Radiol Cardiothorac Imaging ; 6(1): e230107, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38358330

RESUMO

Purpose To achieve ultra-high temporal resolution (approximately 20 msec) in free-breathing, real-time cardiac cine MRI using golden-angle radial sparse parallel (GRASP) reconstruction amplified with view sharing (VS) and k-space-weighted image contrast (KWIC) filtering. Materials and Methods Fourteen pediatric patients with congenital heart disease (mean age [SD], 9 years ± 2; 13 male) and 10 adult patients with arrhythmia (mean age, 62 years ± 8; nine male) who underwent both standard breath-hold cine and free-breathing real-time cine using GRASP were retrospectively identified. To achieve high temporal resolution, each time frame was reconstructed using six radial spokes, corresponding to acceleration factors ranging from 24 to 32. To compensate for loss in spatial resolution resulting from over-regularization in GRASP, VS and KWIC filtering were incorporated. The blur metric, visual image quality scores, and biventricular parameters were compared between clinical and real-time cine images. Results In pediatric patients, the incorporation of VS and KWIC into GRASP (ie, GRASP + VS + KWIC) produced significantly (P < .05) sharper x-y-t (blur metric: 0.36 ± 0.03, 0.41 ± 0.03, 0.48 ± 0.03, respectively) and x-y-f (blur metric: 0.28 ± 0.02, 0.31 ± 0.03, 0.37 ± 0.03, respectively) component images compared with GRASP + VS and conventional GRASP. Only the noise score differed significantly between GRASP + VS + KWIC and clinical cine; all visual scores were above the clinically acceptable (3.0) cutoff point. Biventricular volumetric parameters strongly correlated (R2 > 0.85) between clinical and real-time cine images reconstructed with GRASP + VS + KWIC and were in good agreement (relative error < 6% for all parameters). In adult patients, the visual scores of all categories were significantly lower (P < .05) for clinical cine compared with real-time cine with GRASP + VS + KWIC, except for noise (P = .08). Conclusion Incorporating VS and KWIC filtering into GRASP reconstruction enables ultra-high temporal resolution (approximately 20 msec) without significant loss in spatial resolution. Keywords: Cine, View Sharing, k-Space-weighted Image Contrast Filtering, Radial k-Space, Pediatrics, Arrhythmia, GRASP, Compressed Sensing, Real-Time, Free-Breathing Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Imagem Cinética por Ressonância Magnética , Imageamento por Ressonância Magnética , Adulto , Humanos , Masculino , Criança , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquipneia , Hiperventilação , Arritmias Cardíacas
3.
Magn Reson Med ; 91(5): 1965-1977, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38084397

RESUMO

PURPOSE: To develop a highly-accelerated, real-time phase contrast (rtPC) MRI pulse sequence with 40 fps frame rate (25 ms effective temporal resolution). METHODS: Highly-accelerated golden-angle radial sparse parallel (GRASP) with over regularization may result in temporal blurring, which in turn causes underestimation of peak velocity. Thus, we amplified GRASP performance by synergistically combining view-sharing (VS) and k-space weighted image contrast (KWIC) filtering. In 17 pediatric patients with congenital heart disease (CHD), the conventional GRASP and the proposed GRASP amplified by VS and KWIC (or GRASP + VS + KWIC) reconstruction for rtPC MRI were compared with respect to clinical standard PC MRI in measuring hemodynamic parameters (peak velocity, forward volume, backward volume, regurgitant fraction) at four locations (aortic valve, pulmonary valve, left and right pulmonary arteries). RESULTS: The proposed reconstruction method (GRASP + VS + KWIC) achieved better effective spatial resolution (i.e., image sharpness) compared with conventional GRASP, ultimately reducing the underestimation of peak velocity from 17.4% to 6.4%. The hemodynamic metrics (peak velocity, volumes) were not significantly (p > 0.99) different between GRASP + VS + KWIC and clinical PC, whereas peak velocity was significantly (p < 0.007) lower for conventional GRASP. RtPC with GRASP + VS + KWIC also showed the ability to assess beat-to-beat variation and detect the highest peak among peaks. CONCLUSION: The synergistic combination of GRASP, VS, and KWIC achieves 25 ms effective temporal resolution (40 fps frame rate), while minimizing the underestimation of peak velocity compared with conventional GRASP.


Assuntos
Meios de Contraste , Cardiopatias Congênitas , Humanos , Criança , Imageamento por Ressonância Magnética/métodos , Pulmão , Artéria Pulmonar , Cardiopatias Congênitas/diagnóstico por imagem
4.
Pediatr Radiol ; 54(1): 27-33, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38030850

RESUMO

The United States (US) Food and Drug Administration (FDA) has issued multiple statements and guidelines since 2015 on the topic of thyroid function testing in babies and children through 3 years old after receiving iodinated contrast media for medical imaging exams. In April 2023, the FDA adjusted this recommendation to target babies and young children younger than 4 years of age who have a history of prematurity, very low birth weight, or underlying conditions which affect thyroid gland function, largely in response to solid arguments from expert statements from the American College of Radiology (ACR) which is endorsed by the Society for Pediatric Radiology (SPR), Pediatric Endocrinology Society (PES), and the Society for Cardiovascular Angiography & Intervention (SCAI). Herein we describe our approach and development of a clinical care guideline along with the steps necessary for implementation of the plan including alterations in ordering exams requiring iodinated contrast media, automatic triggering of lab orders, reporting, and follow-up, to address the 2022 FDA guidance statement to monitor thyroid function in children after receiving iodinated contrast media. The newly implemented clinical care guideline at Ann and Robert H. Lurie Children's Hospital of Chicago remains applicable following the 2023 updated recommendation from the FDA. We will track patients less than 3 months of age who undergo thyroid function testing following computed tomography (CT), interventional radiology, and cardiac catheterization exams for which an iodinated contrast media is administered as a clinical care quality initiative.


Assuntos
Planejamento Hospitalar , Iodo , Lactente , Criança , Estados Unidos , Humanos , Pré-Escolar , Glândula Tireoide/diagnóstico por imagem , Meios de Contraste/efeitos adversos , United States Food and Drug Administration , Angiografia , Iodo/efeitos adversos
5.
J Am Coll Radiol ; 20(11S): S351-S381, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-38040460

RESUMO

Pediatric heart disease is a large and diverse field with an overall prevalence estimated at 6 to 13 per 1,000 live births. This document discusses appropriateness of advanced imaging for a broad range of variants. Diseases covered include tetralogy of Fallot, transposition of great arteries, congenital or acquired pediatric coronary artery abnormality, single ventricle, aortopathy, anomalous pulmonary venous return, aortopathy and aortic coarctation, with indications for advanced imaging spanning the entire natural history of the disease in children and adults, including initial diagnosis, treatment planning, treatment monitoring, and early detection of complications. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Assuntos
Doença da Artéria Coronariana , Cardiopatias , Adulto , Criança , Humanos , Diagnóstico Diferencial , Diagnóstico por Imagem/métodos , Sociedades Médicas , Estados Unidos
6.
J Cardiovasc Magn Reson ; 25(1): 61, 2023 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-37932797

RESUMO

BACKGROUND: Chronic graft failure and cumulative rejection history in pediatric heart transplant recipients (PHTR) are associated with myocardial fibrosis on endomyocardial biopsy (EMB). Cardiovascular magnetic resonance imaging (CMR) is a validated, non-invasive method to detect myocardial fibrosis via the presence of late gadolinium enhancement (LGE). In adult heart transplant recipients, LGE is associated with increased risk of future adverse clinical events including hospitalization and death. We describe the prevalence, pattern, and extent of LGE on CMR in a cohort of PHTR and its associations with recipient and graft characteristics. METHODS: This was a retrospective study of consecutive PHTR who underwent CMR over a 6-year period at a single center. Two independent reviewers assessed the presence and distribution of left ventricular (LV) LGE using the American Heart Association (AHA) 17-segment model. LGE quantification was performed on studies with visible fibrosis (LGE+). Patient demographics, clinical history, and CMR-derived volumetry and ejection fractions were obtained. RESULTS: Eighty-one CMR studies were performed on 59 unique PHTR. Mean age at CMR was 14.8 ± 6.2 years; mean time since transplant was 7.3 ± 5.0 years. The CMR indication was routine surveillance (without a clinical concern based on laboratory parameters, echocardiography, or cardiac catheterization) in 63% (51/81) of studies. LGE was present in 36% (29/81) of PHTR. In these LGE + studies, patterns included inferoseptal in 76% of LGE + studies (22/29), lateral wall in 41% (12/29), and diffuse, involving > 4 AHA segments, in 21% (6/29). The mean LV LGE burden as a percentage of myocardial mass was 18.0 ± 9.0%. When reviewing only the initial CMR per PHTR (n = 59), LGE + patients were older (16.7 ± 2.9 vs. 12.8 ± 4.6 years, p = 0.001), with greater time since transplant (8.3 ± 5.4 vs. 5.7 ± 3.9 years, p = 0.041). These patients demonstrated higher LV end-systolic volume index (LVESVI) (34.7 ± 11.7 vs. 28.7 ± 6.1 ml/m2, p = 0.011) and decreased LV ejection fraction (LVEF) (56.2 ± 8.1 vs. 60.6 ± 5.3%, p = 0.015). There were no significant differences in history of moderate/severe rejection (p = 0.196) or cardiac allograft vasculopathy (CAV) (p = 0.709). CONCLUSIONS: LV LGE was present in approximately one third of PHTR, more commonly in older patients with longer time since transplantation. Grafts with LGE have lower LVEF. CMR-derived LGE may aid in surveillance of chronic graft failure in PHTR.


Assuntos
Cardiomiopatias , Transplante de Coração , Adulto , Humanos , Criança , Idoso , Adolescente , Adulto Jovem , Meios de Contraste , Volume Sistólico , Gadolínio , Estudos Retrospectivos , Valor Preditivo dos Testes , Fibrose , Imagem Cinética por Ressonância Magnética/métodos
7.
Pediatr Radiol ; 53(13): 2597-2607, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37882844

RESUMO

BACKGROUND: Four-dimensional flow (4D flow) MRI has become a clinically utilized cardiovascular flow assessment tool. However, scans can be lengthy and may require anesthesia in younger children. Adding compressed sensing can decrease scan time, but its impact on hemodynamic data accuracy needs additional assessment. OBJECTIVE: To compare 4D flow hemodynamics acquired with and without compressed sensing. MATERIALS AND METHODS: Twenty-seven patients (median age: 13 [IQR: 9.5] years) underwent conventional and compressed sensing cardiovascular 4D flow following informed consent. Conventional 4D flow was performed using parallel imaging and an acceleration factor of 2. Compressed sensing 4D flow was performed with an acceleration factor of 7.7. Regions of interest were placed to compare flow parameters in the ascending aorta and main pulmonary artery. Paired Student's t-tests, Wilcoxon signed-rank tests, Bland-Altman plots, and intraclass correlation coefficients were conducted. A P-value of < 0.05 was considered statistically significant. RESULTS: Mean scan acquisition time was reduced by 59% using compressed sensing (3.4 vs. 8.2 min, P < 0.001). Flow quantification was similar for compressed sensing and conventional 4D flow for the ascending aorta net flow: 47 vs. 49 ml/beat (P = 0.28); forward flow: 49 vs. 50 ml/beat (P = 0.07), and main pulmonary artery net flow: 49 vs. 51 ml/beat (P = 0.18); forward flow: 50 vs. 55 ml/beat (P = 0.07). Peak systolic velocity was significantly underestimated by compressed sensing 4D flow in the ascending aorta: 114 vs. 128 cm/s (P < 0.001) and main pulmonary artery: 106 vs. 112 cm/s (P = 0.02). CONCLUSION: For both the aorta and main pulmonary artery, compressed sensing 4D flow provided equivalent net and forward flow values compared to conventional 4D flow but underestimated peak systolic velocity. By reducing scan time, compressed sensing 4D flow may decrease the need for anesthesia and increase scanner output without significantly compromising data integrity.


Assuntos
Cardiopatias , Artéria Pulmonar , Humanos , Criança , Adulto Jovem , Adolescente , Artéria Pulmonar/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Aorta/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Reprodutibilidade dos Testes
8.
J Cardiovasc Comput Tomogr ; 17(5): 295-301, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37625911

RESUMO

Cardiovascular computed tomography (CCT) is rated appropriate by published guidelines for the initial evaluation and follow up of congenital heart disease (CHD) and is an essential modality in cardiac imaging programs for patients of all ages. However, no recommended core competencies exist to guide CCT in CHD imaging training pathways, curricula development, or establishment of a more formal educational platform. To fill this gap, a group of experienced congenital cardiac imagers, intentionally inclusive of adult and pediatric cardiologists and radiologists, was formed to propose core competencies fundamental to the expert-level performance of CCT in pediatric acquired and congenital heart disease and adult CHD. The 2020 SCCT Guideline for Training Cardiology and Radiology Trainees as Independent Practitioners (Level II) and Advanced Practitioners (Level III) in Cardiovascular Computed Tomography (1) for adult imaging were used as a framework to define pediatric and CHD-specific competencies. Established competencies will be immediately relevant for advanced cardiac imaging fellowships in both cardiology and radiology training pathways. Proposed future steps include radiology and cardiology society collaboration to establish provider certification levels, training case-volume recommendations, and continuing medical education (CME) requirements for expert-level performance of CCT in pediatric and adult CHD.


Assuntos
Cardiologia , Cardiopatias Congênitas , Humanos , Criança , Adulto , Cardiopatias Congênitas/diagnóstico por imagem , Valor Preditivo dos Testes , Cardiologia/educação , Técnicas de Imagem Cardíaca , Tomografia Computadorizada por Raios X
9.
Pediatr Radiol ; 53(11): 2180-2187, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37599288

RESUMO

Magnetic resonance imaging (MRI) assessment of hepatic vasculature can be challenging in the setting of liver disease and liver lesions. The widely used hepatobiliary contrast agent gadoxetate is an extracellular contrast agent that provides excellent soft tissue characterization but has limitations as a vascular contrast agent. Ferumoxytol is an iron oxide nanoparticle with superparamagnetic properties that can be used as blood pool contrast agent to provide dedicated vascular assessment. We provide a detailed protocol for evaluation of pediatric liver vasculature using ferumoxytol, after imaging of the parenchyma with gadoxetate. We provide multiple examples and discuss practical considerations when incorporating ferumoxytol into practice.

10.
Ann Biomed Eng ; 51(12): 2802-2811, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37573264

RESUMO

In this paper, we explored the use of deep learning for the prediction of aortic flow metrics obtained using 4-dimensional (4D) flow magnetic resonance imaging (MRI) using wearable seismocardiography (SCG) devices. 4D flow MRI provides a comprehensive assessment of cardiovascular hemodynamics, but it is costly and time-consuming. We hypothesized that deep learning could be used to identify pathological changes in blood flow, such as elevated peak systolic velocity ([Formula: see text]) in patients with heart valve diseases, from SCG signals. We also investigated the ability of this deep learning technique to differentiate between patients diagnosed with aortic valve stenosis (AS), non-AS patients with a bicuspid aortic valve (BAV), non-AS patients with a mechanical aortic valve (MAV), and healthy subjects with a normal tricuspid aortic valve (TAV). In a study of 77 subjects who underwent same-day 4D flow MRI and SCG, we found that the [Formula: see text] values obtained using deep learning and SCGs were in good agreement with those obtained by 4D flow MRI. Additionally, subjects with non-AS TAV, non-AS BAV, non-AS MAV, and AS could be classified with ROC-AUC (area under the receiver operating characteristic curves) values of 92%, 95%, 81%, and 83%, respectively. This suggests that SCG obtained using low-cost wearable electronics may be used as a supplement to 4D flow MRI exams or as a screening tool for aortic valve disease.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Aprendizado Profundo , Dispositivos Eletrônicos Vestíveis , Humanos , Valva Aórtica/diagnóstico por imagem , Estudos Retrospectivos , Estenose da Valva Aórtica/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Hemodinâmica
11.
Pediatr Radiol ; 53(5): 900-909, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36879047

RESUMO

BACKGROUND: With improved life expectancy following Fontan palliation, there is an increasing population of patients with a total cavopulmonary connection. However, there is a poor understanding of which patients will experience Fontan failure and when. 4D flow MRI has identified several metrics of clinical interest, but longitudinal studies investigating hemodynamics in Fontan patients are lacking. OBJECTIVE: We aimed to investigate the relationship between flow distribution to the pulmonary arteries and regional hemodynamic metrics in a unique cohort with follow-up 4D flow MRI. MATERIALS AND METHODS: Patients with > 6 months of 4D flow MRI follow-up were included. Flow distribution from the caval veins to pulmonary arteries was measured in addition to regional measures of peak velocity, viscous energy loss (ELmean and ELtot), and kinetic energy. RESULTS: Ten patients with total cavopulmonary connection (17.7 ± 8.8 years at baseline, follow-up: 4.4 ± 2.6 years) were included. Five subjects had unequal flow distribution from the IVC to the pulmonary arteries at baseline. Over time, these subjects tended to have larger increases in peak velocity (39.2% vs 6.6%), ELmean (11.6% vs -38.3%), ELtot (9.5% vs -36.2%), and kinetic energy (96.1% vs 36.3%) in the IVC. However, these differences were statistically insignificant. We found that changes in ELmean and ELtot were significantly associated with changes in peak velocity in the caval veins (R2 > 0.5, P < 0.001). CONCLUSION: Unequal flow distribution from the IVC may drive increasing peak velocities and viscous energy losses, which have been associated with worse clinical outcomes. Changes in peak velocity may serve as a surrogate measure for changes in viscous energy loss.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Humanos , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Hemodinâmica , Imageamento por Ressonância Magnética
12.
Children (Basel) ; 10(2)2023 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-36832400

RESUMO

BACKGROUND: Beta thalassemia major (Beta-TM) is an inherited condition which presents at around two years of life. Patients with Beta-;TM may develop cardiac iron toxicity secondary to transfusion dependence. Cardiovascular magnetic resonance (CMR) T2*, a technique designed to quantify myocardial iron deposition, is a driving component of disease management. A decreased T2* value represents increasing cardiac iron overload. The clinical manifestation is a decline in ejection fraction (EF). However, there may be early subclinical changes in cardiac function that are not detected by changes in EF. CMR-derived strain assesses myocardial dysfunction prior to decline in EF. Our primary aim was to assess the correlation between CMR strain and T2* in the Beta-TM population. METHODS: Circumferential and longitudinal strain was analyzed. Pearson's correlation was calculated for T2* values and strain in the Beta-TM population. RESULTS: We identified 49 patients and 18 controls. Patients with severe disease (low T2*) were found to have decreased global circumferential strain (GCS) in comparison to other T2* groups. A correlation was identified between GCS and T2* (r = 0.5; p < 0.01). CONCLUSION: CMR-derived strain can be a clinically useful tool to predict early myocardial dysfunction in Beta-TM.

13.
J Cardiovasc Magn Reson ; 25(1): 3, 2023 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-36698129

RESUMO

BACKGROUND: Bicuspid aortic valve (BAV) disease is associated with increased risk of aortopathy. In addition to current intervention guidelines, BAV mediated changes in aortic 3D hemodynamics have been considered as risk stratification measures. We aimed to evaluate the association of 4D flow cardiovascular magnetic resonance (CMR) derived voxel-wise aortic reverse flow with aortic dilation and to investigate the role of aortic valve regurgitation (AR) and stenosis (AS) on reverse flow in systole and diastole. METHODS: 510 patients with BAV (52 ± 14 years) and 120 patients with trileaflet aortic valve (TAV) (61 ± 11 years) and mid-ascending aorta diameter (MAAD) > 35 mm who underwent CMR including 4D flow CMR were retrospectively included. An age and sex-matched healthy control cohort (n = 25, 49 ± 12 years) was selected. Voxel-wise reverse flow was calculated in the aorta and quantified by the mean reverse flow in the ascending aorta (AAo) during systole and diastole. RESULTS: BAV patients without AS and AR demonstrated significantly increased systolic and diastolic reverse flow (222% and 13% increases respectively, p < 0.01) compared to healthy controls and also had significantly increased systolic reverse flow compared to TAV patients with aortic dilation (79% increase, p < 0.01). In patients with isolated AR, systolic and diastolic AAo reverse flow increased significantly with AR severity (c = - 83.2 and c = - 205.6, p < 0.001). In patients with isolated AS, AS severity was associated with an increase in both systolic (c = - 253.1, p < 0.001) and diastolic (c = - 87.0, p = 0.02) AAo reverse flow. Right and left/right and non-coronary fusion phenotype showed elevated systolic reverse flow (> 17% increase, p < 0.01). Right and non-coronary fusion phenotype showed decreased diastolic reverse flow (> 27% decrease, p < 0.01). MAAD was an independent predictor of systolic (p < 0.001), but not diastolic, reverse flow (p > 0.1). CONCLUSION: 4D flow CMR derived reverse flow associated with BAV was successfully captured even in the absence of AR or AS and in comparison to TAV patients with aortic dilation. Diastolic AAo reverse flow increased with AR severity while AS severity strongly correlated with increased systolic reverse flow in the AAo. Additionally, increasing MAAD was independently associated with increasing systolic AAo reverse flow. Thus, systolic AAo reverse flow may be a valuable metric for evaluating disease severity in future longitudinal outcome studies.


Assuntos
Doenças da Aorta , Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Humanos , Estudos Transversais , Estudos Retrospectivos , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/diagnóstico por imagem , Dilatação , Valor Preditivo dos Testes , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Estenose da Valva Aórtica/patologia , Doenças da Aorta/complicações , Hemodinâmica , Espectroscopia de Ressonância Magnética
14.
J Magn Reson Imaging ; 58(2): 486-495, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36354274

RESUMO

BACKGROUND: In Duchenne muscular dystrophy (DMD), the right ventricle (RV) tends to be relatively well preserved, but characterization remains difficult due to its complex architecture. Tissue phase mapping (TPM) is a phase contrast cine MRI technique that allows for multidirectional assessment of myocardial velocities. PURPOSE: To use TPM to elucidate relationships between myocardial structure, function, and clinical variables in DMD. STUDY TYPE: Retrospective. SUBJECTS: A total of 20 patients with muscular dystrophy (median age: 16 years); 18 age-matched normal controls (median age: 15 years). FIELD STRENGTH/SEQUENCE: Three-directional velocity encoded cine gradient echo sequence (TPM) at 1.5 T, balanced steady-state free procession (bSSFP), T1 mapping with extracellular volume (ECV), and late gadolinium enhancement (LGE). ASSESSMENT: TPM in basal, mid, and apical short-axis planes was performed as part of a standard MRI study with collection of clinical data. Radial, circumferential, and longitudinal velocities (Vr, Vφ, and Vz, respectively) and corresponding time to peak (TTP) velocities were quantified from TPM and used to calculate RV twist as well as intraventricular and interventricular dyssynchrony. The correlations between TPM velocities, myocardial structure/function, and clinical variables were assessed. STATISTICAL TEST: Unpaired t-test, Wilcoxon rank-sum test, Bland-Altman analyses were used for comparisons between DMD patients and controls and between DMD subgroups. Pearson's test was used for correlations (r). Significance level: P < 0.05. RESULTS: Compared to controls, DMD patients had preserved RV ejection fraction (RVEF 53% ± 8%) but significantly increased interventricular dyssynchrony (Vφ: 0.49 ± 0.21 vs. 0.72 ± 0.17). Within the DMD cohort, RV dyssynchrony significantly increased with lower LV ejection fraction (intraventricular Vr and Vz: r = -0.49; interventricular Vz: r = 0.48). In addition, RV intraventricular dyssynchrony significantly increased with older age (Vz: r = 0.67). DATA CONCLUSION: RV remodeling in DMD occurs in the context of preserved RVEF. Within DMD, this abnormal RV deformation is associated with older age and decreased LVEF. EVIDENCE LEVEL: 4. TECHNICAL EFFICACY: Stage 2.


Assuntos
Cardiopatias , Distrofia Muscular de Duchenne , Humanos , Adolescente , Distrofia Muscular de Duchenne/diagnóstico por imagem , Estudos Retrospectivos , Meios de Contraste , Remodelação Ventricular , Gadolínio , Imageamento por Ressonância Magnética/métodos , Volume Sistólico , Função Ventricular Esquerda , Imagem Cinética por Ressonância Magnética/métodos
15.
J Am Coll Radiol ; 19(11S): S240-S255, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36436955

RESUMO

Childhood ataxia may be due to multifactorial causes of impairment in the coordination of movement and balance. Acutely presenting ataxia in children may be due to infectious, inflammatory, toxic, ischemic, or traumatic etiology. Intermittent or episodic ataxia in children may be manifestations of migraine, benign positional vertigo, or intermittent metabolic disorders. Nonprogressive childhood ataxia suggests a congenital brain malformation or early prenatal or perinatal brain injury, and progressive childhood ataxia indicates inherited causes or acquired posterior fossa lesions that result in gradual cerebellar dysfunction. CT and MRI of the central nervous system are the usual modalities used in imaging children presenting with ataxia, based on the clinical presentation. This document provides initial imaging guidelines for a child presenting with acute ataxia with or without a history of recent trauma, recurrent ataxia with interval normal neurological examination, chronic progressive ataxia, and chronic nonprogressive ataxia. The ACR Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances in which peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Assuntos
Meios de Contraste , Sociedades Médicas , Humanos , Criança , Medicina Baseada em Evidências , Ataxia/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
16.
Children (Basel) ; 9(9)2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36138640

RESUMO

Myocardial stress perfusion magnetic resonance imaging is a non-invasive tool to assess for myocardial ischemia and viability. Pediatric myocardial stress perfusion MRI can be challenging due to multiple intravenous lines, sedation, inadequate breath holding, fast heart rates, and complex anatomy. We performed a retrospective analysis in 39 children to evaluate safety and efficacy of regadenoson, a coronary vasodilator administered via a single intravenous line (6−10 mcg/kg), with respiratory motion correction (MOCO) and semi-quantitative blood flow analysis. Stress response data and adverse events were recorded, and image quality compared between native and MOCO reconstructions, assessing for perfusion deficits. Semi-quantitative analysis compared myocardial perfusion reserve index (MPRI) between patients who had a focal perfusion defect, patients who had undergone an orthotopic heart transplant, and non-transplant patients with no focal defects. Stress perfusion was completed in 38/39 patients (median age 15 years with a 41 ± 27% rise in heart rate (p < 0.005). Fifteen out of thirty-eight had transient minor side effects with no major adverse events. MOCO image quality was better than non-MOCO (4.63 vs. 4.01 at rest, p < 0.005: 4.41 vs. 3.84 at stress, p < 0.005). Reversible perfusion defects were seen in 4/38 patients with lower segmental mean MPRI in the area of the perfusion defect, nearing statistical significance when compared to non-transplant patients with no defects (0.78 ± 0.22 vs. 0.99 ± 0.36, p = 0.07). The global MPRI of the 16 patients who had undergone orthotopic heart transplant was significantly lower than the non-transplant patients (0.75 ± 0.22 vs. 0.92 ± 0.23, p = 0.03). Regadenoson is a safe and effective coronary vasodilator for pediatric stress perfusion MRI with MOCO producing better image quality and allowing for semi-quantitative assessment of perfusion deficits that correlate with qualitative assessment.

17.
Diagn Interv Imaging ; 103(9): 418-426, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35523699

RESUMO

PURPOSE: The purpose of this study was to investigate the relationships between hemodynamic parameters and longitudinal changes in aortic dimensions on four-dimensional (4D) flow magnetic resonance imaging (MRI) in patients with bicuspid aortic valve (BAV) and repaired coarctation. MATERIALS AND METHODS: The study retrospectively included patients with BAV and childhood coarctation repair who had at least two cardiothoracic MRI examinations including 4D flow MRI at baseline and follow-up. Analysis included the calculation of aortic peak velocities, wall shear stress (WSS), pulse wave velocity (PWV), aortic dimensions and annual growth rates. Differences between examinations were assessed using paired t-test or Wilcoxon signed rank test. Relationships between growth rate and 4D flow metrics were assessed using Pearson or Spearman correlation tests. RESULTS: The cohort included 15 patients (mean age 35 ± 8 [SD] years, 9 men) with a median follow-up time of 3.98 years (Q1: 2.10; Q3: 4.96). There were no significant differences in aortic mean WSS, peak velocities, and PWV between baseline and follow-up values. Greater baseline peak velocities at the site of the coarctation were strongly associated with aortic narrowing (follow-up vs. baseline diameter) at coarctation zone (r = -0.64; P = 0.010) and moderately in descending aorta (r = -0.53; P = 0.042). In addition, increased baseline WSS in the aortic arch was strongly related with narrowing of the coarctation zone at follow-up (r = -0.64, P = 0.011). CONCLUSION: Measures of aortic hemodynamics and aortic WSS are stable over time in patients with BAV with coarctation repair. Increased peak velocity was associated with a progressive narrowing at the site of the coarctation repair.


Assuntos
Coartação Aórtica , Doença da Válvula Aórtica Bicúspide , Adulto , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Criança , Seguimentos , Hemodinâmica , Humanos , Imageamento por Ressonância Magnética , Masculino , Análise de Onda de Pulso , Estudos Retrospectivos
18.
J Am Coll Radiol ; 19(5S): S121-S136, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35550797

RESUMO

Imaging plays an integral role in the evaluation of suspected musculoskeletal infections in children, not only in the accurate identification of infection such as osteomyelitis or septic arthritis, but also in guiding management. Various diagnostic modalities serve different purposes in the assessment of suspected pediatric musculoskeletal infections. The purpose of this document is to provide imaging guidance in the most frequently encountered clinical scenarios in which osteomyelitis and/or septic arthritis are suspected, outside of the axial skeleton. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion.


Assuntos
Artrite Infecciosa , Osteomielite , Artrite Infecciosa/diagnóstico por imagem , Criança , Medicina Baseada em Evidências , Humanos , Osteomielite/diagnóstico por imagem , Esqueleto , Sociedades Médicas , Estados Unidos
19.
J Am Coll Radiol ; 19(5S): S19-S36, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35550801

RESUMO

Crohn disease is an inflammatory condition of the gastrointestinal tract with episodes of exacerbation and remission occurring in children, adolescents, and adults. Crohn disease diagnosis and treatment depend upon a combination of clinical, laboratory, endoscopic, histological, and imaging findings. Appropriate use of imaging provides critical information in the settings of diagnosis, assessment of acute symptoms, disease surveillance, and therapy monitoring. Four variants are discussed. The first variant discusses the initial imaging for suspected Crohn disease before established diagnosis. The second variant pertains to appropriateness of imaging modalities during suspected acute exacerbation. The third variant is a substantial discussion of recommendations related to disease surveillance and monitoring of Crohn disease. Finally, panel recommendations and discussion of perianal fistulizing disease imaging completes the document. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.


Assuntos
Doença de Crohn , Adolescente , Doença de Crohn/diagnóstico por imagem , Diagnóstico Diferencial , Diagnóstico por Imagem , Medicina Baseada em Evidências , Humanos , Sociedades Médicas , Estados Unidos
20.
Magn Reson Med ; 88(1): 449-463, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35381116

RESUMO

PURPOSE: To develop a convolutional neural network (CNN) for the robust and fast correction of velocity aliasing in 4D-flow MRI. METHODS: This study included 667 adult subjects with aortic 4D-flow MRI data with existing velocity aliasing (n = 362) and no velocity aliasing (n = 305). Additionally, 10 controls received back-to-back 4D-flow scans with systemically varied velocity-encoding sensitivity (vencs) at 60, 100, and 175 cm/s. The no-aliasing data sets were used to simulate velocity aliasing by reducing the venc to 40%-70% of the original, alongside a ground truth locating all aliased voxels (153 training, 152 testing). The 152 simulated and 362 existing aliasing data sets were used for testing and compared with a conventional velocity antialiasing algorithm. Dice scores were calculated to quantify CNN performance. For controls, the venc 175-cm/s scans were used as the ground truth and compared with the CNN-corrected venc 60 and 100 cm/s data sets RESULTS: The CNN required 176 ± 30 s to perform compared with 162 ± 14 s for the conventional algorithm. The CNN showed excellent performance for the simulated data compared with the conventional algorithm (median range of Dice scores CNN: [0.89-0.99], conventional algorithm: [0.84-0.94], p < 0.001, across all simulated vencs) and detected more aliased voxels in existing velocity aliasing data sets (median detected CNN: 159 voxels [31-605], conventional algorithm: 65 [7-417], p < 0.001). For controls, the CNN showed Dice scores of 0.98 [0.95-0.99] and 0.96 [0.87-0.99] for venc = 60 cm/s and 100 cm/s, respectively, while flow comparisons showed moderate-excellent agreement. CONCLUSION: Deep learning enabled fast and robust velocity anti-aliasing in 4D-flow MRI.


Assuntos
Aprendizado Profundo , Imageamento Tridimensional , Adulto , Velocidade do Fluxo Sanguíneo , Humanos , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS