RESUMO
OBJECTIVE: This study aims to define the accuracy, predictive value, and interobserver reliability of magnetic resonance imaging (MRI) in the diagnosis of placenta accreta spectrum (PAS) disorders. STUDY DESIGN: Two experienced radiologists independently interpreted the MRI studies of patients with possible PAS from two referral centers. Radiologists were blinded to sonographic and clinical information. We calculated diagnostic testing characteristics and kappa statistics of interobserver reliability for MRI findings of PAS. RESULTS: Sixty-eight MRI cases were evaluated. Confirmed PAS and severe PAS were present in 44 (65%) and 20 (29%) cases. For the diagnosis of any PAS, MRI had a sensitivity 66%, specificity 71%, positive predictive value (PPV) 81%, negative predictive value (NPV) 53%, and accuracy 68%. For the diagnosis of severe PAS (percreta), MRI had a sensitivity 85%, specificity 79%, PPV 63%, NPV 93%, and accuracy 81%. The accuracy of individual signs of PAS was lower (44-65%). Interobserver agreement was almost perfect for previa; substantial for myometrial interruptions, PAS, severe PAS, and placental bulging/balling; and moderate to slight for other signs of PAS. CONCLUSION: Although the interobserver reliability of MRI for a diagnosis of PAS is substantial, the accuracy and predictive value are modest and lower than previously reported.
Assuntos
Imageamento por Ressonância Magnética , Variações Dependentes do Observador , Placenta Acreta/diagnóstico por imagem , Adulto , Feminino , Idade Gestacional , Humanos , Placenta/diagnóstico por imagem , Placenta Prévia/diagnóstico por imagem , Valor Preditivo dos Testes , Gravidez , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Útero/diagnóstico por imagemRESUMO
OBJECTIVE: Our aim was to evaluate the effect of umbilical cord milking on outcomes for preterm multiples. STUDY DESIGN: We implemented a policy of cord milking in neonates born at less than 30 weeks' gestation in September 2011. We compared cord milking in multiples with a historical cohort. Multivariable logistic regression models estimated the effect of cord milking on a composite neonatal adverse outcome. Secondary outcomes were hematocrit at birth, need for blood transfusion, and inotrope use. RESULTS: We identified 149 neonates (120 twins, 29 triplets), 51 historical controls, and 98 neonates with cord milking. Cord milking was associated with a lower rate of adverse composite neonatal outcome in univariable analysis (odds ratio [OR]: 0.36; 95% confidence interval [CI]: 0.15-0.84). However, in multivariable modeling, the effect was not significant (adjusted OR [aOR]: 0.54, 95% CI: 0.23-1.28). Hematocrit was 4.6 unit % (95% CI: 2-7.3) higher in the cord milking group, and cord milking was associated with a lower rate of blood transfusion (aOR: 0.28; 95% CI: 0.1-0.74; p = 0.01). There was no difference in inotrope administration. CONCLUSION: Umbilical cord milking was not associated with a decrease in composite neonatal adverse outcome. However, we observed an increase in hematocrit and decreased need for blood transfusion in neonates with cord milking.
Assuntos
Transfusão de Sangue , Hematócrito , Recém-Nascido Prematuro , Trigêmeos , Gêmeos , Cordão Umbilical , Estudos de Coortes , Feminino , Sangue Fetal , Humanos , Recém-Nascido , Doenças do Recém-Nascido/prevenção & controle , Recém-Nascido Prematuro/sangue , Modelos Logísticos , Masculino , Análise Multivariada , Gravidez , Gravidez Múltipla , Nascimento PrematuroRESUMO
Pharmacotherapy, or medication-assisted treatment (MAT), is a critical component of a comprehensive treatment plan for the pregnant woman with opioid use disorder (OUD). Methadone and buprenorphine are two types of opioid-agonist therapy which prevent withdrawal symptoms and control opioid cravings. Methadone is a long-acting mu-opioid receptor agonist that has been shown to increase retention in treatment programs and attendance at prenatal care while decreasing pregnancy complications. However methadone can only be administered by treatment facilities when used for OUD. In contrast, buprenorphine is a mixed opioid agonist-antagonist medication that can be prescribed outpatient. The decision to use methadone vs buprenorphine for MAT should be individualized based upon local resources and a patient-specific factors. There are limited data on the use of the opioid antagonist naltrexone in pregnancy. National organizations continue to recommend MAT over opioid detoxification during pregnancy due to higher rates of relapse with detoxification.
Assuntos
Analgésicos Opioides/efeitos adversos , Tratamento de Substituição de Opiáceos/métodos , Transtornos Relacionados ao Uso de Opioides/tratamento farmacológico , Complicações na Gravidez/tratamento farmacológico , Gestantes , Adulto , Buprenorfina/uso terapêutico , Feminino , Guias como Assunto , Humanos , Metadona/uso terapêutico , Antagonistas de Entorpecentes/uso terapêutico , GravidezAssuntos
Placenta Acreta , Feminino , Humanos , Imageamento por Ressonância Magnética , Gravidez , UltrassonografiaAssuntos
Placenta Acreta , Feminino , Humanos , Imageamento por Ressonância Magnética , Gravidez , UltrassonografiaRESUMO
BACKGROUND: Magnetic resonance imaging is reported to have good sensitivity and specificity in the diagnosis of placenta accreta spectrum disorders, and is often used as an adjunct to ultrasound. But the additional utility of obtaining magnetic resonance imaging to assist in the clinical management of patients with placenta accreta spectrum disorders, above and beyond the information provided by ultrasound, is unknown. OBJECTIVE: We aimed to determine whether magnetic resonance imaging provides data that may inform clinical management by changing the sonographic diagnosis of placenta accreta spectrum disorders. STUDY DESIGN: In all, 78 patients with sonographic evidence or clinical suspicion of placenta accreta spectrum underwent magnetic resonance imaging of the abdomen and pelvis in orthogonal planes through the uterus utilizing T1- and T2-weighted imaging sequences at the University of Utah and the University of Colorado from 1997 through 2017. The magnetic resonance imaging was interpreted by radiologists with expertise in diagnosis of placenta accreta spectrum who had knowledge of the sonographic interpretation and clinical risk factors for placenta accreta spectrum disorders. The primary outcome was a change in diagnosis from sonographic interpretation that could alter clinical management, which was defined a priori. Diagnostic accuracy was verified by surgical and histopathologic diagnosis at the time of delivery. RESULTS: A change in diagnosis that could potentially alter clinical management occurred in 28 (36%) cases. Magnetic resonance imaging correctly changed the diagnosis in 15 (19%), and correctly confirmed the diagnosis in 34 (44%), but resulted in an incorrect change in diagnosis in 13 (17%), and an incorrect confirmation of ultrasound diagnosis in 15 (21%). Magnetic resonance imaging was not more likely to change a diagnosis in the 24 cases of posterior and lateral placental location compared to anterior location (33% vs 37%, P = .84). Magnetic resonance imaging resulted in overdiagnosis in 23% and in underdiagnosis in 14% of all cases. When ultrasound suspected severe disease (percreta) in 14 cases, magnetic resonance imaging changed the diagnosis in only 2 cases. Lastly, the proportion of accurate diagnosis with magnetic resonance imaging did not improve over time (61-65%, P = .96 for trend) despite increasing volume and increasing numbers of changed diagnoses. CONCLUSION: Magnetic resonance imaging resulted in a change in diagnosis that could alter clinical management of placenta accreta spectrum disorders in more than one third of cases, but when changed, the diagnosis was often incorrect. Given its high cost and limited clinical value, magnetic resonance imaging should not be used routinely as an adjunct to ultrasound in the diagnosis of placenta accreta spectrum until evidence for utility is clearly demonstrated by more definitive prospective studies.
Assuntos
Imageamento por Ressonância Magnética , Placenta Acreta/diagnóstico por imagem , Ultrassonografia Pré-Natal , Adulto , Tomada de Decisão Clínica , Gerenciamento Clínico , Feminino , Humanos , Placenta Acreta/terapia , Gravidez , Estudos Retrospectivos , Sensibilidade e Especificidade , Índice de Gravidade de DoençaRESUMO
OBJECTIVE: Delayed umbilical cord clamping benefits extremely low gestational age neonates (ELGANs) but has not gained wide acceptance. We hypothesized that milking the umbilical cord (MUC) would avoid resuscitation delay but improve hemodynamic stability and reduce rates for composite outcome of severe intraventricular hemorrhage, necrotizing enterocolitis, and/or death before discharge. STUDY DESIGN: We implemented a joint neonatal/maternal-fetal quality improvement process for MUC starting September 2011. The MUC protocol specified that infants who were born at <30 weeks of gestation undergo MUC 3 times over a duration of <30 seconds at delivery. Obstetric and neonatal data were collected until discharge. We compared the MUC group to retrospective ELGAN cohort delivered at our center between January 2010 and August 2011. Analysis was intention-to-treat. RESULTS: We identified 318 ELGANs: 158 eligible for MUC and 160 retrospective control neonates. No adverse events were reported with cord milking. There was no difference in neonatal resuscitation, Apgar scores, or admission temperature. Hemodynamic stability was improved in the MUC group with higher mean blood pressures through 24 hours of age, despite less vasopressor use (18% vs 32%; P < .01). The initial hematocrit value was higher (50% vs 45%; P < .01), and red cell transfusions were fewer (57% vs 79%; P < .01) in MUC vs control infants. Presence of the composite outcome was significantly less in MUC vs the historic control infants (22% v 39%; odds ratio, 1.81; 95% confidence interval, 1.06-3.10). There were also reductions in intraventricular hemorrhage, necrotizing enterocolitis, and death before hospital discharge. CONCLUSION: MUC improves early hemodynamic stability and is associated with lower rates of serious morbidity and death among ELGANs.