Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Bull Math Biol ; 85(9): 83, 2023 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-37574503

RESUMO

We present a new approach for relating nucleic-acid content to fluorescence in a real-time Polymerase Chain Reaction (PCR) assay. By coupling a two-type branching process for PCR with a fluorescence analog of Beer's Law, the approach reduces bias and quantifies uncertainty in fluorescence. As the two-type branching process distinguishes between complementary strands of DNA, it allows for a stoichiometric description of reactions between fluorescent probes and DNA and can capture the initial conditions encountered in assays targeting RNA. Analysis of the expected copy-number identifies additional dynamics that occur at short times (or, equivalently, low cycle numbers), while investigation of the variance reveals the contributions from liquid volume transfer, imperfect amplification, and strand-specific amplification (i.e., if one strand is synthesized more efficiently than its complement). Linking the branching process to fluorescence by the Beer's Law analog allows for an a priori description of background fluorescence. It also enables uncertainty quantification (UQ) in fluorescence which, in turn, leads to analytical relationships between amplification efficiency (probability) and limit of detection. This work sets the stage for UQ-PCR, where both the input copy-number and its uncertainty are quantified from fluorescence kinetics.


Assuntos
Conceitos Matemáticos , Modelos Biológicos , Incerteza , Reação em Cadeia da Polimerase , DNA/genética
2.
Biologicals ; 82: 101680, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37178559

RESUMO

In response to the COVID-19 pandemic, the National Institute of Standards and Technology released a synthetic RNA material for SARS-CoV-2 in June 2020. The goal was to rapidly produce a material to support molecular diagnostic testing applications. This material, referred to as Research Grade Test Material 10169, was shipped free of charge to laboratories across the globe to provide a non-hazardous material for assay development and assay calibration. The material consisted of two unique regions of the SARS-CoV-2 genome approximately 4 kb nucleotides in length. The concentration of each synthetic fragment was measured using RT-dPCR methods and confirmed to be compatible with RT-qPCR methods. In this report, the preparation, stability, and limitations of this material are described.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Pandemias , Técnicas de Diagnóstico Molecular/métodos , RNA Viral/genética , Sensibilidade e Especificidade , Teste para COVID-19
3.
Nucleic Acids Res ; 49(3): 1517-1531, 2021 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-33450006

RESUMO

The maternal mode of mitochondrial DNA (mtDNA) inheritance is central to human genetics. Recently, evidence for bi-parental inheritance of mtDNA was claimed for individuals of three pedigrees that suffered mitochondrial disorders. We sequenced mtDNA using both direct Sanger and Massively Parallel Sequencing in several tissues of eleven maternally related and other affiliated healthy individuals of a family pedigree and observed mixed mitotypes in eight individuals. Cells without nuclear DNA, i.e. thrombocytes and hair shafts, only showed the mitotype of haplogroup (hg) V. Skin biopsies were prepared to generate ρ° cells void of mtDNA, sequencing of which resulted in a hg U4c1 mitotype. The position of the Mega-NUMT sequence was determined by fluorescence in situ hybridization and two different quantitative PCR assays were used to determine the number of contributing mtDNA copies. Thus, evidence for the presence of repetitive, full mitogenome Mega-NUMTs matching haplogroup U4c1 in various tissues of eight maternally related individuals was provided. Multi-copy Mega-NUMTs mimic mixtures of mtDNA that cannot be experimentally avoided and thus may appear in diverse fields of mtDNA research and diagnostics. We demonstrate that hair shaft mtDNA sequencing provides a simple but reliable approach to exclude NUMTs as source of misleading results.


Assuntos
DNA Mitocondrial , Genoma Humano , Núcleo Celular/genética , Variações do Número de Cópias de DNA , Feminino , Humanos , Masculino , Linhagem , Análise de Sequência de DNA
4.
Anal Bioanal Chem ; 412(28): 7977-7988, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32951064

RESUMO

Motivated by the current COVID-19 health crisis, we consider data analysis for quantitative polymerase chain-reaction (qPCR) measurements. We derive a theoretical result specifying the conditions under which all qPCR amplification curves (including their plateau phases) are identical up to an affine transformation, i.e. a multiplicative factor and horizontal shift. We use this result to develop a data analysis procedure for determining when an amplification curve exhibits characteristics of a true signal. The main idea behind this approach is to invoke a criterion based on constrained optimization that assesses when a measurement signal can be mapped to a master reference curve. We demonstrate that this approach: (i) can decrease the fluorescence detection threshold by up to a decade; and (ii) simultaneously improve confidence in interpretations of late-cycle amplification curves. Moreover, we demonstrate that the master curve is transferable reference data that can harmonize analyses between different labs and across several years. Application to reverse-transcriptase qPCR measurements of a SARS-CoV-2 RNA construct points to the usefulness of this approach for improving confidence and reducing limits of detection in diagnostic testing of emerging diseases. Graphical Abstract Left: a collection of qPCR amplification curves. Right: Example of data collapse after affine transformation.


Assuntos
Algoritmos , Betacoronavirus/genética , Infecções por Coronavirus/virologia , Pneumonia Viral/virologia , RNA Viral/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Betacoronavirus/isolamento & purificação , COVID-19 , Infecções por Coronavirus/diagnóstico , Humanos , Pandemias , Pneumonia Viral/diagnóstico , RNA Viral/análise , Reação em Cadeia da Polimerase em Tempo Real/métodos , SARS-CoV-2
5.
J Forensic Sci ; 65(3): 953-959, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31985834

RESUMO

Three commercially available integrated rapid DNA instruments were tested as a part of a rapid DNA maturity assessment in July of 2018. The assessment was conducted with sets of blinded single-source reference samples provided to participants for testing on the individual rapid platforms within their laboratories. The data were returned to the National Institute of Standards and Technology (NIST) for review and analysis. Both FBI-defined automated review (Rapid DNA Analysis) and manual review (Modified Rapid DNA Analysis) of the datasets were conducted to assess the success of genotyping the 20 Combined DNA Index System (CODIS) core STR loci and full profiles generated by the instruments. Genotype results from the multiple platforms, participating laboratories, and STR typing chemistries were combined into a single analysis. The Rapid DNA Analysis resulted in a success rate of 80% for full profiles (85% for the 20 CODIS core loci) with automated analysis. Modified Rapid DNA Analysis resulted in a success rate of 90% for both the CODIS 20 core loci and full profiles (all attempted loci per chemistry). An analysis of the peak height ratios demonstrated that 95% of all heterozygous alleles were above 59% heterozygote balance. For base-pair sizing precision, the precision was below the standard 0.5 bp deviation for both the ANDE 6C System and the RapidHIT 200.


Assuntos
Impressões Digitais de DNA/instrumentação , Impressões Digitais de DNA/normas , DNA/isolamento & purificação , Bases de Dados de Ácidos Nucleicos , Genótipo , Heterozigoto , Humanos , Repetições de Microssatélites , Mucosa Bucal/química , Controle de Qualidade
6.
Forensic Sci Int Genet ; 40: 120-130, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30818156

RESUMO

A developmental validation was performed to demonstrate reliability, reproducibility and robustness of the ANDE System with the FlexPlex assay, including an integrated Expert System, across a number of laboratories and buccal sample variations. Previously, the related DNAscan™/ANDE 4C Rapid DNA System using the PowerPlex®16 assay and integrated Expert System Software received NDIS approval in March 2016. The enhanced ANDE instrument, referred to as ANDE 6C, and the accompanying 6-dye, 27-locus STR assay, referred to as FlexPlex, have been developed to be compatible with all widely used global loci, including the expanded set of the CODIS core 20 loci. Six forensic and research laboratories participated in the FlexPlex Rapid DNA developmental validation experiments, testing a total of 2045 swabs, including those obtained from 1387 unique individuals. The goal of this extensive and comprehensive validation was to thoroughly evaluate and document the ANDE System and its internal Expert System to reliably genotype reference buccal swab samples in a manner compliant with the FBI's Quality Assurance Standards and the NDIS Operational Procedures. The ANDE System, including automated Expert System analysis, generated reproducible and concordant results for buccal swabs when testing various instruments at different laboratories by a number of different operators. When testing a number of non-human DNAs, including oral bacteria, the ANDE System and FlexPlex assay demonstrated limited cross-reactivity. Potential PCR inhibitors were evaluated as part of the validation and no inhibition was detected. Reproducible and concordant profiles were generated from buccal swab samples collected with a limit of detection appropriate for buccal swab collections from arrestees. The precision and resolution of the System met industry standards for detection of microvariants and single base resolution. The integrated Expert System appropriately demonstrated the ability to correctly pass or fail profiles for CODIS upload without human review. During this comprehensive developmental validation, the ANDE System successfully interpreted over 2000 samples tested with over 99.99% concordant alleles. The data package described herein led to the ANDE System with the FlexPlex assay receiving NDIS approval in June 2018.


Assuntos
Impressões Digitais de DNA/instrumentação , Bases de Dados de Ácidos Nucleicos , Repetições de Microssatélites , Manejo de Espécimes/instrumentação , Animais , Humanos , Mucosa Bucal/química , Reação em Cadeia da Polimerase , Prisioneiros , Reprodutibilidade dos Testes , Especificidade da Espécie
7.
Anal Bioanal Chem ; 410(10): 2569-2583, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29504082

RESUMO

Blood samples are widely used for PCR-based DNA analysis in fields such as diagnosis of infectious diseases, cancer diagnostics, and forensic genetics. In this study, the mechanisms behind blood-induced PCR inhibition were evaluated by use of whole blood as well as known PCR-inhibitory molecules in both digital PCR and real-time PCR. Also, electrophoretic mobility shift assay was applied to investigate interactions between inhibitory proteins and DNA, and isothermal titration calorimetry was used to directly measure effects on DNA polymerase activity. Whole blood caused a decrease in the number of positive digital PCR reactions, lowered amplification efficiency, and caused severe quenching of the fluorescence of the passive reference dye 6-carboxy-X-rhodamine as well as the double-stranded DNA binding dye EvaGreen. Immunoglobulin G was found to bind to single-stranded genomic DNA, leading to increased quantification cycle values. Hemoglobin affected the DNA polymerase activity and thus lowered the amplification efficiency. Hemoglobin and hematin were shown to be the molecules in blood responsible for the fluorescence quenching. In conclusion, hemoglobin and immunoglobulin G are the two major PCR inhibitors in blood, where the first affects amplification through a direct effect on the DNA polymerase activity and quenches the fluorescence of free dye molecules, and the latter binds to single-stranded genomic DNA, hindering DNA polymerization in the first few PCR cycles. Graphical abstract PCR inhibition mechanisms of hemoglobin and immunoglobulin G (IgG). Cq quantification cycle, dsDNA double-stranded DNA, ssDNA single-stranded DNA.


Assuntos
DNA/sangue , Hemoglobinas/metabolismo , Imunoglobulina G/metabolismo , Reação em Cadeia da Polimerase/métodos , Proteínas de Bactérias/genética , DNA/genética , DNA/metabolismo , DNA Bacteriano/sangue , DNA Bacteriano/genética , DNA Bacteriano/metabolismo , DNA Polimerase Dirigida por DNA/metabolismo , Humanos , Proteínas de Ligação a Retinoblastoma/genética , Salmonella typhimurium/genética , Ubiquitina-Proteína Ligases/genética
8.
Anal Bioanal Chem ; 410(12): 2879-2887, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29556737

RESUMO

The highly multiplexed polymerase chain reaction (PCR) assays used for forensic human identification perform best when used with an accurately determined quantity of input DNA. To help ensure the reliable performance of these assays, we are developing a certified reference material (CRM) for calibrating human genomic DNA working standards. To enable sharing information over time and place, CRMs must provide accurate and stable values that are metrologically traceable to a common reference. We have shown that droplet digital PCR (ddPCR) limiting dilution end-point measurements of the concentration of DNA copies per volume of sample can be traceably linked to the International System of Units (SI). Unlike values assigned using conventional relationships between ultraviolet absorbance and DNA mass concentration, entity-based ddPCR measurements are expected to be stable over time. However, the forensic community expects DNA quantity to be stated in terms of mass concentration rather than entity concentration. The transformation can be accomplished given SI-traceable values and uncertainties for the number of nucleotide bases per human haploid genome equivalent (HHGE) and the average molar mass of a nucleotide monomer in the DNA polymer. This report presents the considerations required to establish the metrological traceability of ddPCR-based mass concentration estimates of human nuclear DNA. Graphical abstract The roots of metrological traceability for human nuclear DNA mass concentration results. Values for the factors in blue must be established experimentally. Values for the factors in red have been established from authoritative source materials. HHGE stands for "haploid human genome equivalent"; there are two HHGE per diploid human genome.


Assuntos
DNA/genética , Reação em Cadeia da Polimerase/métodos , Algoritmos , DNA/análise , Dosagem de Genes , Genoma Humano , Haploidia , Humanos
9.
PLoS One ; 12(11): e0188085, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29145448

RESUMO

Droplet digital PCR (ddPCR) is being advocated as a reference method to measure rare genomic targets. It has consistently been proven to be more sensitive and direct at discerning copy numbers of DNA than other quantitative methods. However, one of the largest obstacles to measuring microRNA (miRNA) using ddPCR is that reverse transcription efficiency depends upon the target, meaning small RNA nucleotide composition directly effects primer specificity in a manner that prevents traditional quantitation optimization strategies. Additionally, the use of reagents that are optimized for miRNA measurements using quantitative real-time PCR (qRT-PCR) appear to either cause false positive or false negative detection of certain targets when used with traditional ddPCR quantification methods. False readings are often related to using inadequate enzymes, primers and probes. Given that two-step miRNA quantification using ddPCR relies solely on reverse transcription and uses proprietary reagents previously optimized only for qRT-PCR, these barriers are substantial. Therefore, here we outline essential controls, optimization techniques, and an efficacy model to improve the quality of ddPCR miRNA measurements. We have applied two-step principles used for miRNA qRT-PCR measurements and leveraged the use of synthetic miRNA targets to evaluate ddPCR following cDNA synthesis with four different commercial kits. We have identified inefficiencies and limitations as well as proposed ways to circumvent identified obstacles. Lastly, we show that we can apply these criteria to a model system to confidently quantify miRNA copy number. Our measurement technique is a novel way to quantify specific miRNA copy number in a single sample, without using standard curves for individual experiments. Our methodology can be used for validation and control measurements, as well as a diagnostic technique that allows scientists, technicians, clinicians, and regulators to base miRNA measures on a single unit of measurement rather than a ratio of values.


Assuntos
MicroRNAs/análise , Reação em Cadeia da Polimerase em Tempo Real/métodos , Linhagem Celular , DNA Complementar/biossíntese , Humanos , Temperatura
10.
Anal Chem ; 89(3): 1642-1649, 2017 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-28118703

RESUMO

Digital PCR (dPCR) enables absolute quantification of nucleic acids by partitioning of the sample into hundreds or thousands of minute reactions. By assuming a Poisson distribution for the number of DNA fragments present in each chamber, the DNA concentration is determined without the need for a standard curve. However, when analyzing nucleic acids from complex matrixes such as soil and blood, the dPCR quantification can be biased due to the presence of inhibitory compounds. In this study, we evaluated the impact of varying the DNA polymerase in chamber-based dPCR for both pure and impure samples using the common PCR inhibitor humic acid (HA) as a model. We compared the TaqMan Universal PCR Master Mix with two alternative DNA polymerases: ExTaq HS and Immolase. By using Bayesian modeling, we show that there is no difference among the tested DNA polymerases in terms of accuracy of absolute quantification for pure template samples, i.e., without HA present. For samples containing HA, there were great differences in performance: the TaqMan Universal PCR Master Mix failed to correctly quantify DNA with more than 13 pg/nL HA, whereas Immolase (1 U) could handle up to 375 pg/nL HA. Furthermore, we found that BSA had a moderate positive effect for the TaqMan Universal PCR Master Mix, enabling accurate quantification for 25 pg/nL HA. Increasing the amount of DNA polymerase from 1 to 5 U had a strong effect for ExTaq HS, elevating HA-tolerance four times. We also show that the average Cq values of positive reactions may be used as a measure of inhibition effects, e.g., to determine whether or not a dPCR quantification result is reliable. The statistical models developed to objectively analyze the data may also be applied in quality control. We conclude that the choice of DNA polymerase in dPCR is crucial for the accuracy of quantification when analyzing challenging samples.


Assuntos
DNA Polimerase Dirigida por DNA/metabolismo , DNA/metabolismo , Reação em Cadeia da Polimerase , Animais , Teorema de Bayes , Bovinos , Corantes Fluorescentes/química , Substâncias Húmicas/análise , Soroalbumina Bovina/química , Espectrometria de Fluorescência
11.
ALTEX ; 34(2): 201-218, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27684074

RESUMO

Development of reliable cell-based nanotoxicology assays is important for evaluation of potentially hazardous engineered nanomaterials. Challenges to producing a reliable assay protocol include working with nanoparticle dispersions and living cell lines, and the potential for nano-related interference effects. Here we demonstrate the use of a 96-well plate design with several measurement controls and an interlaboratory comparison study involving five laboratories to characterize the robustness of a nanocytotoxicity MTS cell viability assay based on the A549 cell line. The consensus EC50 values were 22.1 mg/L (95% confidence intervals 16.9 mg/L to 27.2 mg/L) and 52.6 mg/L (44.1 mg/L to 62.6 mg/L) for positively charged polystyrene nanoparticles for the serum-free and serum conditions, respectively, and 49.7 µmol/L (47.5 µmol/L to 51.5 µmol/L) and 77.0 µmol/L (54.3 µmol/L to 99.4 µmol/L) for positive chemical control cadmium sulfate for the serum-free and serum conditions, respectively. Results from the measurement controls can be used to evaluate the sources of variability and their relative magnitudes within and between laboratories. This information revealed steps of the protocol that may need to be modified to improve the overall robustness and precision. The results suggest that protocol details such as cell line ID, media exchange, cell handling, and nanoparticle dispersion are critical to ensure protocol robustness and comparability of nanocytotoxicity assay results. The combination of system control measurements and interlaboratory comparison data yielded insights that would not have been available by either approach by itself.


Assuntos
Substâncias Perigosas/toxicidade , Laboratórios/estatística & dados numéricos , Nanopartículas/toxicidade , Poliestirenos/toxicidade , Testes de Toxicidade/estatística & dados numéricos , Células A549 , Humanos , Laboratórios/normas , Reprodutibilidade dos Testes , Testes de Toxicidade/normas
12.
Forensic Sci Int Genet ; 25: 145-156, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27606570

RESUMO

Since the implementation of forensic DNA typing in labs more than 20 years ago, the analysis procedures and data interpretation have always been conducted in a laboratory by highly trained and qualified scientific personnel. Rapid DNA technology has the potential to expand testing capabilities within forensic laboratories and to allow forensic STR analysis to be performed outside the physical boundaries of the traditional laboratory. The developmental validation of the DNAscan/ANDE Rapid DNA Analysis System was completed using a BioChipSet™ Cassette consumable designed for high DNA content samples, such as single source buccal swabs. A total of eight laboratories participated in the testing which totaled over 2300 swabs, and included nearly 1400 unique individuals. The goal of this extensive study was to obtain, document, analyze, and assess DNAscan and its internal Expert System to reliably genotype reference samples in a manner compliant with the FBI's Quality Assurance Standards (QAS) and the NDIS Operational Procedures. The DNAscan System provided high quality, concordant results for reference buccal swabs, including automated data analysis with an integrated Expert System. Seven external laboratories and NetBio, the developer of the technology, participated in the validation testing demonstrating the reproducibility and reliability of the system and its successful use in a variety of settings by numerous operators. The DNAscan System demonstrated limited cross reactivity with other species, was resilient in the presence of numerous inhibitors, and provided reproducible results for both buccal and purified DNA samples with sensitivity at a level appropriate for buccal swabs. The precision and resolution of the system met industry standards for detection of micro-variants and displayed single base resolution. PCR-based studies provided confidence that the system was robust and that the amplification reaction had been optimized to provide high quality results. The DNAscan integrated Expert System was examined as part of the Developmental Validation and successfully interpreted the over 2000 samples tested with over 99.998% concordant alleles. The system appropriately flagged samples for human review and failed both mixed samples and samples with insufficient genetic information. These results demonstrated the integrated Expert System makes correct allele calls without human intervention.


Assuntos
Automação , Impressões Digitais de DNA/instrumentação , Repetições de Microssatélites , Animais , Bases de Dados de Ácidos Nucleicos , Sistemas Inteligentes , Humanos , Armazenamento e Recuperação da Informação , Mucosa Bucal/química , Reprodutibilidade dos Testes , Saliva/química , Especificidade da Espécie
13.
Forensic Sci Int Genet ; 23: 166-177, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27206225

RESUMO

Quantification of the total amount of human DNA isolated from a forensic evidence item is crucial for DNA normalization prior to short tandem repeat (STR) DNA analysis and a federal quality assurance standard requirement. Previous commercial quantification methods determine the total human DNA and total human male DNA concentrations, but provide limited information about the condition of the DNA sample. The PowerQuant(®) System includes targets for quantification of total human and total human male DNA as well as targets for evaluating whether the human DNA is degraded and/or PCR inhibitors are present in the sample. A developmental validation of the PowerQuant(®) System was completed, following SWGDAM Validation Guidelines, to evaluate the assay's specificity, sensitivity, precision and accuracy, as well as the ability to detect degraded DNA or PCR inhibitors. In addition to the total human DNA and total human male DNA concentrations in a sample, data from the degradation target and internal PCR control (IPC) provide a forensic DNA analyst meaningful information about the quality of the isolated human DNA and the presence of PCR inhibitors in the sample that can be used to determine the most effective workflow and assist downstream interpretation.


Assuntos
Impressões Digitais de DNA , DNA/análise , Repetições de Microssatélites , Reação em Cadeia da Polimerase/instrumentação , Animais , Cromossomos Humanos Y , Degradação Necrótica do DNA , Humanos , Masculino , Grupos Raciais/genética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Especificidade da Espécie
14.
Anal Chem ; 88(4): 2132-9, 2016 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-26751276

RESUMO

Polymerase chain reaction (PCR) multiplexed assays perform best when the input quantity of template DNA is controlled to within about a factor of √2. To help ensure that PCR assays yield consistent results over time and place, results from methods used to determine DNA quantity need to be metrologically traceable to a common reference. Many DNA quantitation systems can be accurately calibrated with solutions of DNA in aqueous buffer. Since they do not require external calibration, end-point limiting dilution technologies, collectively termed "digital PCR (dPCR)", have been proposed as suitable for value assigning such DNA calibrants. The performance characteristics of several commercially available dPCR systems have recently been documented using plasmid, viral, or fragmented genomic DNA; dPCR performance with more complex materials, such as human genomic DNA, has been less studied. With the goal of providing a human genomic reference material traceably certified for mass concentration, we are investigating the measurement characteristics of several dPCR systems. We here report results of measurements from multiple PCR assays, on four human genomic DNAs treated with four endonuclease restriction enzymes using both chamber and droplet dPCR platforms. We conclude that dPCR does not estimate the absolute number of PCR targets in a given volume but rather the number of accessible and amplifiable targets. While enzymatic restriction of human genomic DNA increases accessibility for some assays, in well-optimized PCR assays it can reduce the number of amplifiable targets and increase assay variability relative to uncut sample.


Assuntos
DNA/análise , Genoma Humano , Reação em Cadeia da Polimerase , DNA/metabolismo , Primers do DNA/metabolismo , Enzimas de Restrição do DNA/metabolismo , Humanos
15.
Anal Bioanal Chem ; 407(30): 9061-9, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26438478

RESUMO

Polymerase chain reaction (PCR) end-point limiting dilution techniques, collectively termed "digital PCR (dPCR)", have been proposed as providing a potentially primary method for DNA quantification. We are evaluating several commercially available dPCR systems for use in certifying mass concentration in human genomic DNA reference materials. To better understand observed anomalies among results from chamber- and droplet-dPCR (cdPCR and ddPCR) systems, we have developed a graphical tool for evaluating and documenting the performance of PCR assays in real-time cdPCR systems: the ogive plot, the cumulative distribution of crossing threshold values. The ogive structure appears to embed information about early amplification events. We have successfully simulated ogives observed with different assays and reaction conditions using a four-stage amplification model parameterized by the probability of creating an intact 1) first generation "long" amplicon of indeterminate length from an original DNA target, 2) second generation defined-length amplicon from a long amplicon, and 3) defined-length amplicon from another defined-length amplicon. We are using insights from this model to optimize dPCR assay design and reaction conditions and to help validate assays proposed for use in value-assigning DNA reference materials.


Assuntos
DNA/genética , Reação em Cadeia da Polimerase/instrumentação , Adulto , Humanos , Masculino , Reação em Cadeia da Polimerase/métodos
16.
Forensic Sci Int Genet ; 18: 90-9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25937291

RESUMO

Multiplex PCR with fluorescently labeled primers has been an essential method for the amplification of short tandem repeats used in human identify testing. Within the STR workflow of extraction, quantitation, amplification, separation, and detection, multiplex PCR is commonly identified as the bottleneck in the process. The time requirement of up to three hours to complete 28-30 cycles of multiplex PCR for STR genotyping is the greatest amount of time required for a single step within the process. The historical use of commercially available thermal cyclers and heat stable polymerases may have given the impression that large multiplex will always require long PCR cycling times to ensure that all of the varying sized targets (typically 100-400bp) can be amplified in a balanced manner throughout the multiplex. However, with the advent of improved polymerases and faster thermal cyclers the time required for the amplification of large STR multiplexes is no longer on the order of three hours, but as little as 14min. Faster amplification times can be performed while retaining the balance and integrity of large multiplex PCRs by implementation of alternate polymerases and thermal cyclers. With the reduction in PCR cycling times there has also been an impact on the development of integrated and microfluidics devices which employ the use of reduced or rapid thermal cycling protocols as part of their integration. Similarly, PCR inhibitor resistant polymerases can also reduce overall STR processing times for reference samples by eliminating the need for DNA extraction and purification that is additionally implemented within the development of integrated DNA typing devices.


Assuntos
Identificação Biométrica/métodos , Genética Forense/métodos , Repetições de Microssatélites , Reação em Cadeia da Polimerase Multiplex/métodos , Impressões Digitais de DNA/métodos , Genótipo , Humanos , Análise em Microsséries/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA