Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-30323051

RESUMO

Multiplex PCR combined with a pharmacist-driven reporting protocol was compared to the standard of care within a community hospital to evaluate initial changes after notification of a positive blood culture. The intervention group demonstrated decreased times to changes in antimicrobial therapy (P = 0.0081), increased changes to optimal antimicrobial therapy (P = 0.013), and decreased vancomycin use for coagulase-negative staphylococcus contaminants (P < 0.01) with multiplex PCR implementation and pharmacist intervention.


Assuntos
Antibacterianos/uso terapêutico , Gestão de Antimicrobianos/estatística & dados numéricos , Bacteriemia/tratamento farmacológico , Hemocultura/estatística & dados numéricos , Farmacêuticos/estatística & dados numéricos , Tempo para o Tratamento/estatística & dados numéricos , Bacteriemia/diagnóstico , Bacteriemia/microbiologia , Técnicas de Tipagem Bacteriana , Bactérias Gram-Negativas/classificação , Bactérias Gram-Negativas/efeitos dos fármacos , Bactérias Gram-Negativas/isolamento & purificação , Bactérias Gram-Positivas/classificação , Bactérias Gram-Positivas/efeitos dos fármacos , Bactérias Gram-Positivas/isolamento & purificação , Hospitais Comunitários , Humanos , Reação em Cadeia da Polimerase Multiplex , Estudos Retrospectivos
2.
Drug Saf ; 41(6): 591-602, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29411338

RESUMO

INTRODUCTION: We previously found a high rate of errors in the administration of intravenous medications using smart infusion pumps. OBJECTIVES/DESIGN: An infusion safety intervention bundle was developed in response to the high rate of identified errors. A before-after observational study with a prospective point-prevalence approach was conducted in nine hospitals to measure the preliminary effects of the intervention. MAIN OUTCOME MEASURES: Primary outcome measures were overall errors and medication errors, with the secondary outcome defined as potentially harmful error rates. RESULTS: We assessed a total of 418 patients with 972 medication administrations in the pre-intervention period and 422 patients with 1059 medication administrations in the post-intervention period. The overall error rate fell from 146 to 123 per 100 medication administrations (p < 0.0001), and the medication error rate also decreased from 39 to 29 per 100 medication administrations (p = 0.001). However, there was no significant change in the potentially harmful error rate (from 0.5 to 0.8 per 100 medication administrations, p = 0.37). An intervention component aiming to reduce labeling-not-completed errors was effective in reducing targeted error rates, but other components of the intervention bundle did not show significant improvement in the targeted errors. CONCLUSION: Development and implementation of the intervention bundle was successful at reducing overall and medication error rates, but some errors remained and the potentially harmful error rate did not change. The error-rate reductions were not always correlated with the specific individual interventions. Further investigation is needed to identify the best strategies to reduce the remaining errors. CLINICAL TRIALS REGISTRATION: Registered at ClinicalTrials.gov, identifier: NCT02359734.


Assuntos
Infusões Intravenosas/efeitos adversos , Erros de Medicação/prevenção & controle , Preparações Farmacêuticas/administração & dosagem , Hospitais , Humanos , Bombas de Infusão/efeitos adversos , Sistemas de Medicação no Hospital , Prevalência , Estudos Prospectivos
3.
BMJ Qual Saf ; 26(2): 131-140, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-26908900

RESUMO

INTRODUCTION: Intravenous medication errors persist despite the use of smart pumps. This suggests the need for a standardised methodology for measuring errors and highlights the importance of identifying issues around smart pump medication administration in order to improve patient safety. OBJECTIVES: We conducted a multisite study to investigate the types and frequency of intravenous medication errors associated with smart pumps in the USA. METHODS: 10 hospitals of various sizes using smart pumps from a range of vendors participated. Data were collected using a prospective point prevalence approach to capture errors associated with medications administered via smart pumps and evaluate their potential for harm. RESULTS: A total of 478 patients and 1164 medication administrations were assessed. Of the observed infusions, 699 (60%) had one or more errors associated with their administration. Identified errors such as labelling errors and bypassing the smart pump and the drug library were predominantly associated with violations of hospital policy. These types of errors can result in medication errors. Errors were classified according to the National Coordinating Council for Medication Error Reporting and Prevention (NCC MERP). 1 error of category E (0.1%), 4 of category D (0.3%) and 492 of category C (excluding deviations of hospital policy) (42%) were identified. Of these, unauthorised medication, bypassing the smart pump and wrong rate were the most frequent errors. CONCLUSION: We identified a high rate of error in the administration of intravenous medications despite the use of smart pumps. However, relatively few errors were potentially harmful. The results of this study will be useful in developing interventions to eliminate errors in the intravenous medication administration process.


Assuntos
Bombas de Infusão/estatística & dados numéricos , Infusões Intravenosas/estatística & dados numéricos , Humanos , Auditoria Médica , Erros de Medicação/prevenção & controle , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA