Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Australas J Ultrasound Med ; 23(3): 159-166, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32837568

RESUMO

This is an opinion piece on the role of POCUS in COVID-19, with a focus on lung ultrasound. It is not an instructional essay. Crisis management in medicine has often been likened to crisis management in the aviation industry. The important difference between pilots and clinicians is that the clinician's life was not in imminent danger, should one fail. The clinician did not have the same emotional urgency as the pilot. The COVID-19 pandemic has changed this, and clinicians are now faced with the need to make urgent decisions whilst exposed to some personal risk. Whether to embrace POCUS and lung ultrasound during this pandemic is an important decision. Whilst there are clear advantages, poorly considered overzealous uptake is not without hazard, opportunity cost and potential risk to patient and clinician.

2.
Emerg Med Australas ; 32(6): 967-973, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32383347

RESUMO

OBJECTIVE: This pilot study assessed the efficacy of personalised, printed and mobile-accessible discharge instructions for pain relief for patients discharged from the ED. METHODS: Patients presenting with pain caused by acute musculoskeletal or visceral complaints not requiring admission were eligible. Both groups received usual pain relief discharge advice, the intervention group received additional personalised printed and mobile-accessible discharge instructions. Numerical Rating Scale pain scores were measured at ED visit. Pain scores, Patient Global Impression of Change scale improvement scores, satisfaction with instructions, recall of pain relief advice, receipt of side effects advice and unscheduled visits were measured at 5 days. RESULTS: A total of 80 patients, recruited over 14 days, were randomly allocated to the intervention or control group. Two patients were excluded and 81% (n = 65) were followed up at 5 days. There was no significant difference in change of pain scores or improvement scores between groups from visit to 5 day follow up. The intervention group showed significantly higher odds of being 'very satisfied' compared to the control group (odds ratio [OR] 7.14, 95% confidence interval [CI] 1.18-50.00), significantly higher odds of full recall of pain relief medication advice (OR 20.00, 95% CI 1.56-100.00) and significantly higher odds of receiving information on medication side effects (OR 6.25, 95% CI 1.67-20.00). CONCLUSIONS: Patients who received personalised printed and mobile-accessible ED discharge instructions for pain relief reported higher levels of satisfaction with their instructions, had better recall of their pain relief medications advice and received more information on medication side-effects.


Assuntos
Serviço Hospitalar de Emergência , Alta do Paciente , Analgésicos/uso terapêutico , Humanos , Dor/tratamento farmacológico , Projetos Piloto
3.
Emerg Med Australas ; 32(5): 737-746, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32249549

RESUMO

OBJECTIVE: Point-of-care ultrasound (POCUS) is now ubiquitous in emergency medicine. Increased accessibility does not, however, ensure expertise in its use. We present a unique model of an Emergency Medicine Advanced Ultrasound Service (EMAUS). In our model specialist emergency physicians with advanced ultrasound (US) qualifications (emergency sonologists), provide images and reports for the entire department. The service is considered an extension of the traditional radiology model. It is consultative, diagnostic and procedural, and includes full US examinations as well as POCUS examinations. METHODS: A 4-month prospective descriptive observational study was conducted at a tertiary hospital during which data was recorded about emergency medicine US use and its outcomes. RESULTS: A total of 1336 US scans were recorded. Emergency sonologists conducted the majority of examinations, 69.8%. Half the consultative USs demonstrated positive findings. Follow-up computed tomography (CT) was recommended in 8.8% of consultative US studies and 12.4% of POCUS studies. Concerning incidental findings requiring further investigation (usually CT/magnetic resonance imaging) were infrequent at 1.6%. CONCLUSION: Globally POCUS has proliferated with varying expertise and data to support its use. The EMAUS provides a trusted and accountable service with the advantages of simultaneously integrating consultative US into the clinical context by an emergency physician. A diverse range of indications, scan types and pathology was recorded over the period demonstrating the utility of combining the roles of senior clinician, sonographer and radiologist and the benefits of advanced training and credentialing.


