Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
Transplant Direct ; 10(8): e1686, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39035117

RESUMO

Background: Organ allocation in the United States to non-US citizen, non-US residents who travel for transplant (NC/NRTx) is controversial. Current policies may not be informed by stakeholder opinions, as limited data exist assessing the knowledge or opinions of providers or patients on this issue. Methods: A cross-sectional, hospital-based pilot survey was distributed to providers and patients from December 2019 to June 2020 at a single large urban transplant institute. Providers were members of the departments of surgery and medicine and included both transplant and nontransplant providers. Surveys included 10 questions on eligibility, prioritization, and limitations for deceased donor transplantation and 12 demographic questions. Results: A total of 209 providers responded (61% women, median age 40) and 119 patients responded (62% women, median age 54). Awareness of eligibility for transplantation of US citizens, non-US citizens residing in the United States (NC/R), and NC/NRTx was high in both groups, though providers and patients lacked awareness of the eligibility of nonlegal NC/R (those who live in the United States who are not citizens and are not legal residents) to donate and receive organs. Overall, 79.3% of patients stated that NC/NRTx should be eligible for transplant in the United States compared with only 60.7% of providers (P = 0.001). Providers were more likely than patients to prioritize transplant to legal NC/NR over NC/NRTx (58.2% versus 35.1%, P < 000.1) and reported that families should be able to limit donations to NC/NRTx (34.9% versus 23.2%, P = 0.03). Conclusions: Surveyed patients and providers generally support transplant in non-US citizens; however, the strength of support varied considerably based on the legal status of the patient and the occupation of those surveyed. Larger studies are necessary to develop data-informed policy.

2.
BMJ Open Qual ; 12(2)2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37339821

RESUMO

BACKGROUND: BMA guidance recommends all hospitals provide suitable, comfortable and convenient period products. In 2018, none of Scotland's health boards had policies on sanitary product provision. AIM: Establish current provision at Glasgow Royal Infirmary.Improve provision for staff and patients.Improve working experience for staff while menstruating. METHODS: Cycle 0: A pilot survey was circulated to assess current provision, availability and impact on working environment.Cycle 1: The survey was circulated to all hospital staff. Suppliers were contacted for donations. Two menstrual hubs were established in the medical receiving unit.Cycle 2: Polling confirmed the preferred mode of downstream product distribution, with products supplied to each ward. Menstrual hub use was monitored.Cycle 3: Staff were resurveyed following the interventions. Findings were presented to hospital and board managers. RESULTS: Cycle 0: 95% felt current provision for staff was not appropriate. 77% felt provisions were inappropriate for patients (n=22).Cycle 1: 97% felt hospital period product provisions were not appropriate. 84% of menstruators had no access to products when required: 55% asked colleagues for products; 50% used makeshift products and 8% used hospital pads. Overall, 84% did not know where to access period products within the hospital (n=968).Cycle 2: 91% preferred ward-based provisions (n=46).Cycle 3: 95% agreed that project period products were suitable for their needs (n=71). 82% felt access to period products had improved for personal use and 47% for patients. 58% were able to locate products for staff and 49% for patients. CONCLUSION: Project period highlighted a need for menstrual product provision in hospitals. It increased knowledge, suitability and availability of period products, and created a robust model of provision which may be easily replicated.


Assuntos
Hospitais Urbanos , Humanos , Inquéritos e Questionários
3.
J Cardiothorac Surg ; 18(1): 117, 2023 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-37038197

RESUMO

BACKGROUND: While the pledget suture technique has been the standard for surgical aortic. valve replacement (AVR), discussion continues regarding the possibility of the nonpledget suture technique to produce superior structural and hemodynamic parameters. This study aims to assess the effectiveness of the figure-of-eight suture technique in AVR, as determined by the incidence of prosthesis-patient mismatch (PPM). METHODS: We reviewed records of patients (N = 629) who underwent a surgical AVR procedure between January 2011 and July 2018 at a single institution. Indexed effective orifice area values and PPM incidence were calculated from implanted valve size and patient body surface area. Incidence of none, moderate, and severe PPM was compared across AVR suture techniques. RESULTS: A total of 570 pledget and 59 figure-of-eight patients were compared for incidence of PPM. Patients who received AVR with the pledget suture technique had significantly lower echocardiographic measurements of baseline ejection fraction than patients who had received AVR with the figure-of-eight suture technique (p = 0.003). Patients who received the figure-of eight suture had a 14% decrease in moderate PPM compared to patients who received the pledget suture (p = 0.022). Patients who received the figure-of-eight suture also had a significantly higher rate of no PPM (p = 0.044). CONCLUSIONS: The use of the figure-of-eight suture technique in AVR can reduce the incidence of moderate PPM. While the pledget suture is the standard technique in AVR, the figure-of-eight suture technique may offer better structural and hemodynamic outcomes, especially for patients with a smaller aortic annulus.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Desenho de Prótese , Técnicas de Sutura
4.
Artif Organs ; 2022 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-36574590

RESUMO

PURPOSE: Tolvaptan, a selective vasopressin type-2 antagonist, has been shown to increase serum sodium (Na) and urine output in hyponatremic left ventricular assist device (LVAD) patients in retrospective studies. In this prospective randomized pilot study, we aimed to assess the efficacy of tolvaptan in this population. METHODS: We conducted a prospective, randomized, non-blinded pilot study of LVAD recipients with post-operative hyponatremia (Na < 135 mEq/L) (NCT05408104). Eligible participants were randomized to receive tolvaptan 15 mg daily in addition to usual care versus usual care alone. The primary outcome was a change in Na level and estimated glomerular filtration rate (eGFR), from the first post-operative day of hyponatremia (the day of randomization) to discharge. RESULTS: A total of 33 participants were enrolled, and 28 underwent randomization (median age 55 [IQR 50-62]), 21% women, 54% Black, 32% ischemic cardiomyopathy, median baseline Na 135 (IQR 134-138). Fifteen participants were randomized to tolvaptan (TLV) and 13 were randomized to usual care alone (No-TLV). Mean change in Na from randomization to discharge in the TLV group was 2.7 mEq/L (95%CI 0.7-4.7, p = 0.013) and 1.8 (95%CI 0.5-4.0, p = 0.11) in the No-TLV group, though baseline and final Na levels were similar between groups. The mean change in eGFR was 2.6 ml/min/1.73 m2 (95%CI 10.1-15.3, p = 0.59) in TLV versus 7.5 ml/min/1.73 m2 (95%CI 5.2-20.2, p = 0.15) in No-TLV. TLV participants had significantly more urine output than No-TLV patients during their first 24 h after randomization (3294 vs 2155 ml, p = 0.043). CONCLUSION: TLV significantly increases urine output, with nominal improvement in Na level, in hyponatremic post-operative LVAD patients without adversely impacting renal function.

5.
JVS Vasc Sci ; 3: 182-191, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35495567

RESUMO

Objective: Many patients who require hemodialysis treatment will often require a prosthetic graft after multiple surgeries. However, the patency rate of grafts currently available commercially has not been satisfactory. Tissue engineering vascular grafts (TEVGs) are biodegradable scaffolds created to promote autologous cell proliferation and functional neotissue regeneration and, accordingly, have antithrombogenicity. Therefore, TEVGs can be an alternative prosthesis for small diameter grafts. However, owing to the limitations of the graft materials, most TEVGs are rigid and can easily kink when implanted in limited spaces, precluding future clinical application. Previously, we developed a novel corrugated nanofiber graft to prevent graft kinking. Reinforcement of these grafts to ensure their safety is required in a preclinical study. In the present study, three types of reinforcement were applied, and their effectiveness was examined using large animals. Methods: In the present study, three different reinforcements for the graft composed of corrugated poly-ε-caprolactone (PCL) blended with poly(L-lactide-co-ε-caprolactone) (PLCL) created with electrospinning were evaluated: 1) a polydioxanone suture, 2) a 2-0 polypropylene suture, 3) a polyethylene terephthalate/polyurethane (PET/PU) outer layer, and PCL/PLCL as the control. These different grafts were then implanted in a U-shape between the carotid artery and jugular vein in seven ovine models for a total of 14 grafts during a 3-month period. In evaluating the different reinforcements, the main factors considered were cell proliferation and a lack of graft dilation, which were evaluated using ultrasound examinations and histologic and mechanical analysis. Results: No kinking of the grafts occurred. Overall, re-endothelialization was observed in all the grafts at 3 months after surgery without graft rupture or calcification. The PCL/PLCL grafts and PCL/PLCL grafts with a polydioxanone suture showed high cell infiltration; however, they had become dilated 10 weeks after surgery. In contrast, the PCL/PLCL graft with the 2-0 suture and the PCL/PLCL graft covered with a PET/PU layer did not show any graft expansion. The PCL/PLCL graft covered with a PET/PU layer showed less cell infiltration than that of the PCL/PLCL graft. Conclusions: Reinforcement is required to create grafts that can withstand arterial pressure. Reinforcement with suture materials has the potential to maintain cell infiltration into the graft, which could improve the neotissue formation of the graft.

6.
Artif Organs ; 46(8): 1626-1635, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35230709

RESUMO

BACKGROUND: Patients with concomitant anemia and congestive heart failure have poor outcomes. The prevalence and clinical risk of anemia in patients receiving durable left ventricular assist devices (LVAD) remain unknown. METHODS: We retrospectively analyzed patients who underwent LVAD implantation between 2014 and 2018. The association between hemoglobin level at the time of index discharge and the one-year composite endpoint of heart failure readmissions or hemocompatibility-related adverse events was investigated. RESULTS: A total of 168 patients (57 [48, 66] years old, 123 males) were included and stratified into a classification of anemia (hemoglobin <9.7 g/dl, N = 99) or non-anemia (N = 69). The anemia group had a higher one-year incidence of the composite endpoint (56% vs 36%, p = .013) with an adjusted hazard ratio of 1.83 (95% confidence interval 1.08-2.82). Patients with anemia also experienced suboptimal bi-ventricular unloading. CONCLUSIONS: Anemia was prevalent in LVAD patients and associated with a greater risk of heart failure and hemocompatibility-related adverse events. The optimal threshold for therapeutic intervention in response to post-LVAD anemia needs further investigation.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Idoso , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
7.
Am J Hypertens ; 35(5): 407-413, 2022 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-35171213

RESUMO

BACKGROUND: Measuring an accurate blood pressure (BP) in ambulatory patients is critical for therapeutic decisions. An accurate noninvasive device that measures BP continuously could provide a more comprehensive assessment of BP. The aim of this study was to determine whether the LiveOne device, a cuffless wristband that provides continuous BP measurements, is accurate in comparison to an invasive arterial line (A-line). METHODS: We enrolled hospitalized patients and healthy volunteers in this multicenter study. All patients had an invasive A-line. Waveforms were simultaneously downloaded from the A-line and LiveOne device. The primary outcome was the correlation between the LiveOne device and the A-line for systolic BP (SBP) and diastolic BP (DBP). RESULTS: Thirty-four patients with 233 measurement periods were included. Mean age was 60.7 ± 15.2 years, and 15 (44%) were female. The correlation for SBP was 0.91 and for DBP was 0.85. The mean band error was 0.0 ± 6.9 mm Hg for SBP and 1.2 ± 5.7 mm Hg for DBP. The mean absolute error was 8.2 ± 5.8 mm Hg for SBP and 6.4 ± 3.9 mm Hg for DBP. For SBP, 98% of LiveOne measurements were within 15 mm Hg and for DBP, 92% of LiveOne measurements were within 10 mm Hg. CONCLUSIONS: The LiveOne device provides continuous, noninvasive BP measurements that are accurate in comparison to A-line measurements. The portability and unobtrusive nature of this device and the ability to provide continuous BP measurements may offer advantages over currently available BP monitors. CLINICAL TRIALS REGISTRATION: Trial Number NCT03919136.


Assuntos
Determinação da Pressão Arterial , Hipertensão , Idoso , Pressão Sanguínea/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esfigmomanômetros , Punho
9.
Clin Transplant ; 35(4): e14242, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33539043

RESUMO

BACKGROUND: Capillary deposition of C4d is an important marker of antibody-mediated rejection (AMR) following heart transplantation (HT). There are two immunopathologic assay methods for detecting C4d: frozen-tissue immunofluorescence (IF) and paraffin immunohistochemistry (IHC). The clinical significance of discrepancy between the results of IF and IHC has not been understood. METHODS AND RESULTS: We reviewed 2187 biopsies from 142 HT recipients who had biopsies with assessment of both IF and IHC staining. Among them, 103 (73%) patients had negative IF and IHC C4d staining (Negative Group) and 32 (23%) patients had positive IF but negative IHC staining (Discordant Group). At the time of positive biopsy, 6 (19%) Discordant patients had graft dysfunction, compared to 5 (5%) Negative patients (p = .022). Cumulative incidence of cellular rejection at 1 year was comparable (31% vs. 29%, p = .46); however, cumulative incidence of AMR was significantly higher in the Discordant group (21% vs. 4%, p = .004). Overall 1-year survival was comparable (90% vs. 96%, p = .24); however, freedom from heart failure (HF) was significantly lower in the Discordant group (70% vs. 96%, p < .001). CONCLUSION: The Discordant group showed higher rates of graft dysfunction, AMR and HF admission than the Negative group.


Assuntos
Complemento C4b , Transplante de Coração , Biópsia , Imunofluorescência , Rejeição de Enxerto/diagnóstico , Rejeição de Enxerto/etiologia , Humanos , Imuno-Histoquímica , Fragmentos de Peptídeos , Coloração e Rotulagem
10.
Transplant Proc ; 53(2): 673-680, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33358419

RESUMO

BACKGROUND: Hyperkalemia (HK) is a life-threatening complication following solid organ transplantation, and patients often need potassium-chelating agents and deviations from standard posttransplant protocols. This is the first study to report the incidence and clinical impact of hyperkalemia following heart transplantation. METHODS: We retrospectively included patients who underwent heart transplantation at our institution between April 2014 and December 2018. Patients with multiorgan transplantation were excluded. Clinical outcomes of patients who had serum potassium >5.5 mEq/L in the first year posttransplant (HK group) were compared to patients who did not have serum potassium >5.5 mEq/L in the first year posttransplant (non-HK group). RESULTS: A total of 143 patients were included in this study. During the first year posttransplant, cumulative incidence of serum potassium >5.0, >5.5, and >6.0 mEq/L was 96%, 63%, and 24%, respectively. Fifty-five percent of patients required treatment with potassium-chelating agents. Sulfamethoxazole-trimethoprim was discontinued because of HK in 39% of patients. Overall survival of patients in the HK group (n = 89) was comparable to that of patients in the non-HK group (n = 54, 91% vs 98% at 1 year, P = .19), whereas infection-free survival was significantly lower in the HK group (34% vs 53% at 1 year, P = .010). Multivariate analysis revealed pretransplant renal dysfunction (odds ratio = 2.62; 95% confidence interval, 1.18-5.80; P = .018) and use of mechanical circulatory support (odds ratio = 2.90; 95% confidence interval, 1.08-7.76; P = .035) as significant predictors of posttransplant hyperkalemia. CONCLUSIONS: The incidence of HK following heart transplantation was high, with more than half of patients requiring any therapeutic interventions, and HK was related to an increase in infection events.


Assuntos
Transplante de Coração/efeitos adversos , Hiperpotassemia/epidemiologia , Hiperpotassemia/etiologia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Adulto , Idoso , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Potássio/sangue , Estudos Retrospectivos , Fatores de Risco
11.
Artif Organs ; 45(3): 297-302, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33098153

RESUMO

Aortic insufficiency remains a difficult to treat and highly morbid condition even in the era of HeartMate 3 left ventricular assist devices (LVADs). The prognostic nature of the longitudinal progression of aortic insufficiency, however, remains unknown. We prospectively collected data on patients who received HeartMate 3 LVAD implantation, who had assessments of aortic insufficiency using a novel Doppler echocardiography obtained at outflow graft at three (baseline) and 6 months postimplant. Patients with moderate or greater aortic insufficiency at baseline were excluded. The risk of aortic insufficiency progression on 1-year death and readmission for heart failure was investigated. In total, 41 patients (median 51 years old and 29 males) were included. All patients had less than moderate aortic insufficiency at baseline. Of them, 22 patients had worsening aortic insufficiency for 3 months following baseline assessments, which was associated with a significantly higher risk of 1-year death or heart failure readmission rate (41% vs. 11%, P = .023) with a hazard ratio of 3.24 (95% confidence interval 1.02-18.5, P = .038) adjusted for device speed at baseline and destination therapy indication. In patients with HeartMate 3 LVADs, progressive aortic insufficiency may be associated with a higher risk of 1-year death or readmission for heart failure. Close monitoring of patients with baseline aortic insufficiency should be considered as a measure to risk-stratify those for future adverse events.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Complicações Pós-Operatórias/diagnóstico , Adulto , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Progressão da Doença , Ecocardiografia Doppler , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente/estatística & dados numéricos , Complicações Pós-Operatórias/etiologia , Modelos de Riscos Proporcionais , Estudos Prospectivos , Estudos Retrospectivos , Índices de Gravidade do Trauma , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
12.
Clin Transplant ; 34(12): e14087, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32955148

RESUMO

Hypogammaglobulinemia (HGG) can occur following solid organ transplantation. However, there are limited data describing the prevalence, risk factors, and clinical outcomes associated with HGG following heart transplantation. We retrospectively reviewed data of 132 patients who had undergone heart transplantation at our institution between April 2014 and December 2018. We classified patients into three groups based on the lowest serum IgG level post-transplant: normal (≥700 mg/dL), mild HGG (≥450 and <700 mg/dL), and severe HGG (<450 mg/dL). We compared clinical outcomes from the date of the lowest IgG level. Mean age was 57 (47, 64) years, and 94 (71%) patients were male. Prevalence of severe HGG was the highest (27%) at 3-6 months following heart transplantation and then decreased to 5% after 1 year. Multivariate analysis showed that older age and Caucasian race were independent risk factors for HGG. Overall survival was comparable between the groups; however, survival free of infection was 73%, 60%, and 45% at 1 year in the normal, mild HGG, and severe HGG groups, respectively (P = .013). In conclusion, there is a high prevalence of HGG in the early post-heart transplant period that decreases over time. HGG is associated with an increased incidence of infection.


Assuntos
Agamaglobulinemia , Transplante de Coração , Agamaglobulinemia/epidemiologia , Agamaglobulinemia/etiologia , Feminino , Transplante de Coração/efeitos adversos , Humanos , Imunoglobulina G , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Fatores de Risco
13.
ASAIO J ; 66(8): 881-885, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32740347

RESUMO

Neurohormonal blockade (NHB) is the mainstay of therapy for patients with systolic heart failure (HF). However, the efficacy in patients with left ventricular assist devices (LVADs) remains unknown. Of all, 114 LVAD patients (57 [48, 65] years old and 78% male) were enrolled and followed during the early period (6 months after index discharge), and 98 were followed during the late period (6-12 months following index discharge). Of them, 46% were on beta-blocker (BB), 49% on angiotensin-converting enzyme inhibitor (ACEi) and/or angiotensin II receptor blocker (ARB), and 51% on aldosterone antagonist at baseline. Prevalence of BB and ACEi/ARB use increased during the study period. During the early period, similar event rates were found irrespective of the NHB uses. During the late period, BB was associated with reduced HF readmission, and ACEi/ARB was associated with reduced HF readmission and gastrointestinal bleeding (p < 0.05 for all). In conclusion, BB and ACEi/ARB use during the late period was associated with a reduction in HF recurrence in LVAD patients. Further prospective randomized control trials are warranted to clarify the utility of NHB therapy in LVAD patients.


Assuntos
Antagonistas Adrenérgicos beta/uso terapêutico , Antagonistas de Receptores de Angiotensina/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Insuficiência Cardíaca/terapia , Coração Auxiliar , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neurotransmissores/antagonistas & inibidores , Estudos Retrospectivos
14.
Artif Organs ; 44(12): e509-e519, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32557769

RESUMO

Cannula position in HeartMate II and HeartWare left ventricular assist devices (LVADs) is associated with clinical outcome. This study aimed to investigate the clinical implication of the device positioning in HeartMate 3 LVAD cohort. Consecutive patients who underwent HeartMate 3 LVAD implantation were followed for one year from index discharge. At index discharge, chest X-ray parameters were measured: (a) cannula coronal angle, (b) height of pump bottom, (c) cannula sagittal angle, and (d) cannula lumen area. The association of each measurement of cannula position with one-year clinical outcomes was investigated. Sixty-four HeartMate 3 LVAD patients (58 years old, 64% male) were enrolled. In the multivariable Cox regression model, the cannula coronal angle was a significant predictor of death or heart failure readmission (hazard ratio 1.27 [1.01-1.60], P = .045). Patients with a cannula coronal angle ≤28° had lower central venous pressure (P = .030), lower pulmonary capillary wedge pressure (P = .027), and smaller left ventricular size (P = .019) compared to those with the angle >28°. Right ventricular size and parameters of right ventricular function were also better in the narrow angle group, as was one-year cumulative incidence of death or heart failure readmission (10% vs. 50%, P = .008). Narrow cannula coronal angle in patients with HeartMate 3 LVADs was associated with improved cardiac unloading and lower incidence of death or heart failure readmission. Larger studies to confirm the implication of optimal device positioning are warranted.


Assuntos
Cânula/efeitos adversos , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Implantação de Prótese/métodos , Adulto , Idoso , Ecocardiografia , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente/estatística & dados numéricos , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
15.
J Card Fail ; 26(10): 863-869, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32473380

RESUMO

BACKGROUND: Aortic insufficiency (AI) is associated with morbidity and mortality in patients with continuous-flow left ventricular assist devices (LVADs), whereas its impact on the HeartMate 3 LVAD cohorts remains uninvestigated. We aimed to investigate the clinical impact of AI on patients with HeartMate 3 LVADs. METHODS AND RESULTS: Consecutive 61 patients (median age 54 years; 67% male) implanted with HeartMate 3 LVAD between 2015 and 2019 were enrolled and underwent echocardiography at 3 months after LVAD implantation. AI severity was quantified by the novel Doppler echocardiographic method obtained at the outflow cannula and the calculated regurgitation fraction of 30% or greater (moderate or greater) was defined as significant. At 3 months after implant, 12 patients (20%) had significant AI. They had a higher incidence of death or heart failure readmissions compared with those without significant AI during a 1-year observational period (70% vs 24%, P = .003) with an adjusted hazard ratio of 2.76 (95% confidence interval 1.03-7.88). CONCLUSIONS: In patients with HeartMate 3 LVAD support, significant AI remains both prevalent and a clinically significant downstream complication.


Assuntos
Insuficiência da Valva Aórtica , Insuficiência Cardíaca , Coração Auxiliar , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/epidemiologia , Insuficiência da Valva Aórtica/etiologia , Pré-Escolar , Ecocardiografia , Ecocardiografia Doppler , Feminino , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Estudos Retrospectivos
16.
J Am Heart Assoc ; 9(7): e014801, 2020 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-32223394

RESUMO

Background Decoupling between diastolic pulmonary artery pressure and pulmonary capillary wedge pressure is an index of pulmonary vascular damage. This study assessed the impact of decoupling on right heart function and hemocompatibility-related adverse events. Methods and Results In this prospective study, patients underwent invasive hemodynamic tests following left ventricular assist device implantation. Decoupling was defined as a difference of >5 mm Hg between diastolic pulmonary artery pressure and pulmonary capillary wedge pressure. Among 92 patients with left ventricular assist devices (median age, 61 years; 57% male), 44 patients (48%) had decoupling. Right heart function and size by echocardiographic assessment worsened during a 1-year observational period in the decoupling group as compared with the control group (P<0.05). The decoupling group had significantly lower 1-year freedom from any hemocompatibility-related adverse events (49% versus 79%; P=0.005), as well as a higher hemocompatibility score (2.14 versus 0.67; P=0.004). The scoring system depicts the severity of hemocompatibility-related adverse events using 4 escalating tiers. Increased tier I scores (1-2 gastrointestinal bleedings or medically managed pump thrombosis; P=0.027) and tier IIIB scores (disabling stroke or hemocompatibility-related adverse event-related death; P=0.041) occurred more frequently in the decoupling group. Conclusions The presence of decoupling between diastolic pulmonary artery pressure and pulmonary capillary wedge pressure was associated with worsening of right heart function and hemocompatibility-related adverse events in patients with left ventricular assist devices.


Assuntos
Pressão Arterial , Insuficiência Cardíaca/terapia , Coração Auxiliar , Hipertensão Pulmonar/fisiopatologia , Implantação de Prótese/efeitos adversos , Artéria Pulmonar/fisiopatologia , Pressão Propulsora Pulmonar , Disfunção Ventricular Direita/etiologia , Idoso , Feminino , Hemorragia Gastrointestinal/etiologia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/mortalidade , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Implantação de Prótese/instrumentação , Implantação de Prótese/mortalidade , Fatores de Risco , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Direita/mortalidade , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Esquerda , Função Ventricular Direita
17.
Ann Thorac Surg ; 110(3): 911-917, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32035046

RESUMO

BACKGROUND: HeartWare ventricular assist device (HVAD) cannula position is associated with hemodynamics and heart failure readmissions. However, its impact on hemocompatibility-related adverse events (HRAEs) remains uncertain. METHODS: HVAD patients were followed for 1 year after index hospitalization, when cannula coronal angle was quantified from chest x-ray film. Invasive right heart catheterization and transthoracic echocardiography were performed. One-year occurrences of each HRAE were compared between those with and without a cannula coronal angle of greater than 65 degrees. RESULTS: Among 63 HVAD patients (median age 60 years, 63% male), 10 (16%) had a cannula coronal angle greater than 65 degrees. The wide-angle group had elevated intracardiac pressures and lower pulmonary artery pulsatility index (P < .05). They also had reduced right ventricular function by echocardiography. Freedom from HRAEs tended to be lower in the wide-angle group (24% vs 62%; P = .11). The rate of gastrointestinal bleeding was significantly higher in the greater than 65 degrees group (0.90 events/year vs 0.40 events/year; P = .013). The rates of stroke and pump thrombosis were statistically comparable irrespective of cannula angle (P > .05). CONCLUSIONS: HVAD cannula coronal angle was associated with reduced right ventricular function and HRAEs. Prospective studies evaluating surgical techniques to ensure optimal device positioning and its effects on HRAEs are warranted.


Assuntos
Cânula/efeitos adversos , Cateterismo Cardíaco/instrumentação , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Função Ventricular Esquerda/fisiologia , Idoso , Ecocardiografia , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
18.
Ann Thorac Surg ; 110(3): 918-924, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32035052

RESUMO

BACKGROUND: Tricuspid regurgitation (TR) is common in advanced heart failure (HF) patients. However, the effect of concomitant tricuspid valve repair or replacement (tricuspid valve intervention [TVI]) with left ventricular assist device (LVAD) implantation is controversial. The aim of this study was to investigate the longitudinal trend of TR after LVAD implantation and the effect of TVI on the TR trend and clinical outcomes. METHODS: We retrospectively reviewed patients at our institution who underwent LVAD implantation between April 2014 and August 2018. We evaluated the grade of TR by echocardiography before and after LVAD implantation. Moderate or greater TR was defined as significant. RESULTS: Among 199 consecutive patients, 194 had at least 2 echocardiographic TR assessments before and after LVAD implantation. Of these patients, 108 were included in the TVI-positive (TVI+) group and 86 in the TVI-negative (TVI-) group. In the TVI+ group, the prevalence of significant TR decreased from 52% to about 20% in the first 6 months after implantation (P < .01). Overall survival and HF readmission-free survival were comparable between the TVI+ and TVI- patients. In contrast, patients in both groups who had significant postoperative TR during early follow-up had worse 2-year HF readmission-free survival (36% in patients with significant postoperative TR vs 55% in those without significant postoperative TR; P = .028). CONCLUSIONS: Concomitant TVI with LVAD implantation improved TR in most patients but did not have an impact on clinical outcomes. Significant postoperative TR after LVAD implantation, in patients with and without TVI, was associated with worse HF-free outcomes.


Assuntos
Insuficiência Cardíaca/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Coração Auxiliar , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Idoso , Ecocardiografia , Feminino , Seguimentos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/etiologia
19.
J Card Fail ; 26(5): 383-390, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32027961

RESUMO

BACKGROUND: Continuous-flow left ventricular assist devices (LVADs) improve the hemodynamics of patients with advanced heart failure. However, the longitudinal trajectories of hemodynamics in patients after LVAD implantation remain unknown. The aim of this study was to investigate the trends of hemodynamic parameters following LVAD implantation. METHODS AND RESULTS: We retrospectively reviewed patients who underwent LVAD implantation between April 2014 and August 2018. We collected hemodynamic parameters from right heart catheterizations. Of 199 consecutive patients, we enrolled 150 patients who had both pre- and postimplant right heart catheterizations. They had 3 (2, 4) postimplant right heart catheterizations during a follow-up of 2.3 (1.3, 3.1) years. The mean age was 57 ± 13 years, and 102 patients (68%) were male. Following LVAD implantation, pulmonary arterial pressure and pulmonary capillary wedge pressure decreased, and cardiac index increased significantly, then remained unchanged throughout follow-up. Right atrial pressure decreased initially and then gradually increased to preimplant values. The pulmonary artery pulsatility index decreased initially and returned to preimplant values, then progressively decreased over longer follow-up. Subgroup analysis showed significant differences in the trajectories of the pulmonary artery pulsatility index based on gender. CONCLUSIONS: Despite improvement in left-side filling pressures and cardiac index following LVAD implantation, right atrial pressure increased and the pulmonary artery pulsatility index decreased over time, suggesting progressive right ventricular dysfunction.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Disfunção Ventricular Direita , Insuficiência Cardíaca/cirurgia , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
20.
J Card Fail ; 26(4): 342-348, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31981696

RESUMO

BACKGROUND: HVAD left ventricular assist device flow waveforms provides graphical real-time information linking device performance with invasive hemodynamics. Previous studies have demonstrated a good correlation between the slopes of the ventricular filling phase slope (VFPS) and directly measured pulmonary capillary wedge pressure (PCWP). We aimed to validate the utility of VFPS to estimate PCWP and predict clinical outcomes. METHODS: In this prospective blinded study, screenshots from the HVAD monitor and simultaneous invasive hemodynamic measurements were obtained. Each screenshot was digitized and the VFPS was calculated by 2 independent reviewers who were blinded to the hemodynamic results. The equation PCWP = 7.053 +1.365 × (VFPS) was derived from a previously published dataset and the estimated PCWP was correlated to the actually measured PCWP. RESULTS: One hundred thirty-one sets of simultaneous measurements (VFPS and PCWP) were obtained from 27 HVAD patients (mean age 55 years, 47% male). A previously proposed cutoff of VFPS ≥5.8 L/min/s predicted PCWP ≥ 18 mmHg with 91.5% sensitivity and 95.2% specificity with the area under curve of 0.987. The estimated PCWP significantly correlated with measured PCWP (R2 = 0.65, P < .001) and showed acceptable agreement with measured PCWP. Patients with VFPS ≥ 5.8 L/min/s experienced significantly higher heart failure readmission rates than those without (0.24 vs 0.05 events/y, P < .001). CONCLUSIONS: VFPS of the HVAD flow waveform is a novel noninvasive parameter that can estimate PCWP.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Feminino , Insuficiência Cardíaca/diagnóstico , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Pressão Propulsora Pulmonar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA