1.
Clin Chem Lab Med ; 58(4): 547-559, 2020 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-31940285

RESUMO

Background Electrophoretic methods to detect, characterize and quantify M-proteins play an important role in the management of patients with monoclonal gammopathies (MGs). Significant uncertainty in the quantification and limit of detection (LOD) is documented when M-proteins are <10 g/L. Using spiked sera, we aimed to assess the variability in intact M-protein quantification and LOD across 16 laboratories. Methods Sera with normal, hypo- or hyper-gammaglobulinemia were spiked with daratumumab or elotuzumab, with concentrations from 0.125 to 10 g/L (n = 62) along with a beta-migrating sample (n = 9). Laboratories blindly analyzed samples according to their serum protein electrophoresis (SPEP)/isotyping standard operating procedures. LOD and intra-laboratory percent coefficient of variation (%CV) were calculated and further specified with regard to the method (gel/capillary electrophoresis [CZE]), gating strategy (perpendicular drop [PD]/tangent skimming [TS]), isotyping (immunofixation/immunosubtraction [ISUB]) and manufacturer (Helena/Sebia). Results All M-proteins ≥1 g/L were detected by SPEP. With isotyping the LOD was moderately more sensitive than with SPEP. The intensity of polyclonal background had the biggest negative impact on LOD. Independent of the method used, the intra-laboratory imprecision of M-protein quantification was small (mean CV = 5.0%). Low M-protein concentration and high polyclonal background had the strongest negative impact on intra-laboratory precision. All laboratories were able to follow trend of M-protein concentrations down to 1 g/L. Conclusions In this study, we describe a large variation in the reported LOD for both SPEP and isotyping; overall LOD is most affected by the polyclonal immunoglobulin background. Satisfactory intra-laboratory precision was demonstrated. This indicates that the quantification of small M-proteins to monitor patients over time is appropriate, when subsequent testing is performed within the same laboratory.


Assuntos
Eletroforese das Proteínas Sanguíneas/métodos , Laboratórios Hospitalares/normas , Proteínas do Mieloma/análise , Anticorpos Monoclonais/química , Anticorpos Monoclonais Humanizados/química , Seguimentos , Humanos , Isotipos de Imunoglobulinas/química , Limite de Detecção , Paraproteinemias/diagnóstico
2.
Clin Chem Lab Med ; 58(4): 533-546, 2020 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-31940284

RESUMO

Background Serum protein electrophoresis (SPEP) is used to quantify the serum monoclonal component or M-protein, for diagnosis and monitoring of monoclonal gammopathies. Significant imprecision and inaccuracy pose challenges in reporting small M-proteins. Using therapeutic monoclonal antibody-spiked sera and a pooled beta-migrating M-protein, we aimed to assess SPEP limitations and variability across 16 laboratories in three continents. Methods Sera with normal, hypo- or hypergammaglobulinemia were spiked with daratumumab, Dara (cathodal migrating), or elotuzumab, Elo (central-gamma migrating), with concentrations from 0.125 to 10 g/L (n = 62) along with a beta-migrating sample (n = 9). Provided with total protein (reverse biuret, Siemens), laboratories blindly analyzed samples according to their SPEP and immunofixation (IFE) or immunosubtraction (ISUB) standard operating procedures. Sixteen laboratories reported the perpendicular drop (PD) method of gating the M-protein, while 10 used tangent skimming (TS). A mean percent recovery range of 80%-120% was set as acceptable. The inter-laboratory %CV was calculated. Results Gamma globulin background, migration pattern and concentration all affect the precision and accuracy of quantifying M-proteins by SPEP. As the background increases, imprecision increases and accuracy decreases leading to overestimation of M-protein quantitation especially evident in hypergamma samples, and more prominent with PD. Cathodal migrating M-proteins were associated with less imprecision and higher accuracy compared to central-gamma migrating M-proteins, which is attributed to the increased gamma background contribution in M-proteins migrating in the middle of the gamma fraction. There is greater imprecision and loss of accuracy at lower M-protein concentrations. Conclusions This study suggests that quantifying exceedingly low concentrations of M-proteins, although possible, may not yield adequate accuracy and precision between laboratories.


Assuntos
Eletroforese das Proteínas Sanguíneas/métodos , Laboratórios Hospitalares/normas , Proteínas do Mieloma/análise , Anticorpos Monoclonais/química , Anticorpos Monoclonais Humanizados/química , Humanos , Isotipos de Imunoglobulinas/química , Limite de Detecção , Paraproteinemias/diagnóstico , Reprodutibilidade dos Testes
3.
Clin Chem ; 55(3): 499-504, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19131635

RESUMO

BACKGROUND: The diagnosis of systemic immunoglobulin light-chain (AL) amyloidosis requires demonstration of amyloid deposits in a tissue biopsy and amyloidogenic monoclonal light chains. The optimal strategy to identify the amyloidogenic clone has not been established. We prospectively assessed the diagnostic sensitivity of the serum free light chain (FLC) kappa/lambda ratio, a commercial serum and urine agarose gel electrophoresis immunofixation (IFE), and the high-resolution agarose gel electrophoresis immunofixation (HR-IFE) developed at our referral center in patients with AL amyloidosis, in whom the amyloidogenic light chain was unequivocally identified in the amyloid deposits. METHODS: The amyloidogenic light chain was identified in 121 consecutive patients with AL amyloidosis by immunoelectron microscopy analysis of abdominal fat aspirates and/or organ biopsies. We characterized the monoclonal light chain by using IFE and HR-IFE in serum and urine and the FLC kappa/lambda ratio in serum. We then compared the diagnostic sensitivities of the 3 assays. RESULTS: The HR-IFE of serum and urine identified the amyloidogenic light chain in all 115 patients with a monoclonal gammopathy. Six patients with a biclonal gammopathy were omitted from the statistical analysis. The diagnostic sensitivity of commercial serum and urine IFE was greater than that of the FLC kappa/lambda ratio (96% vs 76%). The combination of serum IFE and the FLC assay detected the amyloidogenic light chain in 96% of patients. The combination of IFE of both serum and urine with the FLC kappa/lambda ratio had a 100% sensitivity. CONCLUSIONS: The identification of amyloidogenic light chains cannot rely on a single test and requires the combination of a commercially available FLC assay with immunofixation of both serum and urine.


Assuntos
Amiloidose/sangue , Amiloidose/urina , Imunoensaio/métodos , Cadeias Leves de Imunoglobulina/sangue , Cadeias Leves de Imunoglobulina/urina , Amiloidose/imunologia , Biomarcadores/sangue , Biomarcadores/urina , Feminino , Humanos , Cadeias Leves de Imunoglobulina/imunologia , Masculino
4.
Clin Chem Lab Med ; 46(8): 1183-8, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18724812

RESUMO

BACKGROUND: To investigate the potential use of Artificial Neural Network (ANN) in the evaluation of serum protein electrophoresis, we set up a multicenter study involving six Italian laboratories. For this purpose, we developed an algorithm named CASPER (Computer Assisted Serum Protein Electrophoresis Recognizer). METHODS: A total of 59,516 samples from the six centers were divided into three groups. Training and validation sets were used to develop the neural network, whereas evaluation set was used to test the performance of CASPER in recognizing abnormal electrophoretic profiles. RESULTS: CASPER showed 93.0% sensitivity and 47.4% specificity. CASPER sensitivity and specificity ranged in the six sites from 88% (site 3) to 97% (site 5) and from 36% (site 6) to 53% (site 3), respectively. Sensitivity for gamma zone was 94.6%, for beta zone 89.7% and for oligoclonal patterns 92.0%. CONCLUSIONS: The sensitivity of the CASPER algorithm does not allow us to recommend its use as a replacement for the visual inspection, but it could be helpful in avoiding accidental misclassifications by the operator. Moreover, the CASPER algorithm may be a useful tool for training operators and students. This study evidenced a high inter-observer variability, which should be addressed in a dedicated study. Data set to train and validate ANNs should contain a huge range and an adequate number of different abnormalities.


Assuntos
Algoritmos , Anticorpos Monoclonais/sangue , Computadores , Eletroforese das Proteínas Sanguíneas , Redes Neurais de Computação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade