Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Biosens Bioelectron X ; 12: 100222, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36118917

RESUMO

We report two novel genosensors for the quantification of SARS-CoV-2 nucleic acid using glassy carbon electrodes modified with a biocapture nanoplatform made of multi-walled carbon nanotubes (MWCNTs) non-covalently functionalized with avidin (Av) as a support of the biotinylated-DNA probes. One of the genosensors was based on impedimetric transduction offering a non-labelled and non-amplified detection of SARS-CoV-2 nucleic acid through the increment of [Fe(CN)6]3-/4- charge transfer resistance. This biosensor presented an excellent analytical performance, with a linear range of 1.0 × 10-18 M - 1.0 × 10-11 M, a sensitivity of (5.8 ± 0.6) x 102 Ω M-1 (r2 = 0.994), detection and quantification limits of 0.33 aM and 1.0 aM, respectively; and reproducibilities of 5.4% for 1.0 × 10-15 M target using the same MWCNTs-Av-bDNAp nanoplatform, and 6.9% for 1.0 × 10-15 M target using 3 different nanoplatforms. The other genosensor was based on a sandwich hybridization scheme and amperometric transduction using the streptavidin(Strep)-biotinylated horseradish peroxidase (bHRP)/hydrogen peroxide/hydroquinone (HQ) system. This genosensor allowed an extremely sensitive quantification of the SARS-CoV-2 nucleic acid, with a linear range of 1.0 × 10-20 M - 1.0 × 10-17 M, detection limit at zM level, and a reproducibility of 11% for genosensors prepared with the same MWCNTs-Av-bDNAp1 nanoplatform. As a proof-of-concept, and considering the extremely high sensitivity, the genosensor was challenged with highly diluted samples obtained from SARS-CoV-2 RNA PCR amplification.

2.
J Pharm Biomed Anal ; 189: 113478, 2020 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-32768875

RESUMO

MicroRNAs (miRNAs) are non-coding regulatory RNAs that play an important role in RNA silencing and post-transcriptional gene expression regulation. Since their dysregulation has been associated with Alzheimer disease, cardiovascular diseases and different types of cancer, among others, miRNAs can be used as biomarkers for early diagnosis and prognosis of these diseases. The methods commonly used to quantify miRNAs are, in general, complex, costly, with limited application for point-of-care devices or resource-limited facilities. Electrochemical biosensors, mainly those based on nanomaterials, have emerged as a promising alternative to the conventional miRNA detection methods and have paved the way to the development of sensitive, fast, and low-cost detection systems. This review is focused on the most relevant contributions performed in the field of electrochemical miRNAs biosensors between 2017 and the beginning of 2020. The main contribution of this article is the critical discussion of the different amplification strategies and the comparative analysis between amplified and non-amplified miRNA electrochemical biosensing and between the different amplification schemes. Particular emphasis was given to the importance of the nanostructures, enzymes, labelling molecules, and special sequences of nucleic acids or analogues on the organization of the different bioanalytical platforms, the transduction of the hybridization event and the generation the analytical signal.


Assuntos
Técnicas Biossensoriais , MicroRNAs , Nanoestruturas , Técnicas Eletroquímicas , MicroRNAs/genética , Hibridização de Ácido Nucleico
3.
Antioxidants (Basel) ; 8(6)2019 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-31242617

RESUMO

The growing interest in the chemistry of unsaturated ring-fused 1,3-heterocycles, in this particular case 1,3-oxazines, arise in part from their versatile pharmacological applications. In the present article, the evaluation of the in vitro and ex vivo antioxidant activity of two cyclohexene-fused oxazines is discussed. The in vitro antioxidant activity was evaluated by trapping the ABTS and hydroxyl radicals as well as the inhibition of the enzyme acetyl-cholinesterase and hemolysis of erythrocytes by 2,2'-Azobis(2-amidinopropane) dihydrochloride (AAPH). The results suggest that both unsaturated 1,3-oxazines are auspicious sources of biologically active compounds with good antioxidant properties. In addition, a comprehensive analysis of the interaction between these heterocycles with 2,2-diphenyl-1-picrylhydrazyl (DPPH) and 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid) (ABTS) radicals, as well as the measurements of redox potential, provided evidence for a mechanism of antioxidant activity that takes place through electron transfer (ET) processes.

