Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Clin Oral Investig ; 28(1): 28, 2023 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-38147179

RESUMO

OBJECTIVES: This in vitro study is aimed at assessing whether implant primary stability is influenced by implant length in artificial bone with varying densities. MATERIALS AND METHODS: A total of 120 truncated-conical implants (60 long-length: 3p L, 3.8 × 14 mm; 60 short-length: 3p S, 3.8 × 8 mm) were inserted into 20, 30, and 40 pounds per cubic foot (PCF) density polyurethane blocks. The insertion torque (IT), removal torque (RT), and resonance frequency analysis (RFA) values were recorded for each experimental condition. RESULTS: In 30 and 40 PCF blocks, 3p S implants exhibited significantly higher IT values (90 and 80 Ncm, respectively) than 3p L (85 and 50 Ncm, respectively). Similarly, RT was significantly higher for 3p S implants in 30 and 40 PCF blocks (57 and 90 Ncm, respectively). However, there were no significant differences in RFA values, except for the 20 PCF block, where 3pS implants showed significantly lower values (63 ISQ) than 3p L implants (67 ISQ) in both the distal and mesial directions. CONCLUSIONS: These results demonstrated that the implant's length mainly influences the IT and RT values in the polyurethane blocks that mimic the mandibular region of the bone, resulting in higher values for the 3p S implants, while the RFA values remained unaffected. However, in the lowest density block simulating the maxillary bone, 3p L implants exhibited significantly higher ISQ values. CLINICAL RELEVANCE: Therefore, our data offer valuable insights into the biomechanical behavior of these implants, which could be clinically beneficial for enhancing surgical planning.


Assuntos
Implantes Dentários , Maxila , Poliuretanos , Análise de Frequência de Ressonância , Torque
2.
Biomedicines ; 11(11)2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-38002077

RESUMO

The issue of dental implant placement relative to the alveolar crest, whether in supracrestal, equicrestal, or subcrestal positions, remains highly controversial, leading to conflicting data in various studies. Three-dimensional (3D) Finite Element Analysis (FEA) can offer insights into the biomechanical aspects of dental implants and the surrounding bone. A 3D model of the jaw was generated using computed tomography (CT) scans, considering a cortical thickness of 1.5 mm. Subsequently, Morse cone implant-abutment connection implants were virtually positioned at the model's center, at equicrestal (0 mm) and subcrestal levels (-1 mm and -2 mm). The findings indicated the highest stress within the cortical bone around the equicrestally placed implant, the lowest stress in the -2 mm subcrestally placed implant, and intermediate stresses in the -1 mm subcrestally placed implant. In terms of clinical relevance, this study suggested that subcrestal placement of a Morse cone implant-abutment connection (ranging between -1 and -2 mm) could be recommended to reduce peri-implant bone resorption and achieve longer-term implant success.

3.
J Funct Biomater ; 14(9)2023 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-37754859

RESUMO

The design of the implant prosthesis-abutment complex appears crucial for shaping healthy and stable peri-implant soft tissues. The aim of the present animal study was to compare two implants with different healing abutment geometries: a concave design (TEST) and a straight one (CTRL). Transmission electron microscopy (TEM) was used to quantify the three-dimensional topography and morphological properties of collagen at nanoscale resolution. 2 swine were included in the experiment and 6 implants per animal were randomly placed in the left or right hemimandible in either the physiologically mature bone present between the lower canine and first premolar or in the mandibular premolar area, within tooth extraction sites. Each CTRL implant was positioned across from its respective TEST implant on the other side of the jaw. After 12 weeks of healing, 8 specimens (4 CTRL and 4 TEST) were retrieved and prepared for histological and TEM analysis. The results showed a significantly higher percentage of area covered by collagen bundles and average bundle size in TEST implants, as well as a significant decrease in the number of longitudinally oriented bundles with respect to CTRL implants, which is potentially due to the larger size of TEST bundles. These data suggest that a concave transmucosal abutment design serves as a scaffold, favoring the deposition and growth of a well-organized peri-implant collagen structure over the implant platform in the early healing phase, also promoting the convergence of collagen fibers toward the abutment collar.

4.
Biomimetics (Basel) ; 8(4)2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37622941

RESUMO

Extreme atrophy of the maxilla still poses challenges for clinicians. Some of the techniques used to address this issue can be complex, risky, expensive, and time consuming, often requiring skilled surgeons. While many commonly used techniques have achieved very high success rates, complications may arise in certain cases. In this context, the premaxillary device (PD) technique offers a simpler approach to reconstruct severely atrophic maxillae, aiming to avoid more complicated and risky surgical procedures. Finite element analysis (FEA) enables the evaluation of different aspects of dental implant biomechanics. Our results demonstrated that using a PD allows for an optimal distribution of stresses on the basal bone, avoiding tension peaks that can lead to bone resorption or implant failure. ANSYS® was used to perform localized finite element analysis (FEA), enabling a more precise examination of the peri-crestal area and the PD through an accurate mesh element reconstruction, which facilitated the mathematical solution of FEA. The most favorable biomechanical behavior was observed for materials such as titanium alloys, which helped to reduce stress levels on bone, implants, screws, and abutments. Additionally, stress values remained within the limits of basal bone and titanium alloy strengths. In conclusion, from a biomechanical point of view, PDs appear to be viable alternatives for rehabilitating severe atrophic maxillae.

5.
Materials (Basel) ; 16(14)2023 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-37512339

RESUMO

Combining tooth extraction and implant placement reduces the number of surgical procedures that a patient must undergo. Thus, the present study aimed to compare the stability of two types of conical implants (TAC and INTRALOCK) and another cylindrical one (CYROTH), inserted with a range of angulation of 15-20 degrees in low-density polyurethane blocks (10 and 20 pounds per cubic foot, PCF) with or without a cortical lamina (30 PCF), which potentially mimicked the post-extraction in vivo condition. For this purpose, a total of 120 polyurethane sites were prepared (10 for each implant and condition) and the Insertion Torque (IT), Removal Torque (RT), and Resonance Frequency Analysis (RFA) were measured, following a Three-Way analysis of variance followed by Tukey's post hoc test for the statistical analysis of data. The IT and RT values registered for all implant types were directly proportional to the polyurethane density. The highest IT was registered by INTRALOCK implants in the highest-density block (32.44 ± 3.28 Ncm). In contrast, the highest RFA, a well-known index of Implant Stability Quotient (ISQ), was shown by TAC implants in all clinical situations (up to 63 ISQ in the 20 PCF block without the cortical sheet), especially in lower-density blocks. Although more pre-clinical and clinical studies are required, these results show a better primary stability of TAC conical implants in all tested densities of this post-extraction model, with a higher ISQ, despite their IT.

6.
Int J Mol Sci ; 24(8)2023 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-37108387

RESUMO

Essential oils (EOs) are mixtures of volatile compounds belonging to several chemical classes derived from aromatic plants using different distillation techniques. Recent studies suggest that the consumption of Mediterranean plants, such as anise and laurel, contributes to improving the lipid and glycemic profile of patients with diabetes mellitus (DM). Hence, the aim of the present study was to investigate the potential anti-inflammatory effect of anise and laurel EOs (AEO and LEO) on endothelial cells isolated from the umbilical cord vein of females with gestational diabetes mellitus (GDM-HUVEC), which is a suitable in vitro model to reproduce the pro-inflammatory phenotype of a diabetic endothelium. For this purpose, the Gas Chromatographic/Mass Spectrometric (GC-MS) chemical profiles of AEO and LEO were first analyzed. Thus, GDM-HUVEC and related controls (C-HUVEC) were pre-treated for 24 h with AEO and LEO at 0.025% v/v, a concentration chosen among others (cell viability by MTT assay), and then stimulated with TNF-α (1 ng/mL). From the GC-MS analysis, trans-anethole (88.5%) and 1,8-cineole (53.9%) resulted as the major components of AEO and LEO, respectively. The results in C- and GDM-HUVEC showed that the treatment with both EOs significantly reduced: (i) the adhesion of the U937 monocyte to HUVEC; (ii) vascular adhesion molecule-1 (VCAM-1) protein and gene expression; (iii) Nuclear Factor-kappa B (NF-κB) p65 nuclear translocation. Taken together, these data suggest the anti-inflammatory efficacy of AEO and LEO in our in vitro model and lay the groundwork for further preclinical and clinical studies to study their potential use as supplements to mitigate vascular endothelial dysfunction associated with DM.


Assuntos
Diabetes Gestacional , Óleos Voláteis , Humanos , Gravidez , Feminino , Monócitos/metabolismo , Células Endoteliais/metabolismo , Diabetes Gestacional/tratamento farmacológico , Diabetes Gestacional/metabolismo , Óleos Voláteis/farmacologia , Óleos Voláteis/metabolismo , Células U937 , Adesão Celular , NF-kappa B/metabolismo , Cordão Umbilical/metabolismo , Molécula 1 de Adesão de Célula Vascular/metabolismo , Fator de Necrose Tumoral alfa/metabolismo , Molécula 1 de Adesão Intercelular/metabolismo
7.
Biomedicines ; 11(3)2023 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-36979765

RESUMO

Maintaining periodontal and peri-implant soft tissues health is crucial for the long-term health of teeth and dental implants. New biomedical strategies aimed at avoiding connective tissue alterations and related diseases (e.g., periodontitis and peri-implantitis) are constantly evolving. Among these, collagen-based medical products have proven to be safe and effective. Accordingly, the aim of the present study was to evaluate the effects of Dental SKIN BioRegulation (Guna S.p.a., Milan, Italy), a new injectable medical device composed of type I collagen of porcine origin, on primary cultures of human gingival fibroblasts (hGF). To this end, hGF were cultured on collagen-coated (COL, 100 µg/2 mL) or uncoated plates (CTRL) before evaluating cell viability (24 h, 48 h, 72 h, and 7 d), wound healing properties (3 h, 6 h, 12 h, 24 h, and 48 h), and the activation of mechanotransduction markers, such as FAK, YAP, and TAZ (48 h). The results proved a significant increase in cell viability at 48 h (p < 0.05) and wound closure at 24 h (p < 0.001) of hGF grown on COL, with an increasing trend at all time-points. Furthermore, COL significantly induced the expression of FAK and YAP/TAZ (p < 0.05), thereby promoting the activation of mechanotransduction signaling pathways. Overall, these data suggest that COL, acting as a mechanical bio-scaffold, could represent a useful treatment for gingival rejuvenation and may possibly help in the resolution of oral pathologies.

8.
Artigo em Inglês | MEDLINE | ID: mdl-36767949

RESUMO

Stabilization of dental implants in the sinus region with a bone height below 4 mm gen-erally requires a two-stage sinus floor elevation surgery. To improve this aspect, the aim of this retrospective study was to demonstrate the feasibility of performing a one-stage maxillary sinus augmentation using an innovative self-condensing implant design, even in case of a bone height close to 2 mm. Clinical and radiological outcomes from 54 patients (26 females; 28 males; 69 total implants positioned) were analyzed 3 years post-surgery. The three-dimensional grafts change was evaluated by Cone-Beam Computed Tomography (CBCT) before surgery (T0), immediately after surgery (T1), and 1-year post-surgery (T2). The sinus floor levels measured at the medial (M-W), middle (MD-W), and lateral (L-W) walls reported: M-W of 1.9 ± 2.4 mm (T1) and 1.7 ± 2.6 mm (T2); MD-W of -0.1 ± 2.7 mm (T1) and 0.7 ± 2.4 mm (T2); L-W of 3.1 ± 3.0 mm (T1) and 3.1 ± 3.0 mm (T2); besides a bone crest height (C-F) of 4.6 ± 2.0 mm (T1) and 12.1 ± 1.4 mm (T2). Moreover, after 3 years only 1 implant was lost, and so an implant survival rate of 98.55% was recorded. In conclusion, these results suggest the efficacy of using this implant design for a one-stage sinus lift approach, not only in terms of increased implant survival rate and decreased marginal bone loss, but also for its potential applicability in case of reduced bone height.


Assuntos
Levantamento do Assoalho do Seio Maxilar , Masculino , Feminino , Humanos , Seguimentos , Estudos Retrospectivos , Levantamento do Assoalho do Seio Maxilar/métodos , Tomografia Computadorizada de Feixe Cônico , Seio Maxilar/diagnóstico por imagem , Seio Maxilar/cirurgia , Resultado do Tratamento
9.
J Funct Biomater ; 13(3)2022 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-35997459

RESUMO

Over the years, several bone regeneration procedures have been proposed using natural (autografts, allografts, and xenografts) and synthetic (i.e., metals, ceramics, and polymers) bone grafts. In particular, numerous in vitro and human and animal in vivo studies have been focused on the discovery of innovative and suitable biomaterials for oral and maxillofacial applications in the treatment of severely atrophied jaws. On this basis, the main objective of the present narrative review was to investigate the efficacy of innovative collagenated porcine bone grafts (OsteoBiol®, Tecnoss®, Giaveno, Italy), designed to be as similar as possible to the autologous bone, in several bone regeneration procedures. The scientific publications were screened by means of electronic databases, such as PubMed, Scopus, and Embase, finally selecting only papers that dealt with bone substitutes and scaffolds for bone and soft tissue regeneration. A total of 201 papers have been detected, including in vitro, in vivo, and clinical studies. The effectiveness of over 20 years of translational research demonstrated that these specific porcine bone substitutes are safe and able to improve the biological response and the predictability of the regenerative protocols for the treatment of alveolar and maxillofacial defects.

10.
J Funct Biomater ; 14(1)2022 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-36662057

RESUMO

Short implants were introduced to reduce morbidity, treatment duration, and complex bone regeneration interventions in atrophic jaws and to improve patient-reported outcomes. This study aimed to determine the insertion torque (IT), removal torque (RT), and resonance frequency analysis (RFA) values of ultrashort (3 mm length), short (7 mm length), and standard implants (10 mm length) inserted in 1-, 2-, 3-, and 4-mm thickness polyurethane sheets with densities of 10, 20, and 30 pounds per cubic foot (PCF). Standard-length implants were the gold standard (control). Overall, short-length implant IT values were higher or similar to the control in most experimental conditions. Those inserted into a 3 mm/30 PCF lamina showed the highest IT values, whereas 5 mm diameter ultrashort-length implants inserted into 2 and 3 mm/20 PCF laminas were higher than other implants. RT values followed the same trend and RFA values were more appreciable in short- and standard-length implants in all the scenarios. However, ultrashort-length implants reached a primary stability comparable to that of standard implants in lower thicknesses. In conclusion, although further studies are needed to corroborate this in vitro model with preclinical and clinical studies, our data shed light on short- and ultrashort-length implants geometries to a potential application in critical atrophy of the posterior jaws.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA