1.
Metabolites ; 12(5)2022 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-35629913

RESUMO

Advances in magnet technologies have led to next generation 7T magnetic resonance scanners which can fit in the footprint and price point of conventional hospital scanners (1.5−3T). It is therefore worth asking if there is a role for 7T magnetic resonance imaging and spectroscopy for the treatment of solid tumor cancers. Herein, we survey the medical literature to evaluate the unmet clinical needs for patients with pancreatic and hepatic cancer, and the potential of ultra-high field proton imaging and phosphorus spectroscopy to fulfil those needs. We draw on clinical literature, preclinical data, nuclear magnetic resonance spectroscopic data of human derived samples, and the efforts to date with 7T imaging and phosphorus spectroscopy. At 7T, the imaging capabilities approach histological resolution. The spectral and spatial resolution enhancements at high field for phospholipid spectroscopy have the potential to reduce the number of exploratory surgeries due to tumor boundaries undefined at conventional field strengths. Phosphorus metabolic imaging at 7T magnetic field strength, is already a mainstay in preclinical models for molecular phenotyping, energetic status evaluation, dosimetry, and assessing treatment response for both pancreatic and liver cancers. Metabolic imaging of primary tumors and lymph nodes may provide powerful metrics to aid staging and treatment response. As tumor tissues contain extreme levels of phospholipid metabolites compared to the background signal, even spectroscopic volumes containing less than 50% tumor can be detected and/or monitored. Phosphorus spectroscopy allows non-invasive pH measurements, indicating hypoxia, as a predictor of patients likely to recur. We conclude that 7T multiparametric approaches that include metabolic imaging with phosphorus spectroscopy have the potential to meet the unmet needs of non-invasive location-specific treatment monitoring, lymph node staging, and the reduction in unnecessary surgeries for patients undergoing resections for pancreatic cancer. There is also potential for the use of 7T phosphorous spectra for the phenotyping of tumor subtypes and even early diagnosis (<2 mL). Whether or not 7T can be used for all patients within the next decade, the technology is likely to speed up the translation of new therapeutics.

2.
NMR Biomed ; 33(4): e4221, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31922319

RESUMO

High field 31 P spectroscopy has thus far been limited to diffuse liver disease. Unlike lower field-strength scanners, there is no body coil in the bore of the 7 T and despite inadequate penetration depth (<10 cm), surface coils are the current state-of-the-art for acquiring anatomical images to support multinuclear studies. We present a system of proton antennas and phosphorus loops for 31 P spectroscopy and provide the first ultrahigh-field phosphorus metabolic imaging of a tumor in the abdomen. Herein we characterize the degree to which antennas are isolated from underlying loops. Next, we evaluate the penetration depth of the two antennas available during multinuclear examinations. Finally, we combine phosphorus spectroscopy (two loops) with parallel transmit imaging (eight antennas) in a patient. The loops and antennas are inherently decoupled (no added circuitry, <0.1% power coupling). The penetration depth of two antennas gives twice that of conventional loops. The liver and full axial slice of the abdomen were imaged with eight transmit/receive antennas using parallel transmit B1-shimming to overcome image voids. Phosphorus spectroscopy from a liver metastasis resolved individual peaks for phosphocholine and phosphoethenalomine. Proton antennas are inherently decoupled from phosphorus loops. By using two proton antennas it is possible to perform region-of-interest image-based shimming in over 80% of the liver volume, thereby enabling phosphorus spectroscopy of localized disease. Shimming of the full extent of the abdominal cross-section is feasible using a parallel transmit array of eight antennas. A system architecture capable of supporting eight-channel parallel transmit and multinuclear spectroscopy is optimal for supporting multiparametric body imaging, including metabolic imaging, for monitoring the response of patients with liver metastases to cancer treatments and for patient risk stratification. In the meantime, the existing infrastructure using two antennas is sufficient for preliminary studies in metabolic imaging of tumors in the liver.


Assuntos
Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/metabolismo , Imageamento por Ressonância Magnética , Fósforo/química , Prótons , Adulto , Feminino , Humanos , Neoplasias Hepáticas/secundário
3.
Magn Reson Med ; 83(2): 765-775, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31441537

RESUMO

PURPOSE: The design and performance of a novel head coil setup for 31 P spectroscopy at ultra-high field strengths (7T) is presented. The described system supports measurements at both the 1 H and 31 P resonance frequencies. METHODS: The novel coil consists of 2, actively detunable, coaxial birdcage coils to give homogeneous transmit, combined with a double resonant 30 channel receive array. This allows for anatomical imaging combined with 31 P acquisitions over the whole head, without changing coils or disturbing the subject. A phosphate buffer phantom and 3 healthy volunteers were scanned with a pulse acquire CSI sequence using both the novel array coil and a conventional transceiver birdcage. Four different methods of combining the array channels were compared at 3 different levels of SNR. RESULTS: The novel coil setup delivers significantly increased 31 P SNR in the peripheral regions of the brain, reaching up to factor 8, while maintaining comparable performance relative to the birdcage in the center. CONCLUSIONS: The new system offers the potential to acquire whole brain 31 P MRSI with superior signal relative to the standard options.


Assuntos
Encéfalo/diagnóstico por imagem , Cabeça/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Fósforo/química , Razão Sinal-Ruído , Desenho de Equipamento , Voluntários Saudáveis , Humanos , Imagens de Fantasmas , Prótons
4.
PLoS One ; 14(3): e0213107, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30830934

RESUMO

BACKGROUND: The quality of carotid wall MRI can benefit substantially from a dedicated RF coil that is tailored towards the human neck geometry and optimized for image signal-to-noise ratio (SNR), parallel imaging performance and RF penetration depth and coverage. In last decades, several of such dedicated carotid coils were introduced. However, a comparison of the more successful designs is still lacking. OBJECTIVE: To perform a head-to-head comparison over four dedicated MR carotid surface coils with 4, 6, 8 and 30 coil elements, respectively. MATERIAL AND METHODS: Ten volunteers were scanned on a 3T scanner. For each subject, multiple black-blood carotid vessel wall images were measured using the four coils with different parallel imaging settings. The performance of the coils was evaluated and compared in terms of image coverage, penetration depth and noise correlations between elements. Vessel wall of a common carotid section was delineated manually. Subsequently, images were assessed based on vessel wall morphology and image quality parameters. The morphological parameters consisted of the vessel wall area, thickness, and normalized wall index (wall area/total vessel area). Image quality parameters consisted of vessel wall SNR, wall-lumen contrast-to-noise ratio (CNR), the vessel g-factor, and CNRindex ((wall-lumen signal) / (wall+lumen signal)). Repeated measures analysis of variance (rmANOVA) was applied for each parameter for the averaged 10 slices for all volunteers to assess effect of coil and SENSE factor. If the rmANOVA was significant, post-hoc comparisons were conducted. RESULTS: No significant coil effect were found for vessel wall morphological parameters. SENSE acceleration affected some morphological parameters for 6- and 8-channel coils, but had no effect on the 30-channel coil. The 30-channel coil achieved high acceleration factors (10x) with significantly lower vessel g-factor values (ps ≤ 0.01), but lower vessel wall SNR and CNR values (ps ≤ 0.01). CONCLUSION: All four coils were capable of high-quality carotid MRI. The 30-channel coil is recommended when rapid image acquisition acceleration is required for 3D measurements, whereas 6- and 8-channel coils demonstrated the highest SNR performance.


Assuntos
Artérias Carótidas/anatomia & histologia , Imageamento por Ressonância Magnética/instrumentação , Intensificação de Imagem Radiográfica/métodos , Adulto , Algoritmos , Artérias Carótidas/diagnóstico por imagem , Feminino , Voluntários Saudáveis , Humanos , Masculino , Imagens de Fantasmas , Razão Sinal-Ruído , Adulto Jovem
5.
Magn Reson Med ; 76(4): 1314-24, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-26480019

RESUMO

PURPOSE: The design of RF coils for MRI transmit becomes increasingly challenging at high frequencies required for MRI at 7T and above. Our goal is to show a proof of principle of a new type of transmit coil for higher field strengths. METHOD: We demonstrate an alternative transmit coil design based on dielectric waveguide principles which transfers energy via evanescent wave coupling. The operating principles and conditions are explored by simulations. The waveguide is applied for in vivo imaging at 7T. RESULTS: The waveguide can be an efficient transmit coil when four conditions are fulfilled: (1) the waveguide should be operated just above the cutoff frequency of the lowest order transverse electric mode, (2) the waveguide should not operate at a frequency where the wavelength fits an integer number of times in the waveguide length and standing wave patterns become very prominent, (3) for homogeneous excitation, the waveguide should be bent around the object, and (4) there should be an air gap between the waveguide and the object. CONCLUSIONS: By choosing the dielectric and the dimensions adequately, the dielectric waveguide couples the magnetic field efficiently into the body. The waveguide can be redesigned for higher frequencies by simple adaptations and may be a promising transmit alternative. Magn Reson Med 76:1314-1324, 2016. © 2015 Wiley Periodicals, Inc.


