Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Nanomaterials (Basel) ; 13(18)2023 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-37764577

RESUMO

Chemoresistive nanostructured gas sensors are employed in many diverse applications in the medical, industrial, environmental, etc. fields; therefore, it is crucial to have a device that is able to quickly calibrate and characterize them. To this aim, a portable, user-friendly device designed to easily calibrate a sensor in laboratory and/or on field is introduced here. The device comprises a small hermetically sealed chamber (containing the sensor socket and a temperature/humidity sensor), a pneumatic system, and a custom electronics controlled by a Raspberry Pi 4 developing board, running a custom software (Version 1.0) whose user interface is accessed via a multitouch-screen. This device automatically characterizes the sensor heater in order to precisely set the desired working temperature, it acquires and plots the sensor current-to-voltage and Arrhenius relationships on the touch screen, and it can record the sensor responses to different gases and environments. These tests were performed in dry air on two representative sensors based on widely used SnO2 material. The device demonstrated the independence of the Arrhenius plot from the film applied voltage and the linearity of the I-Vs, which resulted from the voltage step length (1-30 min) and temperature (200-550 °C).

2.
Cancers (Basel) ; 15(6)2023 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-36980683

RESUMO

Colorectal cancer (CRC) represents 10% of the annual tumor diagnosis and deaths occurring worldwide. Given the lack of specific symptoms, which could determine a late diagnosis, the research for specific CRC biomarkers and for innovative low-invasive methods to detect them is crucial. Therefore, on the basis of previously published results, some volatile organic compounds (VOCs), detectable through gas sensors, resulted in particularly promising CRC biomarkers, making these sensors suitable candidates to be employed in CRC screening devices. A new device was employed here to analyze the exhalations of blood samples collected from CRC-affected patients at different stages of their pre- and post-surgery therapeutic path, in order to assess the sensor's capability for discriminating among these samples. The stages considered were: the same day of the surgical treatment (T1); before the hospital discharge (T2); after one month and after 10-12 months from surgery (T3 and T4, respectively). This device, equipped with four different sensors based on different metal-oxide mixtures, enabled a distinction between T1 and T4 with a sensitivity and specificity of 93% and 82%, respectively, making it suitable for clinical follow-up protocols, patient health status monitoring and to detect possible post-treatment relapses.

3.
Sensors (Basel) ; 23(4)2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36850578

RESUMO

Nowadays, most medical-diagnostic, environmental monitoring, etc. devices employ sensors whose fabrication reproducibility and response repeatability assessment are crucial. The former consists of large-scale sensor manufacture through a standardized process with almost identical morphology and behavior, while the latter consists of giving the same response upon repeating the same stimulus. The thermo-activated chemoresistive sensors, which change their conductance by interacting with the molecules composing the surrounding gas, are currently employed in many devices: in particular, thick-film (SnTiNb)O2 nanosensors were demonstrated to be particularly suitable in the medical and biological fields. Therefore, a set of thirteen of them, randomly selected from the same screen-printing deposition, were laboratory tested, and the outcomes were statistically analyzed in order to assess their consistency. At first, the working temperature that maximized both the sensor sensitivity and response repeatability was identified. Then, the sensors were subjected to different gas concentrations and humidities at this optimal working temperature. It resulted in the (SnTiNb)O2 nanosensors detecting and discriminating CO concentrations as low as 1 ppm and at high humidity degrees (up to 40%) with high repeatability since the response relative standard error ranged from 0.8 to 3.3% for CO and from 3.6 to 5.4% for water vapor.

4.
Arch Biochem Biophys ; 737: 109534, 2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36740034

RESUMO

Exposure of human lung epithelial cells (A549 cell line) to the oxidant pollutant ozone (O3) alters cell membrane currents inducing its decrease, when the cell undergoes to a voltage-clamp protocol ranging from -90 to +70mV. The membrane potential of these cells is mainly maintained by the interplay of potassium and chloride currents. Our previous studies indicated the ability of O3 to activate ORCC (Outward Rectifier Chloride Channel) and consequently increases the chloride current. In this paper our aim was to understand the response of potassium current to oxidative stress challenge and to identify the kind potassium channel involved in O3 induced current changes. After measuring the total membrane current using an intracellular solution with or without potassium ions, we obtained the contribution of potassium to the overall membrane current in control condition by a mathematical approach. Repeating these experiments after O3 treatment we observed a significant decrease of Ipotassium. Treatment of the cells with Iberiotoxin (IbTx), a specific inhibitor of BK channel, we were able to verify the presence and the functionality of BK channels. In addition, the administration of 4-Aminopyridine (an inhibitor of voltage dependent K channels but not BK channels) and Tetraethylammonium (TEA) before and after O3 treatment we observed the formation of BK oxidative post-translation modifications. Our data suggest that O3 is able to inhibit potassium current by targeting BK channel. Further studies are needed to better clarify the role of this BK channel and its interplay with the other membrane channels under oxidative stress conditions. These findings can contribute to identify the biomolecular pathway induced by O3 allowing a possible pharmacological intervention against oxidative stress damage in lung tissue.


Assuntos
Bloqueadores dos Canais de Potássio , Potássio , Humanos , Bloqueadores dos Canais de Potássio/farmacologia , Potássio/metabolismo , Cloretos/metabolismo , Canais de Potássio Ativados por Cálcio de Condutância Alta/metabolismo , Pulmão/metabolismo , Estresse Oxidativo
5.
Nanomaterials (Basel) ; 12(7)2022 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-35407231

RESUMO

The detection of volatile organic compounds (VOCs) exhaled by human body fluids is a recent and promising method to reveal tumor formations. In this feasibility study, a patented device, based on nanostructured chemoresistive gas sensors, was employed to explore the gaseous exhalations of tumoral, immortalized, and healthy cell lines, with the aim of distinguishing their VOC patterns. The analysis of the device output to the cell VOCs, emanated at different incubation times and initial plating concentrations, was performed to evaluate the device suitability to identify the cell types and to monitor their growth. The sensors ST25 (based on tin and titanium oxides), STN (based on tin, titanium, and niobium oxides), and TiTaV (based on titanium, tantalum and vanadium oxides) used here, gave progressively increasing responses upon the cell density increase and incubation time; the sensor W11 (based on tungsten oxide) gave instead unreliable responses to all cell lines. All sensors (except for W11) gave large and consistent responses to RKO and HEK293 cells, while they were less responsive to CHO, A549, and CACO-2 ones. The encouraging results presented here, although preliminary, foresee the development of sensor arrays capable of identifying tumor presence and its type.

6.
Int J Mol Sci ; 23(7)2022 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-35409146

RESUMO

Some hearing, vestibular, and vision disorders are imputable to voltage-gated Ca2+ channels of the sensory cells. These channels convey a large Ca2+ influx despite extracellular Na+ being 70-fold more concentrated than Ca2+; such high selectivity is lost in low Ca2+, and Na+ can permeate. Since the permeation properties and molecular identity of sensory Ca2+ channels are debated, in this paper, we examine the Na+ current flowing through the L- and R-type Ca2+ channels of labyrinth hair cells. Ion currents and cytosolic free Ca2+ concentrations were simultaneously monitored in whole-cell recording synchronous to fast fluorescence imaging. L-type and R-type channels were present with different densities at selected sites. In 10 nM Ca2+, the activation and deactivation time constants of the L-type Na+ current were accelerated and its maximal amplitude increased by 6-fold compared to physiological Ca2+. The deactivation of the R-type Na+ current was not accelerated, and its current amplitude increased by 2.3-fold in low Ca2+; moreover, it was partially blocked by nifedipine in a voltage- and time-dependent manner. In conclusion, L channel gating is affected by the ion species permeating the channel, and its selectivity filter binds Ca2+ more strongly than that of R channel; furthermore, external Ca2+ prevents nifedipine from perturbing the R selectivity filter.


Assuntos
Cálcio , Nifedipino , Animais , Cálcio/metabolismo , Cátions , Cabelo/metabolismo , Nifedipino/farmacologia , Permeabilidade , Sódio/metabolismo , Vertebrados/metabolismo
8.
Molecules ; 26(2)2021 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-33477309

RESUMO

User-friendly, low-cost equipment for preventive screening of severe or deadly pathologies are one of the most sought devices by the National Health Services, as they allow early disease detection and treatment, often avoiding its degeneration. In recent years more and more research groups are developing devices aimed at these goals employing gas sensors. Here, nanostructured chemoresistive metal oxide (MOX) sensors were employed in a patented prototype aimed to detect volatile organic compounds (VOCs), exhaled by blood samples collected from patients affected by colorectal cancer and from healthy subjects as a control. Four sensors, carefully selected after many years of laboratory tests on biological samples (cultured cells, human stools, human biopsies, etc.), were based here on various percentages of tin, tungsten, titanium, niobium, tantalum and vanadium oxides. Sensor voltage responses were statistically analyzed also with the receiver operating characteristic (ROC) curves, that allowed the identification of the cut-off discriminating between healthy and tumor affected subjects for each sensor, leading to an estimate of sensitivity and specificity parameters. ROC analysis demonstrated that sensors employing tin and titanium oxides decorated with gold nanoparticles gave sensitivities up to 80% yet with a specificity of 70%.


Assuntos
Neoplasias Colorretais/sangue , Nanopartículas Metálicas/química , Microscopia Eletroquímica de Varredura , Nióbio/química , Tantálio/química , Estanho/química , Vanádio/química , Compostos Orgânicos Voláteis/sangue , Adulto , Feminino , Humanos , Masculino
9.
Pflugers Arch ; 473(1): 15-36, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33047171

RESUMO

To understand the working principles of the nervous system is key to figure out its electrical activity and how this activity spreads along the neuronal network. It is therefore crucial to develop advanced techniques aimed to record in real time the electrical activity, from compartments of single neurons to populations of neurons, to understand how higher functions emerge from coordinated activity. To record from single neurons, a technique will be presented to fabricate patch pipettes able to seal on any membrane with a single glass type and whose shanks can be widened as desired. This dramatically reduces access resistance during whole-cell recording allowing fast intracellular and, if required, extracellular perfusion. To simultaneously record from many neurons, biocompatible probes will be described employing multi-electrodes made with novel technologies, based on diamond substrates. These probes also allow to synchronously record exocytosis and neuronal excitability and to stimulate neurons. Finally, to achieve even higher spatial resolution, it will be shown how voltage imaging, employing fast voltage-sensitive dyes and two-photon microscopy, is able to sample voltage oscillations in the brain spatially resolved and voltage changes in dendrites of single neurons at millisecond and micrometre resolution in awake animals.


Assuntos
Corantes/química , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Neurônios/fisiologia , Neurotransmissores/metabolismo , Técnicas de Patch-Clamp/instrumentação , Animais , Humanos
10.
Nanomaterials (Basel) ; 10(4)2020 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-32224920

RESUMO

Despite the great progress in screening techniques and medical treatments, colorectal cancer remains one of the most widespread cancers in both sexes, with a high death rate. In this work, the volatile compounds released from human colon cancer tissues were detected by a set of four different chemoresistive sensors, made with a nanostructured powder of metal-oxide materials, inserted into an innovative patented device. The sensor responses to the exhalation of a primary cancer sample and of a healthy sample (both of the same weight, collected during colorectal surgery from the intestine of the same patient) were statistically analyzed. The sensors gave reversible, reproducible, and fast responses for at least one year of continuous use, making them quite superior in respect to the existing diagnostic methods. Preliminary results obtained using principal component analysis of the sensor responses to samples removed from 13 patients indicate that the nanostructured sensors employed in this study were able to distinguish between healthy and tumor tissue samples with coherent responses (the discrimination power of the most sensitive sensor was about 17%), highlighting a strong potential for clinical practice.

11.
Sensors (Basel) ; 20(5)2020 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-32143491

RESUMO

Preventive screening does not only allow to preemptively intervene on pathologies before they can harm the host; but also to reduce the costs of the intervention itself; boosting the efficiency of the NHS (National Health System) by saving resources for other purposes. To improve technology advancements in this field; user-friendly yet low-cost devices are required; and various applications for gas sensors have been tested and proved reliable in past studies. In this work; cell cultures and blood samples have been studied; using nanostructured chemoresistive sensors; to both verify if this technology can reliably detect tumor markers; and if correlations between responses from tumor line metabolites and the screening outcomes on human specimens could be observed. The results showed how sensors responded differently to the emanations from healthy and mutant (for cells) or tumor affected (for blood) samples, and how those results were consistent between them, since the tumoral specimens had higher responses compared to the ones of their healthy counterparts. Even though the patterns in the responses require a bigger population to be defined properly; it appeared that the different macro-groups between the same kind of samples are distinguishable from some of the sensors chosen in the study; giving promising outcomes for further research.


Assuntos
Biomarcadores Tumorais/sangue , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Células/metabolismo , Programas de Rastreamento , Nanoestruturas/química , Adulto , Idoso , Idoso de 80 Anos ou mais , Animais , Linhagem Celular , Humanos , Pessoa de Meia-Idade , Adulto Jovem
12.
Biophys Chem ; 253: 106230, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31352142

RESUMO

The neuronal Ca2+-sensor guanylate cyclase-activating protein 3 (zGCAP3) is a major regulator of guanylate cyclase (GC) activity expressed in zebrafish cone cells. Here, the zGCAP3, or a monoclonal antibody directed against zGCAP3, was injected in the cone cytoplasm by employing the pressure-polished pipette technique. This technique allows to perform "real time" zGCAP3 (or of any other phototransduction protein) over-expression or knock-down, respectively, via the patch pipette. Photoresponses were not affected by purified zGCAP3, indicating that GC was already saturated with endogenous zGCAP3. The cytosolic injection of anti-zGCAP3 produced the slowing down kinetics of the flash response recovery, as theoretically expected by a minimal phototransduction model considering the antibody acting exclusively on the maximal GC activation by low Ca2+. However, the antibody produced a progressive current decay toward the zero level, as if the antibody affected also the basal GC activity in the dark.


Assuntos
Proteínas Ativadoras de Guanilato Ciclase/metabolismo , Transdução de Sinal Luminoso , Células Fotorreceptoras Retinianas Cones/metabolismo , Animais , Anticorpos Monoclonais/metabolismo , Cálcio/metabolismo , Pressão , Peixe-Zebra
13.
Oxid Med Cell Longev ; 2017: 4256519, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29290903

RESUMO

While surgery is the definitive treatment for early-stage melanoma, the current therapies against advanced melanoma do not yet provide an effective, long-lasting control of the lesions and a satisfactory impact on patient survival. Thus, research is also focused on novel treatments that could potentiate the current therapies. In the present study, we evaluated the effect of potassium ascorbate with ribose (PAR) treatment on the human melanoma cell line, A375, in 2D and 3D models. In the 2D model, in line with the current literature, the pharmacological treatment with PAR decreased cell proliferation and viability. In addition, an increase in Connexin 43 mRNA and protein was observed. This novel finding was confirmed in PAR-treated melanoma cells cultured in 3D, where an increase in functional gap junctions and a higher spheroid compactness were observed. Moreover, in the 3D model, a remarkable decrease in the size and volume of spheroids was observed, further supporting the treatment efficacy observed in the 2D model. In conclusion, our results suggest that PAR could be used as a safe adjuvant approach in support to conventional therapies for the treatment of melanoma.


Assuntos
Antineoplásicos/farmacologia , Ácido Ascórbico/química , Proliferação de Células/efeitos dos fármacos , Potássio/química , Ribose/química , Antineoplásicos/química , Antineoplásicos/uso terapêutico , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Conexina 43/genética , Conexina 43/metabolismo , Humanos , Melanoma/tratamento farmacológico , Melanoma/patologia , Microscopia Eletrônica de Varredura , Esferoides Celulares/efeitos dos fármacos , Esferoides Celulares/ultraestrutura
14.
Methods Mol Biol ; 1548: 255-269, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28013510

RESUMO

Many short peptides selectively permeabilize the bacteria plasma membrane, leading to their lyses and death: they are therefore a source of antibacterial molecules and inspiration for novel and more selective drugs, which may have wider application in many other fields, as selective anticancer drugs. In this chapter, it is presented a new method to investigate the permeabilization properties of antimicrobial peptides under strict physiological conditions, employing the patch-clamp technique coupled to a fast perfusion system.


Assuntos
Peptídeos Catiônicos Antimicrobianos/farmacologia , Permeabilidade da Membrana Celular/efeitos dos fármacos , Membrana Celular/efeitos dos fármacos , Membrana Celular/metabolismo , Técnicas de Patch-Clamp , Animais , Células CHO , Cricetulus , Fenômenos Eletrofisiológicos/efeitos dos fármacos , Potenciais da Membrana/efeitos dos fármacos , Técnicas de Patch-Clamp/instrumentação , Técnicas de Patch-Clamp/métodos
15.
PLoS One ; 10(10): e0141727, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26513584

RESUMO

The phototransduction enzymatic cascade in cones is less understood than in rods, and the zebrafish is an ideal model with which to investigate vertebrate and human vision. Therefore, here, for the first time, the zebrafish green cone photoresponse is characterized also to obtain a firm basis for evaluating how it is modulated by exogenous molecules. To this aim, a powerful method was developed to obtain long-lasting recordings with low access resistance, employing pressure-polished patch pipettes. This method also enabled fast, efficient delivery of molecules via a perfusion system coupled with pulled quartz or plastic perfusion tubes, inserted very close to the enlarged pipette tip. Sub-saturating flashes elicited responses in different cells with similar rising phase kinetics but with very different recovery kinetics, suggesting the existence of physiologically distinct cones having different Ca2+ dynamics. Theoretical considerations demonstrate that the different recovery kinetics can be modelled by simulating changes in the Ca2+-buffering capacity of the outer segment. Importantly, the Ca2+-buffer action preserves the fast response rising phase, when the Ca2+-dependent negative feedback is activated by the light-induced decline in intracellular Ca2+.


Assuntos
Transdução de Sinal Luminoso , Células Fotorreceptoras Retinianas Cones/fisiologia , Animais , Cálcio/metabolismo , Fenômenos Eletrofisiológicos , Luz , Transdução de Sinal Luminoso/efeitos da radiação , Microscopia de Fluorescência , Técnicas de Patch-Clamp , Peixe-Zebra
16.
Molecules ; 19(7): 9228-39, 2014 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-24991756

RESUMO

The membrane-destabilization properties of the recently-introduced endosomolytic CM18-Tat11 hybrid peptide (KWKLFKKIGAVLKVLTTG-YGRKKRRQRRR, residues 1-7 of cecropin-A, 2-12 of melittin, and 47-57 of HIV-1 Tat protein) are investigated in CHO-K1 cells by using the whole-cell configuration of the patch-clamp technique. CM18-Tat11, CM18, and Tat11 peptides are administered to the cell membrane with a computer-controlled micro-perfusion system. CM18-Tat11 induces irreversible cell-membrane permeabilization at concentrations (≥4 µM) at which CM18 triggers transient pore formation, and Tat11 does not affect membrane integrity. We argue that the addition of the Tat11 module to CM18 is able to trigger a shift in the mechanism of membrane destabilization from "toroidal" to "carpet", promoting a detergent-like membrane disruption. Collectively, these results rationalize previous observations on CM18-Tat11 delivery properties that we believe can guide the engineering of new modular peptides tailored to specific cargo-delivery applications.


Assuntos
Peptídeos Penetradores de Células/farmacologia , Proteínas Recombinantes de Fusão/farmacologia , Animais , Células CHO , Permeabilidade da Membrana Celular , Cricetinae , Cricetulus , Potenciais da Membrana , Técnicas de Patch-Clamp
17.
Methods Mol Biol ; 1183: 279-89, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25023316

RESUMO

Whole-cell recording is the most widely used configuration of the patch recording technique, mainly because it allows to manipulate the intracellular environment while recording membrane current. However, the patch pipette tapered shank and the small tip opening give high access resistances and preclude efficient exchange between pipette solution and cell cytosol. Independently by the recording configuration, another problem of this technique is to gain consistently tight seals.Here we describe a method to enlarge the pipette shank without affecting the tip opening diameter, through the calibrated combination of heat and air pressure, with a custom-made inexpensive setup. These pressure-polished pipettes give small access resistances and allow for the accommodation of pulled quartz or plastic perfusion tubes very close to the pipette tip (to deliver exogenous molecules into the cytosol with a controlled timing). Finally, we describe a method to consistently attain seals with pipettes made from just one glass type, for a wide variety of cell types, isolated from different amphibian, reptilian, fish, and mammalian tissues, and on artificial membranes composed of many different lipid mixtures.


Assuntos
Compostos de Boro/química , Técnicas de Patch-Clamp/instrumentação , Perfusão/instrumentação , Silicatos/química , Animais , Desenho de Equipamento , Vidro/química , Humanos , Membranas Artificiais , Técnicas de Patch-Clamp/métodos , Perfusão/métodos , Pressão
18.
Nat Commun ; 4: 1541, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23443569

RESUMO

Muscle strength declines with age in part due to a decline of Ca(2+) release from sarcoplasmic reticulum calcium stores. Skeletal muscle dihydropyridine receptors (Ca(v)1.1) initiate muscle contraction by activating ryanodine receptors in the sarcoplasmic reticulum. Ca(v)1.1 channel activity is enhanced by a retrograde stimulatory signal delivered by the ryanodine receptor. JP45 is a membrane protein interacting with Ca(v)1.1 and the sarcoplasmic reticulum Ca(2+) storage protein calsequestrin (CASQ1). Here we show that JP45 and CASQ1 strengthen skeletal muscle contraction by modulating Ca(v)1.1 channel activity. Using muscle fibres from JP45 and CASQ1 double knockout mice, we demonstrate that Ca(2+) transients evoked by tetanic stimulation are the result of massive Ca(2+) influx due to enhanced Ca(v)1.1 channel activity, which restores muscle strength in JP45/CASQ1 double knockout mice. We envision that JP45 and CASQ1 may be candidate targets for the development of new therapeutic strategies against decay of skeletal muscle strength caused by a decrease in sarcoplasmic reticulum Ca(2+) content.


Assuntos
Canais de Cálcio Tipo L/metabolismo , Proteínas de Ligação ao Cálcio/deficiência , Proteínas de Membrana/deficiência , Força Muscular/fisiologia , Animais , Sinalização do Cálcio , Proteínas de Ligação ao Cálcio/metabolismo , Calsequestrina , Regulação da Expressão Gênica , Técnicas In Vitro , Manganês/metabolismo , Potenciais da Membrana/fisiologia , Proteínas de Membrana/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Contração Muscular/fisiologia , Fibras Musculares Esqueléticas/fisiologia
19.
Cell Calcium ; 53(3): 180-6, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23261317

RESUMO

The Ca(2+) modulation of pore formation (and disaggregation) kinetics of a synthetic analog of alamethicin F50/5 ([l-Glu(OMe)(7,18,19)]), a potent antibiotic peptide, was investigated in situ and in vitro. The in situ experiments consisted in whole-cell recording from isolated retinal rod outer segments (OS), because once blocking the only OS endogenous conductance with saturating light, the current flows entirely through the (exogenous) channels formed by the peptide. The kinetics of current change induced by peptide application and removal (in ∼50ms) on the OS extracellular side was measured in the presence of divalent cations at different concentrations. The in vitro experiments consisted on the divalent cations modulation of [l-Glu(OMe)(7,18,19)] binding to a mimetic OS membrane immobilized on a sensor chip surface, employing surface plasmon resonance spectroscopy (SPR). The presence of even low mM Ca(2+) or Mg(2+) sufficed to increase the [l-Glu(OMe)(7,18,19)] apparent affinity for the mimetic OS membrane up to ∼4-fold, which accelerated the activation of the peptide-induced current in OS by ∼10-fold with respect to low Ca(2+). In situ and in vitro experiments indicate that high concentrations of divalent cations increased also membrane rigidity, contrasting their effect on increasing the pore formation rate.


Assuntos
Alameticina/análogos & derivados , Antibacterianos/metabolismo , Cálcio/farmacologia , Cátions Bivalentes/farmacologia , Membrana Celular/metabolismo , Oligopeptídeos/metabolismo , Segmento Externo da Célula Bastonete/química , Animais , Antibacterianos/química , Sítios de Ligação/efeitos dos fármacos , Cálcio/química , Cátions Bivalentes/metabolismo , Membrana Celular/efeitos dos fármacos , Cinética , Magnésio/química , Magnésio/farmacologia , Oligopeptídeos/química , Ranidae , Segmento Externo da Célula Bastonete/metabolismo
20.
Eur Biophys J ; 40(11): 1215-23, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21761372

RESUMO

When performing whole-cell configuration recordings, it is important to minimize series resistance to reduce the time constant of charging the cell membrane capacitance and to reduce error in membrane potential control. To this end, an existing method was improved by widening the patch pipette shank through the calibrated combination of heat and air pressure. The heat was produced by passing current through a filament that was shaped appropriately to ensure a homogeneous heating of the pipette shank. Pressurized air was applied to the lumen of a pipette, pulled from a borosilicate glass microcap, via the pressure port of a modified commercial holder. The pipette reshaping was viewed on an LCD monitor connected to a contrast-intensified CCD camera and coupled to a modified bright-field stereomicroscope. By appropriately regulating the timing of air pressure and the application of heating, the pipette shank and, independently, the tip opening diameter were widened as desired. The methods illustrated here to fabricate and use the patch pipettes, using just one glass type, allowed the sealing of a wide variety of cell types isolated from different amphibian, reptilian, fish, and mammalian tissues as well as a variety of artificial membranes made with many different lipid mixtures. The access resistance yielded by pressure-polished pipettes was approximately one-fourth the size of the one attained with conventional pipettes; besides improving the electrical recordings, this minimized intracellular ion accumulation or depletion as well. Enlarged shank geometry allowed for fast intracellular perfusion as shown by fluorescence imaging, also via pulled quartz or plastic tubes, which could be inserted very close to the pipette tip.


Assuntos
Membrana Celular , Espaço Intracelular , Membranas Artificiais , Técnicas de Patch-Clamp/instrumentação , Perfusão/instrumentação , Pressão , Ar , Animais , Calibragem , Linhagem Celular , Impedância Elétrica , Vidro/química , Temperatura Alta , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA