Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Molecules ; 29(10)2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38792043

RESUMO

Multiplex sampling, so far mainly used as a tool for S/N ratio improvement in spectroscopic applications and separation techniques, has been investigated here for its potential suitability for time-resolved monitoring where chromatograms of transient signals are recorded at intervals much shorter than the chromatographic runtime. Different designs of multiplex sample introduction were developed and utilized to analyze lithium-ion battery degradation products under normal or abuse conditions to achieve fast and efficient sample introduction. After comprehensive optimization, measurements were performed on two different GC systems, with either barrier discharge ionization detection (BID) or mass spectrometric detection (MS). Three different injector designs were examined, and modifications in the pertinent hardware components and operational conditions used. The shortest achievable sample introduction time was 50 ms with an interval of 6 s. Relative standard deviations were lower than 4% and 10% for the intra- and inter-day repeatability, respectively. The sample introduction system and column head pressure had to be carefully controlled, as this parameter most critically affects the amount of sample introduced and, thus, detector response. The newly developed sample introduction system was successfully used to monitor volatile degradation products of lithium-ion batteries and demonstrated concentration changes over the course of time of the degradation products (e.g., fluoroethane, acetaldehyde and ethane), as well as for solvents from the battery electrolyte like ethyl carbonate.

2.
Anal Chim Acta ; 1304: 342555, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38637039

RESUMO

BACKGROUND: Omics is used as an analytical tool to investigate wine authenticity issues. Aging authentication ensures that the wine has undergone the necessary maturation and developed its desired organoleptic characteristics. Considering that aged wines constitute valuable commodities, the development of advanced omics techniques that guarantee aging authenticity and prevent fraud is essential. RESULTS: Α solid phase microextraction Arrow method combined with comprehensive two-dimensional gas chromatography-mass spectrometry was developed to identify volatiles in red wines and investigate how aging affects their volatile fingerprint. The method was optimized by examining the critical parameters that affect the solid phase microextraction Arrow extraction (stirring rate, extraction time) process. Under optimized conditions, extraction took place within 45 min under stirring at 1000 rpm. In all, 24 monovarietal red wine samples belonging to the Xinomavro variety from Naoussa (Imathia regional unit of Macedonia, Greece) produced during four different vintage years (1998, 2005, 2008 and 2015) were analyzed. Overall, 237 volatile compounds were tentatively identified and were treated with chemometric tools. Four major groups, one for each vintage year were revealed using the Hierarchical Clustering Analysis. The first two Principal Components of Principal Component Analysis explained 86.1% of the total variance, showing appropriate grouping of the wine samples produced in the same crop year. A two-way orthogonal partial least square - discriminant analysis model was developed and successfully classified all the samples to the proper class according to the vintage age, establishing 17 volatile markers as the most important features responsible for the classification, with an explained total variance of 88.5%. The developed prediction model was validated and the analyzed samples were classified with 100% accuracy according to the vintage age, based on their volatile fingerprint. SIGNIFICANCE: The developed methodology in combination with chemometric techniques allows to trace back and confirm the vintage year, and is proposed as a novel authenticity tool which opens completely new and hitherto unexplored possibilities for wine authenticity testing and confirmation.


Assuntos
Compostos Orgânicos Voláteis , Vinho , Vinho/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Microextração em Fase Sólida/métodos , Quimiometria , Análise por Conglomerados , Compostos Orgânicos Voláteis/análise
3.
Sensors (Basel) ; 24(6)2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38544236

RESUMO

Caffeine is the most widely consumed stimulant and is the subject of significant ongoing research and discussions due to its impact on human health. The industry's need to comply with country-specific food and beverage regulations underscores the importance of monitoring caffeine levels in commercial products. In this study, we propose an alternative technique for caffeine analysis that relies on mid-infrared laser-based photothermal spectroscopy (PTS). PTS exploits the high-power output of the quantum cascade laser (QCL) sources to enhance the sensitivity of the mid-IR measurement. The laser-induced thermal gradient in the sample scales with the analytes' absorption coefficient and concentration, thus allowing for both qualitative and quantitative assessment. We evaluated the performance of our experimental PTS spectrometer, incorporating a tunable QCL and a Mach-Zehnder interferometer, for detecting caffeine in coffee, black tea, and an energy drink. We calibrated the setup with caffeine standards (0.1-2.5 mg mL-1) and we benchmarked the setup's capabilities against gas chromatography (GC) and Fourier-transform infrared (FTIR) spectroscopy. Quantitative results aligned with GC analysis, and limits of detection matched the research-grade FTIR spectrometer, indicating an excellent performance of our custom-made instrument. This method offers an alternative to established techniques, providing a platform for fast, sensitive, and non-destructive analysis without consumables as well as with high potential for miniaturization.


Assuntos
Bebidas , Cafeína , Humanos , Cafeína/análise , Espectrofotometria Infravermelho , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Bebidas/análise , Lasers Semicondutores
4.
Anal Bioanal Chem ; 416(8): 1787-1795, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38263493

RESUMO

This feature article discusses the enabling role of analytical chemistry in important fields of research and development such as life science, material sciences and environmental sciences. It comments on the often limited visibility of analytical sciences in the public perception and suggests ways to overcome this shortcoming and to create bigger impact.

5.
Talanta ; 269: 125445, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38039676

RESUMO

Cloud point extraction is an environmentally benign and simple separation/concentration procedure that can be regarded as an alternative to classical liquid-liquid extraction. In the current work, it was studied the compatibility of cloud point extraction followed by back-extraction in low volume of organic solvent with gas chromatography-mass spectrometry (GC-MS and GC-MS/MS). Triton X-100 was preferred than Triton X-114 as a surfactant to produce the clouding phenomenon and hexane or isooctane was found to be appropriate organic solvents which can be used at the back-extraction step. It was observed that ca. 0.09 % w/w Triton X-100 was co-extracted in the organic phase (hexane or isooctane) so further study was carried out to find out its effect on the GC-MS (GC-MS/MS) measurement when liquid samples are injected without any pre-cleaning to remove the surfactant. The chromatographic separation and the mass detection were not deteriorated by the concomitant Triton X-100 for analysis of several Organochlorine and Organophosphorus pesticides (alpha-HCH, beta-HCH, gamma-HCH, Pentachlorobenzene, Hexachlorobenzene, Chlorpyrifos, Chlorpyrifos-methyl, Aldrin, Endrin, Dieldrin, alpha-Endosulfan, Heptachlor, Heptachlor-endo-epoxide-A, o,p-DDD, p,p-DDD, o,p-DDE, p,p-DDE, o,p-DDT and p,p-DDT). The stability of the GC system when introducing surfactant was assessed as acceptable (typically the peak area RSD% for 20 consecutive injections were below 5 %). Under the developed vaporization conditions using PTV or PSS injectors it can be deduced that Triton X-100 is deposited on the inner surface of the liner. This effect is beneficial since the resulting surfactant layer makes a surface which facilitates the pesticides transfer to the GC column. As a consequence, for some analytes, a substantial enhancement (up to 2.3 times) in the sensitivity was observed when the matrix-matched medium (0.09 % w/w Triton X-100 in organic solvent) is used compared to calibration in solely hexane or isooctane. Meanwhile, the measurement precision in the presence of Triton X-100 remains unchanged. The GC-MS/MS analysis was alternatively accomplished by the use of glass or metal liner and it was found that the glass one should be preferable. Finally, it can be concluded that cloud point extraction with Triton X-100 can be combined with GC-MS or GC-MS/MS analysis by applying liquid injection of the target analytes transferred in organic solvents such as hexane or isooctane. We have established a positive effect of Triton X-100 on the instrumental performance which is on opposite to the generally accepted concern of the negative influence of the surfactants on the gas chromatographic analysis.

6.
Anal Chim Acta ; 1264: 341305, 2023 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-37230723

RESUMO

Polymeric composite materials are gaining importance due to their universal applicability and easy adaptability for their intended use. For the comprehensive characterization of these materials, the concurrent determination of the organic and the elemental constituents is necessary, which cannot be provided by classical analysis methods. In this work, we present a novel approach for advanced polymer analysis. The proposed approach is based on firing a focused laser beam onto a solid sample placed in an ablation cell. The generated gaseous and particular ablation products are measured online parallelly by EI-MS and ICP-OES. This bimodal approach allows direct characterization of the main organic and inorganic constituents of solid polymer samples. The LA-EI-MS data showed excellent agreement with the literature EI-MS data allowing not only the identification of pure polymers but also of copolymers, as demonstrated with acrylonitrile butadiene styrene (ABS) as the sample. The concurrent collection of ICP-OES elemental data is vital for classification, provenance determination, or authentication studies. The applicability of the proposed procedure has been demonstrated by analysis of various polymer samples from everyday use.

7.
Food Chem ; 424: 136423, 2023 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-37247598

RESUMO

In this work, different sol-gel sorbent-coated second-generation fabric phase sorptive extraction (FPSE) membranes were synthesized using titania-based sol-gel precursors. The proposed membranes were tested for their efficiency to extract eleven selected organophosphorus pesticides (OPPs) from apple juice samples. Among the examined materials, sol-gel C18 coated titania-based FPSE membranes showed the highest extraction efficiency. These membranes were used for the optimization and validation of an FPSE method prior to analysis by gas chromatography-mass spectrometry. The detection limits for OPPs ranged between 0.03 and 0.08 ng mL-1. Moreover, the relative standard deviation was < 8.2% and 8.4% for intra-day and inter-day studies, respectively. The relative recoveries were 91-110% (intra-day study) and 90-106% (inter-day study) for all the target analytes, demonstrating good overall method accuracy. Moreover, the novel membranes were reusable at least 5 times. The titania-based membranes were compared to the conventional silica-based membranes and their utilization resulted in higher extraction recoveries.


Assuntos
Malus , Praguicidas , Cromatografia Gasosa-Espectrometria de Massas/métodos , Praguicidas/análise , Compostos Organofosforados/análise
8.
Anal Bioanal Chem ; 415(13): 2547-2560, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36629895

RESUMO

In this work, a solid-phase microextraction (SPME) Arrow method combined with comprehensive two-dimensional gas chromatography-mass spectrometry (GC × GC-MS) was developed for the elucidation of the volatile composition of honey samples. The sample preparation protocol was optimized to ensure high extraction efficiency of the volatile organic compounds (VOCs) which are directly associated with the organoleptic properties of honey and its acceptance by the consumers. Following its optimization, SPME Arrow was compared to conventional SPME in terms of sensitivity, precision, and number of extracted VOCs. The utilization of SPME Arrow fibers enabled the determination of 203, 147, and 149 compounds in honeydew honey, flower honey, and pine honey, respectively, while a significantly lower number of compounds (124, 94, and 111 for honeydew honey, flower honey, and pine honey, respectively) was determined using conventional SPME. At the same time, the utilization of SPME Arrow resulted in enhanced sensitivity and precision. All things considered, SPME Arrow and GC × GC-MS can be considered as highly suitable for the elucidation of the volatile composition of complex food samples resulting in high sensitivity and separation efficiency.


Assuntos
Mel , Compostos Orgânicos Voláteis , Cromatografia Gasosa-Espectrometria de Massas/métodos , Mel/análise , Microextração em Fase Sólida/métodos , Compostos Orgânicos Voláteis/análise
9.
Foods ; 11(23)2022 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-36496714

RESUMO

This study presents the first mid-infrared (IR)-based method capable of simultaneously predicting concentrations of individual fatty acids (FAs) and relevant sum parameters in human milk (HM). Representative fat fractions of 50 HM samples were obtained by rapid, two-step centrifugation and subsequently measured with attenuated total reflection IR spectroscopy. Partial least squares models were compiled for the acquired IR spectra with gas chromatography-mass spectrometry (GC-MS) reference data. External validation showed good results particularly for the most important FA sum parameters and the following individual FAs: C12:0 (R2P = 0.96), C16:0 (R2P = 0.88), C18:1cis (R2P = 0.92), and C18:2cis (R2P = 0.92). Based on the obtained results, the effect of different clinical parameters on the HM FA profile was investigated, indicating a change of certain sum parameters over the course of lactation. Finally, assessment of the method's greenness revealed clear superiority compared to GC-MS methods. The reported method thus represents a high-throughput, green alternative to resource-intensive established techniques.

10.
J Chromatogr A ; 1676: 463241, 2022 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-35763950

RESUMO

We present a novel sample preparation method for the extraction and preconcentration of volatile organic compounds from whiskey samples prior to their determination by comprehensive two-dimensional gas chromatography (GC × GC) coupled to mass spectrometry (MS). Sample preparation of the volatile compounds, important for the organoleptic characteristics of different whiskeys and their acceptance and liking by the consumers, is based on the use of the solid-phase microextraction (SPME) Arrow. After optimization, the proposed method was compared with conventional SPME regarding the analysis of different types of whiskey (i.e., Irish whiskey, single malt Scotch whiskey and blended Scotch whiskey) and was shown to exhibit an up to a factor of six higher sensitivity and better repeatability by a factor of up to five, depending on the compound class. A total of 167 volatile organic compounds, including terpenes, alcohols, esters, carboxylic acids, ketones, were tentatively-identified using the SPME Arrow technique, while a significantly lower number of compounds (126) were determined by means of conventional SPME. SPME Arrow combined with GC × GC-MS was demonstrated to be a powerful analytical tool for the exploration of the volatile profile of complex samples, allowing to identify differences in important flavour compounds for the three different types of whiskey investigated.


Assuntos
Microextração em Fase Sólida , Compostos Orgânicos Voláteis , Bebidas Alcoólicas/análise , Álcoois/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Microextração em Fase Sólida/métodos , Compostos Orgânicos Voláteis/análise
11.
Front Nutr ; 9: 856250, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35558753

RESUMO

This study provides the first assessment of the volatile metabolome map of Tuber Aestivum and Tuber Borchii originating from Greece using headspace solid-phase micro-extraction (HS-SPME) coupled to gas chromatography-mass spectrometry (GC-MS). For the extraction of the volatile fraction, the SPME protocol was optimized after examining the effects of sample mass, extraction temperature, and extraction time using the one-variable at-a-time approach (OVAT). The optimum parameters involved the extraction of 100 mg of homogenized truffle for 45 min at 50°C. Overall, 19 truffle samples were analyzed, and the acquired data were normalized and further processed with chemometrics. Agglomerative hierarchical clustering (HCA) was used to identify the groups of the two species. Partial least squares-discriminant analysis (PLS-DA) was employed to develop a chemometric model that could discriminate the truffles according to the species and reveal characteristic volatile markers for Tuber Aestivum and Tuber Borchii grown in Greece.

12.
J Chromatogr A ; 1672: 463026, 2022 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-35447527

RESUMO

Benzoyl urea insecticides are a class of pesticides used in agriculture for the inhibition of chitin synthesis in pests. These compounds are persistent in environmental samples, and thus their monitoring is necessary to avoid detrimental effects to human health and the environment. Magnet integrated fabric phase sorptive extraction (MI-FPSE) is a recently introduced sample preparation technique that combines sample stirring and analyte extraction into one stand-alone device. However, the applicability and the potential benefits of this technique in environmental analysis remain unexplored. In the present study, MI-FPSE was employed for the first time for the extraction and preconcentration of benzoyl urea insecticides (i.e., diflubenzuron, triflumuron, hexaflumuron, lufenuron and chlorfluazuron) from environmental water samples prior to their determination by high performance liquid chromatography-diode array detection (HPLC-DAD). The main factors affecting the performance of the proposed methodology were thoroughly investigated and optimized and the MI-FPSE-HPLC-DAD method was validated. The proposed method enabled the handling of relatively high sample quantity resulting in high preconcentration factors (501 and 731) and good sensitivity. Under optimum conditions, the limits of detection and the limits of quantification for the benzoyl urea insecticides were 0.06 ng mL-1 and 0.20 ng mL-1, respectively. Moreover, the relative standard deviations were less than 6.1% for intra-day study and less than 8.2% for inter-day study showing good method precision. After its validation, the herein developed method was successfully employed for the analysis of tap, mineral, river, and lake water samples. In addition, the ComplexGAPI index was used to present the green potential of developed method from the step of MI-FPSE device preparation to final determination. All things considered, MI-FPSE could potentially serve as an efficient tool for the monitoring of pollutants in environmental analysis.


Assuntos
Inseticidas , Poluentes Químicos da Água , Cromatografia Líquida de Alta Pressão , Humanos , Inseticidas/análise , Imãs , Ureia , Água , Poluentes Químicos da Água/análise
13.
RSC Adv ; 12(12): 7149-7156, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35424701

RESUMO

This study presents a fabric phase sorptive extraction (FPSE) protocol for the isolation and preconcentration of four selected polycyclic aromatic hydrocarbons from tea samples and herbal infusions, followed by their separation and quantification by gas chromatography-mass spectrometry (GC-MS). In FPSE, extraction of the target analytes is performed utilizing a flexible fabric substrate that is coated with a highly efficient sol-gel sorbent. In this work, eighteen different FPSE membranes were examined, with the highest extraction recoveries being observed with the sol-gel C18 coated FPSE membrane. The main parameters that influence the adsorption and desorption of the PAHs were optimized and the proposed method was validated. The detection limits and the quantification limits were 0.08-0.17 ng mL-1 and 0.25-0.50 ng mL-1, respectively, for the different target compounds with a 10 mL sample. The relative standard deviations for intra-day and inter-day repeatability were less than 7.9% and 8.5%, respectively. The sol-gel C18 coated FPSE membrane could be used for at least 5 subsequent sample preparation cycles. Finally, the proposed protocol was successfully employed for the determination of PAHs in a wide range of tea and herbal infusion samples.

14.
Appl Spectrosc ; 76(6): 730-736, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35119320

RESUMO

This study introduces the first mid-infrared (IR)-based method for determining the fatty acid composition of human milk. A representative milk lipid fraction was obtained by applying a rapid and solvent-free two-step centrifugation method. Attenuated total reflection Fourier transform infrared (ATR FT-IR) spectroscopy was applied to record absorbance spectra of pure milk fat. The obtained spectra were compared to whole human milk transmission spectra, revealing the significantly higher degree of fatty acid-related spectral features in ATR FT-IR spectra. Partial least squares (PLS)-based multivariate regression equations were established by relating ATR FT-IR spectra to fatty acid reference concentrations, obtained with gas chromatography-mass spectrometry (GC-MS). Good predictions were achieved for the most important fatty acid sum parameters: saturated fatty acids (SAT, R2CV = 0.94), monounsaturated fatty acids (MONO, R2CV = 0.85), polyunsaturated fatty acids (PUFA, R2CV = 0.87), unsaturated fatty acids (UNSAT, R2CV = 0.91), short-chain fatty acids (SCFA, R2CV = 0.79), medium-chain fatty acids (MCFA, R2CV = 0.97), and long-chain fatty acids (LCFA, R2CV = 0.88). The PLS selectivity ratio (SR) was calculated in order to optimize and verify each individual calibration model. All mid-IR regions with high SR could be assigned to absorbances from fatty acids, indicating high validity of the obtained models.


Assuntos
Ácidos Graxos , Leite Humano , Animais , Ácidos Graxos/análise , Humanos , Leite/química , Leite Humano/química , Solventes/análise , Espectrofotometria Infravermelho/métodos , Espectroscopia de Infravermelho com Transformada de Fourier/métodos
15.
Food Chem ; 373(Pt B): 131517, 2022 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-34772569

RESUMO

Triazine herbicides are a class of common pesticides which are widely used to control the weeds in many agricultural crops. Although many studies have described methodologies for the determination of triazine herbicides in aqueous samples, the attention given to agricultural crops and their products is far more limited. In this study, a novel sol-gel zwitterionic multi-mode fabric phase sorptive extraction (FPSE) platform was developed for the matrix clean-up, extraction and preconcentration of five triazine herbicides from fruit juice samples prior to their determination by high performance liquid chromatography-diode array detection (HPLC-DAD). The novel zwitterionic multi-mode sorbent was characterized and its performance for fruit juice analysis was evaluated. Compared to other sol-gel sorbents, the novel zwitterionic sorbent helped cleaning all the acidic interferences from fruit juices. The herein reported FPSE protocol was optimized and validated. Under optimum conditions, the FPSE method showed good accuracy, precision and sensitivity. The limits of detection and limits of quantification for all analytes were 0.15 ng mL-1 and 0.50 ng mL-1, respectively. The enhancement factors of this method ranged between 36.7 and 51.8. The relative standard deviation for intra-day precision was below 5.6% and for inter-day precision was below 8.8%. Finally, the proposed FPSE-HPLC-DAD method was successfully employed for the analysis of various fruit juice samples.


Assuntos
Herbicidas , Cromatografia Líquida de Alta Pressão , Herbicidas/análise , Têxteis , Triazinas , Água
16.
Talanta ; 234: 122710, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34364502

RESUMO

The determination of triazine herbicides in water samples is of utmost importance, due to their persistence and excessive use. However, since the concentration of triazine pesticides in real samples is low, an extraction/preconcentration step is typically required. Capsule phase microextraction (CPME) is a recently introduced sample preparation technique in which highly efficient sol-gel sorbents are encapsulated in a tubular polymer membrane. This particular design integrates the filtration and stirring mechanism into one extraction device, enabling the application of CPME for in situ sampling. In this study, CPME coupled to high performance liquid chromatography-diode array detection (HPLC-DAD) was employed for the first time for the determination of six triazine herbicides (i.e., simazine, cyanazine, atrazine, prometryn, terbuthylazine and propazine) in water samples. Microextraction capsules containing a moderately hydrophobic sol-gel Carbowax 20 M sorbent provided the highest extraction efficiency towards the examined pesticides. The main parameters affecting the adsorption and desorption steps of the CPME procedure were investigated and optimized. Under the selected conditions, limits of detection (signal/noise = 3.3) were 0.15 ng mL-1 for the target analytes. Moreover, the relative standard deviation for the within-day and between-days repeatability were less than 7.2% and 9.9%, respectively. The method was successfully applied to the analysis of mineral water, tap water, rainwater and lake water samples. The reported protocol could overcome the need for sample filtration prior to the sample preparation of the water samples, resulting in simplification of the overall sample handling, improved data quality with minimal loss of analytes and reduced sample preparation cost.


Assuntos
Herbicidas , Poluentes Químicos da Água , Cromatografia Líquida de Alta Pressão , Herbicidas/análise , Polietilenoglicóis , Triazinas/análise , Água , Poluentes Químicos da Água/análise
17.
Foods ; 10(5)2021 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-34064791

RESUMO

In the present study, a novel approach for mid-infrared (IR)-based prediction of bovine milk fatty acid composition is introduced. A rapid, solvent-free, two-step centrifugation method was applied in order to obtain representative milk fat fractions. IR spectra of pure milk lipids were recorded with attenuated total reflection Fourier-transform infrared (ATR-FT-IR) spectroscopy. Comparison to the IR transmission spectra of whole milk revealed a higher amount of significant spectral information for fatty acid analysis. Partial least squares (PLS) regression models were calculated to relate the IR spectra to gas chromatography/mass spectrometry (GC/MS) reference values, providing particularly good predictions for fatty acid sum parameters as well as for the following individual fatty acids: C10:0 (R2P = 0.99), C12:0 (R2P = 0.97), C14:0 (R2P = 0.88), C16:0 (R2P = 0.81), C18:0 (R2P = 0.93), and C18:1cis (R2P = 0.95). The IR wavenumber ranges for the individual regression models were optimized and validated by calculation of the PLS selectivity ratio. Based on a set of 45 milk samples, the obtained PLS figures of merit are significantly better than those reported in literature using whole milk transmission spectra and larger datasets. In this context, direct IR measurement of the milk fat fraction inherently eliminates covariation structures between fatty acids and total fat content, which poses a common problem in IR-based milk fat profiling. The combination of solvent-free lipid separation and ATR-FT-IR spectroscopy represents a novel approach for fast fatty acid prediction, with the potential for high-throughput application in routine lab operation.

18.
Food Chem ; 363: 130331, 2021 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-34139518

RESUMO

It is challenging to establish a correlation between the agronomical practices and the volatile profile of high-value agricultural products. In this study, the volatile metabolome of walnut oils from conventional and organic farming type was explored by HS-SPME-GC-MS. The SPME protocol was optimized after evaluating the effects of extraction time, extraction temperature, and sample mass. The optimum parameters involved the extraction of 0.500 g walnut oil at 40 °C within 60 min. Twenty Greek walnut oils produced with conventional and organic farming were analyzed and 41 volatile compounds were identified. The determined compounds were semi-quantified, and further processed with chemometrics. Agglomerative hierarchical clustering (AHC) and principal component analysis (PCA) were used. A robust classification model was developed using sparse partial least squares-discriminant analysis (sPLS-DA) for the discrimination of walnut oils into conventional and organic, establishing volatile markers that could be used to guarantee the type of farming.


Assuntos
Juglans , Compostos Orgânicos Voláteis , Cromatografia Gasosa-Espectrometria de Massas , Metaboloma , Óleos de Plantas , Microextração em Fase Sólida , Compostos Orgânicos Voláteis/análise
19.
Food Chem ; 354: 129518, 2021 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-33756324

RESUMO

The main objective of the present work was to develop a method for the simultaneous and comprehensive analysis of (poly-)phenolic and flavonoid compounds with liquid chromatography with diode array and mass spectrometric detection and its application to green asparagus samples. To this end, a representative set of polyphenols was used to develop the method. A through method validation was carried out with these. The method was applied to asparagus samples known as a healthy vegetable being rich in bioactive compounds. Polyphenol contents of asparagus samples were determined by carrying out quantitative and qualitative analyses by LC-DAD-ESI/MS. In this context asparagus sample extracts were obtained using solvents of different polarity. The results were evaluated statistically and showed that rutin is the major phenolic compound in asparagus. This demonstrates the versatility of this rapid and sensitive method for the simultaneous analysis of (poly-)phenolic and flavonoid compounds which was successfully applied to asparagus samples.


Assuntos
Asparagus/química , Flavonoides/química , Polifenóis/química , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas , Extratos Vegetais/química , Rutina/química
20.
RSC Adv ; 11(32): 19492-19499, 2021 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-35479258

RESUMO

A novel micro-meso porous activated carbon/Fe3O4 (Bm) composite was synthesized from the active charcoal precursor BAX-1500 and used in the magnetic solid-phase extraction (MSPE) of caffeine prior to its determination by gas chromatography-mass spectrometry (GC-MS). The main factors affecting the extraction and desorption steps of the MSPE procedure were investigated and optimized. These factors include extraction time, sorbent mass and salt addition for the adsorption step and type of eluent, desorption time and volume of desorption solution for the desorption step. Under optimum conditions, the absolute extraction recovery was found to be 91.1% and good linearity was observed in the investigated concentration range of 0.6-12.5 ng mL-1 (R 2 = 0.9997). The limit of detection was 0.18 ng mL-1 and the limit of quantification was 0.60 ng mL-1. The method was successfully applied to the analysis of surface water samples. The proposed MSPE method is simple, rapid, sensitive and environmentally friendly.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA