RESUMO
This state-of-the-art review aimed to synthesize evidence from various sex-stratified studies on aortic stenosis (AS), focusing on the difference in clinical presentation, anatomical characteristics, pathophysiology, and management of AS. In comparison to men, women with AS are present at later stages, are older, more symptomatic, frailer, and exhibit higher operative risk [Society of Thoracic Surgeons (STS) score]. Women tend to have smaller aortic valve (AV) areas and left ventricular (LV) outflow tract, leading to lower stroke volumes (SVs) than men and have a higher prevalence of paradoxical, low-flow, low-gradient AS. In women, chronic pressure overload due to AS results in concentric LV remodelling and hypertrophy, characterized by reduced LV cavities, higher filling pressures, lower wall stress, and more diastolic dysfunction. Conversely, men exhibit more dilated eccentric LV remodelling and hypertrophy. AVs in women are less calcified but more fibrotic. Moreover, women are often underdiagnosed, have severity underestimated, and experience delays or receive fewer referrals for AV replacement (AVR). However, women tend to benefit from transcatheter AVR (TAVR) with a long-term survival advantage over men, although the incidence of vascular complications and bleeding events in 30 days after TAVR is higher in women. Surgical AVR (SAVR) in women has high operative risk, is technically demanding and has poorer outcomes with increased mortality at 30 days compared to men. According to the STS score and EuroSCORE, the female sex itself is considered a risk factor for SAVR. Therefore, addressing sex-related disparities in AS and increasing awareness among physicians promises improved diagnosis and treatment, facilitating equitable care and the development of sex-specific personalized medicine.
RESUMO
BACKGROUND: Transcatheter tricuspid valve intervention (TTVI) has shown promising results with persistent reduction of tricuspid regurgitation (TR) and improvements in functional class and quality of life (QOL). OBJECTIVES: To analyze the impact of TTVI on maximal and submaximal exercise capacity (SEC). METHODS: Constant work-rate exercise-time (CWRET) testing reflects SEC, which is more likely to be relevant for daily life activities and provides more differentiated physiological insight into the nature of exercise intolerance. Thus, 30 patients undergoing TTVI (21 direct annuloplasty and 9 edge-to-edge repair) received cardiopulmonary exercise testing (CPET) and CWRET (at 75% of maximum work rate in the initial CPET) before and 3 months after TTVI. RESULTS: Patients' age was 80.5 [74.8-82.3] years and 53.3% were female. TR reduction ≥ 2 grades was achieved in 93.3% (TR grade ≤ moderate in 83.3%). Echocardiography revealed improved right ventricular (RV) characteristics with decreased RV basal diameter (47.0 mm [43.0-54.3] vs. 41.5 mm [36.8-48.0]; p < 0.001) and decreased inferior caval vein diameter. CWRET testing showed a significantly improved SEC (246.5 s [153.8-416.8] vs. 338.5 s [238.8-611.8] p = 0.001). Maximum oxygen uptake showed a positive trend without statistically significant differences (9.9 ml/min/kg [8.6-12.4] vs. 11.7 ml/min/kg [9.7-13.3]; p = 0.31). In contrast to the six-minute-walking distance (6MWD), SEC correlated moderately with effective regurgitation orifice area reduction (r = 0.385; p = 0.036), increased cardiac output (r = 0.378; p = 0.039), and improved QOL (r = 387; p = 0.035). CONCLUSION: Improvements in exercise capacity after TTVI mainly occur in the submaximal rather than in the maximal exercise range and correlate with hemodynamic effects and QOL. This may have a methodological impact on assessment of exercise capacity in these patients.
RESUMO
BACKGROUND AND OBJECTIVE: Within recent years, transcatheter tricuspid edge-to-edge repair (T-TEER) has emerged as a safe and effective treatment option in patients with secondary tricuspid regurgitation (TR). However, for primary TR, data on the robustness and durability of TR reduction 1 year following T-TEER is limited. METHODS: All consecutive patients treated with T-TEER for TR at two high-volume centers between September 2018 and December 2022 were enrolled in a registry. Primary TR was defined as tricuspid valve (TV) prolapse or flail TV leaflets as assessed by pre- and peri-interventional transesophageal echocardiography (TEE). RESULTS: 201 patients were included in this analysis, of whom 27 (13.4%) were classified as primary TR and 174 (86.6%) as TR of secondary origin. All-cause mortality during 1-year follow-up was reached by 50 patients (24.9%) [primary: 7 (25.9%), secondary: 43 (24.7%)], and 151 (75.1%) completed follow-up with transthoracic echocardiography (TTE). Patients' median age was 80 (76-83) years, 112 (55.7%) were female and 181 (90.1%) reported a New-York heart association functional class (NYHA-FC) of III or IV. The remaining baseline clinical and echocardiographic parameters were comparable between the groups, but secondary TR patients had a significantly higher TRI-SCORE (5 (4-8) vs. 7 (5-14), P = 0.010). In both groups, an immediate reduction of TR-Grade post-intervention was observed. This reduction was sustained at follow-up with 80.0% of the primary TR patients classified as moderate or less and 61.8% of the secondary TR patients. This translated to a significant improvement of NHYA-FC in both groups. Kaplan-Meier analysis revealed no differences regarding rates for all-cause mortality between the groups (P < 0.99). CONCLUSION: T-TEER achieves a robust TR reduction in primary TR patients 1 year after intervention with noninferior clinical results to treatment for secondary TR with regards to mortality, re-hospitalization, and NYHA-FC.
RESUMO
Aortic regurgitation (AR) is a common clinical disease associated with significant morbidity and mortality. Investigations based largely on non-invasive imaging are pivotal in discerning the severity of disease and its impact on the heart. Advances in technology have contributed to improved risk stratification and to our understanding of the pathophysiology of AR. Surgical aortic valve replacement is the predominant treatment. However, its use is limited to patients with an acceptable surgical risk profile. Transcatheter aortic valve implantation is an alternative treatment. However, this therapy remains in its infancy, and further data and experience are required. This review article on AR describes its prevalence, mechanisms, diagnosis and treatment.
Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/terapia , Insuficiência da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Resultado do Tratamento , Próteses Valvulares CardíacasRESUMO
BACKGROUND: Patients with mitral regurgitation (MR) and morphologic presence of relevant mitral annular calcification (MAC) represent a challenging phenotypic subset with limited treatment options. OBJECTIVES: The aim of this study was to assess the feasibility of transcatheter mitral valve replacement (TMVR) using dedicated devices for the treatment of MAC patients. METHODS: Consecutive patients with symptomatic MR receiving TMVR and with available computed tomography data from the CHOICE-MI (Choice of Optimal Transcatheter Treatment for Mitral Insufficiency) multicenter registry were stratified by the presence of none or mild mitral annular calcification (MACnone/mild) vs moderate or severe mitral annular calcification (MACmod/sev). RESULTS: Among 279 eligible patients (median age = 76.0 years [Q1-Q3: 71.0-81.0 years], EuroSCORE II = 6.2% [Q1-Q3: 3.9%-12.1%]), 222 (79.6%) presented with MACnone/mild and 57 (20.4%) with MACmod/sev. Patients with MACmod/sev had a higher prevalence of extracardiac arteriopathy (P = 0.011) and primary MR (P < 0.001). Although the technical success rate and the extent of MR elimination did not differ, TMVR treatment in MACmod/sev patients was associated with higher rates of postprocedural bleeding complications (P = 0.02) and renal failure (P < 0.001). Functional improvement at the 1- and 2-year follow-up did not differ between groups. At the 2-year follow-up, there were no differences between patients with MACmod/sev and MACnone/mild regarding all-cause mortality (38.5% vs 37.7%; P = 0.76), cardiovascular mortality (21.3% vs 24.9%; P = 0.97), and all-cause mortality or heart failure hospitalization (52.4% vs 46.7%; P = 0.28) CONCLUSIONS: TMVR in patients with MACmod/sev is associated with higher rates of postprocedural complications but similar rates of survival, MR resolution, and functional improvement compared to MACnone/mild. Further studies are necessary to define the role of dedicated TMVR devices in this population. (Choice of Optimal Transcatheter Treatment for Mitral Insufficiency Registry [CHOICE-MI]; NCT04688190).
Assuntos
Calcinose , Cateterismo Cardíaco , Estudos de Viabilidade , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Valva Mitral , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Humanos , Idoso , Masculino , Feminino , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/mortalidade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Idoso de 80 Anos ou mais , Fatores de Tempo , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Calcinose/mortalidade , Calcinose/fisiopatologia , Calcinose/terapia , Fatores de Risco , Índice de Gravidade de Doença , Europa (Continente)RESUMO
We provide an overview about the current landscape of transcatheter tricuspid valve interventions (TTVI) and summarize recent findings from trials including TRILUMINATE, TRILUMINATE Pivotal, bRIGHT, TRICLASP, TRISCEND, TRISCEND II, TRICUS, and Cardioband TR EFS. These studies have demonstrated the safety and efficacy of TTVI. Yet, they have failed to show a prognostic benefit over conservative treatment. On the other hand, significant improvements in health status assessments have been observed. Assessment of right ventricular (RV) function prior to tricuspid interventions is crucial, as changes in preload and afterload may lead to RV failure which is associated with a high mortality. Therefore, this review emphasizes the impact of TTVIs on quality of life and explores the influence of RV dysfunction on therapeutic success and prognosis.
RESUMO
BACKGROUND: Severe pure aortic regurgitation (AR) carries a high mortality and morbidity risk, and it is often undertreated because of the inherent surgical risk. Transcatheter heart valves (THVs) have been used off-label in this setting with overall suboptimal results. The dedicated "purpose-built" Jena Valve Trilogy (JVT, JenaValve Technology) showed an encouraging performance, although it has never been compared to other THVs. OBJECTIVES: The aim of our study was to assess the performance of the latest iteration of THVs used off-label in comparison to the purpose-built JVT in inoperable patients with severe AR. METHODS: We performed a multicenter, retrospective registry with 18 participating centers worldwide collecting data on inoperable patients with severe AR of the native valve. A bicuspid aortic valve was the main exclusion criterion. The primary endpoints were technical and device success, 1-year all-cause mortality, and the composite of 1-year mortality and the heart failure rehospitalization rate. RESULTS: Overall, 256 patients were enrolled. THVs used off-label were used in 168 cases (66%), whereas JVT was used in 88 (34%). JVT had higher technical (81% vs 98%; P < 0.001) and device success rates (73% vs 95%; P < 0.001), primarily driven by significantly lower incidences of THV embolization (15% vs 1.1%; P < 0.001), the need for a second valve (11% vs 1.1%; P = 0.004), and moderate residual AR (10% vs 1.1%; P = 0.007). The permanent pacemaker implantation rate was comparable and elevated for both groups (22% vs 24%; P = 0.70). Finally, no significant difference was observed at the 1-year follow-up in terms of mortality (HR: 0.99; P = 0.980) and the composite endpoint (HR: 1.5; P = 0.355). CONCLUSIONS: The JVT platform has a better acute performance than other THVs when used off-label for inoperable patients with severe AR. A longer follow-up is conceivably needed to detect a possible impact on prognosis.
Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Feminino , Masculino , Estudos Retrospectivos , Idoso , Resultado do Tratamento , Idoso de 80 Anos ou mais , Fatores de Risco , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Readmissão do Paciente , Recuperação de Função Fisiológica , Europa (Continente) , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/diagnóstico , HemodinâmicaRESUMO
BACKGROUND: Baseline right ventricular (RV) function derived from 3-dimensional analyses has been demonstrated to be predictive in patients undergoing transcatheter tricuspid valve repair (TTVR). The complex nature of these cumbersome analyses makes patient selection based on established imaging methods challenging. Artificial intelligence (AI)-driven computed tomography (CT) segmentation of the RV might serve as a fast and predictive tool for evaluating patients prior to TTVR. METHODS: Patients suffering from severe tricuspid regurgitation underwent full cycle cardiac CT. AI-driven analyses were compared to conventional CT analyses. Outcome measures were correlated with survival free of rehospitalization for heart-failure or death after TTVR as the primary endpoint. RESULTS: Automated AI-based image CT-analysis from 100 patients (mean age 77 ± 8 years, 63% female) showed excellent correlation for chamber quantification compared to conventional, core-lab evaluated CT analysis (R 0.963-0.966; p < 0.001). At 1 year (mean follow-up 229 ± 134 days) the primary endpoint occurred significantly more frequently in patients with reduced RV ejection fraction (EF) <50% (36.6% vs. 13.7%; HR 2.864, CI 1.212-6.763; p = 0.016). Furthermore, patients with dysfunctional RVs defined as end-diastolic RV volume > 210 ml and RV EF <50% demonstrated worse outcome than patients with functional RVs (43.7% vs. 12.2%; HR 3.753, CI 1.621-8.693; p = 0.002). CONCLUSIONS: Derived RVEF and dysfunctional RV were predictors for death and hospitalization after TTVR. AI-facilitated CT analysis serves as an inter- and intra-observer independent and time-effective tool which may thus aid in optimizing patient selection prior to TTVR in clinical routine and in trials.
Assuntos
Inteligência Artificial , Tomografia Computadorizada por Raios X , Insuficiência da Valva Tricúspide , Humanos , Feminino , Masculino , Inteligência Artificial/tendências , Idoso , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Idoso de 80 Anos ou mais , Tomografia Computadorizada por Raios X/métodos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Cateterismo Cardíaco/métodos , Seguimentos , Implante de Prótese de Valva Cardíaca/métodosRESUMO
BACKGROUND: Despite the recommendation of coronary physiology to guide revascularization in angiographically intermediate stenoses without established correlation to ischemia, its uptake in clinical practice is slow. AIMS: This study aimed to analyze the use of coronary physiology in clinical practice. METHODS: Based on a multicenter registry (Fractional Flow Reserve Fax Registry, F(FR)2, ClinicalTrials.gov identifier NCT03055910), clinical use, consequences, and complications of coronary physiology were systematically analyzed. RESULTS: F(FR)2 enrolled 2,000 patients with 3,378 intracoronary pressure measurements. Most measurements (96.8%) were performed in angiographically intermediate stenoses. Out of 3,238 lesions in which coronary physiology was used to guide revascularization, revascularization was deferred in 2,643 (78.2%) cases. Fractional flow reserve (FFR) was the most common pressure index used (87.6%), with hyperemia induced by an intracoronary bolus of adenosine in 2,556 lesions (86.4%) and intravenous adenosine used for 384 measurements (13.0%). The route of adenosine administration did not influence FFR results (change-in-estimate -3.1% for regression model predicting FFR from diameter stenosis). Agreement with the subsequent revascularization decision was 93.4% for intravenous and 95.0% for intracoronary adenosine (p = 0.261). Coronary artery occlusion caused by the pressure wire was reported in two cases (0.1%) and dissection in three cases (0.2%), which was fatal once (0.1%). CONCLUSIONS: In clinical practice, intracoronary pressure measurements are mostly used to guide revascularization decisions in angiographically intermediate stenoses. Intracoronary and intravenous administration of adenosine seem equally suited. While the rate of serious complications of wire-based intracoronary pressure measurements in clinical practice seems to be low, it is not negligible.
Assuntos
Angiografia Coronária , Estenose Coronária , Vasos Coronários , Reserva Fracionada de Fluxo Miocárdico , Sistema de Registros , Humanos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Masculino , Feminino , Estenose Coronária/fisiopatologia , Estenose Coronária/diagnóstico , Pessoa de Meia-Idade , Vasos Coronários/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Idoso , Adenosina/administração & dosagem , Revascularização Miocárdica/métodos , Cateterismo Cardíaco/métodos , Vasodilatadores/administração & dosagemRESUMO
BACKGROUND: Tricuspid valve transcatheter edge-to-edge repair (T-TEER) is the most widely used transcatheter therapy to treat patients with tricuspid regurgitation (TR). OBJECTIVES: The aim of this study was to develop a simple anatomical score to predict procedural outcomes of T-TEER. METHODS: All patients (n = 168) who underwent T-TEER between January 2017 and November 2022 at 2 centers were included in the derivation cohort. Additionally, 126 patients from 2 separate institutions served as a validation cohort. T-TEER was performed using 2 commercially available technologies. Core laboratory assessment of procedural transesophageal echocardiograms was used to determine septolateral and anteroposterior coaptation gap, leaflet morphology, septal leaflet length and retraction, chordal structure density, tethering height, en face TR jet morphology and TR jet location, image quality, and the presence of intracardiac leads. A scoring system was derived using univariable and multivariable logistic regression. Endpoints assessed were immediate postprocedural TR reduction ≥2 grades and TR grade moderate or less. RESULTS: The median age was 82 years (Q1-Q3: 78-84 years); 48% of patients were women; and patients presented with severe (55%), massive (36%), and torrential (8%) TR. Five variables (septolateral coaptation gap, chordal structure density, en face TR jet morphology, TR jet location, and image quality) were identified as best predicting procedural outcome and were incorporated in the GLIDE (Gap, Location, Image quality, density, en-face TR morphology) score (range 0-5). TR reduction ≥2 grades and TR grade moderate or less were observed in >90% of patients with GLIDE scores of 0 and 1 and in only 5.6% and 16.7% of those with GLIDE scores ≥4. The GLIDE score was then externally validated in a separate cohort (area under the curve: 0.77; 95% CI: 0.69-0.86). TR reduction significantly correlated with functional improvement assessed by NYHA functional class and 6-minute walk distance at 3 months. CONCLUSIONS: The GLIDE score is a simple, 5-component score that is readily obtained during patient imaging and can predict successful T-TEER.
Assuntos
Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Feminino , Masculino , Idoso , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Valva Tricúspide/cirurgia , Resultado do Tratamento , Idoso de 80 Anos ou mais , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Técnicas de Apoio para a Decisão , Medição de Risco , Fatores de TempoRESUMO
BACKGROUND: Permanent pacemaker implantation (PMI) is associated with increased morbidity after transcatheter aortic valve replacement (TAVR). Cardiac resynchronization-therapy (CRT) is recommended for patients if left ventricular ejection fraction (LVEF) is ≤ 40% and ventricular pacing is expected in favor to sole right ventricular (RV) pacing. Meanwhile, LVEF may recover after TAVR in patients with aortic valve disease and the benefit of CRT is unknown. OBJECTIVE: To analyze the impact of CRT implantation as compared to RV pacing after TAVR. METHODS AND RESULTS: Between 2012 and 2022, 4385 patients (53.1% female, mean age 81 ± 6 years) without prior PMI undergoing TAVR were retrospectively identified in our institutional registry. After stratification of patients in LVEF ≤ 40%, 41-49% and ≥ 50%, Kaplan-Meier analysis revealed significantly different survival rates in each subgroup at 5 years (37.0% vs. 43.5% vs. 55.1%; P ≤ 0.021). At multivariate regression, LVEF and new PMI after TAVR were not relevant for survival. A total of 105 patients with LVEF ≤ 40% received PMI after TAVR (86 patients with RV pacing and 19 with CRT). At 5 years, all-cause mortality was significantly lower in patients with CRT-device as compared to patients without CRT-device (Kaplan Meier estimate of 21.1% vs. 48.8%; HR 0.48, CI 0.204 - 1.128; log rank p = 0.045). In multivariate analysis CRT remained a significant factor for 5-year survival in these patients (HR 0.3, CI 0.095-0.951, p = 0.041). CONCLUSION: In patients undergoing TAVR, PMI did not influence 5-year survival. In patients with LVEF ≤ 40%, CRT-device implantation was associated with improved survival compared to non-CRT-device implantation.
RESUMO
BACKGROUND: The latest generation ultrathin Supraflex Cruz (Sahajanand Medical Technologies Limited, Surat, India) sirolimus-eluting stent (SES) has shown early healing properties and represents an attractive percutaneous coronary intervention (PCI) device in a high bleeding risk (HBR) population. The aim of this Cruz HBR registry was to assess safety and efficacy of the Supraflex Cruz SES in a large cohort of all-comer patients, of whom about one third were patients at HBR. METHODS: Patients undergoing PCI were enrolled in this prospective, multi-centre, open label registry and stratified into non-HBR and HBR groups. The primary endpoint was a device-oriented composite endpoint (DOCE), a composite of cardiovascular death, myocardial infarction not clearly attributable to a non-target vessel and clinically driven target lesion revascularization within 12 months after PCI. The predefined aims were to show non-inferiority of the non-HBR group to the Supraflex arm of the TALENT Trial, and of the HBR group to polymer-free biolimus-coated stent arm of LEADERS FREE Trial. RESULTS: A total of 1203 patients were enrolled across 26 European centers, including a significant proportion (38.7%; N.=466) of HBR patients. A total of 1745 lesions were treated in 1203 patients and 2235 stents were implanted. The DOCE occurred within the total cohort in 5.8% of patients with a significant difference between HBR patients and non-HBR patients (8.1% vs. 4.4%; P<0.001). All-cause mortality at 12 months was significantly (P<0.0001) different among HBR (9.0%) and non-HBR patients (1.7%), respectively. At 12 months, the overall incidence of definite and probable stent thrombosis was 1.0%. Major bleeding occurred in 5.9% patients of the HBR group. These results met the non-inferiority criteria with respect to the TALENT trial for the non-HBR group (P<0.0001), and the LEADERS FREE trial for the HBR group (P<0.0001). CONCLUSIONS: The Cruz HBR registry confirms that PCI with the Supraflex Cruz SES is associated with a favorable clinical outcome in an all-comer population, including complex patients with HBR.
Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Hemorragia , Intervenção Coronária Percutânea , Polímeros , Sistema de Registros , Sirolimo , Humanos , Stents Farmacológicos/efeitos adversos , Sirolimo/administração & dosagem , Sirolimo/uso terapêutico , Masculino , Feminino , Doença da Artéria Coronariana/cirurgia , Estudos Prospectivos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Idoso , Pessoa de Meia-Idade , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Resultado do Tratamento , Europa (Continente)/epidemiologia , Implantes Absorvíveis , Desenho de Prótese , Fatores de RiscoRESUMO
AIMS: While invasively determined congestion holds mechanistic and prognostic significance in acute heart failure (HF), its role in patients with tricuspid regurgitation (TR)-related right- heart failure (HF) undergoing transcatheter tricuspid valve intervention (TTVI) is less well established. A comprehensive understanding of congestion patterns might aid in procedural planning, risk stratification, and the identification of patients who may benefit from adjunctive therapies before undergoing TTVI. The aim of this study was to investigate the role of congestion patterns in patients with severe TR and its implications for TTVI. METHODS AND RESULTS: Within a multicentre, international TTVI registry, 813 patients underwent right heart catheterization (RHC) prior to TTVI and were followed up to 24 months. The median age was 80 (interquartile range 76-83) years and 54% were women. Both mean right atrial pressure (RAP) and pulmonary capillary wedge pressure (PCWP) were associated with 2-year mortality on Cox regression analyses with Youden index-derived cut-offs of 17 mmHg and 19 mmHg, respectively (p < 0.01 for all). However, RAP emerged as an independent predictor of outcomes following multivariable adjustments. Pre-interventionally, 42% of patients were classified as euvolaemic (RAP <17 mmHg, PCWP <19 mmHg), 23% as having left-sided congestion (RAP <17 mmHg, PCWP ≥19 mmHg), 8% as right-sided congestion (RAP ≥17 mmHg, PCWP <19 mmHg), and 27% as bilateral congestion (RAP ≥17 mmHg, PCWP ≥19 mmHg). Patients with right-sided or bilateral congestion had the lowest procedural success rates and shortest survival times. Congestion patterns allowed for discerning specific patient's physiology and specifying prognostic implications of right ventricular to pulmonary artery coupling surrogates. CONCLUSION: In this large cohort of invasively characterized patients undergoing TTVI, congestion patterns involving right-sided congestion were associated with low procedural success and higher mortality rates after TTVI. Whether pre-interventional reduction of right-sided congestion can improve outcomes after TTVI should be established in dedicated studies.
Assuntos
Cateterismo Cardíaco , Sistema de Registros , Insuficiência da Valva Tricúspide , Humanos , Feminino , Masculino , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/diagnóstico , Idoso , Cateterismo Cardíaco/métodos , Idoso de 80 Anos ou mais , Pressão Propulsora Pulmonar/fisiologia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Índice de Gravidade de Doença , Prognóstico , Implante de Prótese de Valva Cardíaca/métodos , Valva Tricúspide/fisiopatologia , Resultado do TratamentoRESUMO
BACKGROUND: Among low-risk patients with severe, symptomatic aortic stenosis who are eligible for both transcatheter aortic-valve implantation (TAVI) and surgical aortic-valve replacement (SAVR), data are lacking on the appropriate treatment strategy in routine clinical practice. METHODS: In this randomized noninferiority trial conducted at 38 sites in Germany, we assigned patients with severe aortic stenosis who were at low or intermediate surgical risk to undergo either TAVI or SAVR. Percutaneous- and surgical-valve prostheses were selected according to operator discretion. The primary outcome was a composite of death from any cause or fatal or nonfatal stroke at 1 year. RESULTS: A total of 1414 patients underwent randomization (701 to the TAVI group and 713 to the SAVR group). The mean (±SD) age of the patients was 74±4 years; 57% were men, and the median Society of Thoracic Surgeons risk score was 1.8% (low surgical risk). The Kaplan-Meier estimate of the primary outcome at 1 year was 5.4% in the TAVI group and 10.0% in the SAVR group (hazard ratio for death or stroke, 0.53; 95% confidence interval [CI], 0.35 to 0.79; P<0.001 for noninferiority). The incidence of death from any cause was 2.6% in the TAVI group and 6.2% in the SAVR group (hazard ratio, 0.43; 95% CI, 0.24 to 0.73); the incidence of stroke was 2.9% and 4.7%, respectively (hazard ratio, 0.61; 95% CI, 0.35 to 1.06). Procedural complications occurred in 1.5% and 1.0% of patients in the TAVI and SAVR groups, respectively. CONCLUSIONS: Among patients with severe aortic stenosis at low or intermediate surgical risk, TAVI was noninferior to SAVR with respect to death from any cause or stroke at 1 year. (Funded by the German Center for Cardiovascular Research and the German Heart Foundation; DEDICATE-DZHK6 ClinicalTrials.gov number, NCT03112980.).
Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Estimativa de Kaplan-Meier , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Fatores de Risco , AlemanhaRESUMO
OBJECTIVE: Management of patients with severe aortic stenosis (AS) may differ according to the patient sex. This study aimed to describe patterns of aortic valve replacement (AVR) for severe AS across Europe, including stratification by sex. METHODS: Procedure volume data for surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI) for six years (2015-2020) were extracted from national databases for Austria, Czech Republic, Denmark, England, Finland, France, Germany, Norway, Poland, Spain, Sweden, and Switzerland and stratified by sex. Patients per million population (PPM) undergoing AVR per year were calculated using population estimates from Eurostat. RESULTS: Between 2015 and 2019, AVR procedures grew at an average annual rate of 3.9%. In 2020, the average total PPM undergoing AVR across all countries was 339, with 51% of procedures being TAVI and 49% SAVR. AVR PPM varied widely between countries, with the highest and lowest in Germany and Poland, respectively. The average total PPM was higher for men than women (423 vs. 258), but a higher proportion of women (62%) than men (44%) received TAVI. The proportion of TAVI among total AVR procedures increased with age, with an overall average of 96% of men and 98% of women aged ≥85 years receiving TAVI; however, adoption of TAVI varied by country. CONCLUSIONS: The analysis of temporal trends in the adoption of TAVI vs. SAVR across Europe showed significant variations. Despite the higher use of TAVI vs. SAVR in women, overall rates of AV intervention in women were lower compared to men.
Assuntos
Estenose da Valva Aórtica , Humanos , Feminino , Masculino , Europa (Continente)/epidemiologia , Idoso , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/epidemiologia , Idoso de 80 Anos ou mais , Fatores Sexuais , Substituição da Valva Aórtica Transcateter/tendências , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Implante de Prótese de Valva Cardíaca/tendências , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Valva Aórtica/cirurgia , Pessoa de Meia-IdadeRESUMO
Currently, there is no specific medication approved for the treatment of valvular heart disease per se. Except for secondary mitral valve insufficiency and tricuspid valve insufficiency in pulmonary hypertension, drug therapy for higher-grade valvular heart disease is limited to diuretic therapy for symptom control. Conservative therapy for comorbidities and potential heart failure can be beneficial regardless of the specific valve lesion. In cases of aortic valve stenosis or insufficiency, controlling arterial hypertension is important. Patients with mitral valve stenosis benefit from rhythm and rate control. Diuretics can help reduce regurgitant volume in patients with primary mitral valve insufficiency and tricuspid valve insufficiency. In addition to drug therapy, maintaining functional capacity is crucial for the outcome of patients. Therefore, it is recommended to engage in active physical activity whenever possible, despite the presence of valvular heart disease.
Assuntos
Doenças das Valvas Cardíacas , Humanos , Doenças das Valvas Cardíacas/tratamento farmacológico , Adulto , Tratamento Conservador/métodos , Diuréticos/uso terapêuticoRESUMO
BACKGROUND: Clinical management of patients with angina and no obstructive coronary artery disease (ANOCA) is still challenging. This scenario affects up to 50% of patients undergoing diagnostic coronary angiography due to suspected coronary artery disease. Many patients report a long and debilitating history before adequate diagnostics and management are initiated. OBJECTIVES: This article describes the current recommendations for diagnostic assessments and treatment in patients with ANOCA. Focus is placed on invasive diagnostics in the catheter laboratory, pharmacological/interventional treatment as well as the patient journey. RESULTS: In patients with ANOCA, the current European Society of Cardiology (ESC) guidelines suggest that invasive assessments using acetylcholine and adenosine for the diagnosis of an underlying coronary vasomotor disorder should be considered. Acetylcholine is used to diagnose coronary spasm, whereas adenosine is used in conjunction with a wire-based assessment for the measurement of coronary flow reserve and microvascular resistance. The invasive assessments allow the determination of what are referred to as endotypes (coronary spasm, impaired coronary flow reserve, enhanced microvascular resistance or a combination thereof). Establishing a diagnosis is helpful to: (a) initiate targeted treatment to improve quality of life, (b) reassure the patient that a cardiac cause is found and (c) to assess individual prognosis. CONCLUSIONS: Currently, patients with ANOCA are often not adequately managed. Referral to specialised centres is recommended to prevent long and debilitating patient histories until expertise in diagnosis and treatment becomes more widespread.
Assuntos
Angina Pectoris , Angiografia Coronária , Humanos , Angiografia Coronária/métodos , Angina Pectoris/terapia , Angina Pectoris/diagnóstico por imagem , Angina Pectoris/diagnóstico , Vasoespasmo Coronário/diagnóstico por imagem , Vasoespasmo Coronário/diagnóstico , Vasoespasmo Coronário/terapia , Acetilcolina , Adenosina/administração & dosagemRESUMO
BACKGROUND: In patients not suitable for transfemoral transcatheter aortic valve implantation (TAVI), several access strategies can be chosen. AIM: To evaluate the use and patient outcomes of transaxillary (TAx), transapical (TA), and transaortic (TAo) as alternative access for TAVI in Germany; to further evaluate surgical cutdown vs. percutaneous TAx access. METHODS: All patients entered the German Aortic Valve Registry (GARY) between 2011 and 2019 who underwent non-transfemoral TAVI were included in this analysis. Patients with TA, TAo, or TAx TAVI were compared using a weighted propensity score model. Furthermore, a subgroup analysis was performed for TAx regarding the percutaneous or surgical cutdown approach. RESULTS: Overall, 9686 patients received a non-transfemoral access. A total of 8918 patients (92.1%) underwent TA, 398 (4.1%) TAo, and 370 (3.8%) TAx approaches. Within the TAx subgroup, 141 patients (38.1%) received subclavian cutdown, while 200 (54.1%) underwent a percutaneous approach. The TA patients had a significantly lower 30-day survival than TAx patients (TA 90.92% vs. TAx 95.59%, p = 0.006; TAo 92.22% vs. TAx 95.59%, p = 0.102). Comparing percutaneous and cutdown TAx approaches, no significant differences were seen. However, more vascular complications occurred (TA 1.8%, TAo 2.4%, TAx 12.2%; p < .001), and the hospital length of stay was shorter (TA 12.9 days, TAo 14.1 days, TAx 12 days; p < .001) after TAx access. CONCLUSION: It may be reasonable to consider TAx access first in patients not suitable for TF-TAVI, because the 30-day survival was higher compared with TA access and the 1-year survival was higher compared with TAo access. It remains important for the heart teams to offer alternative access modalities for patients not amenable to the standard TF-TAVI approaches.
Assuntos
Inteligência Artificial , Anuloplastia da Valva Cardíaca , Valor Preditivo dos Testes , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/fisiopatologia , Masculino , Resultado do Tratamento , Interpretação de Imagem Radiográfica Assistida por Computador , Software , Feminino , Angiografia Coronária , Angiografia por Tomografia Computadorizada , Idoso , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Pessoa de Meia-Idade , Tomada de Decisão ClínicaRESUMO
BACKGROUND AND AIMS: Prosthetic valve endocarditis (PVE) is the prognostically most unfavourable complication after aortic valve replacement. This study aims to contribute to a better understanding of the different pathological and therapeutical aspects between PVE following surgical (SAVR) and transcatheter aortic valve replacement (TAVI). METHODS: All patients who had undergone primary isolated SAVR (n = 3447) or TAVI (n = 2269) at our Centre between 01/2012 and 12/2018 were analysed. Diagnosis of PVE was based on Duke criteria modified in 2015. Incidence, risk factors, pathogens, impact of complications or therapy on mortality were analysed and compared between SAVR- and TAVI-PVE. RESULTS: PVE incidence did not differ significantly after SAVR with 4.9/100 patient-years and TAVI with 2.4/100 patient-years (p = 0.49), although TAVI patients were older (mean 80 vs. 67 years) and had more comorbidities (STS score mean 5.9 vs. 1.6) (p < 0.001). TAVI prostheses with polymer showed a 4.3-fold higher risk to develop PVE than without polymer (HR 4.3; p = 0.004). Most common pathogens were staphylococci and enterococci (p > 0.05). Propensity-score matching analysis showed that the type of aortic valve replacement had no effect on the development of post-procedural PVE (p = 0.997). One-year survival was higher in TAVI-PVE patients treated with antibiotics only compared to additional surgical therapy (90.9% vs. 33.3%; p = 0.005). In SAVR-PVE patients, both therapies were comparable in terms of survival (p = 0.861). However, SAVR-PVE patients who were not operated, despite ESC-guideline recommendation, had significantly poorer one-year survival (p = 0.004). CONCLUSION: TAVI patients did not have a significantly higher risk to develop PVE. Our data suggest that TAVI-PVE patients in contrast to SAVR-PVE patients can more often be treated with antibiotics only, presumably due to the lack of a polymeric suture ring.