1.
Membranes (Basel) ; 12(12)2022 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-36557089

RESUMO

For absorption cooling cycles using water as a refrigerant, H2O/LiCl mixtures are suitable for replacing conventional H2O/LiBr mixtures. In addition, membrane devices can be used to develop compact and lighter absorption systems, and they can operate with H2O/LiCl mixtures. The present paper describes an experimental evaluation of a membrane desorber/condenser operating at atmospheric pressure. Two operation modes were analyzed: continuous cycle operation and intermittent operation. For the first operation mode, the maximum desorption rate was 3.49 kg/h·m2, with a solution temperature of 90.3 °C and a condensation temperature of 25.1 °C. The lowest desorption rate value was 0.26 kg/h·m2, with a solution temperature of 75.4 °C and a condensation temperature of 40.1 °C. In the second mode, after three operating hours, the refrigerant fluid produced, per 1 m2 of membrane area, 7.7, 5.6, 4.3, and 2.2 kg, at solution temperatures of 90.3, 85.3, 80.4, and 75.4 °C, respectively. A one-dimension heat and mass transfer model is presented. The calculated values of desorption rate and outlet temperatures were compared with the experimental data; a square correlation coefficient of 0.9929 was reached for the desorption rate; meanwhile, for the outlet solution temperatures and the outlet cooling-water temperatures, a square correlation coefficient up to 0.9991 was achieved. The membrane desorber has the advantages of operating at atmospheric-pressure conditions, high condensation temperature, the ability to use different saline solution working mixtures, and different operation methods. These advantages can lead to new absorption systems.

2.
Membranes (Basel) ; 11(7)2021 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-34206822

RESUMO

In absorption systems using the aqueous lithium bromide mixture, the Coefficient of Performance is affected by the desorber. The main function of this component is to separate the refrigerant fluid from the working mixture. In conventional boiling desorbers, constant heat flux and vacuum pressure conditions are necessary to carry out the desorption process, and usually, the absorbers are heavy and bulky; thus, they are not suitable in compact systems. In this study, a membrane desorber was evaluated, operating at atmospheric pressure conditions with a water/lithium bromide solution with a concentration of 49.6% w/w. The effects of the solution temperature, solution mass flow, and condensation temperature on the desorption rate were analyzed. The maximum desorption rate value was 6.1 kg/m2h with the following operation conditions: the solution temperature at 95.2 °C, the solution mass flow at 4.00 × 10-2 kg/s, and the cooling water temperature at 30.1 °C. On the other hand, the minimum value was 1.1 kg/m2h with the solution temperature at 80.2 °C, the solution mass flow at 2.50 × 10-2 kg/s, and the cooling water temperature at 45.1 °C. The thermal energy efficiency, defined as the ratio between the thermal energy used to evaporate the refrigerant fluid with respect to the total thermal energy entering the membrane desorber, varied from 0.08 to 0.30. According to the results, a high solution mass flow, a high solution temperature, and a low condensation temperature lead to an increase in the desorption rate; however, a low solution mass flow enhanced the thermal energy efficiency. The proposed membrane desorber could replace a conventional boiling desorber, especially in absorption cooling systems that operate at high condensation temperatures as in warm weather regions.

3.
Membranes (Basel) ; 10(9)2020 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-32878062

RESUMO

The role of heat pumps is linked to the actions of human life. Even though the existing technologies perform well in general, they have still some problems, such as cost, installation area, components size, number of components, noise, etc. To address these issues, membrane technologies have been introduced in both heat and cooling devices. The present work proposes and studied the review of the role of membrane technology in the heat pumps. The study focuses on the advancement and replacement of membrane in the place of absorption and compression heat pump components. The detailed analysis and improvements are focused on the absorber, desorber, and heat and mass exchanger. The parameters conditions and operation of membrane technologies are given in detail. In addition to this, the innovation in the heat pumps using the membrane technology is given in detail.

4.
Ginecol Obstet Mex ; 76(6): 341-8, 2008 Jun.
Artigo em Espanhol | MEDLINE | ID: mdl-18800591

RESUMO

Postpartum depression is a multifactorial condition suffered by 15% of women after delivery. We report a clinical case of a 32 years old female admitted at Postpartum depression clinic of gyneco-obstetric coordination at Centro Médico Nacional 20 de Noviembre, ISSTE, Mexico City. Patient was evaluated by psychiatric and psychological service personnel and diagnosed as with postpartum depression. She was admitted with her child during two weeks to be studied and treated. Several evaluation tests were applied and specific interventions by multidisciplinary team were designed.