Assuntos
Medicina de Emergência , Sistemas Automatizados de Assistência Junto ao Leito , Serviço Hospitalar de Emergência , Humanos , Estudos Prospectivos , Ultrassonografia
4.
BMJ Open ; 9(4): e022278, 2019 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-30944127

RESUMO

OBJECTIVES: This study aimed to identify the incidence of and factors associated with peripheral intravenous catheter/cannula (PIVC) first time insertion success (FTIS) in the emergency department (ED). DESIGN: Prospective cohort study. SETTING: Two tertiary EDs in Western Australia. PARTICIPANTS: 879 ED patients. PRIMARY OUTCOME: To identify factors affecting FTIS using univariate and multivariate logistic regression modelling. We created four models: patient factors only; clinician factors only; products and technology factors only and all factors model. We assessed each model's performance using area under the receiver operating characteristic curve. RESULTS: A total of 1201 PIVCs were inserted in 879 patients. The mean age was 60.3 (SD 22) years with slightly more females (52%). The FTIS rate was 73%, with 128 (15%) requiring a second attempt and 83 (9%) requiring three or more attempts. A small percentage (3%) had no recorded number of subsequent attempts. FTIS was related to the following patient factors: age (for a 1-year increase in age: OR 0.99, 95% CI 0.983 to 0.998; p=0.0097); and target vein palpability: (always palpable vs never palpable: OR 3.53 95% CI 1.64 to 7.60; only palpable with tourniquet vs never palpable: OR 2.20, 95% CI 1.06 to 4.57; p=0.0014). Clinician factors related to FTIS include: clinicians with greater confidence (p<0.0001) and insertion experience (301-1000 vs <301: OR 1.54, 95% CI 1.02 to 2.34; >1000 vs <301: OR 2.07, 95% CI 1.41 to 3.04; p=0.0011). The final all factors model combining patient factors; clinician factors and product and technology factors has greater discriminative ability than specific factors models. It has a sensitivity of 74.26%, specificity of 57.69%, positive predictive value of 82.87% and negative predictive value of 44.85%. CONCLUSION: A clinical decision, matching patients who have no palpable veins and are older, with clinicians with greater confidence and experience, will likely improve FTIS. TRIALREGISTRATION NUMBER: ANZCTRN12615000588594; Results.


Assuntos
Cateterismo Periférico/instrumentação , Cateteres de Demora , Cateteres Venosos Centrais , Serviço Hospitalar de Emergência , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo Periférico/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Risco , Sensibilidade e Especificidade , Falha de Tratamento , Austrália Ocidental
5.
PLoS One ; 14(3): e0213923, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30901370

RESUMO

BACKGROUND: It is well established that the idle peripheral intravenous catheter (PIVC) provides no therapeutic value and is a clinical, economic and above all, patient concern. This study aimed to develop a decision aid to assist with clinical decision making to promote clinically indicated peripheral intravenous catheter (CIPIVC) insertion in the emergency department (ED) setting. Providing evidence for a uniform process could assist clinicians in a decision-making process for PIVC insertion. This could enable patients receive appropriate vascular access healthcare. METHODS: We performed a secondary analysis of data from a multicentre cohort of emergency department clinicians who performed PIVC insertion. We defined CIPIVC a priori as one used for a specific clinical treatment and or procedure such as prescribed intravenous (IV) fluids; prescribed IV medication; or IV contrast (for computerized tomography scans). We sought to refute or validate an assumption if the clinician performing or requesting the insertion decided the patient was >80% likely to need a PIVC. Using logistic regression, we derived a decision aid for CIPIVCs. RESULTS: In 817 patients undergoing PIVC insertion, we observed 68% of these to be CIPIVCs. Admitted patients were significantly more likely to have a CIPIVC, Odds Ratio (OR) = 3.05, 95% confidence interval (CI) = 2.17-4.30, p = <0.0001. Before insertion, patients who definitely needed IV fluids/medicines OR = 3.30, 95% CI = 2.02-5.39, p = <0.0001 and who definitely needed a contrast scan OR = 3.04, 95% CI = 1.15-8.03, p = 0.0250 were significantly more likely to have a device inserted for a clinical indication. Patients who presented with an existing vascular access device were more likely to have a new CIPIVC inserted for use OR = 4.35, 95% CI = 1.58-11.95, p = 0.0043. The clinician's pre-procedural judgment of the likelihood of therapeutic use >80% was independently associated with CIPIVC; OR 3.16, 95% CI = 2.06-4.87, p<0.0001. The area under the receiver operating characteristic curve was 0.81, and at the best cut-off, the model had a specificity of 0.81, sensitivity of 0.71, a positive predictive value of 0.89 and negative predictive value of 0.57. CONCLUSIONS: Using the derived decision aid, clinicians could ask:- "Does this patient need A-PIVC?" Clinicians can decide to insert a CIPIVCs when: (i) Admission to hospital is anticipated and when (ii) a Procedure requires a PIVC, e.g., computerised tomography scans and where an existing suitable vascular access device is not present and or; (iii) there is an indication for IV fluids and or medicines that cannot be tolerated enterally and are suitable for dilution in peripheral veins; and, (iv) the Clinician's perceived likelihood of use is greater than 80%.


Assuntos
Cateterismo Periférico/métodos , Tomada de Decisão Clínica/métodos , Estudos de Coortes , Técnicas de Apoio para a Decisão , Remoção de Dispositivo/métodos , Serviço Hospitalar de Emergência , Feminino , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Preservação Biológica/métodos , Dispositivos de Acesso Vascular
6.
J Clin Nurs ; 28(11-12): 2135-2146, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30667115

RESUMO

AIMS AND OBJECTIVES: To evaluate the accuracy of traditional clinical predialytic fluid assessment by renal nurses and the efficacy of 2 additional fluid assessment methods focussing on the potential preventative effect for intradialytic hypotension (IDH). BACKGROUND: Predialytic fluid assessment remains a daily challenge for renal nurses, when aiming for adverse event free haemodialysis treatments. Adding further objective parameters obtained through noninvasive methods into pre- and intradialytic fluid assessment could potentially improve health outcomes for haemodialysis patients. DESIGN: Comparative, observational study of three fluid assessment methods on their reliability on volume status and correlation to clinical outcomes. METHODS: Clinical predialytic nursing fluid assessments in 30 haemodialysis patients were compared with additional initial bioimpedance spectroscopy (BIS) measurements, and 3 serial intradialytic ultrasound scans of the inferior vena cava (IVC-US) performed by a second renal nurse concurrently during the same session. A retrospective data analysis compared all measurements in each individual for the predictive value for IDH. A STROBE checklist for observational cohort studies was used for the reporting of results. RESULTS: Seven subjects experienced episodes of symptomatic intradialytic hypotension (S-IDH), which would have been anticipated by IVC-US or by BIS in 5 patients (71%). Using an algorithm to predict IDH would have provided a sensitivity of 100% and specificity of 95%. CONCLUSION: Both additional fluid assessment methods would have provided critical information before and during each haemodialysis session. Therefore, we consider them as being potentially effective for the prevention of intradialytic hypotension, with IVC-US being similar to BIS. RELEVANCE TO CLINICAL PRACTICE: Traditional clinical nursing fluid assessment methods in haemodialysis patients do not provide sufficient information to prevent episodes of IDH. Additional objective fluid assessment methods are useful and likely to lead to improved health outcomes in HD patients when applied by renal nurses. A combination of IVC-US, MAP and BIS has potential to reduce the risk of IDH events in HD patients significantly.


Assuntos
Hipotensão/etiologia , Diálise Renal/efeitos adversos , Diálise Renal/enfermagem , Veia Cava Inferior/diagnóstico por imagem , Adulto , Idoso , Algoritmos , Estudos de Coortes , Feminino , Humanos , Hipotensão/enfermagem , Masculino , Pessoa de Meia-Idade , Enfermagem em Nefrologia/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Análise Espectral , Ultrassonografia
7.
Infect Control Hosp Epidemiol ; 39(10): 1216-1221, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30196798

RESUMO

BACKGROUND: Most patients admitted to the hospital via the emergency department (ED) do so with a peripheral intravenous catheter/cannula (PIVC). Many PIVCs develop postinsertion failure (PIF). OBJECTIVE: To determine the independent factors predicting PIF after PIVC insertion in the ED. METHODS: We analyzed data from a prospective clinical cohort study of ED-inserted PIVCs admitted to the hospital wards. Independent predictors of PIF were identified using Cox proportional hazards regression modeling. RESULTS: In 391 patients admitted from 2 EDs, the rate of PIF was 31% (n=118). The types of PIF identified were infiltration, occlusion, pain and/or peripheral intravenous assessment score >2 (ie, the hospital's assessment of PIVC phlebitis), and dislodgement (ie, accidental securement device failure or purposeful removal). Of the PIVCs that failed, infiltration and occlusion combined were the most common causes of PIF (n=55, 47%). The median PIVC dwell time was 28.5 hours (interquartile range [IQR], 17.4-50.8 hours). The following variables were associated with increased risk of PIF: being an older patient (for a 1-year increase, hazard ratio [HR], 1.02; 95% confidence interval [CI], 1.01-1.03; P=.0001); having an Australian Triage Scale score of 1 or 2 compared to a score of 3, 4, or 5 (HR, 2.04; 95% CI, 1.39-3.01; P=.0003); having an ultrasound-guided PIVC (HR, 6.52; 95% CI, 2.11-20.1; P=.0011); having the PIVC inserted by a medical student (P=.0095); infection prevention breaches at insertion (P=.0326); and PIVC inserted in the ante cubital fossa or the back of hand compared to the upper arm (P=.0337). CONCLUSION: PIF remains at an unacceptable level in both traditionally inserted and ultrasound-inserted PIVCs.Clinical trial registrationAustralian and New Zealand Trials Registry (ANZCTRN12615000588594).


Assuntos
Cateterismo Periférico/instrumentação , Cateteres de Demora/efeitos adversos , Análise de Falha de Equipamento , Adulto , Idoso , Idoso de 80 Anos ou mais , Austrália , Cateterismo Periférico/métodos , Remoção de Dispositivo , Serviço Hospitalar de Emergência , Feminino , Antebraço , Mãos , Humanos , Masculino , Pessoa de Meia-Idade , Flebite/etiologia , Modelos de Riscos Proporcionais , Estudos Prospectivos
8.
J Clin Nurs ; 27(7-8): e1561-e1570, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29446172

RESUMO

AIMS AND OBJECTIVES: To measure the prevalence of symptomatic (S-IDH) and asymptomatic intradialytic hypotension (A-IDH) or postdialysis overhydration in a satellite haemodialysis clinic in Western Australia. BACKGROUND: Intradialytic hypotension is one of the most common side effects of haemodialysis caused by ultrafiltration provoking a temporary volume depletion. The prevalence of asymptomatic hypotension during dialysis has been rarely reported, but is considered to have the same negative consequences as symptomatic hypotension on various end organs like the brain and the gastrointestinal tract. DESIGN: Observational study on a retrospective 3-month period of nursing recorded fluid-related adverse events. METHODS: Data collection on the occurrence of S-IDH and A-IDH during a total of 2,357 haemodialysis treatments in 64 patients. Body weight of patients at the time of cessation of treatment was recorded, and patients, whose weight exceeded their ideal body weight by at least 0.5 kg, were classified as overhydrated. Data analysis was performed using spss version 24 software. RESULTS: Symptomatic intradialytic hypotension was the most common adverse event measured in this cohort, and occurred during 221 (9.4%) of all treatments, whereas asymptomatic intradialytic hypotension occurred in 88 (3.7%) of all treatments. The total occurrence of intradialytic hypotension was 13.1%, and symptomatic was observed in 30 patients, implying that nearly every second patient had at least one symptomatic episode within 3 months. Overhydration occurred in a total of 103 (4.4%) of all treatments, and involved 17 patients. CONCLUSIONS: Symptomatic and asymptomatic intradialytic hypotension were the most commonly observed adverse events in this cohort; overhydration occurrence was considerably less common. RELEVANCE TO CLINICAL PRACTICE: The high occurrence of hypotension-related events demonstrates that ultrafiltration treatment goals in satellite dialysis clinics are sometimes overestimated, resulting in regular significant symptomatic episodes for the patient. Raising the awareness of the prevalence of IDH amongst renal nurses could be an essential initial step before collectively preventative strategies in haemodialysis satellite units are implemented.


Assuntos
Instituições de Assistência Ambulatorial/estatística & dados numéricos , Hipotensão/epidemiologia , Hipotensão/etiologia , Falência Renal Crônica/terapia , Diálise Renal/efeitos adversos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Austrália Ocidental/epidemiologia
9.
Hemodial Int ; 22(2): 261-269, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29024379

RESUMO

INTRODUCTION: Ultrasound of the inferior vena cava (IVC-US) has been used to estimate intravascular volume status and fluid removal during a hemodialysis session. Usually, renal nurses rely on other, imprecise methods to determine ultrafiltration. To date, no study has examined whether renal nurses can reliably perform ultrasound for volume assessment and for potential prevention of intradialytic hypotension. This pilot study aimed to determine if a renal nurse could master the skill of performing and correctly interpreting Point of Care Ultrasound on patients receiving hemodialysis. METHODS: After receiving theoretical training and performing 100 training scans, a renal nurse performed 60 ultrasound scans on 10 patients. These were categorized by the nurse into hypovolemic, euvolemic, or hypervolemic through measurement of the maximal diameter and degree of collapse of the IVC. Scans were subsequently assessed for adequacy and quality by two sonologists, who were blinded to each other's and the nurse's results. FINDINGS: The interrater reliability of 60 scans was good, with intraclass correlation 0.79 (95% confidence interval (CI) =0.63-0.87) and with a good interrater agreement for the following estimation of intravascular volume (Cohen's weighted Kappa κw = 0.62), when comparing the nurse to an expert sonographer. DISCUSSION: A renal nurse can reliably perform ultrasound of the IVC in hemodialysis patients, obtaining high quality scans for volume assessment of hemodialysis patients. This novel approach could be more routinely applied by other renal nurses to obtain objective measures of patient volume status in the dialysis setting.


Assuntos
Diálise Renal/métodos , Ultrassonografia/métodos , Veia Cava Inferior/diagnóstico por imagem , Idoso , Estudos Transversais , Feminino , Humanos , Masculino , Enfermeiras e Enfermeiros
10.
J Hosp Med ; 12(10): 851-858, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28991954

RESUMO

BACKGROUND: First-time peripheral intravenous catheter (PIVC) insertion success is dependent on patient, clinician, and product factors. Failed PIVC insertion are an under-recognized clinical phenomenon. OBJECTIVE: To provide a scoping review of decision aids for PIVC insertion including tools, clinical prediction rules, and algorithms (TRAs) and their findings on factors associated with insertion success. METHODS: In June 2016, a systematic literature search was performed using the medical subject heading of peripheral catheterization and tool* or rule* or algorithm*. Data extraction included clinician, patient, and/or product variables associated with PIVC insertion success. Information about TRA reliability, validity, responsiveness, and utility was also extracted. RESULTS: We screened 36 studies, and included 13 for review. Seven papers reported insertion success ranging from 61%-90% (4030 insertion attempts), 6 on validity, and 5 on reliability, with none reporting on responsiveness and utility. Failed insertions were associated with obesity (odds ratio [OR], 0.71-1.7; 2 studies) and smaller gauge PIVCs (OR, 6.4; 95% Confidence Interval [CI}, 3.4-11.9). Successful inser tions were associated with visible veins (OR, 0.87-3.63; 3 studies) or palpable veins (OR, 0.79-5.05; 3 studies) and inserters with greater procedural volume (OR, 4.4; 95% CI, 1.6-12.1) or who predicted that insertion would be successful (OR, 1.06; 95% CI, 1.04-1.07). Definitions of insertion difficulty are heterogeneous such as time to insert to a number of failed attempts. CONCLUSIONS: Few well-validated reliable TRAs exist for PIVC insertion. Patients would benefit from a validated, clinically pragmatic TRA that matches insertion difficulty with clinician competency.


Assuntos
Algoritmos , Cateterismo Periférico/métodos , Competência Clínica , Técnicas de Apoio para a Decisão , Hospitalização , Humanos
11.
J Vasc Access ; 18(3): 255-258, 2017 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-28430318

RESUMO

INTRODUCTION: Ultrasound is recommended to guide insertion of peripheral intravenous vascular cannulae (PIVC) where difficulty is experienced. Ultrasound machines are now common-place and junior doctors are often expected to be able to use them. The educational standards for this skill are highly varied, ranging from no education, to self-guided internet-based education, to formal, face-to-face traditional education. In an attempt to decide which educational technique our institution should introduce, a small pilot trial comparing educational techniques was designed. METHODS: Thirty medical students were enrolled and allocated to one of three groups. PIVC placing ability was then observed, tested and graded on vascular access phantoms. RESULTS: The formal, face-to-face traditional education was rated best by the students, and had the highest success rate in PIVC placement, the improvement statistically significant compared to no education (p = 0.01) and trending towards significance when compared to self-directed internet-based education (p<0.06). CONCLUSIONS: The group receiving traditional face-to-face teaching on ultrasound-guided vascular access, performed significantly better than those not receiving education. As the number of ultrasound machines in clinical areas increases, it is important that education programs to support their safe and appropriate use are developed.


Assuntos
Cateterismo Periférico/métodos , Instrução por Computador , Educação de Graduação em Medicina/métodos , Autoaprendizagem como Assunto , Estudantes de Medicina , Ultrassonografia de Intervenção/métodos , Competência Clínica , Currículo , Humanos , Imagens de Fantasmas , Projetos Piloto , Análise e Desempenho de Tarefas , Ultrassonografia de Intervenção/instrumentação
12.
J Ren Care ; 43(3): 132-142, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28120381

RESUMO

BACKGROUND: In Western Australia (WA), most stable patients undergoing haemodialysis receive treatment in a satellite setting where no doctors are on-site during treatment hours, so nurses must make critical decisions about fluid removal. Some patients regularly experience adverse events during dialysis (intradialytic), often due to excessive ultrafiltration goals, with intradialytic hypotension being particularly challenging. Ultrasound of the inferior vena cava has been previously demonstrated being a rapid and non-invasive method for volume assessment on haemodialysis patients, thus could hold valuable information for the treating nurse. AIM: This paper examines the existing literature in regards to the use of ultrasound measurements of the inferior vena cava in patients on haemodialysis for objective assessment of their intravascular volume status by renal nurses. METHOD: A systematic literature review was performed within medical and nursing databases including CINAHL Plus with Full Text, SCOPUS, Web of Science and MEDLINE. RESULTS: Renal nurses are conscious of the significance of intradialytic hypotension and have only limited options for its prevention. Ultrasound of the inferior vena cava could add another objective dimension for intravascular volume assessment and prevention of intradialytic hypotension, but to date renal nurses have not been using this technique. CONCLUSIONS: Ultrasound of the inferior vena cava has the potential to assist in defining the ultrafiltration goal for that particular dialysis session, thus reducing the risk of intradialytic hypotension. Additionally, it has potential to change current renal nursing practice when added to clinical nursing assessment methods. Further studies are required to validate this assessment tool carried out by a renal nurse compared with a skilled ultrasonographer.


Assuntos
Papel do Profissional de Enfermagem , Enfermeiras e Enfermeiros/normas , Ultrassonografia/enfermagem , Humanos , Padrões de Prática em Enfermagem/tendências , Diálise Renal/enfermagem , Austrália Ocidental
13.
J Emerg Med ; 52(2): 208-215, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27814988

RESUMO

BACKGROUND: Painful forearm injuries after a fall occur frequently in children. X-ray study is currently the gold standard investigation. Ultrasound (US) is a potential alternative that avoids exposure to ionizing radiation and may be less painful than x-ray study; and familiarity and skill with US is increasing among emergency physicians. OBJECTIVES: The primary aim of this study was to determine if a cohort of physicians with little or no previous experience with US could, after a short training program, safely exclude forearm fractures in children. Secondary aims were to compare any pain or discomfort associated with clinical examination, US, and x-ray study and to determine the acceptability of US as a diagnostic tool to parents and patients. METHODS: A prospective, nonrandomized, interventional diagnostic study was performed on children between the ages of 0 and 16 years who had a suspected fracture of the forearm. US scanning was performed by a group of physicians, most with little or no previous US experience. RESULTS: After the brief training program, a group of pediatric emergency physicians could diagnose forearm fractures in children with a sensitivity of 91.5% and a specificity of 87.6%. Pain associated with US was no better or worse than pain associated with x-ray study. Patients and parents preferred US over x-ray study as an investigation modality for suspected forearm fractures. CONCLUSION: A group of pediatric emergency physicians with limited previous experience could, after a short training program, diagnose forearm fractures in children. Pain associated with US was no better or worse than pain associated with x-ray study.


Assuntos
Fraturas Ósseas/diagnóstico , Ultrassonografia/normas , Raios X , Acidentes por Quedas , Adolescente , Austrália , Criança , Pré-Escolar , Feminino , Antebraço/fisiologia , Traumatismos do Antebraço/diagnóstico , Humanos , Lactente , Masculino , Manejo da Dor/métodos , Sistemas Automatizados de Assistência Junto ao Leito/normas , Sistemas Automatizados de Assistência Junto ao Leito/tendências , Estudos Prospectivos
14.
Emerg Med Australas ; 28(6): 658-665, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27862989

RESUMO

OBJECTIVE: Failed attempts at peripheral i.v. cannula (PIVC) insertion in the ED are common. The psychological, physical and economic impact of these failures is significant. We sought to explore whether clinicians of differing experience levels can predict their own likelihood (clinician 'gestalt') of first-time cannula insertion success on any given patient. METHODS: Data analyses from a prospective self-reported study assessing risk factors for first-time insertion success in a tertiary adult ED. We constructed and compared two simple theoretical clinical decision algorithms in an attempt to improve first-time PIVC insertion success rates. RESULTS: This best algorithm identified a subgroup of 18% of the total PIVC population at higher risk of failure. This 18% comprised 57% of all PIVC failures, and implementation would result in a relative risk reduction of PIVC failure by 31%. CONCLUSIONS: When applied to our sample population, an algorithm relying on clinician gestalt to identify patients at high risk of PIVC failure had the greatest potential impact. These patients would be referred to expert PIVC inserters prior to, rather than after, failed attempts.


Assuntos
Cateterismo Periférico , Competência Clínica/estatística & dados numéricos , Serviço Hospitalar de Emergência , Adulto , Idoso , Algoritmos , Cânula , Feminino , Teoria Gestáltica , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Austrália Ocidental
16.
BMJ Open ; 6(2): e009196, 2016 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-26868942

RESUMO

INTRODUCTION: Peripheral intravenous cannula (PIVC) insertion is one of the most common clinical interventions performed in emergency care worldwide. However, factors associated with successful PIVC placement and maintenance are not well understood. This study seeks to determine the predictors of first time PIVC insertion success in emergency department (ED) and identify the rationale for removal of the ED inserted PIVC in patients admitted to the hospital ward. Reducing failed insertion attempts and improving peripheral intravenous cannulation practice could lead to better staff and patient experiences, as well as improving hospital efficiency. METHODS AND ANALYSIS: We propose an observational cohort study of PIVC insertions in a patient population presenting to ED, with follow-up observation of the PIVC in subsequent admissions to the hospital ward. We will collect specific PIVC observational data such as; clinician factors, patient factors, device information and clinical practice variables. Trained researchers will gather ED PIVC insertion data to identify predictors of insertion success. In those admitted from the ED, we will determine the dwell time of the ED-inserted PIVC. Multivariate regression analyses will be used to identify factors associated with insertions success and PIVC failure and standard statistical validation techniques will be used to create and assess the effectiveness of a clinical predication rule. ETHICS AND DISSEMINATION: The findings of our study will provide new evidence to improve insertion success rates in the ED setting and identify strategies to reduce premature device failure for patients admitted to hospital wards. Results will unravel a complexity of factors that contribute to unsuccessful PIVC attempts such as patient and clinician factors along with the products, technologies and infusates used. TRIAL REGISTRATION NUMBER: ACTRN12615000588594; Pre-results.


Assuntos
Cateterismo Periférico , Técnicas de Apoio para a Decisão , Serviço Hospitalar de Emergência , Estudos de Coortes , Humanos , Estudos Prospectivos , Fatores de Risco , Falha de Tratamento
17.
J Vasc Access ; 17(2): 182-90, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26660037

RESUMO

BACKGROUND: We sought to identify the reasons for peripheral intravenous cannulae insertion in the emergency department (ED), and the first-time insertion success rate, along with patient and clinician factors influencing this phenomenon. METHODS: A prospective cohort study of patients requiring peripheral cannulae insertion in a tertiary ED. Clinical and clinician data were obtained. RESULTS: A total 734 peripheral intravenous cannula (PIVC) insertions were included in the study where 460 insertions were analysed. The first-time insertion success incidence was 86%. The antecubital fossa (ACF) site accounted for over 50% of insertions. Multivariate logistic regression modelling to predict first-time insertion success for patient factors found: age <40 versus 80+ years, emaciated versus normal patient size, having a visible or palpable vein/s, and ACF versus forearm insertion site to be statistically significant. Statistically significant clinician factors predicting success were: higher number of prior cannulation procedures performed, and increased clinician perception of the likelihood of a successful insertion. When patient and clinician factors were combined in a logistic regression model, emaciated versus normal, visible vein/s, ACF versus forearm site, higher number of prior PIVC procedures performed and increased clinician perceived likelihood of success were statistically associated with first-time insertion success. CONCLUSIONS: Peripheral intravenous cannulation insertion success could be improved if performed by clinicians with greater procedural experience and increased perception of the likelihood of success. Some patient factors predict cannulation success: 'normal' body weight, visible vein/s and cubital fossa placement; venepuncture may be a cheaper alternative for others if intravenous therapy is not imperative.


Assuntos
Cateterismo Periférico/instrumentação , Cateteres de Demora , Cateteres Venosos Centrais , Serviço Hospitalar de Emergência , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo Periférico/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Estudos Prospectivos , Fatores de Risco , Falha de Tratamento
18.
J Vasc Access ; 16(5): 422-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26349885

RESUMO

PURPOSE: This paper describes a simple and inexpensive method to make high-fidelity simulators for use in ultrasound-guided vascular access teaching. The phantoms can be created to reflect the ultrasound appearance and feel of central or peripheral arteries and veins. Different clinical states such as hypovolaemia may be readily displayed using the phantoms. METHODS: The article and associated videos describe the production, appearance and use of phantoms for central vascular access, for peripheral venous access and for peripheral arterial access. Key ingredients are readily accessible and include chicken breasts, modelling balloons and thin walled latex or silicone tubing. RESULTS: The phantoms are easily and rapidly constructed and may be used repeatedly in a training session. As the needle passes through the phantom and vessel wall, the ultrasound appearance and tactile sensation is very similar to that of human tissue and vessels. CONCLUSIONS: Using this method, simple and inexpensive phantoms can be created. These are ideal for use in training for ultrasound-guided vascular access. Links to videos describing the phantom construction process, their appearance and the teaching techniques utilised by the authors are found in the text.


Assuntos
Cardiologia/educação , Cateterismo/instrumentação , Educação Médica/métodos , Modelos Anatômicos , Modelos Cardiovasculares , Imagens de Fantasmas , Ultrassonografia de Intervenção/instrumentação , Animais , Galinhas , Competência Clínica , Desenho de Equipamento , Humanos , Látex , Destreza Motora , Músculo Esquelético , Punções , Silicones , Análise e Desempenho de Tarefas , Tato
19.
Clin Case Rep ; 3(3): 170-4, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25838907

RESUMO

We report a case of peripherally inserted central venous catheter (PICC)-associated deep vein thrombosis (DVT). Ultrasound images and video of subclavian thrombus are presented. PICC line-associated DVT, particularly in cancer patients is not uncommon. Point-of-care Emergency Department ultrasound can readily diagnose this complication and device removal is not always necessary.

20.
Australas J Ultrasound Med ; 18(1): 10-18, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28191236

RESUMO

Introduction: In the setting of patients presenting with shortness of breath to an Emergency Department a simple lung ultrasound protocol aimed at detecting pulmonary oedema has been shown to have diagnostic accuracy of 85%. This article reviews data from the original study, in an attempt to determine whether adjusting the protocol and/or interpretive criteria would improve results. Method: A large lung ultrasound project provided the dataset. Inter-rater and intertest discrepancies were reviewed. Then original stored images and comments were retrospectively analysed using alternate interpretive criteria. Specific variations included changing the number of B-lines required to define 'wet lung' and assessing other pleural line abnormalities. Where they had been acquired cardiac loops were reviewed in addition to the lung images. Results: The 204 original studies available were reviewed. Some disagreement could be attributed to inexperience and unclear definitions. Adjusting the number of B-lines did not improve diagnostic accuracy. All positive scans, with numerous B-lines were reviewed using more advanced diagnostic criteria (pleural line abnormalities) and the number of false positives was decreased. In cases where cardiac views were available, their inclusion was beneficial. Conclusion: A simple lung ultrasound protocol to assess for 'wet lung' in patients presenting to Emergency Departments provides diagnostic accuracy of around 85% in the hands of relative novices. More advanced interpretation of the same_ultrasound images, and the addition of cardiac views, is likely to further improve diagnostic accuracy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA