Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Bone Joint J ; 104-B(4): 433-443, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35360949

RESUMO

AIMS: The aim of this study was to compare any differences in the primary outcome (biphasic flexion knee moment during gait) of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) at one year post-surgery. METHODS: A total of 76 patients (34 bi-UKA and 42 TKA patients) were analyzed in a prospective, single-centre, randomized controlled trial. Flat ground shod gait analysis was performed preoperatively and one year postoperatively. Knee flexion moment was calculated from motion capture markers and force plates. The same setup determined proprioception outcomes during a joint position sense test and one-leg standing. Surgery allocation, surgeon, and secondary outcomes were analyzed for prediction of the primary outcome from a binary regression model. RESULTS: Both interventions were shown to be effective treatment options, with no significant differences shown between interventions for the primary outcome of this study (18/35 (51.4%) biphasic TKA patients vs 20/31 (64.5%) biphasic bi-UKA patients; p = 0.558). All outcomes were compared to an age-matched, healthy cohort that outperformed both groups, indicating residual deficits exists following surgery. Logistic regression analysis of primary outcome with secondary outcomes indicated that the most significant predictor of postoperative biphasic knee moments was preoperative knee moment profile and trochlear degradation (Outerbridge) (R2 = 0.381; p = 0.002, p = 0.046). A separate regression of alignment against primary outcome indicated significant bi-UKA femoral and tibial axial alignment (R2 = 0.352; p = 0.029), and TKA femoral sagittal alignment (R2 = 0.252; p = 0.016). The bi-UKA group showed a significant increased ability in the proprioceptive joint position test, but no difference was found in more dynamic testing of proprioception. CONCLUSION: Robotic arm-assisted bi-UKA demonstrated equivalence to TKA in achieving a biphasic gait pattern after surgery for osteoarthritis of the knee. Both treatments are successful at improving gait, but both leave the patients with a functional limitation that is not present in healthy age-matched controls. Cite this article: Bone Joint J 2022;103-B(4):433-443.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Artroplastia do Joelho/efeitos adversos , Humanos , Articulação do Joelho/cirurgia , Estudos Prospectivos
2.
Bone Joint J ; 103-B(10): 1561-1570, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34587803

RESUMO

AIMS: The aim of this study was to compare the clinical outcomes of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) during the first six weeks and at one year postoperatively. METHODS: A per protocol analysis of 76 patients, 43 of whom underwent TKA and 34 of whom underwent bi-UKA, was performed from a prospective, single-centre, randomized controlled trial. Diaries kept by the patients recorded pain, function, and the use of analgesics daily throughout the first week and weekly between the second and sixth weeks. Patient-reported outcome measures (PROMs) were compared preoperatively, and at three months and one year postoperatively. Data were also compared longitudinally and a subgroup analysis was conducted, stratified by preoperative PROM status. RESULTS: Both operations were shown to offer comparable outcomes, with no significant differences between the groups across all timepoints and outcome measures. Both groups also had similarly low rates of complications. Subgroup analysis for preoperative psychological state, activity levels, and BMI showed no difference in outcomes between the two groups. CONCLUSION: Robotic arm-assisted, cruciate-sparing bi-UKA offered similar early clinical outcomes and rates of complications to a mechanically aligned TKA, both in the immediate postoperative period and up to one year following surgery. Further work is required to identify which patients with osteoarthritis of the knee will derive benefit from a cruciate-sparing bi-UKA. Cite this article: Bone Joint J 2021;103-B(10):1561-1570.


Assuntos
Artroplastia do Joelho/métodos , Hemiartroplastia/métodos , Osteoartrite do Joelho/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Idoso , Artroplastia do Joelho/instrumentação , Método Duplo-Cego , Feminino , Seguimentos , Marcha , Hemiartroplastia/instrumentação , Humanos , Análise de Intenção de Tratamento , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente , Estudos Prospectivos , Resultado do Tratamento
3.
Bone Joint J ; 102-B(11): 1511-1518, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33135443

RESUMO

AIMS: The aim of this study was to compare robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) in order to determine the changes in the anatomy of the knee and alignment of the lower limb following surgery. METHODS: An analysis of 38 patients who underwent TKA and 32 who underwent bi-UKA was performed as a secondary study from a prospective, single-centre, randomized controlled trial. CT imaging was used to measure coronal, sagittal, and axial alignment of the knee preoperatively and at three months postoperatively to determine changes in anatomy that had occurred as a result of the surgery. The hip-knee-ankle angle (HKAA) was also measured to identify any differences between the two groups. RESULTS: The pre- to postoperative changes in joint anatomy were significantly less in patients undergoing bi-UKA in all three planes in both the femur and tibia, except for femoral sagittal component orientation in which there was no difference. Overall, for the six parameters of alignment (three femoral and three tibial), 47% of bi-UKAs and 24% TKAs had a change of < 2° (p = 0.045). The change in HKAA towards neutral in varus and valgus knees was significantly less in patients undergoing bi-UKA compared with those undergoing TKA (p < 0.001). Alignment was neutral in those undergoing TKA (mean 179.5° (SD 3.2°)) while those undergoing bi-UKA had mild residual varus or valgus alignment (mean 177.8° (SD 3.4°)) (p < 0.001). CONCLUSION: Robotic-assisted, cruciate-sparing bi-UKA maintains the natural anatomy of the knee in the coronal, sagittal, and axial planes better, and may therefore preserve normal joint kinematics, compared with a mechanically aligned TKA. This includes preservation of coronal joint line obliquity. HKAA alignment was corrected towards neutral significantly less in patients undergoing bi-UKA, which may represent restoration of the pre-disease constitutional alignment (p < 0.001). Cite this article: Bone Joint J 2020;102-B(11):1511-1518.


Assuntos
Artroplastia do Joelho , Articulação do Joelho/cirurgia , Procedimentos Cirúrgicos Robóticos , Idoso , Fenômenos Biomecânicos , Mau Alinhamento Ósseo/prevenção & controle , Feminino , Fêmur/cirurgia , Humanos , Articulação do Joelho/anatomia & histologia , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tíbia/cirurgia
4.
J Arthroplasty ; 33(7S): S109-S115, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29627257

RESUMO

BACKGROUND: Unicompartmental knee arthroplasty (UKA) for treatment of medial compartment osteoarthritis has potential benefits over total knee arthroplasty but UKA has a higher revision rate. Robotic-assisted UKA is increasingly common and offers more accurate implant positioning and limb alignment, lower early postoperative pain but evidence of functional outcome is lacking. The aim was to assess the clinical outcomes of a single-centre, prospective, randomised controlled trial, comparing robotic-arm-assisted UKA with conventional surgery. METHODS: A total of 139 participants were recruited and underwent robotic-arm-assisted (fixed bearing) or conventional (mobile bearing) UKA. Fifty-eight patients in the robotic-arm-assisted group and 54 in the manual group at 2 years. The main outcome measures were the Oxford Knee Score, American Knee Society Score and revision rate. RESULTS: At 2 years, there were no significant differences for any of the outcome measures. Sub-group analysis (n = 35) of participants with a preoperative University of California Los Angeles Activity Scale >5 (more active) was performed. In this sub-group, the median Oxford Knee Score at 2 years was 46 (IQR 42.0-48.0) for robotic-arm-assisted and 41 (IQR 38.5-44.0) for the manual group (P = .036). The median American Knee Society Score was 193.5 (IQR 184.0-198.0) for the robotic-arm-assisted group and 174.0 (IQR 166.0-188.5) for the manual group (P = .017). Survivorship was 100% in robotic-arm-assisted group and 96.3% in the manual group. CONCLUSION: Overall, participants achieved an outcome equivalent to the most widely implanted UKA in the United Kingdom. Sub-group analysis suggests that more active patients may benefit from robotic-arm- assisted surgery. Long term follow-up is required to evaluate differences in survivorship.


Assuntos
Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Procedimentos Cirúrgicos Robóticos , Adulto , Idoso , Feminino , Seguimentos , Humanos , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Dor Pós-Operatória/prevenção & controle , Estudos Prospectivos , Índice de Gravidade de Doença , Resultado do Tratamento , Reino Unido
5.
Int J Med Robot ; 14(1)2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28944574

RESUMO

BACKGROUND: Image registration (IR) is an important process of developing a spatial relationship between pre-operative data and the physical patient in the operation theatre. Current IR techniques for Computer Assisted Orthopaedic Surgery (CAOS) are time consuming and costly. There is a need to automate and accelerate this process. METHODS: Bespoke quick, cost effective, contactless and automated 3D laser scanning techniques based on the DAVID Laserscanner method were designed. 10 cadaveric knee joints were intra-operatively laser scanned and were registered with the pre-operative MRI scans. The results are supported with a concurrent validity study. RESULTS: The average absolute errors between scan models were systematically less than 1 mm. Errors on femoral surfaces were higher than tibial surfaces (P<0.05). Additionally, scans acquired through the large exposure produced higher errors than the smaller exposure (P<0.05). CONCLUSION: This study has provided proof of concept for a novel automated shape acquisition and registration technique for CAOS.


Assuntos
Fêmur/cirurgia , Imageamento Tridimensional/métodos , Articulação do Joelho/cirurgia , Procedimentos Ortopédicos/instrumentação , Procedimentos Ortopédicos/métodos , Tíbia/cirurgia , Algoritmos , Cadáver , Processamento Eletrônico de Dados , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por Computador , Período Intraoperatório , Lasers , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes , Cirurgia Assistida por Computador
6.
J Arthroplasty ; 31(5): 1102-8, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26718777

RESUMO

BACKGROUND: Heat from bone resecting tools used in knee surgery can induce thermal osteonecrosis, potentially causing aseptic implant loosening. This study compared oscillating saws to burrs in terms of temperature generation and histologic damage. Use of irrigation to reduce bone temperature was also investigated. METHODS: Temperatures were recorded during sawing and burring with or without irrigation (uncooled or cooled). Histologic analyses were then carried out. Differences between groups were tested statistically (α = 0.05). RESULTS: On average, burring produced higher temperatures than sawing (P < .001). When uncooled irrigation was used, bone temperatures were significantly lower in sawed bone than in burred bone (P < .001). Irrigation lowered temperatures and thermal damage depths and increased osteocyte viability (P < .001). CONCLUSION: These results suggest that irrigating bone during resection could prevent osteonecrosis onset.


Assuntos
Artroplastia do Joelho/efeitos adversos , Osso e Ossos/lesões , Osso e Ossos/cirurgia , Temperatura Alta/efeitos adversos , Osteonecrose/prevenção & controle , Irrigação Terapêutica , Animais , Artroplastia do Joelho/métodos , Temperatura Corporal , Bovinos , Sobrevivência Celular , Osteócitos/fisiologia , Osteonecrose/etiologia , Osteonecrose/fisiopatologia
7.
Hum Brain Mapp ; 37(2): 689-703, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26621010

RESUMO

OBJECTIVES: Recovery of independent ambulation after stroke is a major goal. However, which rehabilitation regimen best benefits each individual is unknown and decisions are currently made on a subjective basis. Predictors of response to specific therapies would guide the type of therapy most appropriate for each patient. Although lesion topography is a strong predictor of upper limb response, walking involves more distributed functions. Earlier studies that assessed the cortico-spinal tract (CST) were negative, suggesting other structures may be important. EXPERIMENTAL DESIGN: The relationship between lesion topography and response of walking speed to standard rehabilitation was assessed in 50 adult-onset patients using both volumetric measurement of CST lesion load and voxel-based lesion-symptom mapping (VLSM) to assess non-CST structures. Two functional mobility scales, the functional ambulation category (FAC) and the modified rivermead mobility index (MRMI) were also administered. Performance measures were obtained both at entry into the study (3-42 days post-stroke) and at the end of a 6-week course of therapy. Baseline score, age, time since stroke onset and white matter hyperintensities score were included as nuisance covariates in regression models. PRINCIPAL OBSERVATIONS: CST damage independently predicted response to therapy for FAC and MRMI, but not for walk speed. However, using VLSM the latter was predicted by damage to the putamen, insula, external capsule and neighbouring white matter. CONCLUSIONS: Walk speed response to rehabilitation was affected by damage involving the putamen and neighbouring structures but not the CST, while the latter had modest but significant impact on everyday functions of general mobility and gait. Hum Brain Mapp 37:689-703, 2016. © 2015 Wiley Periodicals, Inc.