4.
Biosens Bioelectron ; 41: 424-9, 2013 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-23017682

RESUMO

This work reports the characterization of a modified gold surface as a platform for the development of a label free aptasensor for thrombin detection. The biorecognition platform was obtained by the self-assembly of 4-mercaptobenzoic acid onto a gold surface, covalent attachment of streptavidin and further immobilization of the biotinylated anti-thrombin aptamer. The biosensing platform was characterized by cyclic voltammetry, electrochemical impedance spectroscopy, surface plasmon resonance (SPR) and quartz crystal microbalance with dissipation monitoring. The biorecognition event aptamer-thrombin was detected from changes in the SPR angle produced as a consequence of the molecular interaction between the aptasensor and the target protein. The biosensing platform demonstrated to be highly selective for human thrombin even in the presence of large excess of bovine thrombin, bovine serum albumin, cytochrome C, lysozyme and myoglobin. The relationship between the changes in the SPR angle and thrombin concentration was linear up to 0.19 µmol L(-1) (R(2)=0.992) while the detection limit was of 12.0 nmol L(-1) (240 fmol in the sample). This new sensing approach represents an interesting and promising alternative for the SPR-based quantification of thrombin.


Assuntos
Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/instrumentação , Testes de Coagulação Sanguínea/instrumentação , Condutometria/instrumentação , Imunoensaio/instrumentação , Trombina/análise , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Trombina/antagonistas & inibidores
5.
Talanta ; 80(5): 2149-56, 2010 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-20152465

RESUMO

This work reports on the performance of carbon nanotube modified screen-printed electrodes (SPE-MWCNT) for the selective determination of dopamine (DA) in the presence of ascorbic acid (AA) by adsorptive stripping voltammetry (AdSV). Several operating conditions and parameters were examined including the electrochemical pre-treatment and the previous AA interaction and DA accumulation in the presence AA at physiological conditions. Under the chosen conditions, DA peak current of differential pulse voltammograms increases linearly with DA concentration in the range of 5.0 x 10(-8) to 1.0 x 10(-6) mol L(-1) with a limit of detection of 1.5 x 10(-8) mol L(-1) in connection with 600s accumulation time. The sensitivity obtained for DA was independent from the presence or absence of AA; therefore, the proposed method can be readily applied to detect DA in real samples. The proposed methodology was successfully used for the quantification of DA in urine samples.


Assuntos
Ácido Ascórbico/urina , Dopamina/urina , Eletroquímica/instrumentação , Nanotubos de Carbono/química , Ácido Ascórbico/análise , Dopamina/análise , Eletroquímica/métodos , Eletrodos , Humanos , Limite de Detecção
6.
Talanta ; 78(1): 212-6, 2009 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-19174227

RESUMO

This work reports the advantages of a label free electrochemical aptasensor for the detection of lysozyme. The biorecognition platform was obtained by the adsorption of the aptamer on the surface of a carbon paste electrode (CPE) previously blocked with mouse immunoglobulin under controlled-potential conditions. The recognition event was detected from the decrease in the guanine and adenine electro-oxidation signals produced as a consequence of the molecular interaction between the aptamer and lysozyme. The biosensing platform demonstrated to be highly selective even in the presence of large excess (9-fold) of bovine serum albumin, cytochrome C and myoglobin. The reproducibility for 10 repetitive determinations of 10.0 mg L(-1) lysozyme solution was 5.1% and 6.8% for guanine and adenine electro-oxidation signals, respectively. The detection limits of the aptasensor were 36.0 nmol L(-1) (if considering guanine signal) and 18.0 nmol L(-1) (if taking adenine oxidation current). This new sensing approach represents an interesting and promising alternative for the electrochemical quantification of lysozyme.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais/métodos , Muramidase/análise , Eletroquímica/métodos , Eletrodos , Reprodutibilidade dos Testes
7.
J Nanosci Nanotechnol ; 8(11): 6003-9, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19198338

RESUMO

We report the highly selective and sensitive voltammetric dopamine quantification in the presence of ascorbic acid and serotonin by using glassy carbon electrodes modified with a dispersion of multi-wall carbon nanotubes (MWCNT) in polyethylenimine, PEI (GCE/MWCNT-PEI). The electrocatalytic activity of the MWCNT deposited on the glassy carbon electrode has allowed an important decrease in the overvoltages for the oxidation of ascorbic acid and dopamine, making possible a clear definition of dopamine, serotonin and ascorbic acid oxidation processes. The sensitivities for dopamine in the presence and absence of 1.0 mM ascorbic acid and serotonin were (2.18 +/- 0.03) x 10(5) microAM(-1) (r = 0.9998); and (2.10 +/- 0.07) x 10(5) miroAM(-1) (r=0.9985), respectively, demonstrating the excellent performance of the GCE/MWCNT-PEI. The detection limit for dopamine in the mixture was 9.2 x 10(-7) M. The R. S. D. for the determination of 50 microM dopamine using four different electrodes was 3.9% when modified with the same MWCNT/PEI dispersion, and 4.6% when using four different dispersions. The modified electrode has been successfully applied for recovery assays of dopamine in human blood serum. Therefore, the new sensor represents an interesting and promising alternative for the electrochemical quantification of neurotransmitters and other analytes of clinical interest.


Assuntos
Técnicas Biossensoriais/instrumentação , Dopamina/análise , Eletroquímica/instrumentação , Microeletrodos , Nanotecnologia/instrumentação , Nanotubos de Carbono/química , Polietilenoimina/química , Serotonina/análise , Ácido Ascórbico/química , Técnicas Biossensoriais/métodos , Coloides/química , Cristalização/métodos , Eletroquímica/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Vidro/química , Teste de Materiais , Microquímica/instrumentação , Microquímica/métodos , Nanotecnologia/métodos , Nanotubos de Carbono/ultraestrutura , Tamanho da Partícula , Sensibilidade e Especificidade
8.
Talanta ; 74(3): 291-307, 2007 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-18371643

RESUMO

The aim of this review is to summarize the most relevant contributions in the development of electrochemical (bio)sensors based on carbon nanotubes in the last years. Since the first application of carbon nanotubes in the preparation of an electrochemical sensor, an increasing number of publications involving carbon nanotubes-based sensors have been reported, demonstrating that the particular structure of carbon nanotubes and their unique properties make them a very attractive material for the design of electrochemical biosensors. The advantages of carbon nanotubes to promote different electron transfer reactions, in special those related to biomolecules; the different strategies for constructing carbon nanotubes-based electrochemical sensors, their analytical performance and future prospects are discussed in this article.


Assuntos
Técnicas Biossensoriais/instrumentação , Nanotubos de Carbono/química , Animais , DNA/análise , DNA/química , Eletroquímica , Eletrodos , Humanos
9.
Talanta ; 68(5): 1671-6, 2006 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-18970513

RESUMO

In this work, we demonstrate for the first time that 4-methyl-5-nitrocatechol (4M5NC) and 2,4,5-trihydroxytoluene (2,4,5-THT), two compounds obtained from the 2,4-DNT biodegradation are recognized by polyphenol oxidase as substrates. An amperometric biosensor is described for detecting these compounds and for evaluating the efficiency of the 2,4-DNT conversion into 4M5NC in the presence of bacteria able to produce the 2,4-DNT-biotransformation. The biosensor format involves the immobilization of polyphenol oxidase into a composite matrix made of glassy carbon microspheres and mineral oil. The biosensor demonstrated to be highly sensitive for the quantification of 4M5NC and 2,4,5-THT. The analytical parameters for 4M5NC are the following: sensitivity of (7.5+/-0.1)x10(5)nAM(-1), linear range between 1.0x10(-5) and 8.4x10(-5)M, and detection limit of 4.7x10(-6)M. The sensitivity for the determination of 2,4,5-THT is (6.2+/-0.6)x10(6)nAM(-1), with a linear range between 1.0x10(-6) and 5.8x10(-6)M, and a detection limit of 2.0x10(-7). Under the experimental conditions, it was possible to selectively quantify 4M5NC even in the presence of a large excess of 2,4-DNT. The suitability of the biosensor for detecting the efficiency of 2,4-DNT biotransformation into 4M5NC is demonstrated and compared with HPLC-spectrophotometric detection, with very good correlation. This biosensor holds great promise for decentralized environmental testing of 2,4-DNT.

10.
Chem Commun (Camb) ; (34): 4267-9, 2005 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-16113717

RESUMO

The recognition of proteins by aptamer-modified electrode transducers reverses the surface charge and leads to a novel label-free impedance spectroscopy bioelectronic detection protocol based on a decrease in the electron transfer resistance.


Assuntos
Técnicas Biossensoriais , Proteínas/química , Biotina/química , Impedância Elétrica , Eletroquímica , Eletrodos , Muramidase/química , Soluções , Espectrofotometria , Propriedades de Superfície
11.
Talanta ; 66(2): 467-71, 2005 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-18970008

RESUMO

The performance of amperometric glucose biosensors based on the dispersion of glucose oxidase (GOx) and copper oxide within a classical carbon (graphite) paste composite is reported in this work. Copper oxide promotes an excellent electrocatalytic activity towards the oxidation and reduction of hydrogen peroxide, allowing a large decrease in the oxidation and reduction overpotentials, as well as an important enhancement of the corresponding currents. Therefore, it is possible to perform the glucose biosensing at low potentials where there is no interference even in large excess of ascorbic acid, uric acid or acetaminophen. The influence of the copper oxide and glucose oxidase content in the paste on the analytical performance of the bioelectrode is discussed. The resulting biosensor shows a fast response, a linear relationship between current and glucose concentration up to 1.35 x 10(-2) M (2.43 g L(-1)) and a detection limit of 2.0 x 10(-5) M. The effect of the presence of the enzyme in the composite material on the dispersion of the copper oxide particles is also discussed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA