Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Talanta ; 277: 126417, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38901191

RESUMO

Agronomic biofortification using selenium nanoparticles (SeNPs) shows potential for addressing selenium deficiency but further research on SeNPs-plants interaction is required before it can be effectively used to improve nutritional quality. In this work, single-particle inductively coupled plasma-mass spectrometry (SP-ICP-MS) was used for tracing isotopically labeled SeNPs (82SeNPs) in Oryza sativa L. tissues. For this purpose, SeNPs with natural isotopic abundance and 82SeNPs were synthesized by a chemical method. The NPs characterization by transmission electron microscopy (TEM) confirmed that enriched NPs maintained the basic properties of unlabeled NPs, showing spherical shape, monodispersity, and sizes in the nano-range (82.8 ± 6.6 nm and 73.2 ± 4.4 nm for SeNPs and 82SeNPs, respectively). The use of 82SeNPs resulted in an 11-fold enhancement in the detection power for ICP-MS analysis, accompanied by an improvement in the signal-to-background ratio and a reduction of the size limits of detection from 89.9 to 39.9 nm in SP-ICP-MS analysis. This enabled 82SeNPs to be tracked in O. sativa L. plants cultivated under foliar application of 82SeNPs. Tracing studies combining SP-ICP-MS and TEM-energy-dispersive X-ray spectroscopy data confirmed the uptake of intact 82SeNPs by rice leaves, with most NPs remaining in the leaves and very few particles translocated to shoots and roots. Translocation of Se from leaves to roots and shoots was found to be lower when applied as NPs compared to selenite application. From the size distributions, as obtained by SP-ICP-MS, it can be concluded that a fraction of the 82SeNPs remained within the same size range as that of the applied NP suspension, while other fraction underwent an agglomeration process in the leaves, as confirmed by TEM images. This illustrates the potential of SP-ICP-MS analysis of isotopically enriched 82SeNPs for tracing NPs in the presence of background elements within complex plant matrices, providing important information about the uptake, accumulation, and biotransformation of SeNPs in rice plants.

2.
Talanta ; 276: 126210, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38728804

RESUMO

High-precision isotopic analysis of mercury (Hg) using multi-collector ICP-mass spectrometry (MC-ICP-MS) is a powerful method for obtaining insight into the sources, pathways and sinks of this toxic metal. Modification of a commercially available mercury analyzer (Teledyne Leeman Labs, Hydra IIc - originally designed for quantification of Hg through sample combustion, collection of the Hg vapor on a gold amalgamator, subsequent controlled release of Hg and detection using cold vapor atomic absorption spectrometry CVAAS) enabled the system to be used for the direct high-precision Hg isotopic analysis of solid samples using MC-ICP-MS - i.e., without previous sample digestion and subsequent dilution. The changes made to the mercury analyzer did not compromise its (simultaneous) use for Hg quantification via CVAAS. The Hg vapor was mixed with a Tl-containing aerosol produced via pneumatic nebulization, creating wet plasma conditions, and enabling the use of Tl as an internal standard for correction of instrumental mass discrimination. Accurate and precise (0.10 ‰ 2SD, δ202Hg, n = 5) results were obtained for an in-house standard solution of Hg (20 ng Hg sample intake). Initial validation relied on the successful analysis of two solid certified reference materials of biological origin (BCR CRM 464 Tuna fish and NRC-CNRC TORT-3 Lobster hepatopancreas). It was shown that instrumental mass discrimination can be adequately corrected for by relying on the use of an aqueous Hg standard solution (NIST SRM 3133), without the need of matrix-matching. The novel setup developed thus allows for direct high-precision isotopic analysis of Hg in solid samples, thus enhancing the sample throughput. It is also suited for samples for which low amounts are available only and/or that are characterized by low Hg concentrations.

3.
Anal Chem ; 95(50): 18579-18586, 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38050919

RESUMO

In this work, laser ablation (LA) was characterized as a method for sampling and introducing microplastic particles (MPs) into an inductively coupled plasma (ICP) for subsequent 13C+ monitoring using an ICP-mass spectrometer operated in single-event mode. MPs of different types (PS, PMMA, and PVC) and sizes (2-20 µm) were introduced intactly. The laser energy density did not affect the particle sampling across a wide range (0.25-6.00 J cm-2). Single-shot analysis separated clustered MPs (2-7 MPs per cluster) during the LA and particle transport processes, allowing the temporally resolved analysis of the individual constituting MPs. Line scanning showed superior performance when using a small laser beam diameter combined with a high repetition rate. The 13C+ signal intensity correlated linearly (R2 >0.9945) with the absolute C mass in a 2-10 µm size range, while the use of He in the collision-reaction cell (CRC) allowed extension of the linear range to 20 µm. The LA approach generated narrower 13C+ signal distributions than the traditional solution-based approach (dry versus wet plasma conditions) and proved successful for the analysis of a mixed suspension (containing four sizes of PS MPs in a 2-5 µm size range) and for sampling MPs from PVDF and glass microfiber filters, with the latter offering a lower background.

4.
Anal Chim Acta ; 1077: 95-106, 2019 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-31307726

RESUMO

In this work, the effects of using collision/reaction cell (CRC) technology in quadrupole-based ICP-MS (ICP-QMS) instrumentation operated in single-particle (SP) mode have been assessed. The influence of (i) various CRC gases, (ii) gas flow rates, (iii) nanoparticle (NP) sizes and (iv) NP types was evaluated using Ag, Au and Pt NPs with both a traditional ICP-QMS instrument and a tandem ICP-mass spectrometer. It has been shown that using CRC technology brings about a significant increase in the NP signal peak width (from 0.5 up to 6 ms). This effect is more prominent for a heavier gas (e.g., NH3) than for a lighter one (e.g., H2 or He). At a higher gas flow rate and/or for larger particle sizes >100 nm), the NP signal duration was prolonged to a larger extent. This effect of using CRC technology has been further demonstrated by characterizing custom-made 50 and 200 nm Fe3O4 NPs (originally strongly affected by the occurrence of spectral overlap) using different CRC approaches (H2 on-mass and NH3 mass-shift). The use of NH3 (monitoring of Fe as the Fe(NH3)2+ reaction product ion at m/z = 90 amu) induces a significant peak broadening compared to that observed when using H2 (6.10 ±â€¯1.60 vs. 0.94 ±â€¯0.49 ms). This extension of transit time can most likely be attributed to the collisions/interactions of the ion cloud generated by a single NP event with the CRC gas and it even precludes 50 nm Fe3O4 NPs to be detected when using the NH3 mass-shift approach. Based on these results, the influence of a longer peak width on the accuracy of SP-ICP-MS measurement data (NP size, particle number density and mass concentration) must be taken into account when using CRC technology as a means to overcome spectral overlap. To mitigate the potential detrimental effect of using CRC technology in the characterization of NPs via SP-ICP-MS(/MS), the use of light gases and low gas flow rates is recommended.

5.
Sci Rep ; 9(1): 7262, 2019 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-31086275

RESUMO

Whales accumulate mercury (Hg), but do not seem to show immediate evidence of toxic effects. Analysis of different tissues (liver, kidney, muscle) and biofluids (blood, milk) from a pod of stranded long-finned pilot whales (Globicephala melas) showed accumulation of Hg as a function of age, with a significant decrease in the MeHg fraction. Isotopic analysis revealed remarkable differences between juvenile and adult whales. During the first period of life, Hg in the liver became isotopically lighter (δ202Hg decreased) with a strongly decreasing methylmercury (MeHg) fraction. We suggest this is due to preferential demethylation of MeHg with the lighter Hg isotopes and transport of MeHg to less sensitive organs, such as the muscles. Also changes in diet, with high MeHg intake in utero and during lactation, followed by increasing consumption of solid food contribute to this behavior. Interestingly, this trend in δ202Hg is reversed for livers of adult whales (increasing δ202Hg value), accompanied by a progressive decrease of δ202Hg in muscle at older ages. These total Hg (THg) isotopic trends suggest changes in the Hg metabolism of the long-finned pilot whales, development of (a) detoxification mechanism(s) (e.g., though the formation of HgSe particles), and Hg redistribution across the different organs.


Assuntos
Compostos de Mercúrio/metabolismo , Baleias Piloto/metabolismo , Fatores Etários , Animais , Feminino , Rim/química , Fígado/química , Masculino , Espectrometria de Massas , Compostos de Mercúrio/análise , Compostos de Mercúrio/sangue , Radioisótopos de Mercúrio/análise , Radioisótopos de Mercúrio/metabolismo , Leite/química , Músculo Esquelético/química
6.
Environ Sci Technol ; 53(4): 1776-1785, 2019 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-30652479

RESUMO

Liver and muscle tissue of tusks ( Brosme brosme) have been analyzed for their THg and MeHg concentrations and Hg isotopic signatures for tracing Hg pollution along the Norwegian coast. Clear differences between tissue types and locations were established. At five of the eight locations, the Hg concentration in muscle exceeded the maximum allowable level of 0.5 mg kg-1 wet weight. δ202Hg values in both tissue types indicated that Hg speciation affects the bulk Hg isotopic signature. Tusk liver seems to be more sensitive to immediate changes and to anthropogenic inorganic Hg, while the muscle rather reflects the Hg accumulated over a longer period of exposure. The δ202Hg values of liver and muscle also enabled different sources of Hg and exposure pathways to be distinguished. δ202Hgmuscle-δ202Hgliver showed a clear correlation with the % MeHg in tusk liver for the coastal waters, but not for the fjords. The absence of significant differences in Δ199Hg values between both tissues of tusk from the same location suggests that in vivo metabolic processes are the underlying reason for the differences in Hg speciation and in δ202Hg values. This work highlights the importance of selecting different tissues of marine fish in future Hg monitoring programs.


Assuntos
Mercúrio , Compostos de Metilmercúrio , Poluentes Químicos da Água , Animais , Monitoramento Ambiental , Peixes , Fígado , Noruega , Água
7.
RSC Adv ; 9(51): 29902-29908, 2019 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-35531518

RESUMO

H2O2 was demonstrated to narrow the size distribution and decrease the size of CuO and hydrous FeOOH (2-line ferrihydrite) nanoparticles under conditions of high supersaturation. We introduce oxidation-assisted alkaline precipitation (Ox-AP) and compare it to traditional alkaline precipitation (AP). While for AP, a metal salt solution (e.g., CuCl2) is mixed with an alkali (e.g., NaOH), for Ox-AP, the more reduced form of that metal salt solution (e.g., CuCl) is simultaneously mixed with that alkali and an oxidant (e.g., H2O2). The resulting precipitates were characterized with SEM, XRD, DLS and single particle ICP-MS and shown to be nanoparticles (NPs). Ox-AP CuO NPs were up to 3 times smaller than AP NPs. Ox-AP FeOOH NPs were up to 22.5% smaller than AP NPs. We discuss and propose a possible mechanism of Ox-AP through careful consideration of the known reaction chemistry of iron and copper. We propose that an increased monomer formation rate enhances the nucleation rate, which ultimately results in smaller particles with a more narrow distribution. The more distinct effect of Ox-AP on copper, was attributed to the fast formation of the stable CuO monomer, compared to AP, where the Cu(OH)2 and/or Cu2(OH)3Cl monomers are more likely formed. Although, the exact mechanism of Ox-AP needs experimental confirmation, our results nicely demonstrate the potential of using Ox-AP to produce smaller NPs with a more narrow distribution in comparison to using AP.

8.
Environ Sci Technol ; 50(19): 10361-10369, 2016 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-27609466

RESUMO

Hg pollution released from the U-864 submarine sunk during WWII and potential introduction of that Hg into the marine food chain have been studied by a combination of quantitative Hg and MeHg determination and Hg isotopic analysis via cold vapor generation multicollector inductively coupled plasma-mass spectrometry (CVG-MC-ICP-MS) in sediment and Cancer pagurus samples. The sediment pollution could be unequivocally linked with the metallic Hg present in the wreck. Crabs were collected at the wreck location and 4 nmi north and south, and their brown and claw meat were analyzed separately. For brown meat, the δ202Hg values of the individuals from the wreck location were shifted toward the isotopic signature of the sediment and, thus, the submarine Hg. Such differences were not found for claw meat. The isotope ratio results suggest direct ingestion of metallic Hg by C. pagurus but do not offer any proof for any other introduction of the submarine Hg into the marine food chain.


Assuntos
Braquiúros , Mercúrio , Animais , Poluição Ambiental , Gases , Isótopos/química
9.
Anal Bioanal Chem ; 408(2): 417-29, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26549115

RESUMO

Mercury (Hg) isotopic analysis via multi-collector inductively coupled plasma (ICP)-mass spectrometry (MC-ICP-MS) can provide relevant biogeochemical information by revealing sources, pathways, and sinks of this highly toxic metal. In this work, the capabilities and limitations of two different sample introduction systems, based on pneumatic nebulization (PN) and cold vapor generation (CVG), respectively, were evaluated in the context of Hg isotopic analysis via MC-ICP-MS. The effect of (i) instrument settings and acquisition parameters, (ii) concentration of analyte element (Hg), and internal standard (Tl)-used for mass discrimination correction purposes-and (iii) different mass bias correction approaches on the accuracy and precision of Hg isotope ratio results was evaluated. The extent and stability of mass bias were assessed in a long-term study (18 months, n = 250), demonstrating a precision ≤0.006% relative standard deviation (RSD). CVG-MC-ICP-MS showed an approximately 20-fold enhancement in Hg signal intensity compared with PN-MC-ICP-MS. For CVG-MC-ICP-MS, the mass bias induced by instrumental mass discrimination was accurately corrected for by using either external correction in a sample-standard bracketing approach (SSB) or double correction, consisting of the use of Tl as internal standard in a revised version of the Russell law (Baxter approach), followed by SSB. Concomitant matrix elements did not affect CVG-ICP-MS results. Neither with PN, nor with CVG, any evidence for mass-independent discrimination effects in the instrument was observed within the experimental precision obtained. CVG-MC-ICP-MS was finally used for Hg isotopic analysis of reference materials (RMs) of relevant environmental origin. The isotopic composition of Hg in RMs of marine biological origin testified of mass-independent fractionation that affected the odd-numbered Hg isotopes. While older RMs were used for validation purposes, novel Hg isotopic data are provided for the latest generations of some biological RMs.


Assuntos
Isótopos/química , Espectrometria de Massas/métodos , Mercúrio/química , Gases/química , Volatilização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA