J Pediatr Gastroenterol Nutr ; 74(S1 Suppl 1): S3-S15, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34402484

RESUMO

INTRODUCTION: Pediatric-specific quality standards for endoscopy are needed to define best practices, while measurement of associated indicators is critical to guide quality improvement. The international Pediatric Endoscopy Quality Improvement Network (PEnQuIN) working group was assembled to develop and define quality standards and indicators for pediatric gastrointestinal endoscopic procedures through a rigorous guideline consensus process. METHODS: The Appraisal of Guidelines for REsearch and Evaluation (AGREE) II instrument guided PEnQuIN members, recruited from 31 centers of various practice types representing 11 countries, in generating and refining proposed quality standards and indicators. Consensus was sought via an iterative online Delphi process, and finalized at an in-person conference. Quality of evidence and strength of recommendations were rated according to the GRADE (Grading of Recommendation Assessment, Development, and Evaluation) approach. RESULTS: Forty-nine quality standards and 47 indicators reached consensus, encompassing pediatric endoscopy facilities, procedures, endoscopists, and the patient experience. The evidence base for PEnQuIN standards and indicators was largely adult-based and observational, and downgraded for indirectness, imprecision, and study limitations to "very low" quality, resulting in "conditional" recommendations for most standards (45/49). CONCLUSIONS: The PEnQuIN guideline development process establishes international agreement on clinically meaningful metrics that can be used to promote safety and quality in endoscopic care for children. Through PEnQuIN, pediatric endoscopists and endoscopy services now have a framework for auditing, providing feedback, and ultimately, benchmarking performance. Expansion of evidence and prospective validation of PEnQuIN standards and indicators as predictors of clinically relevant outcomes and high-quality pediatric endoscopic care is now a research priority.


Assuntos
Endoscopia Gastrointestinal , Melhoria de Qualidade , Adulto , Criança , Consenso , Humanos
2.
J Pediatr Gastroenterol Nutr ; 74(S1 Suppl 1): S16-S29, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34402485

RESUMO

INTRODUCTION: There is increasing international recognition of the impact of variability in endoscopy facilities on procedural quality and outcomes. There is also growing precedent for assessing the quality of endoscopy facilities at regional and national levels by using standardized rating scales to identify opportunities for improvement. METHODS: With support from the North American and European Societies of Pediatric Gastroenterology Hepatology and Nutrition (NASPGHAN and ESPGHAN), an international working group of the Pediatric Endoscopy Quality Improvement Network (PEnQuIN) used the methodological strategy of the Appraisal of Guidelines for REsearch and Evaluation (AGREE) II instrument to develop standards and indicators relevant for assessing the quality of facilities where endoscopic care is provided to children. Consensus was reached via an iterative online Delphi process and subsequent in-person meeting. The quality of evidence and strength of recommendations were rated according to the GRADE (Grading of Recommendation Assessment, Development and Evaluation) approach. RESULTS: The PEnQuIN working group achieved consensus on 27 standards for facilities supporting pediatric endoscopy, as well 10 indicators that can be used to identify high-quality endoscopic care in children. These standards were subcategorized into three subdomains: Quality of Clinical Operations (15 standards, 5 indicators); Patient and Caregiver Experience (9 standards, 5 indicators); and Workforce (3 standards). DISCUSSION: The rigorous PEnQuIN process successfully yielded standards and indicators that can be used to universally guide and measure high-quality facilities for procedures around the world where endoscopy is performed in children. It also underscores the current paucity of evidence for pediatric endoscopic care processes, and the need for research into this clinical area.


Assuntos
Gastroenterologia , Melhoria de Qualidade , Criança , Consenso , Endoscopia Gastrointestinal/métodos , Humanos
3.
J Pediatr Gastroenterol Nutr ; 74(S1 Suppl 1): S30-S43, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34402486

RESUMO

INTRODUCTION: High-quality pediatric gastrointestinal procedures are performed when clinically indicated and defined by their successful performance by skilled providers in a safe, comfortable, child-oriented, and expeditious manner. The process of pediatric endoscopy begins when a plan to perform the procedure is first made and ends when all appropriate patient follow-up has occurred. Procedure-related standards and indicators developed to date for endoscopy in adults emphasize cancer screening and are thus unsuitable for pediatric medicine. METHODS: With support from the North American and European Societies of Pediatric Gastroenterology Hepatology and Nutrition (NASPGHAN and ESPGHAN), an international working group of the Pediatric Endoscopy Quality Improvement Network (PEnQuIN) used the methodological strategy of the Appraisal of Guidelines for REsearch and Evaluation (AGREE) II instrument to develop standards and indicators relevant for assessing the quality of endoscopic procedures. Consensus was sought via an iterative online Delphi process and finalized at an in-person conference. The quality of evidence and strength of recommendations were rated according to the GRADE (Grading of Recommendation Assessment, Development, and Evaluation) approach. RESULTS: The PEnQuIN working group achieved consensus on 14 standards for pediatric endoscopic procedures, as well as 30 indicators that can be used to identify high-quality procedures. These were subcategorized into three subdomains: Preprocedural (3 standards, 7 indicators), Intraprocedural (8 standards, 18 indicators), and Postprocedural (3 standards, 5 indicators). A minimum target for the key indicator, "rate of adequate bowel preparation," was set at ≥80%. DISCUSSION: It is recommended that all facilities and individual providers performing pediatric endoscopy worldwide initiate and engage with the procedure-related standards and indicators developed by PEnQuIN to identify gaps in quality and drive improvement.


Assuntos
Gastroenterologia , Melhoria de Qualidade , Adulto , Criança , Consenso , Endoscopia Gastrointestinal/métodos , Humanos
4.
J Pediatr Gastroenterol Nutr ; 74(S1 Suppl 1): S44-S52, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34402487

RESUMO

INTRODUCTION: High-quality pediatric endoscopy requires reliable performance of procedures by competent individual providers who consistently uphold all standards determined to assure optimal patient outcomes. Establishing consensus expectations for ongoing monitoring and assessment of individual pediatric endoscopists is a method for confirming the highest possible quality of care for such procedures worldwide. We aim to provide guidance to define and measure quality of endoscopic care for children. METHODS: With support from the North American and European Societies of Pediatric Gastroenterology Hepatology and Nutrition (NASPGHAN and ESPGHAN), an international working group of the Pediatric Endoscopy Quality Improvement Network (PEnQuIN) used the methodological strategy of the Appraisal of Guidelines for REsearch and Evaluation (AGREE) II instrument to develop standards and indicators relevant for assessing the quality of endoscopists. Consensus was sought via an iterative online Delphi process and finalized at an in-person conference. The quality of evidence and strength of recommendations were rated according to the GRADE (Grading of Recommendation Assessment, Development, and Evaluation) approach. RESULTS: The PEnQuIN working group achieved consensus on 6 standards that all providers who perform pediatric endoscopy should uphold and 2 standards for pediatric endoscopists in training, with 7 corresponding indicators that can be used to identify high-quality endoscopists. Additionally, these can inform continuous quality improvement at the provider level. Minimum targets for defining high-quality pediatric ileocolonoscopy were set for 2 key indicators: cecal intubation rate (≥90%) and terminal ileal intubation rate (≥85%). DISCUSSION: It is recommended that all individual providers performing or training to perform pediatric endoscopy initiate and engage with these international endoscopist-related standards and indicators developed by PEnQuIN.


Assuntos
Colonoscopia , Melhoria de Qualidade , Ceco , Criança , Colonoscopia/educação , Endoscopia Gastrointestinal , Humanos , Íleo
5.
J Pediatr Gastroenterol Nutr ; 74(S1 Suppl 1): S53-S62, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34402488

RESUMO

INTRODUCTION: High-quality procedure reports are a cornerstone of high-quality pediatric endoscopy as they ensure the clear communication of procedural events and outcomes, guide patient care and facilitate continuous quality improvement. The aim of this document is to outline standardized reporting elements that achieved international consensus as requirements for high-quality pediatric endoscopy procedure reports. METHODS: With support from the North American and European Societies of Pediatric Gastroenterology, Hepatology and Nutrition (NASPGHAN and ESPGHAN), an international working group of the Pediatric Endoscopy Quality Improvement Network (PEnQuIN) used Delphi methodology to identify key elements that should be found in all pediatric endoscopy reports. Item reduction was attained through iterative rounds of anonymized online voting using a 6-point scale. Responses were analyzed after each round and items were excluded from subsequent rounds if ≤50% of panelists rated them as 5 ("agree moderately") or 6 ("agree strongly"). Reporting elements that ≥70% of panelists rated as "agree moderately" or "agree strongly" were considered to have achieved consensus. RESULTS: Twenty-six PEnQuIN group members from 25 centers internationally rated 63 potential reporting elements that were generated from a systematic literature review and the Delphi panelists. The response rates were 100% for all three survey rounds. Thirty reporting elements reached consensus as essential for inclusion within a pediatric endoscopy report. DISCUSSION: It is recommended that the PEnQuIN Reporting Elements for pediatric endoscopy be universally employed across all endoscopists, procedures and facilities as a foundational means of ensuring high-quality endoscopy services, while facilitating quality improvement activities in pediatric endoscopy.


Assuntos
Gastroenterologia , Melhoria de Qualidade , Criança , Consenso , Técnica Delphi , Endoscopia Gastrointestinal , Humanos