Assuntos
Encéfalo/patologia , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral/patologia , Caminhada , Adulto , Idoso , Idoso de 80 Anos ou mais , Avaliação da Deficiência , Teste de Esforço , Feminino , Órtoses do Pé , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Recuperação de Função Fisiológica , Análise de Regressão , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/fisiopatologia , Resultado do Tratamento , Substância Branca/patologia
8.
Clin Biomech (Bristol, Avon) ; 30(7): 649-56, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26048241

RESUMO

BACKGROUND: A new sophisticated method that uses video analysis techniques together with a Maillon Rapide Delta to determine the tensile properties of the transverse carpal ligament-carpal tunnel complex has been developed. METHODS: Six embalmed cadaveric specimens amputated at the mid-forearm and aged (mean (SD)): 82 (6.29) years were tested. The six hands were from three males (four hands) and one female (two hands). Using trigonometry and geometry the elongation and strain of the transverse carpal ligament and carpal arch were calculated. The cross-sectional area of the transverse carpal ligament was determined. Tensile properties of the transverse carpal ligament-carpal tunnel complex and Load-Displacement data were also obtained. Descriptive statistics, one-way ANOVA together with a post-hoc analysis (Tukey) and t-tests were incorporated. FINDINGS: A transverse carpal ligament-carpal tunnel complex novel testing method has been developed. The results suggest that there were no significant differences between the original transverse carpal ligament width and transverse carpal ligament at peak elongation (P=0.108). There were significant differences between the original carpal arch width and carpal arch width at peak elongation (P=0.002). The transverse carpal ligament failed either at the mid-substance or at their bony attachments. At maximum deformation the peak load and maximum transverse carpal ligament displacements ranged from 285.74N to 1369.66N and 7.09mm to 18.55mm respectively. The transverse carpal ligament cross-sectional area mean (SD) was 27.21 (3.41)mm(2). INTERPRETATION: Using this method the results provide useful biomechanical information and data about the tensile properties of the transverse carpal ligament-carpal tunnel complex.


Assuntos
Síndrome do Túnel Carpal/fisiopatologia , Ligamentos Articulares/fisiologia , Resistência à Tração/fisiologia , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Cadáver , Feminino , Humanos , Masculino , Estresse Mecânico , Articulação do Punho/fisiologia
9.
J Arthroplasty ; 30(2): 199-205, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25263246

RESUMO

We report on the results of a randomized study (n=200) to compare total knee arthroplasty performed using conventional instrumentation or electromagnetic computer assisted surgical technique. 92% of navigated and 85% of conventional knees were implanted within ±3° from neutral mechanical alignment; there was no statistically significant difference between these proportions. There was also no difference in femoral or tibial rotation assessed by CT scan. At 1year follow up there was no statistical difference between the two groups in American Knee Society Score, Oxford Knee Scores, patient satisfaction, quality of life, hospital length of stay, complication rates or other adverse events. Tourniquet time in the navigated group was longer. Proving value for navigation in total knee arthroplasty surgery remains a challenge.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Cirurgia Assistida por Computador , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Eletromagnéticos , Feminino , Fêmur/cirurgia , Humanos , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Rotação , Método Simples-Cego , Tíbia/cirurgia , Tomografia Computadorizada por Raios X
10.
J Biomech ; 48(2): 324-31, 2015 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-25488137

RESUMO

This study investigated the feasibility of the uncontrolled manifold approach (UCM) to analyse gait data variability in relation to the control of the centre of mass (COM) in adults with and without neuropathology. The proposed method was applied to six able-bodied subjects to characterise mechanisms of normal postural control during stance phase. This approach was repeated on an early stroke patient, who attended the laboratory three times at three monthly intervals, to characterise the variability of COM movement during walking with and without an orthosis. Both able-bodied subjects and the stroke participant controlled COM movement during stance but utilized a different combination of lower limb joint kinematics to ensure that the COM trajectory was not compromised. Interestingly, the stroke subject, despite a higher variability in joint kinematics, was able to maintain a stable COM position throughout stance phase. The stabilisation of the COM decreased when the patient walked unaided without the prescribed orthosis but increased over the six months of study. The UCM analysis demonstrated how a stroke patient used a range of lower limb motion pattern to stabilise the COM trajectory. It is suggested that this analysis can be used to track changes in these movement patterns in response to rehabilitation. As such we propose that this approach could have clinical utility to evaluate and prescribe rehabilitation in stroke patients.


Assuntos
Marcha/fisiologia , Fenômenos Mecânicos , Adulto , Fenômenos Biomecânicos , Peso Corporal , Estudos de Viabilidade , Feminino , Humanos , Articulações/fisiologia , Articulações/fisiopatologia , Masculino , Aparelhos Ortopédicos , Postura , Acidente Vascular Cerebral/fisiopatologia , Caminhada/fisiologia
11.
Clin Orthop Relat Res ; 473(1): 206-12, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25002214

RESUMO

BACKGROUND: Surgical robotics has been shown to improve the accuracy of bone preparation and soft tissue balance in unicondylar knee arthroplasty (UKA). However, although extensive data have emerged with regard to a CT scan-based haptically constrained robotic arm, little is known about the accuracy of a newer alternative, an imageless robotic system. QUESTIONS/PURPOSES: We assessed the accuracy of a novel imageless semiautonomous freehand robotic sculpting system in performing bone resection and preparation in UKA using cadaveric specimens. METHODS: In this controlled study, we compared the planned and final implant placement in 25 cadaveric specimens undergoing UKA using the new tool. A quantitative analysis was performed to determine the translational, angular, and rotational differences between the planned and achieved positions of the implants. RESULTS: The femoral implant rotational mean error was 1.04° to 1.88° and mean translational error was 0.72 to 1.29 mm across the three planes. The tibial implant rotational mean error was 1.48° to 1.98° and the mean translational error was 0.79 to 1.27 mm across the three planes. CONCLUSIONS: The image-free robotic sculpting tool achieved accurate implementation of the surgical plan with small errors in implant placement. The next step will be to determine whether accurate implant placement translates into a clinical and functional benefit for the patient.


Assuntos
Artroplastia do Joelho/instrumentação , Fêmur/cirurgia , Articulação do Joelho/cirurgia , Robótica/instrumentação , Cirurgia Assistida por Computador/instrumentação , Tíbia/cirurgia , Pontos de Referência Anatômicos , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Cadáver , Desenho de Equipamento , Fêmur/anatomia & histologia , Fêmur/fisiologia , Humanos , Articulação do Joelho/anatomia & histologia , Articulação do Joelho/fisiologia , Prótese do Joelho , Teste de Materiais , Cirurgia Assistida por Computador/métodos , Tíbia/anatomia & histologia , Tíbia/fisiologia
12.
J Arthroplasty ; 29(2): 377-82, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23958234

RESUMO

Total hip arthroplasty (THA) is regarded as one of the most successful surgical procedures of modern times yet continues to be associated with a small but significant complication rate. Many early failures may be associated with poor component positioning with, in particular, acetabular component orientation dependent on the subjective judgement of the surgeon. In this paper, we compare the manufacturers' instructions on acetabular cup orientation with the literature-based recommended safety zones and surgical technique, by transforming them onto a single, clinically-relevant framework in which the different reference systems, safety guidelines and current instrumentation surgical techniques can be evaluated. The observed limited consensus between results reflects ongoing uncertainty regarding the optimum acetabular component positioning. As malpositioning of the acetabular cup increases the risk of revision surgery, any ambiguity over the correct position can have a causal effect. Our analysis highlights the need for a surgical reference system which can be used to describe the position of the acetabular cup intra-operatively.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Prótese de Quadril , Artroplastia de Quadril/instrumentação , Humanos , Sistema de Registros
13.
Int J Med Robot ; 10(2): 162-9, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23934937

RESUMO

BACKGROUND: Unicondylar knee replacement is technically challenging and malalignment of the implant components is one of the factors that results in high failure rates. Surgical robotics with navigation is emerging as a potential solution to improve the accuracy of implant placement. METHODS: The accuracy of performing unicondylar knee replacement using a freehand sculpting, semi-active robotic tool was investigated using 20 synthetic femurs and tibia. Resultant femoral and tibial implant placement was compared to the planned implant position. RESULTS: The maximum rotational error was 3.2(o) and RMS angular error was 1.46(o) across all orientations, for both the tibia and femoral implants. The maximum translational error was 1.18 mm and the RMS translational error across all directions was 0.61 mm. CONCLUSIONS: The freehand sculpting tool produced accurate implant placement with small errors comparable to those reported by other robotic-assistive devices on the market for unicondylar knee replacement.


Assuntos
Artroplastia do Joelho/instrumentação , Prótese do Joelho , Procedimentos Cirúrgicos Robóticos/instrumentação , Gráficos por Computador , Desenho de Equipamento , Fêmur/anatomia & histologia , Fêmur/cirurgia , Humanos , Articulação do Joelho/anatomia & histologia , Articulação do Joelho/cirurgia , Modelos Anatômicos , Cirurgia Assistida por Computador/instrumentação , Tíbia/anatomia & histologia , Tíbia/cirurgia
14.
Gait Posture ; 38(3): 483-9, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23465758

RESUMO

The purpose of this study was to investigate the clinical potential of an augmented-video-based-portable-system (AVPS). The AVPS included a walkway grid mat made of vinyl flooring, flat paper bull's eye markers, four photoswitches mounted on tripods, a light-indicator, a video camera, and a computer with ProTrainer System software. The AVPS output was compared to a "gold standard" 3D Vicon Motion Analysis System both statically and dynamically over a fixed range (-90° to +90°) using a two-segment-goniometric-rig marked with both bull's eye and retroreflective markers. At each segment angle position, three trials of data were captured. The reliability of the AVPS was also tested using three raters. Further twelve, young, healthy subjects participated in a concurrent validity study in which they performed six gait trials which were simultaneously recorded by both systems. Both motion analysis systems showed low levels of intra subject variability in all kinematic variables indicated by the size of the standard deviations across the six trials. There were no significant differences between the motion systems with respect to the kinematic variables (P>0.05). The results showed a high intra- and inter-rater reliability for both the kinematic and temporo-spatial parameters. With respect to gait events the lowest ICC value for the intra-rater reliability test was 0.993 for the kinematic variables, and ranged from 0.941 to 0.956 for the temporo-spatial variables and 0.731 to 0.954 for the tibia inclination angles. The validation data suggest the AVPS is capable of generating highly reliable and repeatable data when applied to normal subjects and could be used within the clinical setting.


Assuntos
Marcha/fisiologia , Software , Gravação em Vídeo/métodos , Adulto , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Adulto Jovem
15.
Clin Biomech (Bristol, Avon) ; 28(1): 23-8, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23083704

RESUMO

BACKGROUND: Navigated total knee arthroplasty has been shown to increase accuracy in post operative implant alignment. By contrast navigated total knee arthroplasty has not shown significant functional improvements to date, when compared with conventional surgery using subjective clinical questionnaire scores. The aim of this study was to compare the knee joint kinematics measured during functional activities using electrogoniometry 12 months after total knee arthroplasty in randomised navigated and conventional total knee arthroplasty groups. METHODS: The study design was a double blinded, randomised, prospective, controlled trial. The patients were randomised into 2 surgical groups (n=102 navigated group, n=98 conventional group; mean age navigated=67, conventional=67). Flexible electrogoniometry was used to measure patient's knee kinematics with respect to time during 12 functional activities. FINDINGS: No significant difference was found in terms of the maximum, minimum and excursion knee joint angle during any of the functional activities. However there was a statistically significant improvement in the level and slope gait cycle at the pre swing phase in the navigated group. INTERPRETATION: There were minimal functional improvements in the navigated total knee arthroplasty group 12 months after surgery. However, these are unlikely to have a significant effect on daily activity for the navigated group.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/fisiopatologia , Monitorização Intraoperatória/métodos , Osteoartrite do Joelho/fisiopatologia , Osteoartrite do Joelho/cirurgia , Cirurgia Assistida por Computador , Atividades Cotidianas , Adulto , Idoso , Idoso de 80 Anos ou mais , Artrometria Articular , Fenômenos Biomecânicos , Método Duplo-Cego , Fenômenos Eletromagnéticos , Feminino , Marcha , Humanos , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios , Estudos Prospectivos , Resultado do Tratamento
16.
Health Informatics J ; 18(3): 171-80, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23011812

RESUMO

This article describes the ongoing process of engaging with users in the development and evaluation of prototype visualisation software, which aims to assist in the understanding and improvement of appropriate movements during rehabilitation. The value of the process is illustrated in the article with a discussion of the key findings of pre-pilot focus groups with stroke survivors and therapists. The article describes how the design of the visualisation software is being adapted to meet the emerging understanding of the needs of patients and professionals, and of the rehabilitation process.


Assuntos
Medicina Baseada em Evidências/métodos , Processamento de Imagem Assistida por Computador/instrumentação , Fisioterapeutas , Reabilitação/instrumentação , Design de Software , Reabilitação do Acidente Vascular Cerebral , Sobreviventes , Fenômenos Biomecânicos , Terapia por Exercício/métodos , Retroalimentação Sensorial , Grupos Focais , Humanos , Modelos Biológicos , Avaliação das Necessidades , Projetos Piloto , Relações Profissional-Paciente , Desenvolvimento de Programas , Pesquisa Qualitativa , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento , Interface Usuário-Computador
17.
Trials ; 12: 254, 2011 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-22141471

RESUMO

BACKGROUND: There are a number of gaps in the evidence base for the use of ankle-foot orthoses for stroke patients. Three dimensional motion analysis offers an ideal method for objectively obtaining biomechanical gait data from stroke patients, however there are a number of major barriers to its use in routine clinical practice. One significant problem is the way in which the biomechanical data generated by these systems is presented. Through the careful design of bespoke biomechanical visualisation software it may be possible to present such data in novel ways to improve clinical decision making, track progress and increase patient understanding in the context of ankle-foot orthosis tuning. METHODS: A single-blind randomised controlled trial will be used to compare the use of biomechanical visualisation software in ankle-foot orthosis tuning against standard care (tuning using observation alone). Participants (n = 70) will have experienced a recent hemiplegia (1-12 months) and will be identified by their care team as being suitable candidates for a rigid ankle-foot orthosis. The primary outcome measure will be walking velocity. Secondary outcome measures include; lower limb joint kinematics (thigh and shank global orientations) & kinetics (knee and hip flexion/extension moments, ground reaction force FZ2 peak magnitude), step length, symmetry ratio based on step length, Modified Ashworth Scale, Modified Rivermead Mobility Index and EuroQol (EQ-5D). Additional qualitative measures will also be taken from participants (patients and clinicians) at the beginning and end of their participation in the study. The main aim of the study is to determine whether or not the visualisation of biomechanical data can be used to improve the outcomes of tuning ankle-foot orthoses for stroke patients. DISCUSSION: In addition to answering the primary research question the broad range of measures that will be taken during this study are likely to contribute to a wider understanding of the impact of ankle-foot orthoses on the lives of stroke patients. TRIAL REGISTRATION NUMBER: ISRCTN: ISRCTN52126764.


Assuntos
Protocolos Clínicos , Aparelhos Ortopédicos , Reabilitação do Acidente Vascular Cerebral , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Tornozelo , Fenômenos Biomecânicos , Feminino , , Marcha , Humanos , Masculino , Pessoa de Meia-Idade , Projetos de Pesquisa , Método Simples-Cego , Acidente Vascular Cerebral/fisiopatologia
18.
Gait Posture ; 33(3): 447-51, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21300548

RESUMO

Hypermobility syndrome (HMS) is characterised by generalised joint laxity and musculoskeletal complaints. Gait abnormalities have been reported in children with HMS but have not been empirically investigated. The extent of passive knee joint range of motion (ROM) has also not been well reported in children with HMS. This study evaluated gait kinematics and passive knee joint ROM in children diagnosed with HMS and healthy controls. Thirty-seven healthy children (mean age±SD=11.5±2.6 years) and 29 children with HMS (mean age±SD=11.9±1.8 years) participated. Sagittal knee motion and gait speed were evaluated using a VICON 3D motion analysis system. Passive knee ROM was measured with a manual goniometer. Independent t-tests compared the values of sagittal knee motion and gait speed between the two groups. Mann-Whitney U tests compared passive knee ROM between groups. Passive ROM (extension and flexion) was significantly higher (both p<0.001) in children with HMS than the healthy controls. Peak knee flexion (during loading response and swing phase) during walking was significantly lower (both p<0.001) in children with HMS. Knee extension in mid stance during walking was significantly increased (p<0.001) in children with HMS. However, gait speed was not statistically (p=0.496) different between the two groups. Children with HMS had higher passive knee ROM than healthy children and also demonstrated abnormal knee motion during gait. Gait re-education and joint stability exercise programmes may be of value to children with HMS.


Assuntos
Marcha/fisiologia , Instabilidade Articular/diagnóstico , Articulação do Joelho , Debilidade Muscular/diagnóstico , Amplitude de Movimento Articular/fisiologia , Adolescente , Fatores Etários , Fenômenos Biomecânicos , Estudos de Casos e Controles , Criança , Feminino , Humanos , Instabilidade Articular/complicações , Masculino , Debilidade Muscular/complicações , Valores de Referência , Medição de Risco , Fatores Sexuais , Estatísticas não Paramétricas , Síndrome
19.
J Med Eng Technol ; 33(8): 650-5, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19848859

RESUMO

OBJECTIVE: Our aim was to develop and validate a user-friendly data logger system (SUDALS) for use with flexible electrogoniometry. METHODS: Data pertaining to flexion/extension of the knee from 10 normal subjects were collected during a range of activities of daily living (ADL) such as walking, ascending and descending stairs, getting in and out of a chair and deep squatting. The accuracy, reliability and reproducibility of the data from SUDALS were verified by comparing against the data simultaneously collected from the Vicon system. RESULTS: The results of these studies indicate that the SUDALS together with flexible electrogoniometers is able to produce stable, precise, accurate and repeatable knee flexion/extension angles with little variation existing between the data produced by the SUDALS, the Vicon system and that reported in the literature. CONCLUSION: The SUDALS together with flexible electrogoniometers is a useful clinical tool, capable of recording knee flexion/extension angles accurately during ADL.


Assuntos
Artrometria Articular/estatística & dados numéricos , Articulação do Joelho/fisiologia , Amplitude de Movimento Articular/fisiologia , Atividades Cotidianas , Adulto , Artrometria Articular/instrumentação , Artroplastia do Joelho , Fenômenos Biomecânicos , Engenharia Biomédica , Ensaios Clínicos como Assunto/estatística & dados numéricos , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Adulto Jovem
20.
Gerontology ; 55(6): 621-9, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19729881

RESUMO

BACKGROUND: Strength of lower extremity muscles is an important determinant of mobility-based functional activities. Loss of strength with age produces functional limitation in activities of daily living such as rising from a chair or stair negotiation. However, there is limited information on the effect of age-related changes on the torque-producing ability of muscles through their ranges of joint motion. OBJECTIVE: To investigate the effect of ageing on the torque-producing ability of lower extremity muscles in a large sample of older adults in three age groups. METHODS: Eighty-two volunteers participated in this study and were divided into six groups according to their chronological age (60s, 70s and 80s and above) and gender (male, female). Isometric muscle strength was measured at the knee and hip joints at three positions through the joint range using a custom-built strain gauge torque dynamometer and a purpose built plinth. RESULTS: The peak torque of major muscle groups of the knee and hip joints decreased with increasing age at all the three joint positions at which strength was tested. The 80-year-olds had 20% lower strength compared to the 60-year-olds. Age-related decrease in muscle strength was significant when comparing 80-year-olds with the 60-year-olds (p < 0.05). Strength loss was noted to be higher at the inner (muscle is shortened from mid-position) and outer (muscle is lengthened from mid-position) ranges of muscle action when compared with the mid-range position (mid-position). Gender-based differences were significant for all the strength tests (p < 0.05). CONCLUSIONS: Strength decreased with increasing age at all the positions within joint range of motion for knee and hip joints. However, the percentage loss of muscle strength was different at different positions in the joint range. Our findings suggest that muscle strength was more preserved in the middle range of muscle function compared to the inner and outer range of muscle action. In older people, lower extremity muscles might be required to produce higher moments in joint positions that are not within the optimum mid-position for muscle action.


Assuntos
Envelhecimento/fisiologia , Articulação do Quadril/fisiologia , Contração Isométrica/fisiologia , Articulação do Joelho/fisiologia , Idoso , Idoso de 80 Anos ou mais , Bases de Dados Factuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dinamômetro de Força Muscular , Torque
SELEÇÃO DE REFERÊNCIAS