are established, reporting the physical metric of myopia reduction versus a percentage reduction, comparison of the risk of pediatric OK wear with risk of vision impairment in myopia, the justification of preventing myopic and axial length increase versus quality of life, and future vision loss. Conclusions: Large amounts of research in myopia have been published since the IMI 2019 white papers were released. The yearly digest serves to highlight the latest research and advances in myopia.


Assuntos
Miopia/terapia , Procedimentos Ortoceratológicos/métodos , Qualidade de Vida , Refração Ocular/fisiologia , Progressão da Doença , Humanos , Miopia/classificação , Miopia/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA