1.
Eur J Cardiothorac Surg ; 52(4): 818-819, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-29156010

RESUMO

Transcatheter valve procedures are wide-spreading techniques for the treatment of heart valves pathologies. In case of implantation failure, the transcatheter device often needs to be removed. This procedure, which can alter the biological structure integrity, can limit the option available for the subsequent traditional surgery. One of the most popular devices for transcatheter mitral valve repair is the MitraClip system. In this work, we describe 2 different techniques for the surgical removal of MitraClip. These techniques aim to preserve the valve leaflets integrity, to allow for subsequent mitral valve surgical repair.


Assuntos
Remoção de Dispositivo/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Mitral/cirurgia , Cateterismo Cardíaco/instrumentação , Falha de Equipamento , Humanos , Insuficiência da Valva Mitral/cirurgia
2.
Ann Biomed Eng ; 45(10): 2324-2334, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28721493

RESUMO

Functional mitral regurgitation (FMR) is a complex pathology involving valvular and subvalvular structures reconfiguration, and its treatment is considered challenging. There is a lack of experimental models allowing for reliable preclinical FMR treatments' evaluation in a realistic setting. A novel approach to simulate FMR was developed and incorporated into an ex vivo passive beating heart platform. FMR was obtained by dilating the mitral annulus (MA) mainly in the antero-posterior direction and displacing the papillary muscles (PMs) apically and laterally by ad hoc designed and 3D printed dilation and displacing devices. It caused hemodynamic and valve morphology alterations. Isolated MA dilation (MAD) led to significantly increased antero-posterior distance (A-P) and decreased coaptation height (CH), tenting area (TA) and systolic leaflets angulation, resembling clinically recognized type I of mitral regurgitation with normal leaflet motion. Whereas concomitant MAD with PM displacement caused an increase in A-P, TA, CH. This geometrical configuration replicated typical determinants of type IIIb lesion with restricted leaflet motion. The proposed methods provided a realistic and repeatable ex vivo FMR model featuring two lesions clinically associated with the pathology. It bears a promise to be successfully utilized in preclinical studies, clinical training and medical education.


Assuntos
Coração/fisiopatologia , Insuficiência da Valva Mitral/fisiopatologia , Modelos Cardiovasculares , Animais , Humanos , Insuficiência da Valva Mitral/patologia , Suínos
3.
J Biomech ; 50: 83-92, 2017 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-27863743

RESUMO

Mitraclip® implantation is widely used as a valid alternative to conventional open-chest surgery in high-risk patients with severe mitral valve (MV) regurgitation. Although effective in reducing mitral regurgitation (MR) in the majority of cases, the clip implantation produces a double-orifice area that can result in altered MV biomechanics, particularly in term of hemodynamics and mechanical stress distribution on the leaflets. In this scenario, we combined the consistency of in vitro experimental platforms with the versatility of numerical simulations to investigate clip impact on MV functioning. The fluid dynamic determinants of the procedure were experimentally investigated under different working conditions (from 40bpm to 100bpm of simulated heart rate) on six swine hearts; subsequently, fluid dynamic data served as realistic boundary conditions in a computational framework able to quantitatively assess the post-procedural MV biomechanics. The finite element model of a human mitral valve featuring an isolated posterior leaflet prolapse was reconstructed from cardiac magnetic resonance. A complete as well as a marginal, sub-optimal grasping of the leaflets were finally simulated. The clipping procedure resulted in a properly coapting valve from the geometrical perspective in all the simulated configurations. Symmetrical complete grasping resulted in symmetrical distribution of the mechanical stress, while uncomplete asymmetrical grasping resulted in higher stress distribution, particularly on the prolapsing leaflet. This work pinpointed that the mechanical stress distribution following the clipping procedure is dependent on the cardiac hemodynamics and has a correlation with the proper execution of the grasping procedure, requiring accurate evaluation prior to clip delivery.


Assuntos
Prolapso da Valva Mitral/fisiopatologia , Valva Mitral/fisiopatologia , Animais , Débito Cardíaco , Simulação por Computador , Análise de Elementos Finitos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Modelos Cardiovasculares , Sus scrofa
4.
J Am Coll Cardiol ; 68(10): 1024-33, 2016 09 06.
Artigo em Inglês | MEDLINE | ID: mdl-27585507

RESUMO

BACKGROUND: Although associated with left heart pathologies, functional tricuspid regurgitation (FTR) is often left untreated during left heart surgery. Hence, owing to its degenerative character, reoperation is often needed, encompassing an impressive (25% to 35%) mortality rate. Thus transcatheter approaches to FTR are raising great interest. OBJECTIVES: The authors evaluated the post-treatment effectiveness of the edge-to-edge technique using the percutaneous mitral valve repair device in an ex vivo pulsatile model of FTR. METHODS: The devices were implanted in 11 porcine hearts simulating FTR. In each heart, single-clip treatments involved grasping leaflet pairs in the medial or commissural position (6 combinations). Two-clip treatments were then performed considering all possible 15 combinations of leaflet pairs and medial/commissural grasping. Cardiac output, mean pulmonary pressure, and mean diastolic valve pressure gradient were evaluated in physiological and simulated pathological conditions (FTR), and post-treatments. RESULTS: Grasping the septal and anterior leaflets allowed for the best post-procedural outcome, ensuring a complete re-establishment of physiological-like hemodynamics. Septal and posterior grasping induced a significant recovery from FTR, although less marked. Conversely, grasping the anterior and posterior leaflets did not reduce FTR, and was detrimental in some specific cases. CONCLUSIONS: This experimental work demonstrated that the transcatheter edge-to-edge repair technique is a feasible approach for FTR. The study investigated this approach to develop a selective, specific structural intervention methodology for treating FTR, considering the several biomechanical factors that alter proper functionality of valvular substructures. These results can be used to guide the development of edge-to-edge repair techniques in treatment of FTR.


Assuntos
Insuficiência da Valva Tricúspide/cirurgia , Animais , Cateterismo Cardíaco/instrumentação , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos Cardíacos/métodos , Modelos Animais de Doenças , Técnicas In Vitro , Suínos
5.
Ann Ist Super Sanita ; 43(1): 89-100, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17536159

RESUMO

The implantation of coronary stents is a relevant part of interventional procedures for percutaneous revascularization. The wide acceptance of coronary stenting was based on the results of two highly significant trials which have shown the superiority of stenting over balloon angioplasty in terms of reduction of angiographic restenosis and need for repeated intervention in focal lesions and large coronary arteries. Since then, the growing use of stent market was impressive. A rapidly increasing number of different stent type with different material and designs has been introduced in the market both for bare metal stent and drug eluting stent. This review will summarize the different components of stent design that are important in term of biological response of the arterial wall and clinical outcome. In addition, new stent platforms, mainly represented by the biodegradable stent will be shortly reviewed since it may provide in the near future a more "physiological" answer to stent implantation, reducing vascular injury and accelerating vessel healing with consequent improving in clinical outcome.


Assuntos
Estenose Coronária/terapia , Stents , Implantes Absorvíveis , Angioplastia Coronária com Balão , Ensaios Clínicos como Assunto , Materiais Revestidos Biocompatíveis , Implantes de Medicamento , Desenho de Equipamento , Humanos , Estudos Multicêntricos como Assunto , Paclitaxel/administração & dosagem , Sirolimo/administração & dosagem , Stents/efeitos adversos , Stents/classificação , Resultado do Tratamento