Assuntos
Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Transdutores , Desenho Assistido por Computador , Impedância Elétrica , Transferência de Energia , Desenho de Equipamento , Análise de Falha de Equipamento , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
MAGMA ; 28(1): 49-56, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24862451

RESUMO

OBJECTIVE: To identify a shielding material compatible with optical head-motion tracking for prospective motion correction and which minimizes radio frequency (RF) radiation losses at 7 T without sacrificing line-of-sight to an imaging target. MATERIALS AND METHODS: We evaluated a polyamide mesh coated with silver. The thickness of the coating was approximated from the composition ratio provided by the material vendor and validated by an estimate derived from electrical conductivity and light transmission measurements. The performance of the shield is compared to a split-copper shield in the context of a four-channel transmit-only loop array. RESULTS: The mesh contains less than a skin-depth of silver coating (300 MHz) and attenuates light by 15 %. Elements of the array vary less in the presence of the mesh shield as compared to the split-copper shield indicating that the array behaves more symmetrically with the mesh shield. No degradation of transmit efficiency was observed for the mesh as compared to the split-copper shield. CONCLUSION: We present a shield compatible with future integration of camera-based motion-tracking systems. Based on transmit performance and eddy-current evaluations the mesh shield is appropriate for use at 7 T.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Dispositivos Ópticos , Proteção Radiológica/instrumentação , Ondas de Rádio , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento
7.
Magn Reson Med ; 73(5): 2038-46, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-24903409

RESUMO

PURPOSE: Neoadjuvant treatment response in lymph nodes predicts patient outcome, but existing methods do not track response during therapy accurately. In this study, specialized hardware was used to adapt high-field (7T) (31) P magnetic resonance spectroscopy (MRS), which has been shown to track treatment response in small breast tumors, to monitor axillary lymph nodes. METHOD: A dual-tuned quadrature coil that is a (31) P (120 MHz) transceiver and a (1) H (300 MHz) receiver was designed using a novel detune circuit. The transceiver/receiver coil in the axilla is used with a fractionated dipole antenna on the back of the subject and the conventional breast coil for transmit. RESULTS: The novel circuit detuned the (1) H resonance without disturbing the (31) P resonance. In vivo demonstrations included: >80% homogeneous B1 (+) for (1) H over the axilla, identification of a small (3-mm diameter) lymph node, and (31) P MR spectra from a single healthy lymph node. The setup can detect <2 millimolar concentrations of metabolites from a 2-mL voxel. CONCLUSIONS: The first (31) P MR spectrum from an in vivo lymph node indicates that the presented design may be sufficiently sensitive to detect metabolic response to neoadjuvant therapy. Multinuclei MRS of the lymph nodes at 7T is possible through combining lightweight antenna elements with dual-tuned transceiver/receive-only coils.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/terapia , Metástase Linfática/diagnóstico , Imageamento por Ressonância Magnética/instrumentação , Espectroscopia de Prótons por Ressonância Magnética/instrumentação , Adulto , Axila , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Humanos , Linfonodos/patologia , Metástase Linfática/patologia , Terapia Neoadjuvante , Imagens de Fantasmas , Prognóstico , Valores de Referência , Sensibilidade e Especificidade
8.
Magn Reson Med ; 71(2): 524-33, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23440917

RESUMO

PURPOSE: A novel highly accurate method for MR thermometry, effective at high field, is introduced and validated, which corrects for slow and fast field fluctuations by means of reference images. METHODS: An asymmetric spin-echo echo planar imaging sequence was made frequency-selective to water or a reference substance by controlling the slice-select gradient polarity and the duration of the excitation and refocusing radiofrequency pulses. Images were acquired pairwise, and the temperature-sensitive water images were corrected for field fluctuations using the reference images. In a phantom radiofrequency heating experiment, dissolved dimethyl sulfoxide was used as a reference substance. Temperature stability was tested in vivo on the human brain, referenced using subcutaneous scalp fat. Water and fat phase images were acquired only 50 ms apart. Bloch simulations validated the frequency selection accuracy. RESULTS: Asymmetric spin-echo imaging using a simple frequency selection method provides highly accurate referenced MR thermometry in phantoms and in vivo at 7 T. Effects of field fluctuations caused by field drift, breathing, and heart beat were corrected. The technique is highly robust against B1 inhomogeneities. CONCLUSION: Frequency selection using gradient-reversal can enable fast accurate referenced in vivo MR thermometry, assisting thermal characterization of radiofrequency coils and possibly in vivo SAR monitoring.


Assuntos
Imagem Ecoplanar/métodos , Termometria/métodos , Encéfalo/fisiologia , Humanos , Imagens de Fantasmas