Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 87: 112-7, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24360858

RESUMO

The half-life of (176)Lu was determined by measuring the (176)Lu activity in metallic lutetium foils. Three different HPGe-detectors located 225 m underground were employed for the study. Measurements using the sum-peak method were performed and resulted in an average massic activity of (52.61±0.36) Bq g(-1). The foils were of natural isotopic abundance so using the massic activity and the value of the natural isotopic abundance of (2.59±0.01)%, a half-life of (3.722±0.029)×10(10)a could be calculated.

2.
Appl Radiat Isot ; 81: 81-6, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23743483

RESUMO

The newest development in IRMM's underground analytical facility is a large lead shield lined with copper that is versatile and can host several detectors of different types. The characteristics and the background performance of the shield are described for four different detector configurations involving HPGe-detectors and NaI-detectors. The shield has been designed to swap detectors, while still maintaining a low background. This enables testing of detectors for other experiments and optimisation of detection limits for specific radionuclides in different projects.


Assuntos
Proteção Radiológica/instrumentação , Radioisótopos/análise , Radiometria/instrumentação , Espectrometria gama/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Appl Radiat Isot ; 81: 103-8, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23602708

RESUMO

In underground HPGe-detector systems where the cosmic ray induced background is low, it is often difficult to assess the location of background sources. In this study, background counting rates of different HPGe-detectors in different lead shields are reported with the aim of better understanding background sources. To further enhance the understanding of the variations of environmental parameters, the background as a function of time over a long period was also studied.


Assuntos
Radiação de Fundo , Germânio/efeitos da radiação , Chumbo/efeitos da radiação , Proteção Radiológica/instrumentação , Espectrometria gama/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA