Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Materials (Basel) ; 16(11)2023 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-37297290

RESUMO

Despite numerous studies on ion release from orthodontic appliances, no clear conclusions can be drawn due to complex interrelations of multiple factors. Therefore, as the first part of a comprehensive investigation of cytotoxicity of eluted ions, the objective of this study was to analyze four parts of a fixed orthodontic appliance. Specifically, NiTi archwires and stainless steel (SS) brackets, bands, and ligatures were immersed in artificial saliva and studied for morphological and chemical changes after 3-, 7-, and 14-day immersion, using the SEM/EDX technique. Ion release profiles were analyzed for all eluted ions using inductively coupled plasma mass spectrometry (ICP-MS). The results demonstrated dissimilar surface morphologies among parts of the fixed appliance, due to variations in manufacturing processes. The onset of pitting corrosion was observed for the SS brackets and bands in the as-received state. Protective oxide layers were not observed on any of the parts, but adherent layers developed on SS brackets and ligatures during immersion. Salt precipitation, mainly KCl, was also observed. ICP-MS proved to be more sensitive than SEM/EDX and exhibited results undetected by SEM/EDX. Ion release was an order-of-magnitude higher for SS bands compared to other parts, which was attributed to manufacturing procedure (welding). Ion release did not correlate with surface roughness.

2.
Int J Mol Sci ; 24(12)2023 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-37373088

RESUMO

The mechanism of toxicity and cellular response to metal ions present in the environment is still a very current area of research. In this work, which is a continuation of the study of the toxicity of metal ions released by fixed orthodontic appliances, eluates of archwires, brackets, ligatures, and bands are used to test the prooxidant effect, cytotoxicity, and genotoxicity on cell lines of the gastrointestinal tract. Eluates obtained after three immersion periods (3, 7, and 14 days) and with known amounts and types of metal ions were used. Four cell lines-CAL 27 (human tongue), Hep-G2 (liver), AGS (stomach) and CaCo-2 (colon)-were treated with each type of eluate at four concentrations (0.1×, 0.5×, 1.0×, and 2.0×) for 24 h. Most eluates had toxic effects on CAL 27 cells over the entire concentration range regardless of exposure time, while CaCo-2 proved to be the most resistant. In AGS and Hep-G2 cells, all samples tested induced free radical formation, with the highest concentration (2×) causing a decrease in free radicals formed compared to the lowest concentrations. Eluates containing Cr, Mn, and Al showed a slight pro-oxidant effect on DNA (on plasmid φX-174 RF I) and slight genotoxicity (comet assay), but these effects are not so great that the human body could not "resist" them. Statistical analysis of data on chemical composition, cytotoxicity, ROS, genotoxicity, and prooxidative DNA damage shows the influence of metal ions present in some eluates on the toxicity obtained. Fe and Ni are responsible for the production of ROS, while Mn and Cr have a great influence on hydroxyl radicals, which cause single-strand breaks in supercoiled plasmid DNA in addition to the production of ROS. On the other hand, Fe, Cr, Mn, and Al are responsible for the cytotoxic effect of the studied eluates. The obtained results confirm that this type of research is useful and brings us closer to more accurate in vivo conditions.


Assuntos
Níquel , Aparelhos Ortodônticos , Humanos , Células CACO-2 , Espécies Reativas de Oxigênio , Níquel/toxicidade , Metais/toxicidade , Aparelhos Ortodônticos Fixos , Íons/análise , Trato Gastrointestinal/química
3.
Prog Orthod ; 21(1): 17, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32607604

RESUMO

AIM: The study aimed to evaluate to which extent self-reported symptomatology, age, and sex are predictors of titanium and nickel allergic sensitization in patients in treatment with fixed orthodontic appliances. METHODS: The study analyzed 228 subjects aged 11-45 years (median 18, interquartile range 16-22); 68% of them were females, and 52% were adolescents. The allergic sensitization testing included epicutaneous patch test to titanium, titanium dioxide, titanium oxalate, titanium nitride, and nickel sulfate. The questionnaire on symptoms potentially linked to titanium and nickel sensitization was used. RESULTS: Prevalence of the allergic sensitization to titanium in patients undergoing orthodontic treatment was 4% (2% only to titanium without nickel) while to nickel 14% (12% nickel without titanium). Hypersensitivity to both metals at the same time was present in 2% of subjects. Sensitization to nickel was more common in females than in males (17 vs. 8%) and much more common in adults than in adolescents with small effect size (20 vs. 8%; p = 0.013). Sensitization to titanium was more common in females than in males (6 vs. 1%) with no difference in age. Multiple logistic regression analysis revealed that adult age increases the odds for being sensitized to nickel for 2.4 × (95% CI 1.1-5.6; p = 0.044) while watery eyes for 3.7 × (95% CI 1.2-11.1; p = 0.022). None of the symptoms were significant predictors of titanium sensitization. CONCLUSION: Allergic sensitization to titanium and nickel are not very frequent in orthodontic patients, and self-reported symptomatology is a weak predictor of those sensitizations.


Assuntos
Hipersensibilidade , Níquel , Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Aparelhos Ortodônticos , Testes do Emplastro , Titânio , Adulto Jovem
4.
Orthod Craniofac Res ; 23(4): 517-522, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32301238

RESUMO

OBJECTIVE: To assess the prevalence of allergic sensitization to titanium and nickel in orthodontic patients and to evaluate alterations of smell and taste. SUBJECTS AND METHODS: A total of 250 subjects were invited to participate, 245 accepted. The age range was 11-45 years, 68% were females and 52% adolescents. An epicutaneous patch test was performed. Of the positive subjects in the patch test, 26 participated in the taste and smell testing and were matched by age and sex with 26 negative subjects. RESULTS: The prevalence of hypersensitivity to titanium and/or nickel in orthodontic patients was 15.5%. Taste and smell were more impaired in sensitized subjects (P ≤ .025), taste was more affected than smell and the tastes most affected were sour and bitter tastes, while the sweet taste was least impaired. CONCLUSION: The allergic sensitization to titanium is more uncommon than to nickel, with altered smell and taste related to those hypersensitivities.


Assuntos
Níquel , Paladar , Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Níquel/efeitos adversos , Prevalência , Olfato , Titânio/efeitos adversos , Adulto Jovem
5.
Odontology ; 107(2): 150-157, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30178177

RESUMO

The effect of oral antiseptics on the corrosion of nickel-titanium (NiTi) alloys with various coating was investigated. Uncoated, titanium nitride-coated and rhodium-coated NiTi archwires (0.020 × 0.020″) were tested in interaction with artificial saliva pH 4.8 and oral antiseptics based on hyaluronic acid (Gengigel), chlorhexidine (Curasept) and essential oils in alcohol base (Listerine). The dynamics of nickel and titanium ions release were recorded during 28 days. Springback ratio and modulus of resilience were assessed by three-point bending test. The results showed that corrosion of NiTi is related to type of antiseptic mouth rinse and coating formulations. Exposure to an artificial saliva and antiseptics tend to reduce flexibility and resilience of NiTi archwires. The influence of the media is more significant than the influence of the type of the alloys coating. The largest release of nickel ions is in the first 3 days. Antiseptics do not cause further deterioration of the elastic properties in uncoated NiTi compared to saliva. As a result of exposure of nitrified NiTi wires in Listerine, there is bigger release of nickel ions, decrease in elastic properties and lower force delivery in unload. Listerine tends to reduce elastic properties of rhodium-coated wires also. In conclusion, except for Listerine, changes of mechanical characteristics induced by antiseptics are small and would not have a clinically important impact. Generally, Curasept would be the most suitable option.


Assuntos
Anti-Infecciosos Locais , Níquel , Ligas , Ligas Dentárias , Teste de Materiais , Fios Ortodônticos , Propriedades de Superfície , Titânio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA